VICOR FM4812C12, FM4812C11, FM4808C12, FM4808C11 Datasheet

0 (0)
VICOR FM4812C12, FM4812C11, FM4808C12, FM4808C11 Datasheet

45

Features

Low Profile Mounting Option

EMI Filtering

8 and 12 Amp versions

CE Marked

Micro Sized Module

Products Highlights

The FM48 input filter module enables designers to meet the conducted emission limits of EN55022 level B and FCC level B when used with Vicor’s 48 Volt 2nd Generation of DC-DC converters. FiltMods accept an input voltage of 36 to 76 Vdc with a transient withstand capability of 100Vdc for 100 msec. The FiltMods are packaged in an industry standard “quarter-brick” module measuring 2.28" x 1.45" x 0.5" and are available in either 8 or 12 Ampere capacity. Both versions may be on-board or in-board mounted for height critical applications. The FiltMods can be teamed with Vicor’s IAM48 for transient and surge protection.

Compatible Products

IAM48

2nd Generation 48V input DC-DC converters

Part Numbers

FM4808C11: 8 Amp – Short Pins FM4808C12: 8 Amp – Long Pins FM4812C11: 12 Amp – Short Pins FM4812C12: 12 Amp – Long Pins

–IN

+IN

Data Sheet

FM48TM FiltMod

Input Filter Module

 

 

 

 

Shown actual size:

 

 

 

 

2.28 x 1.45 x 0.5 in

FM48-FiltMod Specifications

 

57,9 x 36,8 x 12,7 mm

 

 

(typical at TBP = 25°C, nominal line, 75% load, unless otherwise specified)

 

 

 

 

 

 

 

 

 

 

Parameter

Min

Typ

Max

Remarks

Input Voltage

36Vdc

48Vdc

76Vdc

 

Safety Approvals

UL 1950, CSA 22.2-950, EN 60950

 

Dielectric Withstand

1,500VRMS

 

Input/Output to Base

EMI/ RFI

Bellcore GR-001089-Core Issue 2

When used with Vicor 2nd

 

EN 55022 Level B

 

Generation 48Vin DC-DC converters

 

FCC Part 15 Level B

 

 

Output Current

 

 

 

 

FM4808C12

 

 

8A

Delivered current to any

FM4812C12

 

 

12A

combination of Vicor’s 2nd Generation

 

 

 

 

48Vin DC-DC Converter

Reverse Polarity Protection

 

 

 

No damage to unit, external

 

 

 

fusing required

 

 

 

 

Weight

2.1 Ounces (60 Grams)

 

 

 

 

Product Grade Specifications

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

C-Grade

 

T-Grade

Storage Temp.

 

–40°C to +125°C

–40°C to +125°C

Operating Temp. (Baseplate)

–20°C to +100°C

–40°C to +100°C

Warranty

 

2 years

 

2 years

 

 

 

 

 

Note: For alternative product grades, change the “C” in the part number to “T”.

Conducted Noise

FM4812C12 and Model V48A12C500A

FM4812C12 and Model V48B24C250A

DC-DC Converter.

DC-DC Converter.

Typical transient, surge protection and filtering solution

Note: The IAM48 is shown in the on state.

To disable, open the connection to pin 3.

 

 

 

 

 

–IN

 

–OUT

4

 

5

7

 

1

2nd Generation

–S

3

 

 

 

 

PR

FM48

6

6

IAM48IA 2

2

48Vdc Input

SC

2

 

 

 

 

3

DC-DC Converters

1

 

7

5

 

PC

+S

 

 

4

 

 

 

 

 

 

 

+IN

 

+OUT