121-800-735-6200
VI-IAM ™
Input Attenuator
Modules
Features
■Inputs: 24, 48 and 300Vdc
■High Surge Withstand:
–Bellcore
–British Telecom BTR 2511
–IEC-60801-5
■EMI/RFI Specifications:
–Bellcore TR-TSY-000513
–British Telecom BTR 2511
–FCC Level “A”
–EN55022 Level “B”
■UL, CSA, TÜV, VDE, BABT
■97% Efficiency
■Input Reverse Polarity Protection
■Logic Disable
■Expansion Output for Arrays
■Size: 2.28" x 2.4" x 0.5" (57,9 x 61,0 x 12,7)
■CE Marked
Product Highlights
The Input Attenuator Module (VI-IAM) is a component-level, DC input front end filter designed to occupy minimum board space while providing maximum protection for today’s sophisticated electrical systems. The VI-IAM, in combination with Vicor 24, 48 and 300Vdc input modules, provides a highly efficient, high density power system with outputs from
1 to 95Vdc and power expandable from
25 to 800W. Your system will benefit from the small size, efficiency and inherent reliability of Vicor’s component-level converters, while meeting the toughest demands of Telecommunications and Industrial power applications.
This combination provides compliance with the transient requirements of Bellcore, British Telecom and IEC standards, and meets the EMI/RFI specifications of Bellcore, British Telecom and FCC Part 15, Subpart B and EN55022.
Compatible Products
■VI-200 and VI-J00 (Inputs: 1, W, 3, N and 6)
■Mega Modules
(Inputs: 1, W, 3, N and 6)
VI-IAM Specifications
(typical at TBP = 25°C, nominal line, 75% load, unless otherwise specified)
PARAMETER |
MIN |
TYP |
MAX |
POWER |
REMARKS |
Input Range/Power Limit |
|
|
|
|
|
VI-A11-CU |
21Vdc |
24Vdc |
32Vdc |
200W |
Delivered power is |
VI-AWW-CU |
18Vdc |
24Vdc |
36Vdc |
200W |
from any combination |
VI-A33-CQ |
42Vdc |
48Vdc |
60Vdc |
400W |
of DC-DC converters |
VI-ANN-CQ |
36Vdc |
48Vdc |
76Vdc |
400W |
|
VI-A66-CQ |
200Vdc |
300Vdc |
400Vdc |
400W |
|
Isolation |
|
1,500 VRMS |
|
|
Input/Output to Base |
Size |
2.28" x 2.4" x 0.5" (57,9 x 61,0 x 12,7) |
|
|||
Weight |
3.0 Ounces (85 Grams) |
|
|
||
EMI/ RFI (conducted |
Meets Bellcore TR-TSY-000513, Issue 2, Rev. 1 |
||||
emissions) |
(24 and 48V Input); |
|
|
||
|
British Telecom BTR 2511, Issue 2 |
|
|||
|
(24 and 48V Input); |
|
|
||
|
FCC Part 15, Class A, EN55022 Class B |
|
|||
Transient Protection |
Meets Bellcore TA-TSY-001003, Issue 1, 9/89 |
||||
|
British Telecom BTR 2511, IEC 61000-4-5 Level 2(VI-A66 only) |
Reverse Polarity Protection No damage to unit
Product Grade Specifications
|
|
PRODUCT GRADE |
|
|
PARAMETER |
E |
C |
I |
M |
Storage Temp. |
–20°C to +105°C |
–40°C to +105°C |
–55°C to +105°C |
–65°C to +105°C |
Operating Temp. |
–10°C to +100°C |
–25°C to +100°C |
–40°C to +100°C |
–55°C to +100°C |
(Baseplate) |
|
|
|
|
Note: For alternative product grades, change the “C” in the part number to “E”, “I” or “M”
Long Term Safe Operating Area Curves
(1% duty cycle max., Zs = .5Ω , for short duration transient capability refer to specifications)
Standard 24V Inputs Wide Range 48V Input
100V |
|
|
|
|
R.E. |
|
|
100V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
160V |
|
|
|
|
R.E. |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
I.S.W. |
|
S.D. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Full Load |
|
100V |
|
I.S.W. |
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
32V |
|
|
|
|
|
|
|
36V |
60V |
|
Full Load |
|
S.D. |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
Normal Operating Area |
|
Normal Operating Area |
|||||||||||||
|
|
|
|
|
|
|
||||||||||
21V |
|
|
|
|
18V |
42V |
|
|
|
|
|
|
||||
0.1 |
1 |
10ms |
100 |
1000 |
0.1 |
1 |
|
10ms |
100 |
1000 |
||||||
|
|
|
|
48V Wide Range Input |
|
|
|
|
300V Input |
|
|
276V |
|
R.E. |
|
|
800V |
|
R.E. |
|
|
|
|
|
|
|
|
|
|
|
|
125V |
I.S.W. |
|
|
100V |
500V |
I.S.W. |
|
|
|
76V |
Full Load |
|
S.D. |
400V |
Full Load |
S.D. |
|
||
|
|
|
|
|
|
|
|
||
|
Normal Operating Area |
|
S.D. |
Normal Operating Area |
|
||||
36V |
|
|
|
|
|
|
|
|
|
|
|
|
|
200V |
|
|
|
|
|
0.1 |
1 |
10ms |
100 |
1000 |
0.1 |
1 |
10ms |
100 |
1000 |
|
|
|
500 ms |
|
|
|