VICOR VI-ARM-H11, VI-ARM-C2S, VI-ARM-C22, VI-ARM-C21, VI-ARM-C1S Datasheet

...
0 (0)

45

VI-ARMTM

 

Autoranging Rectifier Modules

Features

Up to 1500 Watts

Autoranging input

Microprocessor controlled

VI-ARM-1

500 Watts @ 90-132Vac

750 Watts @ 180-264Vac

VI-ARM-2

1000 Watts @ 90-132Vac

1500 Watts @ 180-264Vac

96-98% Efficiency

100˚C baseplate (no derating)

UL, CSA, TÜV, VDE, BABT

AC Bus OK, module enable

Inrush limiting (no external circuitry)

CE Marked

Typical Applications: systems requiring a rugged, full featured interface to the AC mains in the smallest possible package.

Product Highlights

The ARM (Autoranging Rectifier Module) is an AC front end module which provides autoranging line rectification and inrush current limiting. The ARM is available in either 500/750W or 750/1000W models in a mini sized package measuring only 2.28" x 1.45" x 0.5".

The ARM interfaces directly with worldwide AC mains and may be used with Vicor 1st or 2nd Generation 300V input DC-DC converters to realize an autoranging, high density, low profile switching power supply. The ARM includes a microcontroller that continuously monitors the AC line to control bridge/doubler operation. The user need only provide external capacitance to satisfy system hold-up requirements.

Actual size: 2.28 x 1.45 x 0.5 in

57,9 x 36,8 x 12,7 mm

Absolute Maximum Ratings

 

Parameter

Rating

 

 

 

 

 

VI-ARM-1/VI-ARM-2

Unit

Notes

 

L to N

264

Vac

 

 

 

L to N

280

Vac

100ms

 

+Out to –Out

400

Vdc

 

 

 

B OK to –Out

16

Vdc

 

 

 

EN to –Out

16

Vdc

 

 

 

Output power

500/1000

Watts

90-132Vac

 

 

750/1500

Watts

180-264Vac

 

Mounting torque

4 - 6 (0.45 - 0.68)

inlbs (N-m)

6 each, 4-40 screw

 

Pin soldering temperature

500 (260)

°F (°C)

<5 sec; wave solder

 

Pin soldering temperature

750 (390)

°F (°C)

<7 sec; hand solder

 

Storage temperature, C–,& T– Grade –40 to +125

°C

Baseplate

 

Operating temperature, C– Grade

–20 to +100

°C

Baseplate

 

Operating temperature, T– Grade

–40 to +100

°C

Baseplate

 

 

 

 

 

 

Thermal Resistance and Capacity

 

Parameter

Typ

Unit

 

 

Baseplate to sink; flat, greased surface

0.24

°C/Watt

 

Baseplate to sink; with thermal pad (P/N 16495)

0.3

°C/Watt

 

Baseplate to ambientfree convection

15

°C/Watt

 

Baseplate to ambient; 1000 LFMforced air

2.7

°C/Watt

 

Thermal capacity

48

Watt-sec/°C

Vicor 2nd Generation packaging technology offers flexible mounting options for various manufacturing processes. The ARM may be installed as a conventional leaded device for on-board applications, in-board for low profile, height restricted applications, socketed or surface mounted with optional ModuMate interconnect products.

Part Numbering

VI-ARM-

 

C

 

 

 

1

 

 

2

 

 

 

 

 

 

 

 

 

 

 

Product

 

 

Product Grade

 

Type

 

 

Pin Style*

 

C = –20°C to +100°C

 

1 = 500/1000W

 

 

1 = Short

 

 

 

 

 

 

 

T = –40°C to +100°C

 

2 = 750/1500W

 

 

2 = Long

 

 

H = –40°C to +100°C

 

 

 

 

 

S=Short Modumate

 

 

 

 

 

 

M = –55°C to +100°C

 

 

 

 

 

N=Long Modumate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Pin styles S & N are compatible with the ModuMate interconnect system for socketing and surface mounting.

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715

ARM, Autoranging Rectifier Module

Rev. 2.4

Page 1 of 12

Set your site on VICOR at www.vicorpower.com

Electrical Characteristics

Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Specifications apply for AC mains having up to 5% total harmonic distortion.

MODULE INPUT SPECIFICATIONS

 

 

VI-ARM - 1

 

VI-ARM - 2

 

 

 

 

 

 

 

 

 

 

 

Parameter

Min Typ

Max

Min Typ

Max

Unit

Notes

Operating input voltage

90

132

90

132

Vac

Autoranging (doubler mode)

Operating input voltage

180

264

180

264

Vac

Autoranging (bridge mode)

Input undervoltage

 

 

90

 

 

90

Vac

No damage

Input surge withstand

 

 

280

 

 

280

Vac

100ms

AC line frequency

47

63

47

63

Hz

C-Grade

AC line frequency

47

880

47

880

Hz

T-Grade

Input current, rms

0

7.4

0

14.8

Amps

120Vac

Input current, rms

0

5.4

0

10.8

Amps

240Vac

Power factor

0.60

 

 

0.60

 

 

 

Typical line voltage condition

Inrush current

 

 

30

 

 

60

Amps

264Vac peak line, cold start

Holdup capacitance

 

 

1600

 

 

3300

µF

 

 

 

 

 

 

 

 

 

 

 

 

MODULE OUTPUT SPECIFICATIONS

 

 

VI-ARM - 1

 

VI-ARM - 2

 

 

 

 

 

 

 

 

 

 

 

Parameter

Min

Typ Max

Min

Typ Max

Unit

Notes

Output power

0

500

0

1000

Watts

90-132Vac

Output power

0

750

0

1500

Watts

180-264Vac

Efficiency, 120Vac

94

96

 

94

96

 

%

 

Efficiency, 240Vac

96

98

 

96

98

 

%

 

Output voltage

200

375

200

375

Vdc

90-264Vac

 

 

 

 

 

 

 

 

 

 

 

SAFETY SPECIFICATIONS

Parameter

Min

Typ

Max

Unit

Notes

 

 

Agency approvals

 

 

 

 

UL 1950, CSA 22.2 No. 950,

 

 

 

 

 

TÜV, VDE, EN60950, CE Marked

 

 

 

 

 

 

 

Isolation voltage (in to out)

None

 

 

 

Isolation provided by DC-DC converter(s)

 

Isolation voltage (I/O to baseplate)

1500

 

 

Volts, rms

 

 

 

Leakage current

 

 

100

µA

No filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715

 

ARM, Autoranging Rectifier Module

Rev. 2.4

Page 2 of 12

Set your site on VICOR at www.vicorpower.com

Electrical Characteristics, continued

MODULE CONTROL SPECIFICATIONS

Parameter

Min

Typ

Max

Unit

Notes

AC Bus OK (B OK)

 

 

 

 

 

On-state resistance (low)

 

 

15

To negative output - bus normal

On-state current (low)

 

 

-50

mA

Bus normal

Off-state voltage

14.8

15.0

15.2

Vdc

Bus abnormal, 27K internal pull up to 15Vdc (Fig. 10)

On-state threshold

235

240

245

Vdc

Output bus voltage

Off-state threshold

200

205

210

Vdc

Output bus voltage

Module Enable (EN)

 

 

 

 

 

On-state resistance (low)

 

 

15

To negative output - converters are disabled

On-state current (low)

 

 

50

mA

 

Off-state voltage

14.8

15.0

15.2

Vdc

150K internal pull up to 15Vdc (Fig. 9)

On-state threshold

235

240

245

Vdc

Output bus voltage

Off-state threshold

200

205

210

Vdc

Output bus voltage

Over voltage shutdown

380

390

400

Vdc

 

 

 

 

 

 

 

AC Bus OK - module enable, differential error*

15

17

20

Vdc

AC Bus OK and module enable thresholds track

* Tracking error between BUS OK and Enable thresholds

MODULE GENERAL SPECIFICATIONS

Parameter

Min

Typ

Max

Unit

Notes

MTBF

 

>1,000,000

 

hours

25˚C, ground benign

Baseplate material

 

 

 

 

Aluminum

Cover

 

 

 

 

Polyetherimide

Pin material

 

 

 

 

Copper, tin/lead solder dipped

Weight

 

2.1 (60)

 

ounces (grams)

 

Size

 

2.28 x 1.45 x 0.5

 

inches

 

 

(57,9 x 36,8 x 12,7)

 

(mm)

 

 

 

 

 

 

 

 

 

 

 

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715

ARM, Autoranging Rectifier Module

Rev. 2.4

Page 3 of 12

Set your site on VICOR at www.vicorpower.com

VICOR VI-ARM-H11, VI-ARM-C2S, VI-ARM-C22, VI-ARM-C21, VI-ARM-C1S Datasheet

Operating Characteristics

Vdc output

Strap

Engaged

Enable

B OK

Figure 1—Start-up at 120Vac input

Vdc output

Iac input @2A / mV

Enable

B OK

Figure 3—Power down, from 120Vac

Vdc output

Enable

B OK

Figure 5—Output overvoltage protection 240Vac range

Vdc output

Enable

Enable

B OK

Figure 2—Start-up at 240Vac input

Vdc output

Iac input @2A / mV

Enable

B OK

Figure 4—Power down, from 240Vac

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715

ARM, Autoranging Rectifier Module

Rev. 2.4

Page 4 of 12

Set your site on VICOR at www.vicorpower.com

Loading...