Vinotemp VINO6500SSH, WM-25SFCH, WM-850SCU, WM-45SFCH, WM-85SFCH User Manual

...
0 (0)

WINE-MATE Split System

Installation, Operation & Care Manual

VINO2500SSH, 4500SSH

VINO6500SSH, 8500SSH

Vinotemp International Corp.

www.winemate.com

READ AND SAVE THESE INSTRUCTIONS

TABLE OF CONTENTS

Important Safety Information…..........................................2

Feature Description…………………………….……………..3

Cellar Construction.…………………………….……………..6

Installer’s Instruction…………….…..….……..……………..7

Temperature Control & Humidity Adjustment.………….15

Care Guide…………………………………………………….20

User’ Troubleshooting…….………………………………...21

Customer Support……………………………………………23

Warranty……………………………………………………….24

- 1 -

Vinotemp VINO6500SSH, WM-25SFCH, WM-850SCU, WM-45SFCH, WM-85SFCH User Manual

Important Safety Information

DO NOT USE A GROUND FAULT INTERRUPTER (GFI).

A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED.

-2 -

Feature Description

Wine-Mate split cooling systems VINO2500-8500SSH are designed and used to provide a cold temperature between 50~65 °F for a properly insulated wine room at a normal environment.

The wine room will maintain humidity of 50~70% RH even when the environment becomes dry and humid. These temperatures and humilities are optimized for long term storage of wine.

SSH units consist of a condensing unit and an evaporator unit, and they are connected by a liquid line and an insulated suction line.

SSH condensing units can be located away from the evaporator units and wine cellars as far as 50 feet, which will bring you quiet operation.

The SSH evaporator units are designed to provide chilled air to wine rooms through ducts and can be located up to 25 ft away to reduce noise.

The dimensions and capacities are specified as follows:

 

EVAP UNIT

COND UNIT

Btu/h

BOTTLE

 

ELECTRICAL

WEIGHT(lb)

MODEL

(55/90°F)

CAPACITY

REFRIGERANT

EVAP UNIT/

EVAP UNIT/

L”xH”xW”

L”xH”xD”

(55/75°F)

 

 

 

CFM

 

COND UNIT

COND UNIT

VINO-

WM-25SFCH

WM-250SCU

 

250

1200

 

115V-60HZ-

 

22.5x14.375x

2500/220

R134a

0.8A / 115V-

30/40

2500SSH

18x14x12

cu ft

bottles

15.875

 

 

60HZ-5.7A

 

 

 

 

 

 

 

 

VINO-

WM-45SFCH

WM-450SCU

 

1000

4500

 

115V-60HZ-

 

25.125x16.375

4500/380

R134a

1.8A / 115V-

39/60

4500SSH

18x14x12

cu ft

bottles

x22.875

 

 

60HZ-6.9A

 

 

 

 

 

 

 

 

VINO-

WM-65SFCH

WM-650SCU

 

1500

6500

 

115V-60HZ-

 

25.125x20.375

6500/490

R134a

1.8A / 115V-

48/90

6500SSH

24x17x18

cu ft

bottles

x22.875

 

 

60HZ-12A

 

 

 

 

 

 

 

 

VINO-

WM-85SFCH

WM-850SCU

 

2000

8500

 

115V-60HZ-

 

27.125x22.375

8500/750

R134a

2.1A / 115V-

58/115

8500SSH

24x17x18

cu ft

bottles

x22.875

 

 

60HZ-15A

 

 

 

 

 

 

 

 

- 3 -

Fig. 1.1 WM25-85SFCH Evaporator Unit

Fig. 1.2 WM250-450SCU Condensing Unit

- 4 -

Fig. 1.3 WM650-850SCU Condensing Unit

- 5 -

Cellar Construction

This is only a guide and shall be considered as minimum requirements.

All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation. The vapor barrier shall be installed on the warm side of the insulation. All joints, door frames, electrical outlets or switches and any pipes or vents that go through the enclosure shall be sealed to prevent air and moisture leakage into the room. Concrete, rock, and brick are not insulation or vapor barriers.

Doors shall be of a minimum size, insulated to at least R11 and tightly sealed with high quality weather stripping. Be sure to seal the bottom of the door and fill gap between the door’s frame and wall before installing the cap molding.

In order to maintain 55 °F in the wine cellar, the ambient temperature surrounding the enclosure shall not exceed the temperature of the enclosure by more than 25 °F. No enclosure wall shall receive direct sun or strong wind.

Lighting shall be of low wattage, with a timer to insure lights are not left on when the enclosure is not occupied.

The cooling system will not be able to maintain the proper temperature if fresh moisture-laden air is constantly being introduced to the enclosure. Symptoms of this condition are; unit runs all the time with only a slight reduction in temperature and/or water overflows from the unit. Because of the temperature difference between the inside and outside, very small cracks can allow large amounts of outside air to enter into the enclosure. Please be aware that moisture can pass through solid concrete, paint and wood. Often a newly constructed room contains fresh wood, paint, concrete and other building materials. These materials contain large amounts of moisture. When placed into operation in this type of environment, the system will work harder to remove this extra moisture resulting in increased “run” time.

- 6 -

Installer’s Instruction

Federal law requires that WINE-MATE split cooling systems be installed by an EPA certified refrigeration technician.

WINE-MATE split system is shipped as components and is ready for use only after a certified refrigeration technician has properly installed, charged and tested the system. Proper installation is critical. Vinotemp can only warrant the quality of the components. The installation and proper operation of the system must be warranted by the installer. Installation of the system must be done in accordance with all state and local building codes.

The condensing unit and evaporator unit are connected by a liquid line and an insulated suction line that are supplied by the installer. These lines must be properly sized for the distance between the two units. After the units and the lines are installed, the system must be pressure tested. If no leaks are found, evacuate and charge system with R134A. Refrigerant amount will vary depending on the length of line set.

Fig. 2.1 SSH Split System Installation

- 7 -