Whirlpool AD40LJ0 User Manual

Contents
Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Electrical requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Installing dehumidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Operating dehumidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Removing and emptying water bucket . . . . . . . . . . . . . . . . . . . .6-7
Water level float and automatic shutoff . . . . . . . . . . . . . . . . . . . .8
Caring for your dehumidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
If you need assistance or service . . . . . . . . . . . . . . . . . . . . . .10-11
Use & Care Guide
Part No. 1183900 Rev. A
WARNING — To reduce the risk of fire, electrical shock, injury or sickness when using your dehumidifier, follow these basic precautions:
• Plug into a grounded 3 prong outlet.
• Do not remove ground prong.
• Do not use an adapter.
• Do not use an extension cord.
• Unplug dehumidifier before servicing.
• Do not drink water collected in the water bucket.
— SAVE THESE INSTRUCTIONS —
It is your responsibility to:
• Install the dehumidifier according to the Installation Instructions.
• Connect the dehumidifier only to the proper kind of outlet, with the correct electrical supply and ground. See “Electrical requirements,” page 3.
IMPORTANT SAFETY INSTRUCTIONS

Safety information

2
Your safety and the safety of others
are very important.
We have provided many important safety messages in this manual and on your appliance.Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you
and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or ‘“WARNING. ”These words mean:
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
You can be killed or seriously injured if you don’t follow instructions.
You can be killed or seriously injured if you don’t immediately follow instructions.

Electrical requirements

3
WARNING
Grounding instructions:
A 115-volt (103.5 min., 126.5 max.), 60-Hz, AC-only, 15- or 20-ampere fused and properly grounded electrical supply is required. A time-delay fuse or time-delay circuit breaker is recommended. Use a separate circuit to connect only the dehumidifier.
For your personal safety, this dehumidifier must be grounded.This dehumidifier is equipped with a power supply cord having a 3-prong ground plug.
To minimize possible shock hazard, the cord must be plugged into a mating 3-prong ground-type outlet, grounded in accordance with local codes and ordinances. If a mating outlet is not available, it is the personal responsibility and obligation of the customer to have the properly grounded outlet installed by a qualified electrician.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these
instructions can result in death, fire, or electrical shock.
3-prong ground plug
3-prong ground-type outlet
ground prong
power supply cord
Safety information
4
Install dehumidifier on a level floor strong enough to support the dehumidifier with a full bucket of water.
Good air circulation is needed for best performance—allow at least 12-18 inches (30.5 -
45.7 cm) of air space on all
sides of the dehumidifier.
Keep all outside doors, windows and other openings closed when operating dehumidifier. Humid outdoor air will increase dehumidifier workload.
Installing dehumidifier
12-18"
(30.5 - 45.7 cm)
12-18" (30.5 - 45.7 cm)
4
Safety information
5

Operating dehumidifier

FAN SPEED:
Some models: this controls fan operation. Use desired setting.
HIGH - for faster moisture removal. LOW - for slower moisture removal.
EMPTY/ADJUST BUCKET light:
If this light is on, the dehumidifier is not running. This light indicates that
you need to check:
• If the bucket is full, empty bucket and replace.
• If the bucket is not in position,
remove bucket and replace. Make sure the bucket fits all the way into the dehumidifier and the light is off, or dehumidifier will not run.
DRYNESS CONTROL:
This controls the amount of moisture in the room.Turn the control knob clockwise for more drying. Turn the control knob counterclockwise for less drying. Turn control knob to “NORMAL” to maintain average humidity conditions. NOTE: For the first few days of use, turn the Dryness Control clockwise to “DRYEST” to remove extra moisture from the furnishings as well as the room air.
FAN SPEED
HIGH
LOW
DRYNESS CONTROL
EMPTY/ADJUST
BUCKET
N
O
R
M
A
L
D
R
Y
E
S
T
OFF
CONTINUOUS
5

Removing & emptying water bucket

6
Bucket method:
Bucket styles:
1. Use both side handles to lift bucket. Pull bucket forward and remove. Go to Step 2.
3. Pour water through opening into a sink or tub.
4. Replace bucket completely and check that EMPTY/ADJUST BUCKET light is off.
WARNING
Sickness Hazard Do not drink water collected in water bucket. Doing so can result in sickness.
1. Lift bucket from bottom. Pull bucket forward and remove.Go to Step 2.
style 1
style 2
2. Carry bucket to a large sink or tub.
Bucket style 2
Bucket style 1
Removing & emptying water bucket
7
Drain hose connection method:
(to drain water from bucket continuously)
Do Not damage outside or connection will leak.
drain hose connector cover (not on all models)
center of drain hose connector
3. Attach a garden hose to drain hose connector.The garden hose should not be longer than 8 feet (2.4 m). Run other end of garden hose into a floor drain. Check that the hose lies flat and in the drain.
To use the bucket without the garden hose:
For bucket style 1:
Use a garden hose cap to seal the drain hose connector.
For bucket style 2:
Use a garden hose cap to seal the drain hose connector. Replace drain hose connector cover.
1. If your dehumidifier does not have a drain hose connector cover, go to
Step 2.
If your dehumidifier has a drain hose connector cover, use a flat-
blade screwdriver to remove cover from drain connector.Turn cover counterclockwise. Discard cover. It cannot be reused. Go to Step 2.
2. Drill out only the center of the drain hose connector.Use a minimum 1/4" drill bit.
Bucket style 1
1. Slide off the drain hose connector
cover. Go to Step 2.
Bucket style 2
Safety information

Water level float & automatic shutoff

For models with non-adjustable Water Level Float:
For models with adjustable Water Level Float:
All dehumidifiers have automatic shutoff and a water level float. Some dehumidifiers feature an adjustable Water Level Float. The bucket must be properly aligned for the Water Level Float to work.
The Water Level Float will shut off the dehumidifier automatically.
You can set the adjustable Water Level Float at the “high” or “low” position. B oth settings will turn off the dehumidifier automatically.
“High”setting: Water Level Float is preset to the “high” position—left side of opening.The dehumidifier will shut off automatically when bucket is 3/4 full.
“Low” setting: Slide Water Level Float to “low”position—right side of opening — to make the bucket lighter to carry. The dehumidifier will shut off automatically when bucket is 1/2 full.
8
Loading...