25 to 600 Watts DC-DC Converters Single, Dual, Triple Output Chassis Mount

Features

Inputs: 10 to 400Vdc

Any Output, 1 to 95Vdc

UL, CSA, TÜV, VDE, BABT

CE Marked

80-90% Efficiency (Typical)

Up to 27W/Cubic Inch

1 Up

2.58" x 2.5" x 0.62" (Junior) 4.9" x 2.5" x 0.62" (Full Size)

2 Up

2.58" x 4.9" x 0.62" (Junior) 4.9" x 4.9" x 0.62" (Full Size)

3 Up

2.58" x 7.3" x 0.62" (Junior) 4.9" x 7.3" x 0.62" (Full Size)

ZCS Power Architecture

Low Noise FM Control

Booster Versions Available for Expanded Output Power-Full size only

Product Highlights

Vicor’s Mega Module and Mega Module Jr. Families of single, dual and triple output DC-DC converters provide power system designers with cost effective, high performance, off-the-shelf solutions to applications that might otherwise require a custom supply.

Incorporating standard VI-200 or VI-J00 Family converters in rugged, chassis mount packages, Mega Module and Mega Module Jr.’s can be ordered with single, dual or triple outputs, having a combined output power of up to 600W. Totally isolated outputs eliminate efficiency penalties and output interaction problems.

Configuration Chart

Full-Size Modules

Mega Modules:

 

 

 

# of Modules

Single Output

VI-L

-

50-200W

4.9" x 2.5" x 0.62"

1

 

VI-M

-

100-400W

4.9" x 4.9" x 0.62"

2

 

VI-N

-

300-600W

4.9" x 7.3" x 0.62"

3

Dual Output

VI-P

-

100-400W

4.9" x 4.9" x 0.62"

2

 

VI-Q

-

150-600W

4.9" x 7.3" x 0.62"

3

Triple Output

VI-R

-

150-600W

4.9" x 7.3" x 0.62"

3

Junior-Size Modules

 

 

 

 

Mega Module Juniors:

 

 

 

 

Single Output

VI-LJ

-

25-100W

2.58" x 2.5" x 0.62"

1

Dual Output

VI-PJ

-

50-200W

2.58" x 4.9" x 0.62"

2

Triple Output

VI-RJ

-

75-300W

2.58" x 7.3" x 0.62"

3

 

 

 

 

 

 

Input Voltage

 

 

 

Output Voltage

 

 

 

 

 

 

 

 

Mega

Mega

 

Z

=

2V

 

 

Nominal

Range

Brownout*

Transient**

Module Module Jr.

 

Y

=

3.3V

0

=

12V

10

-

20V

n/a

22

(4)

(1)

 

0

=

5V

1

=

24V

21

-

32V

18

36

(8)

(5)

 

M

=

10V

W=

24V

18

-

36V

n/a

n/a

(8)

(5)

 

1

=

12V

2

=

36V

21

-

56V

18

60

(6)

(1)

 

2

=

15V

3

=

48V

42

-

60V

36

72

(10)

(5)

 

3

=

24V

N =

48V

36

-

76V

n/a

n/a

(10)

(5)

 

L

=

28V

4

=

72V

55

- 100V

45

110

(9)

(4)

 

4

=

48V

T =

110V

66

- 160V

n/a

n/a

(8)

(5)

 

 

 

 

5

=

150V

100

- 200V

85

215

(9)

(5)

 

(1 to 95V, consult factory)

6

=

300V

200

- 400V

170

425

(10)

(6)

 

 

 

 

7

= 150/300V

100

- 375V

90

n/a

(5)

(1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Grade

 

 

Mega Module

Mega Module Jr.

E

=

-10°C

to +85°C

-10°C to +100°C

C

=

-25°C

to +85°C

-25°C to +100°C

I

=

-40°C

to +85°C

-40°C

to +100°C

M

=

-55°C

to +85°C

-55°C

to +100°C

Refers to Baseplate Temperature

Output Power/Current

VOUT

5V

VOUT < 5V

W

=

100W

W

=

20A

V

=

150W

V

=

30A

U

=

200W

U

=

40A

S

=

300W

S

=

60A

Q

=

400W

Q

=

80A

Output Power/Current

 

Mega Module

Mega Module Jr.

VOUT 5V

VOUT < 5V

VOUT 5V

VOUT < 5V

Y =

50W

Y = 10A

Z =

25W

Z = 5A

X =

75W

X = 15A

Y =

50W

Y = 10A

W = 100W

W = 20A

X =

75W

X = 15A

V = 150W

V = 30A

W = 100W

W = 20A

U = 200W

U = 40A

 

 

 

Output Power/Current

VOUT

5V

VOUT < 5V

S

=

300W

S

=

60A

P

=

450W

P

=

90A

M

=

600W

M

=

120A

Max. Output Per Module

5V Outputs

>5V Outputs

<5V Outputs

Max. Output Per Module

5V Outputs

>5V Outputs

<5V Outputs

(1)

50W

50W

10A

(7)

100W

150W

30A

 

 

 

 

 

 

 

 

 

(4)

75W

75W

15A

(8)

150W

150W

30A

 

 

 

 

 

 

 

 

 

(5)

75W

100W

20A

(9)

150W

200W

40A

 

 

 

 

 

 

 

 

 

(6)

100W

100W

20A

(10)

200W

200W

40A

*Brownout 75% of rated load. **Transient voltage for 1 second.

***Consult factory for availability of “T” input Mega Module Jrs.

102

121-800-735-6200

Mega Module Specifications

(typical at TBP = 25°C, nom. line and 75% load, unless otherwise specified)

 

Mega Module (E-Grade)

Mega Module (C-, I-, M-Grade)

 

 

PARAMETER

MIN.

TYP.

MAX.

MIN.

TYP.

 

MAX.

UNITS

TEST CONDITIONS

Input Characteristics

 

 

 

 

 

 

 

 

 

 

 

Inrush charge

 

120x10-6

 

 

120x10-6

200x10-6

Coulombs

Nom. line, per module

Input reflected ripple current – pp

 

10%

 

 

 

10%

 

 

 

IIN

Nom. line, full load

Input ripple rejection

 

25+20Log(

Vin

)

 

30+20Log(

Vin

)

dB

120 Hz, nom. line

 

 

Vout

 

Vout

 

 

 

 

 

 

 

 

20+20Log(

Vin

)

dB

2400 Hz, nom. line

 

 

 

 

 

 

Vout

 

 

No load power dissipation

 

1.35

 

2

 

1.35

 

2

Watts

Per module

Output Characteristics

 

 

 

 

 

 

 

 

 

 

 

Setpoint accuracy

 

1%

 

2%

 

0.5%

 

1%

VNOM

 

Load/line regulation

 

 

 

0.5%

 

0.05%

0.2%

VNOM

LL to HL, 10% to FL

Load/line regulation

 

 

 

1%

 

0.2%

 

0.5%

VNOM

LL to HL, NL to 10%

Output temperature drift

 

0.02

 

 

 

0.01

 

0.02

% / °C

Over rated temp.

Long term drift

 

0.02

 

 

 

0.02

 

 

 

%/1K hours

 

Output ripple - pp:

 

 

 

 

 

 

 

 

 

 

 

2V, 3.3V

 

 

 

150

 

60

 

100

mV

20 MHz bandwidth

5V

 

 

 

5%

 

2%

 

3%

 

20 MHz bandwidth

10-48V

 

 

 

3%

 

0.75%

1.5%

 

20 MHz bandwidth

High/low program 1

50%

 

 

110%

50%

 

 

110%

 

 

Total remote sense compensation

0.5

 

 

 

0.5

 

 

 

 

Volts

0.25V max. neg. leg

OVP setpoint2

 

125%

 

 

115%

125%

 

135%

VNOM

Recycle power

Current limit

105%

 

 

135%

105%

 

 

125%

INOM

Automatic restart

Short circuit current 3

20%

 

 

140%

20%

 

 

130%

INOM

 

Control Pin Characteristics

 

 

 

 

 

 

 

 

 

 

 

Gate out impedance

 

50

 

 

 

50

 

 

 

Ohms

 

Gate in impedance

 

103

 

 

 

103

 

 

 

Ohms

 

Gate in open circuit voltage

 

6

 

 

 

6

 

 

 

Volts

Use open collector

Gate in low threshold

0.65

 

 

 

0.65

 

 

 

 

Volts

 

Gate in low current

 

 

 

6

 

 

 

6

mA

 

Power sharing accuracy

.95

 

 

1.05

0.95

 

 

1.05

 

 

Dielectric Withstand Characteristics

 

 

 

 

 

 

 

 

 

 

 

Input to output

3,000

 

 

 

3,000

 

 

 

 

VRMS

Baseplate earthed

Output to baseplate

500

 

 

 

500

 

 

 

 

VRMS

 

Input to baseplate

1,500

 

 

 

1,500

 

 

 

 

VRMS

 

Thermal Characteristics

 

 

 

 

 

 

 

 

 

 

 

Efficiency

 

78-88%

 

 

80-90%

 

 

 

 

Baseplate to chassis

 

0.1

 

 

 

0.1

 

 

 

°C/Watt

 

Thermal Shutdown

90

95

 

105

90

95

 

105

°C

Cool and recycle

(Drivers only)Baseplate

 

 

 

 

 

 

 

 

 

 

power to restart

Mechanical Specifications

 

 

 

 

 

 

 

 

 

 

 

Weight

 

 

 

 

 

 

 

 

 

 

 

1 Up

 

9.0 (255)

 

 

9.0 (255)

 

 

Ounces (Grams)

 

2 Up

 

1.2 (545)

 

 

1.2 (545)

 

 

Lbs. (Grams)

 

3 Up

 

1.7 (772)

 

 

1.7 (772)

 

 

Lbs. (Grams)

 

110V,12V and 15V outputs, standard trim range ±10%. Consult factory for wider trim range. 2131% typical for booster modules.

3Output voltages of 5V or less incorporate foldback current limiting; outputs of 10V and above contain straight-line limiting.

103

Loading...
+ 2 hidden pages