Vulcan-Hart VB 25, VB 21, ML-052314, ML-052313, ML-052312 User Manual

0 (0)
Vulcan-Hart VB 25, VB 21, ML-052314, ML-052313, ML-052312 User Manual

INSTALLATION &

OPERATION MANUAL

HEAVY DUTY ELECTRIC BROILER SERIES

MODELS

 

VB 21

ML-052312

VB 21C

ML-052312

VB 25

ML-052313

VB 73

ML-052249

VB 221

ML-052315

VB 221C

ML-052315

VB 225

ML-052316

VTMB 221

ML-052314

VTMB 221C

ML-052314

VTMB22

VULCAN - HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791

FORM 31065 (5-98)

TABLE OF CONTENTS

 

GENERAL .........................................................................................................................................

3

INSTALLATION ..................................................................................................................................

4

Unpacking .....................................................................................................................................

4

Installation Codes and Standards .................................................................................................

4

Location .........................................................................................................................................

4

Electrical Connections ...................................................................................................................

4-5

Electrical Data Chart .....................................................................................................................

5

Electrical Tests ...............................................................................................................................

6

Leveling .........................................................................................................................................

6

OPERATION .......................................................................................................................................

7

Controls .........................................................................................................................................

7

Before First Use ............................................................................................................................

8

Using the Broiler ............................................................................................................................

8

Using the Oven ..............................................................................................................................

8-9

Time, Temperature & Switch Chart for Baking ...............................................................................

10

Cleaning ........................................................................................................................................

11

MAINTENANCE .................................................................................................................................

12

Service and Parts Information .......................................................................................................

12

– 2 –

Installation, Operation and Care of

MODELS VTMB22, VTMB2, VB2S & VB21

HEAVY DUTY ELECTRIC BROILERS

KEEP THESE INSTRUCTIONS FOR FUTURE USE

GENERAL

Your Vulcan-Hart Heavy Duty Electric Broiler is produced with quality workmanship and material. Proper installation, usage and maintenance of your broiler will result in many years of satisfactory performance.

Vulcan-Hart Company suggests that you thoroughly read this entire manual and carefully follow all of the instructions provided.

Model VB Ovens are provided with one rack as standard equipment.

MODEL

DESCRIPTION

VB 21

Single section broiler with standard oven below

VB 25

Single section broiler with storage space below

VB 225

Double section broilers with storage space below

 

 

VTMB 2

Modular single section broiler

 

 

VTMB 22

Modular double section broiler

 

 

VB 73

Backshelf broiler for mounting over a 3-ft. (91 cm) range

 

 

VB 21C

Single section broiler with convection oven below

VB 221

Double section broiler with standard oven below

VB 221C

Double section broilers with convection oven below

– 3 –

INSTALLATION

UNPACKING

Immediately after unpacking, check for possible shipping damage. If the broiler is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.

Remove all shipping wire, wood blocking, and accessories.

Before installing, verify that the electrical service agrees with the specifications on the rating plate located as follows: VTMB units - on the control panel front; VB21 - behind the oven door on the breaker box cover; and VB2S - behind the door panel of the storage cabinet base. If the supply and equipment requirements do not agree, contact your dealer or Vulcan-Hart immediately.

INSTALLATION CODES AND STANDARDS

Your Vulcan broiler must be installed in accordance with:

1.State and local codes, or in the absence of local codes, with:

2.National Electrical Code ANSI/NFPA-70 (latest edition).

LOCATION

Position the broiler in its installation position. The area around the broiler should be kept free and clear of all combustible materials.

ELECTRICAL CONNECTIONS

WARNING: ELECTRICAL AND GROUNDING APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODES.

CONNECTIONS MUST COMPLY WITH THE ELECTRICAL CODE AND/OR OTHER LOCAL

WARNING: DISCONNECT THE ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.

Bring conduit containing the proper supply wire (size and type in accordance with latest edition of the National Electrical Code ANSI/NFPA-70) to the broiler. Use wire suitable for 167°F ( 75°C) on broilers carrying more than 80 amps. On Models VB2S, VB22S, VB21 and VB221, the conduit enters into the broiler through the 2" (51mm) hole located in the bottom of the broiler. On Models VTMB2 and VTMB22, the conduit enters through the clearance hole provided in the back and is terminated on the vertical panel behind the terminal block.

Connect the supply leads to the terminal block and the green grounding lead to the labeled ground lug.

Broilers designed for 220/380 or 240/415 volts require voltage supplies with grounded neutral (3 phase, 4 wire; or 1-phase, 3-wire).

– 4 –