Vulcan-Hart 1024P, 1036P, 1036W, 1048C, 1048P User Manual

...
0 (0)
Vulcan-Hart 1024P, 1036P, 1036W, 1048C, 1048P User Manual

SERVICE &

PARTS MANUAL

1024, 1036, 1048 CHEESEMELTER

MODELS

 

1024C

ML-103833

1024W

ML-103834

1024P

ML-103835

1036C

ML-103836

1036W

ML-103837

1036P

ML-103838

1048C

ML-103839

1048W

ML-103840

1048P

ML-103841

Model 1036W

For additional information on Vulcan-Hart or to locate an authorized parts and service provider in your area, visit our website at www.vulcanhart.com

VULCAN-HART

 

P.O. BOX 696, LOUISVILLE, KY 40201-0696

DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC

 

TEL. (800) 814-2028

WWW.VULCANHART.COM

– 1 –

FORM 31087 Rev. B (June 2006)

 

 

 

PARTS REPLACEMENT

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW THE LOCKOUT / TAGOUT PROCEDURES.

HEATER (Fig. 1)

1.Push one end of the heater into one socket as far as it will go.

2.Swing the other end of heater up until it lines up with the opposite socket.

3.Release heater and it will snap into place.

4.Grasp the heater and move it back and forth to ensure that it is centered correctly.

5.Rotate the heater clockwise, then counterclockwise, to ensure that it is seated correctly.

PL-53526-E

Fig. 1

COOLING FANS

1.Remove the access panel on the left side of the cheesemelter.

2.Unscrew the four mounting screws.

3.Disconnect the fan leads and lift out the fan.

4.Install new fan.

Make sure that all wires are enclosed by the nylon wire clamps so that none of the wires can reach the fan blades.

The cooling fan should blow air into the control compartment. An arrow on the fan housing indicates the direction of air flow.

– 2 –

COMPONENT REPLACEMENT

1.Remove the access panel on the left side.

2.Remove all screws holding down the cover.

3.Lift cover straight up.

Replacement of the voltage regulator, actuating switch, main terminal block, or the contactor (1048 only) will require removing the component mounting plate.

1.Disconnect the wires from the on pilot light and the switches.

2.Tag or mark the wires to ensure correct replacement.

3.Remove the two mounting screws.

One is located at the bottom left of the voltage regulator.

The other is located under the lower part of the cooling fan. This screw can be reached through the blades of the fan.

4.Remove the component mounting plate and replace the component. Make sure that the screw that operates the actuating switch is above the switch lever.