Vulcan-Hart 2GR45MF, 1GR85MF, 1GR45MF, 1GR65M, 2GR85MF User Manual

...
0 (0)
Vulcan-Hart 2GR45MF, 1GR85MF, 1GR45MF, 1GR65M, 2GR85MF User Manual

INSTALLATION &

OPERATIONAL MANUAL

GRM SERIES GAS FRYERS

MODELS:

1GR35M

ML-136407

1GR45M

ML-136408

1GR65M

ML-136409

1GR85M

ML-136410

1GR45MF

ML-136785

1GR65MF

ML-136786

1GR85MF

ML-136787

2GR45MF

ML-136417

2GR65MF

ML-136418

2GR85MF

ML-136419

3GR45MF

ML-136420

3GR65MF

ML-136421

3GR85MF

ML-136422

4GR45MF

ML-136423

1GR45M Shown

For additional information on Vulcan-Hart or to locate an authorized parts

and service provider in your area, visit our website at www.vulcanequipment.com

VULCAN-HART

3600 NORTH POINT BLVD.

DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC

BALTIMORE, MD 21222

WWW.VULCANEQUIPMENT.COM

F-31233 REV. K (February

2011)

GRM SERIES GAS FRYERS

IMPORTANT FOR YOUR SAFETY

THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.

POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER.

IMPORTANT

IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT THE MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE.

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.

VULCAN-HART

F-31233 Rev. K (February 2011)

-2-

GRM SERIES GAS FRYERS

TABLE OF CONTENTS

IMPORTANT FOR YOUR SAFETY………………………………………. 2

INTRODUCTION……………………………………………………………

4

GENERAL……………………………………………………………

4

ORDERING PARTS………………………………………………… 4

FRYER CAPACITIES……………………………………………….

4

UNPACKING………………………………………………………… 4

INSTALLATION…………………………………………………………….

5

Clearances…………………………………………………....5

Location ………………..……………………………….….

6

CODES AND STANDARDS……………………………………….. 6

ASSEMBLY …………..……………………………………………

6

FLUE CONNECTION……………………………………………….

7

GAS CONNECTION…………………………………………………. 7

Quick-Disconnect for Units on Casters…………………… 7

GAS PRESSURE......................................................................... 8

TEST GAS SUPPLY………………………………………………… 8

FRYERS WITH CASTERS………………………………………… 8

LEVELING THE FRYER…………………………………………… 9

OPERATION………………………………………………………………… 9

OVER-TEMPERATURE SHUTDOWN……………………………. 9

BEFORE FIRST USE………………………………………………... 10

Cleaning…………………………………………………….... 10

FILLING TANK WITH SHORTENING……………………………

10

LIGHTING THE PILOT

11

TURNING ON THE FRYER …….

12

TURNING OFF THE FRYER

12

EXTENDED SHUTDOWN………………………………………….. 12

BASIC FRYING INSTRUCTIONS………………………………….. 12

Fry Basket Guidelines………………………………………. 12

EXTENDED SHORTENING LIFE…………………………………

13

DRAINING THE TANK…………………………………………….

13

DAILY FILTERING-ALL MODELS………………………………. 14

CLEANING………………………………………………………….

14

Daily…………………………………………………………. 14

BOIL OUT PROCEDURE………………………………………………....

15

KLEENSCREEN PLUS® INSTALLATION & OPERATION MANUAL.... 16

GAS KLEENSCREEN PLUS® MODELS………………………….. 16

FILTERING INSTRUCTIONS FOR KLEENSCREEN PLUS® FRYERS… 17

GENERAL …………………………………………………………… 17

ASSEMBLY……………………………………………………………. 17

OPERATION…………………………………………………………………… 20

FILTERING PROCEDURE……………………………....

20

FILTERING TIP…………………………………………………….

21

REMOVING EXCESS DEBRIS FROM THE FILTER………….. 21

FLUSH AND DISCARD…………………………………………….. 22

BOIL OUT PROCEDURE………………………………………

22

THERMAL OVERLOAD PROTECTION RESET BUTTON……

23

MAINTENANCE…………………………………………………………..

23

FLUE VENT INSPECTION………………………………………..

23

Service in the US and Canada…………………………………...

23

In Australia………………………………………………………….

23

TROUBLESHOOTING……………………………………………………..

23

Troubleshooting Chart………………………………………………. 24

VULCAN-HART

F-31233 Rev. K (February 2011)

-3-

GRM SERIES GAS FRYERS

INTRODUCTION

GENERAL

Vulcan Fryers are produced with quality workmanship and material. Proper installation, usage and maintenance will result in years of satisfactory performance.

Before installing the fryer, thoroughly read this manual and carefully follow all instruction.

This manual is applicable to model listed on the cover page. Procedures in this manual will apply to all models unless specified. Pictures and illustrations can be of any model unless the picture or illustration needs to be model specific.

ORDERING PARTS

Customers may order parts directly from their local authorized service center. If not known, call Vulcan Customer Service at 800-814-7028.

To speed up your order, provide the model number, serial number, gas type, part needed, item part number (if known) and quantity needed.

FRYER CAPACITY

MODEL -

# of Heat Tubes

BTU / Hour

Width Inch (cm)

Shortening lbs. (kg)

GMO

Each Fry Tank

Each Fry Tank

Total System

Each Fry Tank

 

 

 

 

 

1GR35M

3

90,000

15.5" (39)

35-40 (16-18)

1GR45M (F)

4

120,000

15.5" (39)

45-50 (21-23)

1GR65M (F)

5

150,000

21.0" (53)

65-70 (29-32)

1GR85M (F)

5

150,000

21.0" (53)

85-90 (39-41)

2GR45MF

4

120,000

31.0" (79)

45-50 (21-23)

3GR45MF

4

120,000

46.5" (118)

45-50 (21-23)

4GR45MF

4

120,000

62.0" (158)

45-50 (21-23)

2GR65MF

5

150,000

42.0" (107)

65-70 (29-32)

3GR65MF

5

150,000

63.0" (160)

65-70 (29-32)

2GR85MF

5

150,000

42.0" (107)

85-90 (39-41)

3GR85MF

5

150,000

63.0" (160)

85-90 (39-41)

 

 

 

 

 

 

 

 

 

 

UNPACKING

This fryer was carefully inspected before leaving the factory. Upon acceptance of the shipment, the transportation company assumes full responsibility for safe delivery.

Immediately after unpacking the fryer, check for possible shipping damage. If the fryer is damaged, save the packaging material and contact the carrier within 15 days of delivery.

VULCAN-HART

F-31233 Rev. K (February 2011)

-4-

GRM SERIES GAS FRYERS

Check that the following have been included:

Crumb Rack

Basket Hanger

Twin Fry Baskets (2)

Tank Brush

Adjustable Casters (4) two locking, two non-locking for freestanding fryers. Fryer

Batteries with the KleenScreen PLUS® Filtration System have casters installed from the factory.

Drain Pipe Extension for freestanding fryers only.

Cleanout Rod for freestanding fryers only.

Crumb Scoop for freestanding fryers only.

Manual and Warranty

Fryer Batteries with the KleenScreen PLUS® Filtration System

Filter Pan

Suction Tube

Screen Assembly

Complimentary Pack of Micro-Filtration Envelopes

6’ high temperature discard hose

Do not use the door or its handle to lift the fryer.

INSTALLATION

Before installing the fryer, verify that the type of gas (natural or propane) agrees with the specifications on the fryer data plate, which is located on the inside of the door panel.

Make sure the fryer is configured for the proper elevation.

Record your fryer model, device, and serial numbers for future reference in the space provided below. This information can be found on the fryer data plate.

Fryer Model No: ___________________________

Device:___________________________________

Serial No: ________________________________

Clearances

Minimum clearance from combustible construction:

6” (15 cm) from the sides of the fryer

6” (15 cm) from the back of the fryer

The fryer may be installed on combustible floors

VULCAN-HART

F-31233 Rev. K (February 2011)

-5-

GRM SERIES GAS FRYERS

Minimum clearance from noncombustible construction:

0” from the sides of the fryer 0” from the back of the fryer

Between the fryer and any open-top flame units: 16” (41 cm)

Allow space for servicing and operation.

Location

Install fryer in an area with sufficient air supply for gas combustion at fryer burners.

Do not obstruct the flow of combustion and ventilation air.

Provide adequate clearance for air openings into the combustion chamber.

Do not permit fans to blow directly onto fryer.

Avoid wall-type fans, which create cross-currents within a room. Avoid open windows next to sides or back.

CODES AND STANDARDS

The fryer must be installed in accordance with:

In the United States:

State and local codes, or in the absence of local codes, with:

National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). Copies may be obtained from The American Gas Association Accredited Standards

Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-

7471.

NFPA Standard #96 Vapor Removal from Cooking Equipment, latest edition, available from the National Fire Protection Association, Batterymarch Park,

Quincy, MA.

In the commonwealth of Massachusetts all gas appliances vented through a ventilation hood or exhaust system with a damper or with a power means of exhaust shall comply with 248 CMR.

In Canada:

Local codes

CAN/CSA-B149.1 Natural Gas and Propane Code Installation (latest edition), available from the Canadian Gas Association 350 Sparks Street, Ottawa, Ontario Canada K1R 7S8.

CSA C22.1 Canadian Electric Code L4W 5N6.

VULCAN-HART

F-31233 Rev. K (February 2011)

-6-

GRM SERIES GAS FRYERS

ASSEMBLY

The fryer must be restrained to prevent tipping and the splashing of hot liquid. The means of restraint may be the manner of installation, such as connection to a battery of appliances, installing the fryer in an alcove, or by separate means such as adequate ties.

FLUE CONNECTION

Make the flue connection as follows:

Comply with Vapor Removal from Cooking Equipment, ANSI-NFPA Standard #96

(latest edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

Locate the fryer under a hood with adequate connection to an exhaustduct. The hood must extend 6” (15 cm) beyond fryer on both sides.

Clearance above the fryer should be adequate for combustion byproducts to be removed efficiently.

An 18” (46 cm) minimum clearance should be maintained between the flue vent and the filters of the hood venting system.

Never make flue connections directly to the fryer.

Do not obstruct the flow of the gases from the appliance. Proper air balance should be maintained in the room.

Ensure that your ventilation system does not cause a down draft at the fryer’s flue opening. Down draft will not allow the fryer to exhaust properly and will cause overheating which may cause permanent damage. Damage caused by down draft will not be covered under equipment warranty. Never allow anything to obstruct the flue or ventilation exiting from the fryer flue. Do not put anything on top of flue area.

GAS CONNECTION

All gas supply connections and any pipe joint compound must be resistant to the action of propane gases.

The gas inlet is located on the lower rear of the fryer. Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer.

The gas supply line must be at least the equivalent of ½” (12.7 mm) iron pipe for single units and 1-1/4” (31.75 mm) for batteries. If using the optional quick-disconnect flex hose, ¾” (19 mm) iron pipe for single units and 1-1/4” (31.75 cm) iron pipe for batteries.

Make sure the pipes are clean and free of obstructions, dirt, and piping compound. A battery requires one or two connections of appropriate size for the gas requirement.

VULCAN-HART

F-31233 Rev. K (February 2011)

-7-

GRM SERIES GAS FRYERS

Prior to lighting, check all joints in the gas supply line for leaks.

Use soap and water solution. Do not use an open flame.

After piping has been checked for leaks, fully purge gas pipes to remove air.

GAS PRESSURES (ALL MODELS):

The gas pressure should be set at 4” W.C. (Water Column) (0.8 kPa) for natural gas and

10” W.C. (2.75 kPa) for propane gas. If incoming pressure exceeds ½ PSI (3.45 kPa), an additional pressure regulator must be installed.

TESTING THE GAS SUPPLY PIPING SYSTEM:

When test pressures exceed ½ PSI (3.45 kPa), the fryer and its individual shutoff valve must be disconnected from the gas supply piping system.

When test pressures are ½ PSI (3.45 kPa) or less, the fryer must be isolated from the gas supply piping system by closing its individual shutoff valve.

Fryers with Casters:

Separate instructions for installing casters are included with the casters:

The installation shall be made with a connector that complies with the

Standard for Connectors for Movable Gas Appliances, ANSI Z21.69, CAN/CGA-

6.16, and a quick-disconnect device that complies with the Standard for QuickDisconnect Devices for Use with Gas Fuel, ANSI z21.41 CSA 6.9 or QuickDisconnect Devices for Use with Gas Fuel,

When installing a quick disconnect you must also install a means for

limiting the movement of the fryer. This device will prevent the gas line or quick disconnect from being strained. The restraining device should be attached to the cutout on the back panel. See illustration for location.

VULCAN-HART

F-31233 Rev. K (February 2011)

-8-