45
Features
•Low Profile Mounting Option
•EMI Filtering
•8 and 12 Amp versions
•CE Marked
•Micro Sized Module
Products Highlights
The FM48 input filter module enables designers to meet the conducted emission limits of EN55022 level B and FCC level B when used with Vicor’s 48 Volt 2nd Generation of DC-DC converters. FiltMods accept an input voltage of 36 to 76 Vdc with a transient withstand capability of 100Vdc for 100 msec. The FiltMods are packaged in an industry standard “quarter-brick” module measuring 2.28" x 1.45" x 0.5" and are available in either 8 or 12 Ampere capacity. Both versions may be on-board or in-board mounted for height critical applications. The FiltMods can be teamed with Vicor’s IAM48 for transient and surge protection.
Compatible Products
•IAM48
•2nd Generation 48V input DC-DC converters
Part Numbers
FM4808C11: 8 Amp – Short Pins FM4808C12: 8 Amp – Long Pins FM4812C11: 12 Amp – Short Pins FM4812C12: 12 Amp – Long Pins
–IN
+IN
Data Sheet
FM48TM FiltMod
Input Filter Module
|
|
|
|
Shown actual size: |
|
|
|
|
2.28 x 1.45 x 0.5 in |
FM48-FiltMod Specifications |
|
57,9 x 36,8 x 12,7 mm |
||
|
|
|||
(typical at TBP = 25°C, nominal line, 75% load, unless otherwise specified) |
||||
|
|
|
|
|
|
|
|
|
|
Parameter |
Min |
Typ |
Max |
Remarks |
Input Voltage |
36Vdc |
48Vdc |
76Vdc |
|
Safety Approvals |
UL 1950, CSA 22.2-950, EN 60950 |
|
||
Dielectric Withstand |
1,500VRMS |
|
Input/Output to Base |
|
EMI/ RFI |
Bellcore GR-001089-Core Issue 2 |
When used with Vicor 2nd |
||
|
EN 55022 Level B |
|
Generation 48Vin DC-DC converters |
|
|
FCC Part 15 Level B |
|
|
|
Output Current |
|
|
|
|
FM4808C12 |
|
|
8A |
Delivered current to any |
FM4812C12 |
|
|
12A |
combination of Vicor’s 2nd Generation |
|
|
|
|
48Vin DC-DC Converter |
Reverse Polarity Protection |
|
|
|
No damage to unit, external |
|
|
|
fusing required |
|
|
|
|
|
|
Weight |
2.1 Ounces (60 Grams) |
|
||
|
|
|
||
Product Grade Specifications |
|
|
||
|
|
|
|
|
|
|
|
|
|
Parameter |
|
C-Grade |
|
T-Grade |
Storage Temp. |
|
–40°C to +125°C |
–40°C to +125°C |
|
Operating Temp. (Baseplate) |
–20°C to +100°C |
–40°C to +100°C |
||
Warranty |
|
2 years |
|
2 years |
|
|
|
|
|
Note: For alternative product grades, change the “C” in the part number to “T”.
Conducted Noise
FM4812C12 and Model V48A12C500A |
FM4812C12 and Model V48B24C250A |
DC-DC Converter. |
DC-DC Converter. |
Typical transient, surge protection and filtering solution
Note: The IAM48 is shown in the on state.
To disable, open the connection to pin 3.
|
|
|
|
|
–IN |
|
–OUT |
4 |
|
5 |
7 |
|
1 |
2nd Generation |
–S |
3 |
|
|
|
|
PR |
||
FM48 |
6 |
6 |
IAM48IA 2 |
2 |
48Vdc Input |
SC |
|
2 |
|
|
|
|
3 |
DC-DC Converters |
|
1 |
|
7 |
5 |
|
PC |
+S |
|
|
|
4 |
|
|
|||
|
|
|
|
|
+IN |
|
+OUT |
Set your site on VICOR at www.vicr.com