VICOR VI-RUZNX-XXXX, VI-RUZMX-XXXX, VI-RUZLX-XXXX, VI-RUZKX-XXXX, VI-RUZJX-XXXX Datasheet

...
0 (0)
VICOR VI-RUZNX-XXXX, VI-RUZMX-XXXX, VI-RUZLX-XXXX, VI-RUZKX-XXXX, VI-RUZJX-XXXX Datasheet

FlatPAC

Product Highlights

If you’re looking for the convenience of a complete, low profile, agencyapproved switching power supply, look no further. The FlatPAC combines Vicor’s workhorse VI-200 family of DC-DC converters with a modular package and front end subassembly to provide from 50 to 600W of output power from one to three outputs.

A flat plate heatsink for use in conduction cooled applications may be specified as an alternate to the standard finned version by adding “CC” to the end of the model number.

Vicor’s FlatPAC is also available with a current controlled output using BatMod converter modules of 12, 24, or 48Vdc outputs. This option is specified by appending “BM” or “BC” (for conduction cooled versions) to the end of the FlatPAC model number.

The FlatPAC’s contemporary design allows us to configure your order quickly and provide rapid turnaround on standard models. It is truly a complete power solution, enabling

you to spend more time designing your system and less time worrying about how to power it.

50 to 600W Autoranging AC-DC Switchers

Features

Microcontroller architecture

Inputs: 115/230Vac autoranging

Meets FCC Part 15, EN55022, Class B conducted emissions

80-90% efficiency

Any output: 1 to 95Vdc

Module enable/disable (except LU series)

UL, CSA, TÜV, VDE, BABT, CE marked

Remote sense and current limit

BUS OK and AC OK (except LU series)

40mS ride-through time

OVP and thermal shutdown

1 output; up to 200W

1 or 2 outputs; up to 400W

1, 2, or 3 outputs; up to 600W

FlatPAC Configuration Chart

Typical Model: V I - R U

0

 

1

 

1

E

 

U

 

U

 

U

 

 

 

 

 

Input: 115/230Vac; Output 1: 5Vdc at 200W

 

 

 

 

 

 

 

 

 

 

 

 

 

Output 2: 12Vdc at 200W

 

 

 

 

 

 

 

 

 

 

 

 

 

Output 3: 12Vdc at 200W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

# of

 

 

Total Power

Part No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Converters

Dimensions

Single

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outputs:

50-200W

VI-LU

 

 

 

 

 

 

 

 

 

 

1

9.25" x 2.5" x 1.37"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(234,8 x 63,5 x 34,8mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200-400W

VI-MU

 

 

 

 

 

 

 

 

 

 

2

9.25" x 4.9" x 1.37"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(234,8 x 124,5 x 34,8mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300-600W

VI-NU

 

 

 

 

 

 

 

 

 

 

3

9.25" x 7.3" x 1.37"

Dual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(234,8 x 185,4 x 34,8mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outputs:

100-400W

VI-PU

 

 

 

 

 

 

 

 

 

 

 

2

9.25" x 4.9" x 1.37"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(234,8 x 124,5 x 34,8mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150-600W

VI-QU

 

 

 

 

 

 

 

 

 

 

 

3

9.25" x 7.3" x 1.37"

Triple

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(234,8 x 185,4 x 34,8mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outputs:

150-600W

VI-RU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

9.25" x 7.3" x 1.37"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(234,8 x 185,4 x 34,8mm)

Input Characteristics

90-132/180-264Vac

U = Autoranging

Vout

Output Power

 

5V

Vout < 5V

W = 100W

W

= 20A

V

=

150W

V

=

30A

U

=

200W

U

=

40A

S

=

300W

S

=

60A

Q

=

400W

Q

=

80A

 

 

 

 

 

 

Output Voltage

Z 2V

M 10V

K 40V

Y 3.3V

1 12V

4 48V

0 5V

P 13.8V

H 52V

X 5.2V

2 15V

F 72V

W 5.5V

N 18.5V

D 85V

V 5.8V

3 24V

B 95V

T 6.5V

L 28V

 

R 7.5V

J 36V

 

Product Grade

E = 0°C to +85°C Case C = 0°C to +85°C Case

I = -30°C to +85°C Case

Output Power/Current

Vout

5V

Vout < 5V

S

=

300W

S

=

60A

P

=

450W

P

=

90A

M = 600W

M

= 120A

Output Power/Current

Vout

5V

Vout < 5V

Y

=

50W

Y = 10A

X

=

75W

X = 15A

W =

100W

W = 20A

V

=

150W

V = 30A

U

=

200W

U = 40A

Options

BC = BatMod/Conduction

Cooled

BM= BatMod

CC = Conduction Cooled

FlatPAC 10/02 1 of 4

FlatPAC Specifications

(Typical at 25°C, nominal line and 75% load, unless otherwise specified.)

Input Characteristics

 

AC line input

 

Autoranging

90-132/180-264Vac

Line frequency

47 to 63Hz (C-grade and E-grade)

 

47 to 440Hz (I-grade)

Inrush current

 

115Vac operation

1 converter: 16A @ peak line; 2 converters: 23A @ peak line; 3 converters: 39A @ peak line

230Vac operation

1 converter: 32A @ peak line; 2 converters: 47A @ peak line; 3 converters: 78A @ peak line

Ride-through time (full load)

 

90/180Vac low line

5ms minimum

115/230Vac nominal line

40ms minimum

AC fail warning time

5ms minimum (low line, full load)

AC and BUS OK (2 converter and 3 converter models only)

Off state

Vce = 70V maximum

On state

Vcesat = 0.4V maximum @ 1mA (1.5mA max.)

Module disable (2 converter and 3 converter models only, optically isolated LED input)

Continuous forward current

1 mA to 30mA

Forward voltage

1.65V max. at 30mA

Dielectric withstand

 

Primary to chassis GND

2,121Vdc

Primary to secondary

4,242Vdc

Secondary to chassis GND

707Vdc

Output Characteristics (applies to each output individually)

 

 

E-Grade

 

 

C-, I-Grade

 

 

 

 

MIN.

TYP.

MAX.

MIN.

TYP.

MAX

UNITS

NOTES

Setpoint accuracy

 

1%

2%

 

0.5%

1%

VNOM

 

Load/line regulation

 

 

0.5%

 

0.05%

0.2%

VNOM

LL to HL, 10% to Full Load

Load/line regulation

 

 

1%

 

0.2%

0.5%

VNOM

LL to HL, No Load to full load

Output temperature drift

 

0.02

 

 

0.01

0.02

%/°C

Over rated temperature

Long term drift

 

0.02

 

 

0.02

 

%/1k hours

 

Output ripple

 

 

 

 

 

 

 

 

2V

 

 

150mV

 

60mV

100mV

p-p

20MHz bandwidth

5V

 

 

5%

 

2%

3%

p-p

20MHz bandwidth

10-48V

 

 

3%

 

0.75%

1.5%

p-p

20MHz bandwidth

Output voltage trimming1

50%

 

110%

50%

 

110%

 

 

Total remote sense

 

 

 

 

 

 

 

 

compensation

0.5

 

 

0.5

 

 

Volts

0.25V max. neg. leg

OVP setpoint

 

125%

 

115%

125%

135%

VNOM

Recycle power

Current limit

105%

 

135%

105%

 

125%

INOM

Automatic restart

Short circuit current 2

20%

 

140%

20%

 

130%

INOM

 

Thermal Characteristics

 

 

 

 

 

 

 

 

Efficiency

 

78-88%

 

 

80-90%

 

 

 

Shutdown temp. — case

90

95

105

90

95

105

°C

Cool and recycle power to restart

Operating temp. — case

 

 

85

 

 

85

°C

See Thermal Curves

 

 

 

 

 

 

 

 

 

Mechanical Specifications

 

 

 

 

 

 

 

 

Weight3

 

22.4 (652)

 

 

22.4 (652)

 

Ounces (Grams)

 

 

 

 

 

 

 

 

 

Safety Agency Approvals

 

 

 

 

 

 

 

 

UL, CSA, TÜV, VDE, IEC 950, CE Marked for low voltage directive, 73/23/EEC

 

 

 

 

 

 

 

 

 

 

 

 

Environmental Characteristics/Product Grade Designators

 

 

 

 

 

 

Storage temperature

-20°C to +100°C (C-grade and E-grade)

 

 

 

 

 

 

-55°C to +100°C (I-grade)

 

 

 

 

 

 

Operating temperature (case)

0°C to +85°C (C-grade and E-grade)

 

 

 

 

 

 

-30°C to +85°C (I-grade)

 

 

 

 

 

 

 

 

 

 

EMI / EMC Characteristics (Performed on selected samples representative of the U Series FlatPac product family.)

 

 

 

Conducted emissions, LISN

EN 55022 and FCC R&R, Part 15, Subpart B, Class B

 

 

 

 

Electrostatic discharge

IEC 801-2, 1991, Level 4; ±8kV Contact, ± 15kV Air Discharge

 

 

 

RF radiated immunity, E-field

IEC 801-3, 1984; 27MHz to 500MHz, 3 V/M, CW

 

 

 

 

Electrical fast transients/burst

EN 61000-4-4, Level 2; ±1kV,

 

 

 

 

 

Surge immunity

EN 61000-4-5, Class 3; ±2kV Line to Ground, ±1kV Line to Line

 

 

 

110, 12V and 15V outputs, trim range ±10%. Consult factory for wider trim range.

2Output voltages of 5V or less incorporate foldback current limiting, greater than 5V incorporate straight line current limiting.

3For MU, PU series, multiply value by 2; for NU, QU, RU series, multiply value by 3.