Welch Allyn Digital MacroView Otoscope User Manual [en, de, es, fr, it, pl]

0 (0)

Digital MacroView™ Otoscope

Directions for Use

Reorder No. 23920MANHCP

 

Material No. 709000 Ver. B

Printed in USA

ii

Digital MacroView™ Otoscope

Directions for Use

ii

Copyright 2008 Welch Allyn. All rights are reserved. No one is permitted to reproduce or duplicate, in any form, this manual or any part thereof without permission from Welch Allyn.

Caution: Federal law restricts this device to sale by or on the order of a licensed professional trained in otoscopy.

Welch Allyn assumes no responsibility for any injury, or for any illegal or improper use of the product, that may result from failure to use this product in accordance with the instructions, cautions, warnings, or indications for use published in this manual.

Welch Allyn is a registered trademark of Welch Allyn, Inc. Digital Macroview is a trademark of Welch Allyn, Inc.

Software in this product is copyright Welch Allyn or its vendors. All rights are reserved. The software is protected by United States of America copyright laws and international treaty provisions applicable worldwide. Under such laws, the licensee is entitled to use the copy of the software incorporated with this instrument as intended in the operation of the product in which it is embedded. The software may not be copied, decompiled, reverse-engineered, disassembled or otherwise reduced to human-perceivable form. This is not a sale of the software or any copy of the software; all right, title, and ownership of the software remain with Welch Allyn or its vendors.

Caution: Changes or modifications not expressly approved by Welch Allyn could void the purchaser’s authority to operate the equipment.

iii

For information about any Welch Allyn product, call Welch Allyn Technical Support:

USA

+ 1 315 685 4560

Australia

+ 61 29 638 3000

 

800 535 6663

 

 

Canada

800 561 8797

China

+ 86 216 327 9631

European Call Center

+ 353 46 906 7790

France

+ 331 6009 3366

Germany

+ 49 747 792 7186

Japan

+ 81 33 219 0071

Latin America

+ 1 305 669 9003

Netherlands

+ 31 15 750 5000

Singapore

+ 65 6419 8100

South Africa

+ 27 11 777 7555

United Kingdom

+ 44 207 365 6780

Sweden

+ 46 85 853 6551

Reorder No. 23920MAN/23960MAN

 

 

80012182 Ver. F

 

 

Printed in USA

Welch Allyn

 

 

European Regulatory Manager

EC

REP

4341 State Street Road,

Welch Allyn Ltd.

 

 

PO Box 220

 

 

Navan Business Park

Skaneateles Falls, NY

 

 

Dublin Road

13153-0220

 

 

 

 

Navan, County Meath,

www.welchallyn.com

 

 

Republic of Ireland

Tel.: +353 46 90 67700

Fax: +353 46 90 67755

iv

v

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 User Profile. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Warnings and cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

2 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Using the otoscope head . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Using the Digital MacroView System. . . . . . . . . . . . . . . . . . 8 Using focus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Using the controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Reviewing images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Standby Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Using the throat illuminator . . . . . . . . . . . . . . . . . . . . . . . . 13

3 Maintenance and service. . . . . . . . . . . . . . . . . 15

Replacing the lamp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Cleaning recommendation . . . . . . . . . . . . . . . . . . . . . . . . . 16 Recycling the system components . . . . . . . . . . . . . . . . . . 17 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Service policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

4 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . 23

vi

1

1 Introduction

The Digital MacroView System consists of a digital otoscope head and a USB Video Cable. A 3.5 volt Welch Allyn power source and a computer are necessary to use the Digital MacroView System.

The Digital MacroView System is designed for “Plug and Play” operation - all adjustments including illumination and white balance are pre-set at the factory.

System Requirements

The Digital MacroView requires a user device running Windows XP Service Pack 2 or later operating system, a viewing screen, and a USB 2.0 port.

Intended use

The otoscope is intended to allow inspection of the external ear, ear canal, and tympanic membrane under magnification. A secondary use of the otoscope may be for assessing the flexibility of the tympanic membrane (pneumatic otoscopy).

User Profile

The Digital MacroView is intended for licensed professionals trained in otoscopy.

2

Introduction

Welch Allyn

Symbols

Safety Symbols

 

 

 

WARNING

 

 

Caution

 

 

 

Caution: Consult

IPXØ Not protected from the

 

 

 

accompanying

 

 

ingress of water

 

 

 

documentation

 

 

 

 

 

 

Type BF

 

 

Temperature limits

 

 

 

 

 

 

 

USB

 

 

Relative humidity limit

 

 

 

 

 

Recycle the product separate from other disposables. See “Recycling the system components” on page 17.

Button Symbols

Capture Image

Zoom

Agency Symbols

CERTIFIED TO:

CAN/CSA STD C22.2 NO. 601.1

C

US

CONFORMS TO:

 

166292

UL STD 60601-1

 

 

IEC 60601-1

Directions for use

Digital MacroView

3

 

The CE mark on this product indicates that it has been tested

 

to and conforms with the provisions noted within the 93/42/

 

EEC Medical Device Directive.

EC REP

European Regulatory Manager

Welch Allyn Ltd.

 

 

Navan Business Park • Dublin Road • Navan, County Meath,

Republic of Ireland

Tel.: +353 46 90 67700 • Fax: +353 46 90 67755

4

Introduction

Welch Allyn

Warnings and cautions

Familiarize all operating personnel with the general safety information in this summary. Specific warnings and cautions are also found throughout this manual. Such specific warnings and cautions may not appear here in this summary.

Warnings

A warning statement in this manual identifies a condition or practice, which if not corrected or discontinued immediately, could lead to injury, illness, or death.

WARNING Do not use in the presence of flammable anesthetics.

WARNING This product has no user serviceable/ replaceable parts except for the lamp. Please refer all other service to authorized service personnel.

WARNING This instrument is not intended to be used in the eye.

WARNING This product generates and records reference images from inputs obtained from the Welch Allyn Digital Macroview. These reference images are not intended for diagnostic purposes.

Directions for use

Digital MacroView

5

Cautions

A caution statement in this manual identifies a condition or practice, which if not corrected or discontinued immediately, could lead to equipment failure, equipment damage, or data loss.

Caution In order to obtain optimum performance and ensure patient safety, thoroughly read this booklet.

Caution The Digital MacroView System is designed expressly for use with an approved Welch Allyn 3.5v power source. Damage to the system will occur if alternate power sources are attached to the video head.

Caution Do not use the Digital MacroView if you notice any signs of damage to the components of the system. Contact Customer Service Department for immediate assistance.

Caution Before each use, the outer surface of the ear specula on the Digital MacroView which is intended to be inserted into a PATIENT should be checked to ensure there are no unintended rough surfaces, sharp edges or protrusions which may Cause a SAFETY HAZARD.

Caution Do not attempt to disinfect the Digital MacroView System using glutaraldehyde products, ethylene oxide gas, steam or any other liquid or gas disinfectant.

Caution The signal output (USB Port) connector is intended for connection of only devices complying with IEC 60601-1, or other IEC standards (for example, IEC 60950), as appropriate to the device. Connecting additional devices to the Digital MacroView System is configuring a medical system and you are responsible for verifying that the system complies with the requirements of the system standard IEC 60601-1-1.

6

Introduction

Welch Allyn

Caution This product complies with current required standards for electromagnetic interference and should not present problems to other equipment or be affected by other devices. As a precaution, avoid using this device in close proximity to other equipment.

Caution To minimize external otoscope housing temperatures, on-time should not exceed 2 minutes and off-time a minimum of 10 minutes.

Caution Only accepts Welch Allyn specula.

Caution Use only Welch Allyn approved lamps.

Caution Do not apply alcohol, chemicals, or water to the lenses. Solution entering the optical assembly could damage internal components.

Welch Allyn Digital MacroView Otoscope User Manual

7

2 Operation

Using the otoscope head

Align the cutouts in the otoscope head base with power source lugs. Push down slightly and turn 90° clockwise. To remove, reverse this procedure. The otoscope head fits all 3.5v

Welch Allyn power sources.

Cutout

Lug

Caution Only accepts

Welch Allyn specula.

Attach: Twist the specula

 

clockwise until it clicks into

 

the locked position.

 

Remove: Turn the TipGrip or

TipGrip

twist the specula

 

counterclockwise.

 

8

Operation

Welch Allyn

Setup

Prior to using the Digital MacroView for the first time, install the Welch Allyn Viewer Utility following the instructions provided with the Viewer CD.

Using the Digital MacroView System

1.Verify the power source is off and attach the Welch Allyn Digital MacroView head to the power source (see page 7).

2.Connect the USB cable to the port on the back of the Digital MacroView head and to the computer USB port. The computer gives an audible signal that the connection is complete.

USB Port

3.Double-click the Welch Allyn Viewer icon on your computer desktop.

Directions for use

Digital MacroView

9

4.Turn the power source to FULL ON position to achieve optimum performance. The computer displays an image. Digital MacroView automatically optimizes the image brightness.

If necessary, adjust the color and brightness controls on the computer monitor for picture quality.

Using focus

Default Position: align the green line to the green dot.

Free Focus: rotate either wheel to fine-tune the image.

10

Operation

Welch Allyn

Using the controls

Capture: Press and hold either function button for approximately 1 second. Upon release of the function button the image freezes as a thumbnail on the screen. If the image is rotated (see below) then the captured image is rotated.

Zoom: Press and hold either function button for approximately 2 seconds. Zoom is for on-screen viewing purposes only. Capturing an image while in zoom mode produces a standard thumbnail. Press and hold either function button again to zoom out.

Rotate: Press and hold both buttons for approximately 4 seconds. Image rotates 180° on screen. Press and hold again to return the image to its original position.

Directions for use

Digital MacroView

11

Reviewing images

Snapshot: Click to take a snapshot from the viewer. Image displays as a thumbnail on the screen.

Record Video Clip: Click to start recording (green icon); click again to stop recording (blue icon). Video clip displays as a thumbnail on the screen and marked as Video. NOTE: You must have a video recorder such as Windows Movie Maker or Windows Media Player installed on your computer.

View Full Screen: Click to view full screen.

Press ESC to return to the normal view.

Settings:

Default Directory: Click Browse and select the file path where you want to save your images.

Video Clip Length: Select Video Capture Limit and select an option. Two minutes is the maximum allowable length of a recorded video.

Default File Format: Select an available file type for your graphics.

Save All Images/Videos: Select Yes. To save a single image/video: Right-click the thumbnail and select Clear. Answer Yes.

View Saved Images/Videos: Window displays default directory for storage. Select the file or select another diretory or folder to locate the desired file. Double-click on the file name to view the image.

Clear All Images/Videos: Select Yes. To clear a single image/video:

Right-click the thumbnail and select Clear. Answer Yes.

12

Operation

Welch Allyn

Standby Mode

The Digital MacroView shuts down the active viewing window after approximately 12 hours of continuous connection to the active viewing window and computer.

To restart the Digital MacroView:

1.Press either function button and re-open Windows Explorer.

2.Open Windows Explorer and click My Computer in the left pane. Double-click the USB Video Device.

Or double-click the My Computer icon on your computer desktop and double-click the USB Video Device.

Directions for use

Digital MacroView

13

Using the throat illuminator

The Welch Allyn Digital MacroView can transform into a throat illuminator. While using the throat illuminator there are no images available on screen or for capture.

WARNING It is important to note that while the throat illuminator section provides an excellent source of general illumination, avoid more than momentary direct skin contact due to possible heat build up.

1.Grasp the otoscope section with the left hand.

2.Grasp the throat illuminator’s collar at (under the silver ring).

3.Hold the throat illuminator collar stationary, twist the otoscope section counterclockwise until the otoscope head is removed.

To replace otoscope section, align the otoscope section with the top of the throat illuminator and turn clockwise.

Throat

Throat

Illuminator

Illuminator

 

14

Operation

Welch Allyn

15

3 Maintenance and service

Replacing the lamp

Caution Halogen lamps are pressurized to provide maximum efficiency and illumination. Mistreatment may cause shattering. Protect lamp surface against abrasions and scratches. Use protective eyeglasses when handling. Dispose of lamp with care.

Caution Only use Welch Allyn lamp REF 06500-U.

Caution Lamps may be hot. Allow the lamps to cool before removing.

Caution Avoid removing the lamp for reasons other than replacement.

It is necessary to re-calibrate the white balance on the Digital MacroView after replacing the lamp.

16

Maintenance and service

Welch Allyn

To recalibrate the white balance:

Use a fully-charged 3.5v power source.

1.Connect the head to the computer and turn the power to the full on position see “Using the Digital MacroView System” on page 8.

2.Shine the light on a piece of white paper approximately 3.2 cm (1.25”) away.

3.Unfold a standard paperclip and insert it into the white balance reset hole. Push slightly to activate the white balance reset button.

The image becomes blue on the computer screen. A live image returns to the computer screen when calibrated.

If the screen is red then repeat steps 1 through 3 above.

White balance reset hole

Cleaning recommendation

Caution Do not apply alcohol, chemicals, or water to the lenses. Solution entering the optical assembly could damage internal components.

Use a dry cloth to clean the Digital MacroView System monthly.

Directions for use Digital MacroView 17

Recycling the system components

Within the EU

Do not dispose of this product as unsorted municipal waste. Prepare it for reuse or separate collection as specified by Directive 2002/96/EC of the European Parliament and the Council of the European Union on Waste Electronic and Electrical Equipment (WEEE).

If this product is contaminated, this directive does not apply.

For more specific disposal information, see www.welchallyn.com/weee, or contact Welch Allyn Customer Service.

Outside the EU

When the product and its components reach end of life, recycle it locally according to national, state, and local regulations, or return it to Welch Allyn.

18 Maintenance and service Welch Allyn

Accessories

REF

Description

23900-10

Replacement USB cable, 10 ft length

23804

Insufflator bulb for MacroView

23857

3.5v Throat Illuminator section only

24302-U

Universal Poly Reusable Speculum 2.5mm

24303-U

Universal Poly Reusable Speculum 3mm

24304-U

Universal Poly Reusable Speculum 4mm

24305-U

Universal Poly Reusable Speculum 5mm

24400-U

Set of 4 Universal Reusable Speculum

52432-U

2.75mm Disposable Ear Specula

52434-U

4.25mm Disposable Ear Specula

24320

SofSeal Small, Disposable Sealing Tip

24330

SofSeal Medium, Disposable Sealing Tip

06500-U

Lamp

23920MAN/

Directions for Use - CD

23960MAN

 

23920-QSG

Quick Start Guide

Directions for use

Digital MacroView

19

Service policy

All repairs on products under warranty must be performed or approved by Welch Allyn. Unauthorized repairs will void the warranty. In addition, whether or not covered under warranty, any product repair shall exclusively be performed by Welch Allyn certified service personnel.

If the product fails to function properly — or if you need assistance, service, or spare parts — contact Welch Allyn.

Before contacting Welch Allyn, try to duplicate the problem, and check all accessories to ensure that they are not causing the problem. When calling, please be prepared to provide:

Product name and model number and complete description of the problem.

Serial number of your product (if applicable).

Complete name, address and phone number of your facility.

For out-of-warranty repairs or spare parts orders, a purchase order (or credit card) number.

For parts orders, the required spare or replacement part numbers.

If your product requires warranty, extended warranty, or non-warranty repair service, please call Welch Allyn. A representative will assist you troubleshooting the problem and will make every effort to solve it over the phone, avoiding potential unnecessary returns. In case a return cannot be avoided, the representative will record all necessary information and will provide a Service Notification number, as well as the appropriate return address. The Service Notification number must be obtained prior to any return.

If you have to return goods for service, follow these recommended packing instructions:

Remove all hoses, cables, sensors, power cords, and ancillary products (as appropriate) before packing, unless you suspect they are associated with the problem.

Wherever possible use the original shipping carton and packing materials.

Include a packing list and the Welch Allyn Service Notification number.

It is recommended that all returned goods be insured. Claims for loss or damage to the product must be initiated by the sender.

20

Maintenance and service

Welch Allyn

21

4 Specifications

Item

Specification

 

 

Weight

Approximately 95 g (0.2 lb)

 

 

Dimensions

Height: 7.0 cm (2.8 inches)

(approximate)

Length: 10.2 cm (4.0 inches)

 

Width: 3.7 cm (1.5 inches)

 

 

Rating

Lamp: 3.5Vdc, 810 mA

 

USB: 5.0Vdc, 150 mA

 

 

Protection against ingress of

IPXØ

water

 

 

 

Operating conditions

 

Temperature

+10° C to +40° C (+50° F to +104° F)

Relative humidity

30% to 75% noncondensing

Altitude

700 to 1060 hPa

 

 

Shipping and storage conditions

 

Temperature

-20° C to +49° C (-4° F to +120° F)

Relative humidity

95% noncondensing max.

 

 

Intermittent operation

< 2 minutes on, > 10 minutes off between uses

 

 

Safety, EMC, and regulatory

CAN/CSA C22.2 No. 601.1-M90, including amendments 1 & 2

compliance

EN/IEC 60601-1

 

EN/IEC 60601-1-2

 

UL 60601-1

 

 

Patents

Patents Pending

 

 

22

Specifications

Welch Allyn