VICOR VI-LAIM-M1, VI-LAIM-I1, VI-LAIM-E1, VI-LAIM-C1, VI-AIM-I1 Datasheet

...
0 (0)
VICOR VI-LAIM-M1, VI-LAIM-I1, VI-LAIM-E1, VI-LAIM-C1, VI-AIM-I1 Datasheet

45

Features

Universal Input: 85 to 264Vac

Output Power: 250W

Operating Temperature: 100°C

Efficiency: 97%

Integral EMI Filtering

Input Transient Protection

Inrush Limiting

CE Marked

VI-AIM

Compatible DC-DC

Input Voltage

Converter

 

 

85-132Vac

VI-X5X

 

 

180-264Vac

VI-X6X

 

 

85-264Vac

VI-X7X

 

 

Product Highlights

The AIM (Alternating Input Module) is an AC front-end module which interfaces directly with worldwide AC mains. The AIM provides line rectification, EMI/RFI filtering, transient protection and inrush limiting in a half brick package measuring 2.28" x 2.4" x 0.5".

The AIM is used in conjunction with Vicor VI-200 or VI-J00 DC-DC converters to realize a universal AC input, high density, low profile switching power supply with outputs from 1-95Vdc and a total power rating up to 200W. An external capacitor is used to satisfy system hold up requirements. Internal EMI filtering meets EN55022 and FCC part 15, class A emissions limits.

VI-AIM Selection Chart

 

PC Mount

 

 

VI-AIM-E1

VI-AIM-I1

VI-AIM-C1

VI-AIM-M1

 

Mega Module packaging option

 

 

VI-LAIM-E1

VI-LAIM-I1

VI-LAIM-C1

VI-LAIM-M1

 

 

Data Sheet

VI-AIM

Universal AC Input Front End Module

Shown actual size: 2.28 x 2.4 x 0.5 in 57,9 x 61,0 x 12,7 mm

VI-AIM Specifications

(typical at TBP = 25°C, nominal line, 75% load unless otherwise specified)

Parameter

Specifications

AC Line Input

85Vac to 264Vac*

 

47 Hz to 440 Hz

Output Voltage

120-373 Vdc

Efficiency

97%

Output Power

250W

Holdup Time

Application specific

Maximum Value of

1200 µF

Holdup Capacitance

 

Conducted EMI/RFI

VDE 0871/FCC Part 15, Class A

 

EN 55022, Class A

Inrush Current

<40A at Peak Line (264 Vrms)

Transient Surge Withstand

 

Common Mode

1.2/50 µS, 2 kV Pulse, 2 Joules

 

0 to 360 Degree Phase Angle

Normal Mode

1.2/50 µS, 1 kV Pulse, 2 Joules

 

0 to 360 Degree Phase Angle

Dielectric Withstand

 

Input to Output

None

Input/Output to Baseplate

1,500 Vrms

Thermal Resistance

0.4°C/Watt

Safety Approvals

UL 1950, CSA 22.2-950, EN 60950

Size

2.28" x 2.4" x 0.5"

 

(57,9 x 61,0 x 12,7)

 

packages available

Weight

3.0 Ounces (85 Grams)

Remarks

No strapping; no damage below low line Peak of AC line

Delivered to converter(s) A function of external capacitance and power

With compatible DC-DC converter modules. External 0.47µF capacitor required.

EN61000-4-5

IEC 801-5

With external MOV

Provided by DC-DC converter

Baseplate-to-sink

Mega Module,

SlimMOD and FinMOD

*Dependent upon input range of compatible DC-DC converter.

Product Grade Specifications

Parameter

E-Grade

C-Grade

I-Grade

M-Grade

Storage Temperature

-20°C to +105°C

-40°C to +105°C

-55°C to +105°C

-65°C to +105°C

Operating Temperature

-10°C to +100°C

-25°C to +100°C

-40°C to +100°C

-55°C to +100°C

(Baseplate)

 

 

 

 

 

 

 

 

 

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715

AIM, Universal AC Input Front End Module

Rev. 2.1

Page 1 of 2

Set your site on VICOR at www.vicorpower.com

Loading...
+ 1 hidden pages