VICOR M-FIAM5MN1, M-FIAM5M22, M-FIAM5M21, M-FIAM5M13, M-FIAM5M12 Datasheet

...
0 (0)

45 M-FIAM5

Military 28Vin Filter Input Attenuator Module

Features

EMI filtering-MIL-STD-461E

Transient protection-MIL-STD-704E 1

Environments-MIL-STD-810, MIL-STD-202

Environmental stress screening

Low profile mounting options

Output current up to 20 Amps

Shown actual size:

Mini sized package

2.28 x 2.2 x 0.5 in

Inrush current limiting

57,9 x 55,9 x 12,7 mm

Reverse polarity protection

 

Product Highlights

The M-FIAM5 is a DC front-end module that provides EMI filtering and transient protection required in military applications. The M-FIAM5 enables designers using Vicor 2nd Generation 24V DC-DC converters to meet conducted emission/conducted susceptibility per MIL-STD-461E; and input transients per MIL-STD-704E1 . The M-FIAM5 accepts an input voltage of 18-36Vdc and delivers output current

up to 20 Amps.

M-FIAM5 is housed in an industry standard "half brick" module measuring 2.28" x 2.2" x 0.5" and depending upon model selected, may be mounted on-board or in-board for height critical applications.

Compatible Products

2nd Generation 24V Input DC-DC converters

Part Number Format

M-FIAM5 M 2 1

Product

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin Style

 

 

 

Product Grade(°C)

 

1

= Short

 

 

Baseplate

H = –40 to +100

 

2

= Long

 

1

= Slotted

M = –55 to +100

 

*S=Short ModuMate

 

2

= Threaded

 

 

 

*N=Long ModuMate

 

3

= Thru-hole

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Compatible with SurfMate and InMate socketing system.

Absolute Maximum Rating

Parameter

Rating

Unit

Notes

+In to –In

36

Vdc

Continuous

+In to –In

50

Vdc

100ms

Mounting torque

5(0.57)

in-lbs

6 each, #4-40 or M3

Pin Soldering temperature

500 (260)

°F(°C)

<5 sec; wave solder

Pin Soldering temperature

750 (390)

°F(°C)

<7 sec; hand solder

Operating temperature H–Grade

-40 to +100

°C

Baseplate

Storage temperature H–Grade

-55 to +125

°C

 

Operating temperature M–Grade

-55 to +100

°C

Baseplate

Storage temperature M–Grade

-65 to +125

°C

 

 

 

 

 

Specifications

(typical at TBP = 25ºC, nominal line, 75% load, unless otherwise specified)

Parameter

Min

Typ

Max

Remarks

Input voltage

18Vdc

28Vdc

36Vdc

Continuous

Output current

 

 

20A

 

Inrush limiting

 

 

0.007A/µF

 

Transient immunity

MIL-STD-704E

 

See footnote 1

EMI:MIL-STD-461E

 

 

 

 

Conducted emissions:

CE101, CE102

 

 

Conducted susceptibility: CS101, CS114, CS115, CS116

 

Dielectric withstand

 

1,500Vrms

 

Input/Output to Base

 

 

2,121Vdc

 

Input/Output to Base

Efficiency

96%

98%

 

 

Internal voltage drop

 

0.5

1.0

@20A, 100°C baseplate

ON/OFF control

 

 

 

 

Enable (ON)

0.0Vdc

 

1.0Vdc

Referenced to –Vout.

Disable (OFF)

3.5Vdc

 

5.0Vdc

100kΩ internal pull-up resistor

External capacitance

 

 

 

See illustration C1 on page 3.

 

330µF

 

1000µF

50V

Weight

 

3.1 (88)

4 (113)

Ounces (grams)

Warranty

 

 

2

Years

1 MIL-STD-704E Compliance requires an external circuit. See addendum A

Thermal Resistance

Parameter

Typ

Baseplate to sink; flat, greased surface

0.16°C/Watt

Baseplate to sink; thermal pad (P/N 20264)

0.1°C/Watt

Baseplate to ambient

7.9°C/Watt

Baseplate to sink; 1000 LFM

2.2°C/Watt

 

 

MTBF per MIL-HDBK-217F

Temp

Environment

MTBF

Unit

25°C

Ground Benign:G.B.

3,334,295

Hrs

50°C

Naval Sheltered:N.S.

786,893

Hrs

65°C

Airborne Inhabited Cargo:A.I.C.

650,187

Hrs

 

 

 

 

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715

MFIAM5

Rev. 1.7

Page 1 of 5

Set your site on VICOR at www.vicorpower.com

VICOR M-FIAM5MN1, M-FIAM5M22, M-FIAM5M21, M-FIAM5M13, M-FIAM5M12 Datasheet

Environmental Qualification

Altitude

MIL-STD-810C, Method 500.2, Procedure I & II, 40,000 ft. and 70,000 ft. Operational.

Explosive Atmosphere

MIL-STD-810F, Method 511.4, Procedure I, Operational.

Vibration

MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor with overall level of 5.6 grams for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17 with overall level of 7.7 grams

for 1 hour per axis.

Shock

MIL-STD-810-F, Method 516.5, Procedure I, Functional Shock,40 G's. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft. MIL-STD-202F, Method 213B, 60 G's, 9ms half sine. MIL-STD-202F, Method 213B, 75 G's, 11ms Saw Tooth Shock.

Acceleration

MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 G's, 6 directions.

Humidity

MIL-STD-810F, Method 507.4, Procedure I, Cycle I, 240 hrs, 95% RH.

Solder Test

MIL-STD-202F, Method 208, 8 hour aging.

Environmental Stress Screening

 

H Grade

M Grade

Operating Temp.

-40°C to +100°C

-55°C to +100°C

Storage Temp.

-55°C to +125°C

-65°C to +125°C

Temp. Cycling:*

12 cycles

12 cycles

-65°C to +100°C

-65°C to +100°C

 

Ambient Test

Yes

Yes

@ 25°C

 

 

Power Cycling

12 hours,

24 hours,

Burn-In:

28 cycles

56 cycles

Functional and

-40°C and

-55°C and

Parametric

+100°C

+100°C

ATE Tests:

 

 

Hi-Pot Test

Yes

Yes

Visual Inspection:

Yes

Yes

Test Data

vicorpower.com

vicorpower.com

 

 

 

*Temperature cycled with power off, 17°C per minute rate of change.

Conducted Noise

Transient Immunity

Figure 1– M-FIAM5 and Model V24A12M400A DC-DC converter operating at 28Vdc, 400W.

Inrush Limiting

Figure 2 – Transient Immunity: M-FIAM5 output response to an input transient.

Figure 3– Inrush Limiting: Inrush current with 1000µF external capacitance.

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715

MFIAM5

Rev. 1.7

Page 2 of 5

Set your site on VICOR at www.vicorpower.com

Loading...
+ 3 hidden pages