The K-1900-8-IP VoIP panel phone can either auto-dial a phone number each time the handset is lifted, be used as a
multi-number auto-dialer, or be used as a standard manual dial phone. The K-1900-8-IP VoIP phone is designed to
provide quick and reliable communication for SIP VoIP phone systems with PoE. The unit can be programmed from any
PC on the same LAN or remotely using a Static IP Address. The K-1900-8-IP phone can dial up to 250 programmable
numbers and another 250 rollover numbers.
When a call initiated by the K-1900-8-IP phone is answered by an apartment or business tenant, a built-in contact closure
may be activated to control an electric gate or door strike. Up to 1,000 keyless entry codes may be programmed, providing
tenants with keyless entry. A 26 Bit Wiegand input is provided for adding an optional proximity card reader with capacity
to program up to 1,000 card numbers. Keyless entry codes and card numbers can be programmed to only allow access
at specific times and/or day of the week. A request for exit (REX) input is included for easy exiting. The K-1900-8-IP also
has automatic event logging allowing you to review the time and date of the call, which door was open/closed, what
keyless entry code or proximity card was used, request for exit usage and whether it was an inbound or outbound call.
The K-1900-8-IP-EWP shares all of the features of the K-1900-8-IP in addition to Enhanced Weather Protection (EWP)
for outdoor installations where the unit is exposed to precipitation or condensation. EWP products feature foam rubber
gaskets, sealed connections, gel-filled butt connectors, as well as urethane or thermal plastic potted circuit boards. For
more information on EWP, see DOD 859.
Installation requires the assistance of a Network Administrator / IT Technician
!
K-1900-8-IP and
K-1900-8-IP-EWP
VoIP Phone with Auto Dialer,
Keypad, and Entry System
August 20, 2018
Marine grade brushed
316 stainless steel
(similar to brushed nickel)
Shown above in optional
Viking VE-5X10 Surface
Mount Box, not included
Features
• Vandal Resistant Features: 12 gauge 316 stainless steel faceplate with permanent
laser etched graphics. Heavy duty metal keypad, hook switch, armored cable and T-10
security Torx drive mounting screws.
• Weather Resistant Features: Marine grade 316 stainless steel faceplate and Torx
security screws. Internally sealed keypad. Faceplate gaskets (on EWP models).
Weather resistant powder paint on optional VE-5X10 surface mount box or 316 grade
stainless steel on optional VE-5X10-SS surface mount box.
• Ring with adjustable volume and cadence
• Hearing aid compatible amplified handset with sealed push button volume control
• Two sets of SPDT 2 Amp relay contacts for door/gate or camera control
• Optional RC-4A for Secure Remote Relay Control, see DOD 582
• SIP compliant (see page 2 for list of compatible IP-PBX phone systems)
• PoE powered (class 2, <6.5 watts)
• Network downloadable firmware
• 36” armored handset cable on Standard model, 54” on EWP model
• Programmable to speed dial up to 250 numbers
Applications
• Apartment Entry Phone
• Commercial Gate Entrance
• Courtesy Assistance Phone
• Customer Service Phone
• Use with Viking PRX-1 (DOD 221) or PRX-3 (DOD 228)
Proximity Card Readers
• Use with Viking LRT-4 Long Range Transmitter (DOD 226)
• Hot-Line Phone
• Door Entry Phone
• Kiosk Phone with up to
250 number speed dialing
www.VikingElectronics.com
Information: 715-386-8861
• 26 Bit Wiegand input for optional proximity card readers, see DOD 221 and 228
• 26 Bit Wiegand output connect to card reader input of an Access Control System
• Cycles to rollover phone number on busy or no-answer
• Program up to 1,000 keyless entry codes and/or proximity card numbers
• Keyless entry codes and proximity card numbers can be programmed to only allow
access at specific times and day of week
• Event logging with time and date stamp
• Optional Enhanced Weather Protection (EWP), EWP products are designed to meet IP66
Ingress Protection Rating, see DOD 859
• Remotely programmable
• Extended temperature range (-40°F to 140°F)
• Zinc plated steel rough-in box included
• Optional VE-5x10 and VE-5X10-SS Surface Mount Boxes, see DOD 424
• Optional VE-LIGHT kit to illuminate the front panel at night, see DOD 428
• Diagnostics (for testing relays)
Specifications
Power: PoE class 2 (<6.5 watts)
Dimensions for Standard Model
Phone only: 5.0” x 10.0” x 4.68” (127mm x 254mm x 119mm)
Including rough-in box: 5.0” x 10.0” x 5.53” (127mm x 254mm x 141mm)
Dimensions for EWP Model
Phone only: 5.0” x 10.0” x 4.75” (127mm x 254mm x 121mm)
Including rough-in box: 5.0” x 10.0” x 5.61” (127mm x 254mm x 143mm)
Shipping Weight: 3.5 lbs (1.6 kg)
Operating Temperature: -40°F to 140°F (-40° C to 60° C)
Humidity - Standard Model: 5% to 95% non-condensing
Humidity - EWP Model: Up to 100%
Audio Codecs: G711u, G711a, G722
Network Compliance: IEEE 802.3 af PoE, SIP 2.0 RFC3261, 100BASE-TX with
auto cross over
Regulatory Compliance: CE, FCC Part 15 and Canada ICES-003 Class A
Connections: (1) RJ45 10/100 Base-T, (14) gel-filled butt connectors
Page 2
Viking VoIP SIP System Compatibility List
NOTE: Exclusion from this list means only that compatibility has not been verified, it does not mean incompatibility.
For detailed configuration instructions for certain vendors below, see Configuring Viking VoIP Phone and SIP
Servers, DOD 944.
* Note: Relay operation commands are Not compatible with Panasonic Phone Systems (Panasonic does not transmit DTMF between station ports).
2
Page 3
Definitions
Client: A computer or device that makes use of a server. As an example, the client might request a particular file from the server.
DHCP: Dynamic Host Configuration Protocol. In this procedure the network server or router takes note of a client’s MAC address and
assigns an IP address to allow the client to communicate with other devices on the network.
DNS Server: A DNS (Domain Name System) server translates domain names (ie: www.vikingelectronics.com) into an IP address.
Ethernet: Ethernet is the most commonly used LAN
achieve transmission speeds up to 1Gbps.
Host: A computer or device connected to a network.
Host Name: A host name is a label assigned to a device connected to a computer network that is used to identify the device in various
forms of network communication.
Hosts File: A file stored in a computer that lists host names and their corresponding IP addresses with the purpose of mapping addresses
to hosts or vice versa.
Internet: A worldwide system of computer networks running on IP
IP: Internet Protocol is the set of communications conventions that govern the way computers communicate on networks and on the
Internet
IP Address: This is the address that uniquely identifies a host on a network.
LAN: Local Area Network. A LAN is a network connecting computers and other devices within an office or building.
Lease: The amount of time a DHCP
time, the lease can expire and the address can be assigned to another host.
MAC Address: MAC stands for Media Access Control. A MAC address, also called a hardware address or physical address, is a unique
address assigned to a device at the factory. It resides in the device’s memory and is used by routers to send network traffic to the correct
IP address. You can find the MAC address of your K-1900-8-IP phone printed on a white label on the top surface of the PoE LAN port.
Router: A device that forwards data from one network to another. In order to send information to the right location, routers look at IP
Address, MAC Address and Subnet Mask.
RTP: Real-Time Transport Protocol is an Internet protocol standard that specifies a way for programs to manage the real-time transmission
of multimedia data over either unicast or multicast network services.
Server: A computer or device that fulfills requests from a client. This could involve the server sending a particular file requested by the
client.
Session Initiation Protocol (SIP): Is a signaling communications protocol, widely used for controlling multimedia communication sessions
such as voice and video calls over Internet Protocol (IP
which govern establishment, termination and other essential elements of a call.
Static IP Address: A static IP Address has been assigned manually and is permanent until it is manually removed. It is not subject to the
Lease
Subnet: A portion of a network that shares a common address component. On TCP/IP networks, subnets are defined as all devices
whose IP addresses have the same prefix. For example, all devices with IP addresses
same subnet. Dividing a network into subnets is useful for both security and performance reasons. IP networks are divided using a subnet
mask.
TCP/IP: Transmission Control Protocol/Internet Protocol is the suite of communications protocols used to connect hosts on the Internet.
TCP/IP uses several protocols, the two main ones being TCP and IP. TCP/IP is built into the UNIX operating system and is used by the
Internet, making it the de facto standard for transmitting data over networks.
TISP: Telephone Internet Service Provider
WAN: Wide Area Network. A WAN is a network comprising a large geographical area like a state or country. The largest WAN is the
Internet
Wireless Access Point (AP): A device that allows wireless devices to connect to a wired network using Wi-Fi, or related standards. The
AP usually connects to a router (via a wired network) as a standalone device, but it can also be an integral component of the router itself.
Wireless Repeater (Wireless Range Extender): takes an existing signal from a wireless router or access point and rebroadcasts it to
create a second network. When two or more hosts have to be connected with one another over the IEEE 802.11 protocol and the distance
is too long for a direct connection to be established, a wireless repeater is used to bridge the gap.
.
server reserves an address it has assigned. If the address isn’t used by the host for a period of
limitations of a Dynamic IP Address assigned by the DHCP Server. The default static IP Address is: 192.168.154.1
.
technology. An Ethernet Local Area Network typically uses twisted pair wires to
protocol which can be accessed by individual computers or networks.
) networks. The protocol defines the messages that are sent between endpoints,
that start with 100.100.100. would be part of the
3
Page 4
Features Overview
Front View of the
K-1900-8-IP VoIP Phone
Mounting Screws:
Marine grade 316 stainless steel,
flat head, T-10 Torx security
screws and drive bit (included).
(8) 6-32 X 3/4”
Hearing Aid
Compatible amplified
handset with sealed
push button
volume control
316 Stainless Steel
Armored Cable:
36” on K-1900-8-IP,
54” on K-1900-8-IP-EWP
Laser Etched Graphics:
For long lasting easy to read graphics.
To Handset
26 Bit Wiegand Input / Output
For connecting optional Proximity Card Readers,
see Viking models below right (not included)
or program as a output to connect to the card
reader input of an Access Control System
To Hookswitch
VE-LIGHT, etc.
12 VDC Power Output for
Relay 2 Output Contacts
(2A@30VDC/ 250VAC max)
(12VDC @ 50mA max)
Request for Exit
(REX) Input
- Black
+ Red
Green
Green
COM.
N.C.
N.O.
Black
Black
Yellow
Yellow
Red
Red
White
Green
+ Red
- Black
Black
Red
Brown
Violet
White
VIKING
2
ABC
JKL
TUV
OPER
3
DEF
6
5
MNO
8
9
WXY
0
#
GHI
PRS
1
4
7
Rear (PCB) View of the
K-1900-8-IP VoIP Phone
Metal Heavy duty Vandal
Resistant Hookswitch
Faceplate Material: 12 gauge 316
stainless steel with a #4 brushed
finish.
Sealed Metal Keypad
Condensation Drain Hole
PoE LAN Port 10/100,
PoE Class 2 (<6.5 Watts):
Connect to your LAN via
MAC:
asdesaxtff
18E80FXXXXXX
RJ45 plug and CAT5 or
greater twisted pair wire.
MAC Address Label: The
MAC address is a unique
12 digit number used by
routers to send network
traffic to the correct IP
address.
Yellow Network Status
LED: Lights steady to
indicate power and data
link. Blinks to indicate
network activity.
Connect to Optional
Doorstrike, Mag Lock,
Gate Controller, etc.
120V AC
connected)
(not
Relay 1
Output Contacts
(2A@30VDC/ 250VAC max)
N.C. (Gray)
Optional Viking Proximity Card Readers
Model PRX-1
Proximity Card
Reader DOD# 221
Green Unit Status LED
Model PRX-3 Medium
Range Proximity Card
Reader DOD# 228
COM. (Blue)
Doorstrike /
Magnetic Lock
(Power typically not
required for gate controllers)
N.O. (Yellow)
* 3 Gel-Filled Butt
Connectors (included)
Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of 0.082 inches.
4
Page 5
Installation and Mounting
To install the K-1900-8-IP panel phone, attach the panel using the provided screws or use the optional VE-5x10 or VE5X10-SS weather resistant surface mount box. Note: Four extra screws and nuts are provided to fill the unused mounting
holes. The optional VE-5x10 (shown below) or VE-5X10-SS surface mount box is designed to be surface mounted to a
wall, post, single gang box or a VE-GNP or VE-GNP-2 goose neck pedestal (shown right). The K-1900-8-IP can also be
mounted in an optional VE-9x20 Weatherproof Enclosure (DOD# 413). Note: When mounting a K-1900-8-IP-EWP in a
VE-9x20, the length of the handset cable must be reduced. Use a 3/32” hex key or bit to loosen the set screw in the brass
handset cable retainer. Pull approximately 18 inches of the cable through the panel and retighten the set screw.
NOTE: Write down the MAC Address (found on the RJ-45 jack) as this may be needed to identify the unit after installation.
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone
line. It is recommended that a surge protector be installed to protect against such surges.
Earth Ground the
Green/Yellow wire
using the
provided wire nut
Zinc-Plated
Steel Rough-In
Box (included)
2.5"
5.5"
OR
3.69"
5.22"
4.5"
Earth
Ground
Side View of the
K-1900-8-IP
(8) #6-32 x 3/4" Stainless
Steel T-10 Torx security
screws (included)
10.0"
Front View of the
K-1900-8-IP
1.72"
5.12"
9.5"
5.00"
4.50"
0.23"
4.04"
10.14"
The optional VE-5x10 (left) or VE-5x10-SS
Surface Mount Box are designed to be
surface mounted to a single gang box,
double gang box, or VE-GNP Gooseneck
Pedestal (shown right). For more information on the VE-5x10, VE-5 x10-SS and
VE-GNP, see DOD# 424.
K-1900-8-IP-EWP shown
with VE-5x10 Surface
Mount Box and VE-GNP
Gooseneck Pedestal
(not included)
5
Page 6
Using a Viking Model RC-4A for Secure Remote Relay Control
The front panel of the K-1900-8-IP is mounted using security Torx screws to help prevent intruders from removing the panel
and accessing the on board door strike/gate control relays. For applications requiring additional security, a Viking model
RC-4A remote relay controller can be used. The relay controller is mounted securely inside the building and connected to
the same LAN as the K-1900-8-IP. The on board door strike relays would not be used in this case as the K-1900-8-IP will
send an encrypted message to the RC-4A to activate its relays which control the door strikes/gates.
Up to 4 K-1900-8-IP’s can communicate with one RC-4A allowing you to securely control four entrances.
When using a RC-4A for remote relay control, the K-1900-8-IP’s relays should be set to “External” in the PC programming.
For more information, see DOD# 582 at www.VikingElectronics.com.
6
Page 7
Typical Installation on SIP Based VoIP Phone System
(Extends range of cable, keeps
1 Gbps network speed for other
equipment on network)
SIP VoIP PBX
or
PC with
SIP Server
Software
100m (328 ft) maximum*
Viking supplies
Customer’s
Responsibility
Internet
10/100 Mbps
Maximum
Viking
K-1900-8-IP
VoIP Phone
* Note: A PoE extender can be used for an additional 100 meters per extender. For longer runs (up to 2 km / 1.2 miles)
a ethernet to ber media converter can be used.
Windows 2000 (service pack 4 or higher)
Windows XP (service pack 2 or higher)
Windows Vista (SP2 or newer), 32 or 64 bit versions
and newer versions of Windows
• Adobe Acrobat Reader 8 or higher
• K-1900-8-IP hardware
• Available LAN with PoE (class 2, <6.5 watts)
• Ethernet cable ( CAT5 min.)
• 1 MB minimum free hard drive space for installation
• 16MB of free physical RAM
PC Programming
A DVD is included with each K-1900-8-IP VoIP Phone. The DVD contains the application “Viking IP Programming” used
to program the unit using a PC running Windows 2000, XP, Vista, Windows 7, Windows 8 or Windows 10 (see System
Requirements above). The PC must be connected to the same LAN as the K-1900-8-IP VoIP phone. Install the application
on your PC by placing the DVD into your PC’s drive. Click “I Accept” on the bottom of the first screen, then select “Viking IP
Programming” and click the “Install” button. Follow the directions on the screen. To start the Viking IP Programming
application, click on the Viking IP Programming icon on your desk top. The Main screen will appear, allowing the user to
program any K-1900-8-IP phone connected to that LAN.
7
Page 8
A. Connect/Disconnect
Open the “Viking IP Programming” software on the PC and the start screen shown below will appear. Any Viking IP
phones that are connected to the network will appear on the list. Simply select the K-1900-8-IP on the list and click on
the “Connect” button at the bottom or double click the selected phone. If the security code of the selected phone is still
set to default (845464), the PC software will not require entering a security code to connect to the phone. K-1900-8IP’s have a default name of “uCMK60_E_1600A_IP”, so if many phones are connected to the same network that all
have the default name, MAC addresses must be used to identify each phone.
When finished programming, click on the “Disconnect” button at the bottom. Closing the program will also automatically
disconnect the unit.
B. Manually Muting SIP/Network Failure Alarm Beeps (3 beeps repeated every 30 seconds)
With the unit connected and powered (Green LED on and Yellow LED off or blinking) it will output 3 beeps every 30
seconds in the handset of the K-1900-8-IP to indicate a SIP registration failure, failure to receive an echo reply from
pinged gateway or Ethernet connection failure. You can manually disable the beeps by pressing and holding the “Q”
button for 5 seconds (2 beeps will then be heard for confirmation). You can also manually disable the beeps by clicking
the “Mute Current / Next Alarm” button in the Viking IP programming software.
8
Page 9
C. Configuring the K-1900-8-IP Network Settings
Step 1.
Step 2.
Step 3. Click the “Connect” button. If a pop up window appears, enter the unit’s security code (factory set to 845464) then click “OK”.
Step 4. The program will then read and display the K-1900-8-IP phone’s IP and programming settings.
Step 5.
Open the “Viking IP Programming” software on a windows PC that is connected to the same LAN as the K-1900-8-IP phone to be
programmed.
The window in the upper left corner of the menu will show you each K-1900-8-IP phone that is connected to that LAN. Select the unit
with the same MAC address shown on the label located on the top of the Ethernet connector on the K-1900-8-IP phone.
Click on the “IP Settings” tab and fill in the three required fields of SIP Server, Username and Password. The SIP provider or the phone
system programmer provide the information to put in these fields. The SIP Server field can contain an IP address or a fully qualified
domain name. Some examples are shown below. Our phones use port “5060” for traffic by default but another port can be specified by
adding a “:” (colon) and the desired port number at the end of the SIP server IP address (for example “192.168.210.61:5070” to specify
port “5070”). You can also assign a name for the K-1900-8-IP in the Unit Name field. When finished, click on the “Apply” button to send
the IP settings to the connected unit. See Examples 1 and 2 of the required fields below:
Example 1: Panasonic TDE 100/200
D. Manually Resetting the Security Code to Enter Programming
Step 1. Power down the K-1900-8-IP phone by disconnecting the LAN Cable (RJ45 plug).
Step 2. Take the handset offhook, then reconnect the LAN Cable (RJ45 plug).
Step 3.
Step 4. The security code is now reset to 845464 (factory default).
Step 5. You can now enter programming by following the steps in section B above.
8-12 seconds after connecting the LAN Cable you should hear 2 beeps in the handset. Go back on-hook within 6 seconds and you
should hear 2 more beeps.
Example 2: Voip.ms
9
Page 10
E. Manually Resetting All Network Parameters to Factory Default
Step 1. Power down the K-1900-8-IP phone by disconnecting the LAN Cable (RJ45 plug).
Step 2. Take the handset offhook, then reconnect the LAN Cable (RJ45 plug).
Step 3.
Step 4. You can now enter programming by following the steps in section B above.
*Note: if you do not go back on-hook within 6 seconds, the handset will continue to beep until back on-hook. This indicates an error and network
parameters will remain unchanged.
8-12 seconds after connecting the LAN Cable you should hear 2 beeps in the handset. 6 seconds later you should hear 4 beeps, go
back on-hook within 6 seconds*. Unit will reset and 2 beeps will be heard in approximately 7 seconds.
Programming Features Index
DESCRIPTIONSectionPage
Connect/DisconnectA8
Phone Number Database111
Event Log212
Entry Code Database312
Phone Name413
Mute Current / Next Alarm513
Phone Firmware613
IP Firmware713
Import/Export813
Factory Default 913
Diagnostics (used to check communications, relays and proximity card reader operation) 1013
Security code (factory set to 845464) 1113
Access Code (1-6 digits, blank = disabled, factory set to 123456)1213
Inbound Call Mode (Disabled, Auto Answer, Auto Answer Secure, Ring-Low, Ring-High, Silent Monitor & Silent Monitor
Secure) (factory set to Auto Answer)
Ring Cadence (factory set to Normal Ring)1414
Phone Mode (Auto Dialer or Manual Dial Phone, factory Set to Auto Dialer)1514
Off Hook AutoDial1614
Off Hook Dialing Delay1715
Select Time Zone 1815
Daylight Savings1915
Keyless/Card Logging2015
Relay 1 or 2 Mode (Door Strike, Outbound Call, In/Outbound Call, Doorbell, Alarm Mode,Ring, Ring Flash, factory set to Door
Strike)
Relay 1 or 2 Activation Command (1 or 2 digits, factory set to QQ and Q2) (Relay Mode must be set to Door Strike)
Relay 1 or 2 Activation Time (0.5 - 99 sec, factory set to 5 sec)2316
Relay 1 or 2 Int/Ext (factory set to Internal) 2416
Relay Act. Delay (Disabled or 0.5 - 99 sec, factory set to Disabled)2516
Relay Latch Commands (Enabled or Disabled, factory set to Enabled)2616
In-Band Audio Call Progress (Enabled, Disabled, factory set to Enabled)2716
In-band Audio Detect Sensitivity (1-9, 1 = min, 9 = max, factory set to 5, power cycle unit after setting)2816
Call Length Time Out (disabled or 1 to 9 min, factory set to 3 min)2916
Dial Next Number on Ring No Answer (disabled, 1 - 9 = number of rings, factory set to 7)3017
Dial Next Number on Busy (disabled or enabled, factory set to enabled) 3117
Live Dialing Format (Inband DTMF or RFC2833, factory set to RFC2833)3217
REX Input3317
Wiegand Direction3417
1314
2115
2216
10
Page 11
Programming Features
1. Phone Number Database
Clicking on the “Phone Number Database” button will open a screen allowing you to program all the Tenants Name’s,
Speed Dial Numbers, and Primary and Roll Over phone numbers. Tenant names are stored locally on the PC and are
not uploaded.
The Speed Dial Number is the 1 to 3 digit number visitors enter on the K-1900-8-IP’s keypad for the unit to call the
tenant. 3 seconds after the 1 to 3 digit number is entered, the unit will then dial the Primary Phone Number associated
with that Speed Dial Number. If there is no answer or a busy signal is detected, the K-1900-8-IP will then dial the Roll
Over Phone Number.
The Primary Phone Number programmed in Index 0 is the number that is dialed when the handset is lifted and the
visitor does not dial any digits on the keypad before the “off hook dial delay” timer has expired ( if “Off Hook AutoDial”
is enabled). A second Roll Over Number will be dialed when there is no answer or a busy signal is detected. The K-1900-8-IP phone is factory set with no Primary or Roll Over numbers programmed.
Note: Typical Apartment Applications use the tenant’s 1 to 3 digit apartment number as the Speed Dial Number. After
the apartment number is entered the unit will then dial the tenant’s phone number.
11
Page 12
2. Event Log
The Event Log button is used to open the Event Log screen. The Event Log screen shows you the time and date of
each event, the event type, relay action (which door/gate was opened or closed), entry code index and phone number
index with tenant name. The Event Log can store up to 4,095 events. Events are stored in a first in first out format.
When the memory is full, new events will over write the oldest events. The Event log can be saved in one of two file
formats: Tab Delimited Text or Comma Separated Variable.
3. Entry Code Database
Clicking on the “Entry Code Database” button will open the Entry Code Database screen.
The Entry Code Database will then download. The Entry Code Database will allow you to program the Relay Function,
Relay 1 and/or 2, once only (one time use only), Entry Type (Card, Keyless or both), Keyless Code, Proximity Card #,
Facility Code, Day of week, Time of Day and Tenant Name. Tenant names are stored locally on the PC and are not
uploaded. Note that the same keyless entry code or card number can be programmed multiple times, as shown in the
example below with the “2222” keyless entry code.
12
Page 13
4. Phone Name
Up to a 31 character phone name can be assigned to the K-1900-8-IP being programmed. Often times the building
name and entrance location near the unit are used for the name.
5. Mute Current / Next Alarm
A network failure alarm will be indicated by providing 3 beeps every 30 seconds in the handset of the K-1900-8-IP. A
network failure indicates the unit is not registered to the SIP server or there is a communication failure with the gateway.
The three beeps can be muted by clicking on “Mute Current / Next Alarm”.
6. Phone Firmware
If new K-1900-8-IP firmware is available, after opening the programming software a pop up window will ask if you would
like to update firmware. Another way to update is accomplished by clicking the phone firmware “Update” button. You
can then browse to the folder that contains the HEX file for updating the unit’s firmware. This method is typically only
used when Viking Technical Support has sent you updated firmware.
Note: Export your phone settings before updating firmware.
7. IP Firmware
If new K-1900-8-IP firmware is available, after opening the programming software a pop up window will ask if you would
like to update firmware. Another way to update is accomplished by clicking the IP firmware “Update” button. You can
then browse to the folder that contains the PIP file for updating the unit’s IP firmware. This method is typically only used
when Viking Technical Support has sent you updated IP firmware.
8. Import/Export
The Import/Export feature is useful for backing up all the K-1900-8-IP’s programming or for importing programming
when installing multiple units with a majority of the same programming.
9. Default Phone Settings
Clicking on the “Default Phone Settings ” button in programming will reset all of the Programming Features back to their
factory default settings. Note: This command will not change or reset your IP settings.
9.5. Default IP Settings
Clicking on the “Default IP Settings ” button in programming will reset all IP Features back to their factory default settings.
10. Diagnostics
The Diagnostics section in the Viking IP Programming can be used to test the functionality of the two relays, read current
relay status or to display information on the last card or fob detected by the card reader.
11. Security Code
The security code allows the user/installer to program the K-1900-8-IP phone with a PC and the required ‘Viking IP
Programming” software. The factory set security code is 845464. If the security code of the phone is left as default, the
PC software will not require entering a security code to connect to the phone. It is recommended that the factory set
security code be changed.
Note: The security code must be 6 digits and cannot include a
Q
or a #.
12. Access Code
The access code comes into play when a tenant calls the K-1900-8-IP and a visitor lifts the handset to answer the call
or the K-1900-8-IP automatically answers the call (see Inbound Call Mode). It is a 1 to 6 digit code (can not contain “
or “#”) that the tenant must dial before they are allowed to operate the door strike relays, as extra security on inbound
calls. Once a tenant has entered the correct access code, 2 beeps are heard and the user can now enter any “Remote
Access Operation Commands” (see page 18). The access code can be disabled if this basic security is not required.
13
Q
”
Page 14
13. Inbound Call Mode
The Inbound Call Mode determines how the K-1900-8-IP handles incoming calls. One option is to generate a ring
sound through the handset receiver, allowing someone to lift the handset to answer the inbound call. The K-1900-8-IP
can also auto answer the call, to allow remote control of the doorstrike relays and the ability to listen to transmit audio
from the handset of the phone. The last option is the silent monitor mode, which allows callers to listen to the transmit
audio from the handset of the phone at a much higher volume than normal. The “secure” options for auto answer and
silent monitor require the callers to dial the access code in order to remain connected and listen to the audio from the
handset.
Disabled – Inbound calls are not allowed.
Auto Answer – Inbound calls are auto answered and the caller hears transmit audio from the handset at a normal
volume level.
Auto Answer Secure – Inbound calls are auto answered and the caller must dial the access code in order to listen to
transmit audio from the handset (volume level is still normal).
Ring Low – In the “low” mode the phone will output a ring signal out of the earpiece in the ring pattern selected in Ring
Cadence. The call can then be answered by taking the handset off hook.
Ring High – In the “High” mode the phone will output a slightly louder, higher pitched ring signal out of the earpiece in
the ring pattern selected in Ring Cadence. The call can then be answered by taking the handset off hook.
Silent Monitor – Inbound calls are auto answered and the caller hears transmit audio from the handset at a much
higher volume level.
Silent Monitor Secure – Inbound calls are auto answered and the caller must dial the access code in order to listen to
transmit audio from the handset (volume level is still at a much higher volume level).
14. Ring Cadence
When “Inbound Call Mode” on the K-1900-8-IP is set to “Ring Low” or “Ring High” the Ring cadence can be programmed
to one of 4 different cadences:
Normal Ring (single ring, 2 sec on 4 sec off)
Double Ring (double ring, 1 sec on .5 sec off 1 sec on 3.5 sec off)
Short-Short-Long (triple ring, .5 sec on .5 sec off .5 sec on .5 sec off 1 sec on 3 sec off)
Short-Long-Short (triple ring, .5 sec on .5 sec off 1 sec on .5 sec off .5 sec on 3 sec off)
15. Phone Mode
The Phone Mode can be programmed to one of two settings: Auto Dialer or Manual Dial Phone. When set to Auto Dialer
the K-1900-8-IP will auto dial any preprogrammed phone numbers stored in the Phone Number Database when the
corresponding Speed Dial Number (example: apartment number) is entered on the unit’s keypad. When set to Manual
Dial Phone the unit’s auto dialing features are disabled and the unit functions as a standard VoIP phone. When the
handset of the K-1900-8-IP is lifted, dial tone is provided and the user can manually dial the desired number on the
keypad.
16. Off Hook AutoDial
When the Off Hook AutoDial feature is enabled, it allows visitors that do not know the tenant’s apartment number (Speed
Dial Number) a way of simply going off-hook with the handset (with no additional numbers entered) and the unit will
automatically dial the Primary Phone Number stored in Phone Number Database Index 0. This could route the call to
the building manager, care taker, receptionist, etc. The Phone Mode must be set to “Auto Dialer” in order to use this
feature. When the Off Hook AutoDial feature is disabled, a user hears three beeps instead of being routed to Phone
Number Database Index 0, once the Off Hook Dialing Delay has expired.
14
Page 15
17. Off Hook Dialing Delay
The Off Hook Dialing Delay is the length of time a user hears simulated dial tone after picking up the handset before
they are routed to the Primary phone number in the Phone Number Database Index 0 or hear 3 beeps, depending on
the Off Hook AutoDial program option.The time is programmable from 0 to 6 seconds. Off Hook Dialing Delay time is
needed to allow visitors time after they come off-hook to then enter the tenant’s apartment number (Speed Dial Number)
or their Keyless Entry Code. This is factory set to 3 seconds.
18. Select Time Zone
When using date and time logged events or setting the access date and times of keyless codes or proximity cards in
the Entry Code Database, you must program the unit to your time zone. Example: You are installing the K-1900-8-IP in
the Central standard time zone: Select (UTC - 06:00) CST, which is 6 hours behind Coordinated Universal Time (UTC).
19. Daylight Savings
The Daylight Savings Time programming can be enabled or disabled and can be programmed to start on any Sunday
in March and stopped on any Sunday in November. Currently, daylight saving time starts on the second Sunday in
March and ends on the first Sunday in November, with the time changes taking place at 2:00AM local time.
20. Keyless/Card Logging
Keyless Entry Code and Proximity Card logging can be set to Log Errors. With Log Errors selected, the K-1900-8-IP
will not only log all valid Keyless Entry Code and Proximity Card entries, but also log any errors, incorrect codes, or
non-valid card reads.
Keyless Entry Code and Proximity Card logging can also be set to Live Logging. With Live logging selected and the
K-1900-8-IP programming software open and connected to a unit, each Keyless Entry Code entered or Proximity Card
read will immediately open the Event Log screen and display the latest entry.
21. Relay Mode
Doorstrike Mode: When programmed for Doorstrike Mode the relay is intended for door strike, maglock or gate control.
The relay can also be touch tone activated by dialing a “#” plus a valid keyless entry code or by scanning a valid
proximity card that has been assigned to that relay.
Outbound Call Mode: When programmed for Outbound Call Mode the relay will activate continuously for the duration
of any outbound call from the Entry phone.
Inbound/Outbound Call Mode: When programmed for Inbound/Outbound Call Mode the relay will activate
continuously for the duration of any inbound or outbound call to or from the Entry phone. This mode is useful for turning
on IR flood lights, for VoIP phones with cameras, etc.
Doorbell Mode: When programmed for Doorbell Mode the relay will momentarily activate the relay for the
preprogrammed relay activation time on any outbound call from the Entry phone. This mode is useful for activating a
door chime, etc. When activating door chimes, a 0.5 - 1 second relay activation time is recommended.
Alarm Mode: When programmed in Alarm Mode the relay will activate continuously while the Entry phone is powered
and registered to the SIP server. In the event the unit loses power and/or SIP registration the relay will turn off, which
can be used to signal an alarm device. This can only be used for internal relay control.
Ring Mode: When programmed for Ring Mode the relay will continuously activate while the ringing extension is called.
This mode is useful for activating a Viking model SL-2 strobe light, etc.
Ring Flash Mode: When programmed for Ring Flash Mode the relay will momentarily turn on and off in a 400ms on/off
cadence while the ringing extension is called. This mode is useful for activating a Viking LPL-1 Remote Visual Indicator,
etc.
15
Page 16
22. Relay 1 or 2 (Activation) Command
The one or two digit code stored in the Relay Activation Command is the touch tone command that the person being
called must enter on their phone in order to momentarily activate relay 1 or 2 to control a doorstrike, mag-lock, gate
controller, or other device. The code can contain the characters 0 - 9, # or Q. The code cannot match a relay latching
or toggle command (11, 10, 1#, 21, 20, or 2#). The code must be entered while the remote phone is communicating
with the Entry phone. The Entry phone determines which direction the touch tone is coming from and only responds to
touch tones from the called phone. The factory setting is QQ for relay 1 and Q2 for relay 2.
23. Relay 1 or 2 Activation Time
The value stored in the Relay 1 or 2 Activation Time is the amount of time relay 1 or 2 will be energized after a correct
momentary touch tone command is entered, “#” plus a valid keyless entry code or a proximity card was scanned that
is programmed to momentarily activate the relay. This number can range from 0.5 to 99 seconds. The factory setting
is 5 seconds.
24. Relay 1 or 2 Internal / External
With relay 1 and/or 2 set to “Internal” the K-1900-8-IP will activate its on board relays for door strike / gate control.
Relay 1 and/or 2 should be set to “External” for higher security installations when using a Viking remote model RC-4A
relay controller to activate the door strike / gate controller (see page 6).
25. Relay Activation Delay
A relay activation delay of 0.5 to 99 seconds can be programmed in the K-1900-8-IP. A relay activation delay is useful
in two door vestibule entrance applications. This allows you to program a delay time from when relay 1 (outside door)
is activated to when relay 2 (inside door) is activated. The programmed delay time should be set to the average time
it takes a person to walk from the outside door to the inside door.
When a request for exit (REX) is activated, relay 2 will activate first, then after the programmed delay relay 1 will
activate.
26. Relay Latch Commands
When programmed to “Enable” (factory default) the Remote Access Operation Commands to Un-Latch, Latch or Toggle
the relay are enabled.
When programmed to “Disable” the Remote Access Operation Commands to Un-Latch, Latch or Toggle the relay are
disabled. Disabling the Latch commands can be useful in applications where you want to eliminate the possibility of
inadvertently entering a latch command leaving a gate open/closed, etc.
27. In-Band Audio Call Progress
The In-Band Audio Call Progress Detection can be set to enabled or disabled. In-Band Audio Call Progress detection
should be enabled in applications where you are making an outbound call through your VoIP phone system and are
relying on In-Band analog audio for ringback or busy detection. The factory default is: enabled.
28. In-Band Audio Detect Sensitivity
The In-Band Audio Detect Sensitivity can be set from 1 to 9 (1 = minimum setting, 9 = the highest sensitivity, factory
set to 5). Increasing or decreasing the sensitivity may be required in applications where you are making an outbound
call through your VoIP phone system and are relying on In-Band analog audio detection. Power cycle unit after changing
this setting.
29. Call Length Time Out
This feature selects the maximum length of time that calls can be connected. Programmable in increments of 1 minute
up to a maximum of 9 minutes or disabled. With the call length disabled, the K-1900-8-IP phone must rely on a call
ended signal, busy signal, or touch tone “#” command to hang-up.
Note: The factory default is 3 minutes.
16
Page 17
30. Dial Next Number on Ring No Answer
If enabled and a ring-no-answer is detected, the K-1900-8-IP phone will dial the “Roll Over” speed dial number. This
can be set from 1 - 9 rings.
Note: Factory set to redial if not answered after 7 rings.
31. Dial Next Number on Busy
If enabled and a busy is detected, the K-1900-8-IP phone will dial the “Roll Over” speed dial number.
Notes: This feature is enabled in the factory default setting. If the busy signal is interrupted with a promotional message,
contact your central office to have it removed.
32. Live Dialing Format
The Live Dialing Format can be set to In-Band DTMF (Touch Tones) or RFC 2833 (Out of Band DTMF Touch Tones). Live
dialing refers to the numbers dialed after an outbound call has been answered by the distant party. This would typically be
the numbers dialed to steer through automated attendants, voice mail, etc. If your VoIP phone system does not
automatically convert out of band DTMF to In-Band after the call is answered, set Live Dialing Format to “Inband DTMF”.
33. REX Input
The K-1900-8-IP has one Request for Exit (REX) trigger input. The REX switch must have a momentary, normally
open contact. When the K-1900-8-IP detects a contact closure on the REX trigger input it performs one of the following
actions, based on the Relay Mode settings for each relay (see section 22):
NOTE: For security reasons the REX input is only enabled when the relay is set to “Internal”.
Relay 1 "Door Strike", relay 2 other: Relay 1 will be activated for the programmed Relay 1 Activation Time.
Relay 1 other, relay 2 "Door Strike": Relay 2 will be activated for the programmed Relay 2 Activation Time.
Relay 1 "Door Strike", relay 2 "Door Strike": If the Relay Activation Delay is disabled, Relay 2 will be activated for
the programmed Relay 2 Activation Time. If Relay Activation Delay is not disabled, Relay 2 will be activated for the
programmed Relay 2 Activation Time, then after the Relay Activation Delay time has passed, Relay 1 will be activated
for the programmed Relay 1 Activation Time. This is useful in two door vestibule applications where Relay 1 is used to
unlock the outside door, and Relay 2 is used to unlock the inside door.
34. Wiegand Direction
Wiegand Direction allows you to decide if the 26 bit Wiegand connection will be used as an input or an output. The default
setting for direction is “Inbound” and this is the correct setting if you intend to connect a card reader or Wiegand keypad
device to the wiegand connections.
When the direction is set to “outbound”, the 26 bit Wiegand connections become an output and can be connected to the
card reader input on the access control system. Unprogrammed keyless entry codes dialed by the user on the keypad are
then sent over the Wiegand output. When the user dials “#” plus a entry code that is not programmed in the Entry Code
Database, the code dialed by the user is sent over the Weigand output along with the facility code selected. Since Wiegand
data limits the entry code to 65535 maximum, “#” plus entry codes higher than 65535 are not sent over the Wiegand
output. When the user dials “#” plus a valid keyless entry code that is programmed in the Entry Code Database, the code
dialed by the user is not sent over the Wiegand output and the Local / External relay is activated.
17
Page 18
Operation
A. Making a Call
The K-1900-8-IP can be programmed to function as a single number auto dialer, a multi-number dialer or a manual
dial phone. The operation for the user depends on which mode it is running.
Single Number Auto Dialer (Phone Mode set to “AutoDialer and the Off Hook AutoDial set to “enabled”)
With the Off Hook Dialing Delay set to “No Delay”, when the handset is taken off-hook, the K-1900-8-IP will immediately dial the
primary phone number programmed in the Phone Number Database Index 0. If there is no number programmed in the Phone Number
Database Index 0 position, the user will get a simulated busy signal when the handset is lifted. “#” plus a keyless entry code can be
dialed while the handset is hung up. Proximity cards can be scanned at any time, even while a call is in progress. The Off Hook
Dialing Delay can be set to a delay of 1 - 6 seconds in this mode, if you wish to allow users to pick up the handset and dial “#” plus
a valid keyless entry code, before being sent to the phone number in the Phone Number Database Index 0.
Multi-Number Auto Dialer (Phone Mode set to “AutoDialer and a delay time selected for Off Hook Dialing Delay)
With the Off Hook Dialing Delay set from 1 - 6 seconds, when the handset is taken off-hook, the user will hear 1 - 6 seconds of dial
tone, allowing them time to enter the 1-3 digit Speed Dial number (0-999). The unit will then dial the Primary Phone Number
associated with the selected 1-3 digit Speed Dial Number (0-999). In the event the line is busy or ring-no-answer, the unit can be
programmed to call a second roll over number. If Off Hook AutoDial is enabled, users that don’t dial digits on the keypad during the
provided dial tone will be automatically sent to the phone number programmed into Phone Number Database Index 0. If Off Hook
AutoDial is disabled, users that don’t dial digits on the keypad will hear 3 beeps after the provided dial tone. “#” plus a keyless entry
code can be entered while the handset is hung up, or as the first digits dialed after lifting the handset. Proximity cards can be scanned
at any time, even while a call is in progress. A user that dials “*” on the keypad will automatically be sent to the phone number
programmed into Phone Number Database Index 0.
Manual Dial Phone (Phone Mode set to ”Manual Dial Phone')
When the handset is lifted in the Manual Dial Phone mode, the user hears dial tone. Any keypad entries dialed by the user are
gathered and sent to the SIP phone system, just like a standard VoIP phone. In this mode, “#” plus a keyless entry code can only
be entered while the handset is hung up. “#” or any keypad characters dialed after the handset is lifted are sent to the phone system
as dialed digits. Proximity cards can be scanned at any time, even while a call is in progress.
In any of the above modes, relay activation commands can be entered or “#” can be dialed (from the remote phone only) to force
the phone to hang-up.
After communication is established, enter the 1 or 2 digit relay activation command (factory set to “QQ” for Relay 1 and ”Q2” for
Relay 2) to momentarily activate the entry phone (door strike) relay. Two beeps will be heard confirming that the relay has been
activated. If you require the relay to remain on continuously (ie: a truck delivery), enter Touch Tones “11” or “21” to continuously
activate relay 1 or relay 2 respectively. A double beep will indicate that the relay is latched on. When the visitor calls in again (ie:
they are finished unloading the truck), enter Touch Tones “10” or “20” to deactivate relay 1 or relay 2 respectively. A single beep will
indicate the relay is latched off.
*Note: Relay latch Commands can be disabled in programming.
B. Inbound Calls
How inbound calls are handled is determined by the Inbound Call Mode and these are the available options (see Inbound Call Mode
on page 13 for more details):
Disabled - Inbound calls are blocked. Users will get busy or reorder tone if they attempt to call.
Ring Low or Ring High – Inbound calls generate a ring through the receiver of the handset using either a low or high pitched ring
sound. Someone must lift the handset to answer the call.
Auto Answer or Auto Answer Secure – The K-1900-8-IP auto answers the inbound call and the caller can listen to transmit audio
from the handset at a normal volume level or remotely control the door strike relays if desired. In the “Secure” mode, the caller must
dial the access code in order to listen to handset audio or control relays.
Silent Monitor or Silent Monitor Secure – The K-1900-8-IP auto answers the inbound call and the caller can listen to transmit
audio from the handset at a much louder volume than normal or remotely control the door strike relays if desired. The louder volume
allows the caller to listen to sounds or conversations occurring around the phone. In the “Secure” mode, the caller must dial the
access code in order to listen to handset audio or control relays.
18
Page 19
C. Remote Access Operation Commands
The following commands can be entered after answering a call from the entry phone. The commands can also be entered on an
inbound call to the entry phone. After calling into the entry phone and the unit auto answers or someone answers the call by lifting
the handset, one or two beeps will be heard. If the access code has been disabled (two beeps heard), you can now enter the Remote
Access Operation Commands below. If an Access code has been programmed (one beep heard), enter the Access code digits. With
the correct code entered, two beeps will be heard and you can now enter the Remote Access Operation Commands below. The
Relay Mode must be set to “Door Strike” to be controlled by these commands.
Feature
Momentarily
Activate Relay 1
Latch Relay 1
Un-Latch Relay 1
Toggle Relay 1
Momentarily
Activate Relay 2
Latch Relay 2
Un-Latch Relay 2
Toggle Relay 2
Disconnect
Touch Tone
Command
QQ or
___ ___
Description
Momentarily activate relay 1 (1 or 2 digits, factory set to QQ).
11Latch* (continuously activate) relay 1.
10Un-latch* (deactivate) relay 1.
1#Toggle* relay 1 from last position.
Q2 or
___ ___
Momentarily activate relay 2 (1 or 2 digits, factory set to Q2).
21Latch* (continuously activate) relay 2.
20Un-latch* (deactivate) relay 2.
2#Toggle* relay 2 from last position.
#Disconnects or forces the phone to hang up.
* Note: Latching commands must be enabled in programming.
D. Keyless Entry Codes and One Time Use Keyless Entry Codes
Keyless entry codes may be used by the tenants to provide keyless entry. The K-1900-8-IP can be programmed with a combination of
up to 1000* keyless entry codes or one time use keyless entry codes. The keyless entry codes can be programmed to be from 1 to 6
digits in length. Each keyless entry code can be programmed to activate relay 1 and/or 2 in four different relay modes: Momentary,
Latch, Un-Latch and Toggle. To use a keyless entry code the tenant simply dials “#” followed by the entry code on the K-1900-8-IP’s
keypad. After the one time use keyless entry code has been used, it is instantly cleared from the unit’s memory. This is ideal for issuing
keyless entry codes to service personnel, etc.
Keyless entry codes can only be dialed while the handset is hung up in the Manual Dial Phone mode. In the Single and Multi-Number
Auto Dialer modes, keyless entry codes can be dialed while the handset is hung up or when the handset is first lifted, when some delay
has been programmed for Off Hook Dialing Delay.
E. Proximity Cards
Proximity cards can also be used by the tenants to provide keyless entry. The K-1900-8-IP can be programmed with up to 1000* proximity
card numbers. Each proximity card number can be programmed to activate relay 1 and/or 2 in four different relay modes: Momentary,
Latch, Un-Latch and Toggle. To use a proximity card, the tenant simply presents a preprogrammed proximity card within range
proximity card reader attached to the K-1900-8-IP. A short beep will be heard from the card reader indicating a card scan. If the card
matches a valid preprogrammed card number the relay will be activated and the visitor can now open the door or gate.
Proximity cards can be scanned at anytime, even while a call is in progress.
*Note: 1000 is the total number of Keyless Entry Codes and/or Proximity Card numbers that can be programmed in the Entry Code
Database.
**Note: Read range depends on the type of card and card reader being used.
F. 911 Calls
The K-1900-8-IP is not intended to be an emergency phone and does not try to automatically handle users that dial “911” after picking up
the handset. In the Manual Dial Phone mode, the “911” dialed by the user is passed on to the phone system, so it is up to the SIP phone
system or provider to route the call properly. In the Single and Multi-Number Auto Dialer modes, a speed dial of “911” can be programmed
with primary and rollover phone numbers, to route the calls appropriately. Some delay must be programmed for Off Hook Dialing Delay,
to give the user time to dial the “911” before they are automatically routed to another number or hear 3 beeps.
19
**
of the
Page 20
Troubleshooting
If the unit cannot register with the programmed SIP server, three error beeps will be heard in the handset every 30 seconds until
communication is restored. This alerts a potential user of a problem with the device that will prevent a phone call from being made.
You may silence the error beeps, per instance, by clicking the “Mute Current / Next Alarm” button in the Viking IP Programming Software
(see section B on page 8). The error beeps automatically re-enable once the unit is registered, to alert of any new problems that arise.
Related Products
Surface or Pedestal Mount Viking Products
While Maintaining Weather and Vandal Resistance
The VE-3x5, VE-5x5, VE-6x7 and VE-5x10 add vandal and
weather resistance, as well as versatility to many Viking products.
The VE-Series backboxes are available in black fine texture
powder painted steel or marine grade 316 stainless steel. The
weather resistant boxes are designed to be surface mounted to
a wall, post, single gang box, or a VE-GNP gooseneck pedestal.
Note: The VE-3x5 is not compatible with the VE-GNP pedestals
and is not available in stainless steel.
VE-3x5*
VE-5x5VE-5x5-SSVE-5x5-RDVE-5x5-PNL VE-5x5-PNL-SS
VE-GNP-2
VE-GNP-IG
VE-GNP-SS
VE-GNP
VE-GNP-SS
The VE-GNP gooseneck pedestals
are designed to be used with the
VE-5x5, VE-6x7 and VE-5x10
backboxes and are ideal for drive
up communications. Note: The
VE-3x5 is not compatible with the
VE-GNP pedestals.
VE-GNP
The VE-PNL’s are VE-Series backboxes with a blank aluminum panel. The user can
customize the clear-coated aluminum panel to mount an PRX-1 card reader, PRX-2 keypad or switch. The kits come complete with box, gasket, panel and screws.
Model numbers that end with “SS” are stainless steel version. Note: The use of
magnets to mount the VE-Series enclosure to a metal surface can affect the
operation of the enclosed product.
Caution: Handsfree phones are not suitable for noisy applications (see “Important”
on page 2).
For more information on Viking Surface Mount Boxes and Pedestals, see DOD 424.
VE-6x7VE-6x7-SSVE-6x7-PNL
VE-5x10-NR VE-5x10-NR-SS
VE-5x10VE-5x10-SS VE-5x10-PNL
VE-6x7-PNL-SS
VE-5x10-PNL-SS
Add Panel Lighting to Your Viking VoIP Entry Phone
The VE-LIGHT kit adds bright LED illumination to any VoIP entry phone that is
housed in a Viking VE-5x5, VE-6x7 or VE-5x10 enclosure.
The stainless steel bracket is easily mounted using existing holes and hardware.
Two bright white LEDs are used as the light source, so there are no filaments to
break or bulbs to burn out.
12 VDC power adapter included. Any power source between 12 and 24 volts, AC or
DC can be used to supply the VE-LIGHT with power. The K-1900-8-IP provides 12
VDC power for this. See features overview (Page 4).
For more information, See DOD 428.
VE-LIGHT shown right with Viking
E-30 and VE-5x5 (not included)
20
Page 21
Related Products
Control Relay Contacts Across a Local Area Network
The RC-4A Network Enabled Relay Controller provides networked control of four relays via an easyto-use web interface. The same interface can be used to check the status of four contact closure
inputs. Relays can be toggled on or off, or user-programmed timed closures can be activated.
The RC-4A can be configured to work as a remote relay for Viking VoIP series entry phones,
controlling door strikes and gates when a remote relay is required for security reasons. It can also be
programmed to send an email or text message in response to a change in one or more of the sensor
inputs. Two RC-4A’s can be set up so that activity on a sensor input of one unit will automatically
send a message across the network to activate one of the relays on the other unit. Two levels of user
access permit selected users to have full operational and programming rights while others have
operational control but not programming capability.
For more info, see DOD 582
125KHz Proximity Card Reader
The model PRX-1 is a 125KHz proximity
card reader and is designed to be mounted
directly to a metal door or window frame
(mullions), making it ideal for applications
requiring an access credential. The
proximity card reader transmits data in 26Bit Wiegand format, making it compatible
with any of the Wiegand equipped Viking
entry controllers.
The PRX-1 delivers non-contact read
PRX-1
a compact 3.2 x 1.7 x 0.70 inches (80 x 43 x 17 mm). Mounting is
simplified with horizontal and vertical mounting slots, which allow
the reader to be conveniently adjusted and leveled. To allow both
indoor and outdoor operation the electronics are sealed in tamper
resistant epoxy potting. Concealing the mounting hardware, the
PRX-1 ships with both Black and Ash (Off-White) covers standard.
See DOD 221 for more information.
125KHz Proximity Cards
The PRX-C and PRX-C-ISO are non-contact security cards that
can be presented to the front of a K-1770/75-IP proximity card
reader to allow entrance into a secured area. The PRX-C is a
clam shell card made made from 0.070” thick plastic to resist
bending and folding. A slot is provided at one end to allow a
ranges up to 6 inches (152 mm), and
operates from 5 to 14 VDC. Physical size is
lanyard to be added for creating
a “dog tag” style neck strap.
The PRX-C-ISO is a thin 0.032”
thick flexible “ISO” style
proximity card. Much like a
credit card, the PRX-C-ISO is
perfect for storing in your wallet.
The PRX-FOB is a proximity
key ring fob with brass eyelet
designed to attach to a key
chain or necklace. The PRX-FOB’s compact size is only 1.5”
x 1.2” x 0.15” making it one of
the smallest available.
The cards and fobs are custom
pre-programmed. For more
information see DOD 198.
Medium Range 125KHz Proximity
Card Reader
The model PRX-3 is a high
performance medium range
125KHz proximity card reader.
The PRX-3’s compact size yet
long read range of up to 16
inches* make it ideal for parking
PRX-3
directly to a wall, post, single gang electrical box or use an optional
mounting kit for attaching it to a gooseneck pedestal. Mounting is
simplified with horizontal and vertical mounting slots, which allow
the reader to be conveniently adjusted and leveled. To increase
vandal resistance the chassis is a single piece design with the
mounting screws concealed behind a UV stable label.
The proximity card reader transmits data in 26-Bit Wiegand format,
making it compatible with any of the Wiegand equipped Viking entry
controllers. The PRX-3 is equipped with Enhanced Weather
Protection (EWP) for outdoor installations where the unit is
exposed to precipitation or condensation. With its sealed
connections and fully potted electronics the PRX-3 is designed to
meet an IP66 Ingress Protection Rating. For more information
see DOD# 228.
control, gate access, turnstiles,
etc. It is designed to be mounted
Long Range 4 Channel Transmitters and
Receivers
Viking’s model LTR-4 Long Range Wireless 4
Channel Radio Transmitters and LRR-4 Long
Range 4 Channel Receivers with integrated
receive antenna comprise Vikings high
frequency, long-range (RFID) identification
solution. Intended for security access control
applications, the LRT-4’s wireless communication
is based upon a secure, digital, anti-playback
routine. The LRT-4 Transmitters have four
LRT-4LRR-4
output on the LRR-4 Receiver. Each Transmitter includes an integrated red
LED, used to indicate both positive button press and battery strength. They
are also equipped standard with a 125KHz HID** compatible potted
proximity module allowing the Transmitter to also be used as a close range
access credential.
The transmitters and receivers operate at 433-MHz allowing a transmission
range of up to 400 ft (line of sight). The LRR-4 receiver has an adjustable
read range, optional external antenna connector, terminal block with 4
channel Wiegand data output and a transducer and LED to confirm
transmitter button press. The LRR-4 has a conformal coated circuit board
mounted in a NEMA 4, 4x rated box for use in outdoor applications. See
DOD 226 for more information.
21
buttons, each corresponding to its own Wiegand
Page 22
Warranty
IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, CONTACT: VIKING TECHNICAL SUPPORT AT (715) 386-8666
Our Technical Support Department is available for assistance Monday through Friday 8:00am to 5:00pm central time. So that we can give you better
service, before you call please:
1. Know the model number, the serial number and what software version you have (see serial label).
2. Have your Product Manual in front of you.
3. It is best if you are on site.
RETURNING PRODUCT FOR REPAIR
The following procedure is for equipment that needs repair:
1. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number. The customer MUST
have a complete description of the problem, with all pertinent information regarding the defect, such as options set, conditions, symptoms, methods to
duplicate problem, frequency of failure, etc.
2. Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. Static sensitive equipment such as a
circuit board should be in an anti-static bag, sandwiched between foam and individually boxed. All equipment should be wrapped to avoid packing
material lodging in or sticking to the equipment. Include ALL parts of the equipment. C.O.D. or freight collect shipments cannot be accepted. Ship
cartons prepaid to: Viking Electronics, 1531 Industrial Street, Hudson, WI 54016
3. Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a PO Box.
4. RA number on carton: In large printing, write the R.A. number on the outside of each carton being returned.
RETURNING PRODUCT FOR EXCHANGE
The following procedure is for equipment that has failed out-of-box (within 10 days of purchase
1. Customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer MUST be able to
step through recommended tests for diagnosis.
2. If the Technical Support Product Specialist determines that the equipment is defective based on the customer's input and troubleshooting, a Return
Authorization (R.A.) number will be issued. This number is valid for fourteen (14) calendar days from the date of issue.
3. After obtaining the R.A. number, return the approved equipment to your distributor, referencing the R.A. number. Your distributor will then replace the
Viking product using the same R.A. number.
4. The distributor will NOT exchange this product without first obtaining the R.A. number from you. If you haven't followed the steps listed in
1, 2 and 3, be aware that you will have to pay a restocking charge.
):
Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of two years from the date of purchase
TWO YEAR LIMITED WARRANTY
from any authorized Viking distributor. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics,
Inc., 1531 Industrial Street, Hudson, WI., 54016. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.)
number.
This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence or any damage caused by
use of the product by the purchaser or others. This warranty does not cover non-EWP products that have been exposed to wet or corrosive environments. This warranty
does not cover stainless steel surfaces that have not been properly maintained.
NO OTHER WARRANTIES. VIKING MAKES NO WARRANTIES RELATING TO ITS PRODUCTS OTHER THAN AS DESCRIBED ABOVE AND DISCLAIMS ANY
EXPRESS OR IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
EXCLUSION OF CONSEQUENTIAL DAMAGES. VIKING SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO PURCHASER, OR ANY OTHER PARTY,
FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR EXEMPLARY DAMAGES ARISING OUT OF OR RELATED TO THE SALE OR USE OF THE PRODUCT SOLD
HEREUNDER.
EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY. WHETHER IN AN ACTION BASED ON CONTRACT, TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY)
OR ANY OTHER LEGAL THEORY, ANY LIABILITY OF VIKING SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT, OR AT VIKING'S OPTION,
REFUND OF THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND ANY LIABILITY OF VIKING SHALL BE SO LIMITED.
IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER OF
WARRANTIES, EXCLUSION OF CONSEQUENTIAL DAMAGES, AND EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY, ARE SEVERABLE FROM ANY OTHER
PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH.
If trouble is experienced with the K-1900-8-IP phone, for repair or warranty information, please contact:
WHEN PROGRAMMING EMERGENCY NUMBERS AND (OR) MAKING TEST CALLS TO EMERGENCY NUMBERS:
Remain on the line and briefly explain to the dispatcher the reason for the call. Perform such tests in off-peak hours, such as early morning or late evenings.
PART 15 LIMITATIONS
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
CANADA
This class A digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la classe A est conforme a la norme NMB-003 du Canada.
Product Support: 715-386-8666
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries
assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.
DOD 361
Printed in the U.S.A.
22
ZF303790 REV B
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.