Data Sheet
FlatPAC-ENTM
EN Compliant, Autoranging Switcher
Features
•EN 61000-3-2 harmonic current compliance
•Low profile package (1.4"/35,6mm)
•Output power to 500W (425W for EN compliance)
•Up to 4 user specifiable outputs
•"Autosense" feature
•Compliant to EN 55022, Class A,
EN 55022, Class B (may require optional in-line filter), EN 61000-4-4 and EN 61000-4-5
•Rugged: Meets MIL-STD-810E for vibration
•Drop-in upgrade to our “2up” FlatPAC
•RS-232 microcontroller interface
•Safety agency approvals: TÜV, cULus, CE
Overview
With a power density greater than 7W/in3, Westcor’s FlatPAC-EN is an ultra low profile, compact, EN compliant autoranging AC-DC switcher. It is capable of providing up to 500 Watts from up to 4 isolated outputs.
For maximum versatility and flexibility, the FlatPAC-EN can be configured with standard Vicor DC-DC converter modules - full, half and quarter brick sizes. These modules cover the entire range of outputs from 1 to 100Vdc and 25 to 500 Watts, as well as an array of non-standard voltages. The optimum FlatPACEN solution can be factory configured based on your exact voltage and power requirements.
For conducted EMI, the FlatPAC-EN conforms with FCC Class A and B, and EN 55022,
Class A and B. Some configurations may require our optional external in-line filter to meet
EN 55022 Class B. Further, besides meeting the cULus, TÜV and CE safety agency approvals, the FlatPAC-EN complies with harmonic current limits per EN 61000-3-2,
Electrical Fast Transient/Burst per EN 61000-4-4 and Surge Immunity per EN 61000-4-5. For harmonic current compliance to EN 61000-3-2, do not exceed input current of 3.33 A rms at 230Vac, 50 Hz.
1.4"H x 5.0"W x 9.2"L 35,6 x 127,0 x 233,7 mm Up to 500W
1 to 4 Outputs
Part Numbering
|
FL |
|
|
X 1 |
|
- |
X 2 |
|
|
|
X 3 |
|
- |
X X X |
- |
E |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Product Prefix |
|
|
|
|
Number of |
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
Factory |
|
|
||||||||||
FL FlatPAC-EN |
|
|
|
|
1st Gen modules |
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
Assigned |
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Number of |
|
|
|
|
|
|
Number of |
|
|
|
|
|
|
|
||||
|
|
|
|
|
Output |
|
|
|
|
|
2nd Gen modules |
|
|
Extended |
||||||||
|
|
|
|
|
Voltages |
|
|
|
|
|
|
|
Temperature |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Range Version |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(Optional) |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Autosense Feature*
This is a new feature implemented in all converter slots in the FlatPAC-EN. If remote sense connections are not needed or are inadvertently not made, no
local sense connections are necessary. Simply connect the output(s) to the load and the converter(s) will automatically operate in the local sense mode. If remote sense connections are made, the unit will operate in remote sense mode.
*Applies to outputs utilizing Maxi or Mini size converters.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 |
FlatPAC-EN |
Rev. 1 |
Page 1 of 8 |
Set your site on VICOR at www.vicorpower.com
DC Output Selections
The tables below show a sampling of some of the most popular standard outputs that can be configured into the FlatPAC-EN.
|
Output |
|
|
Available Power (W) per Package Size |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
Maxi |
|
|
Mini |
|
Micro |
|
|
|
Voltage |
|
|
|
|
|
|||
|
|
2nd Gen |
|
1st Gen |
2nd Gen |
1st Gen |
|
2nd Gen |
|
|
|
|
|
|
|
|
|
|
|
|
2Vdc |
160 |
80 |
60 |
100 |
40 |
30 |
50 |
|
|
3.3Vdc |
264 |
132 |
99 |
150 |
66 |
50 |
75 |
|
|
5Vdc |
400 |
200 |
150 |
200 |
100 |
75 |
100 |
|
|
12Vdc |
500 |
200 |
150 |
250 |
100 |
75 |
150 |
|
|
15Vdc |
500 |
200 |
150 |
250 |
100 |
75 |
150 |
|
|
24Vdc |
500 |
200 |
150 |
250 |
100 |
75 |
150 |
|
|
28Vdc |
500 |
200 |
150 |
250 |
100 |
75 |
150 |
|
|
48Vdc |
500 |
200 |
150 |
250 |
100 |
75 |
150 |
|
|
|
|
|
|
|
|
|
|
|
FlatPAC-EN Configurations
Vicor’s DC–DC converter modules are used to populate the FlatPAC-EN. There are several configurations available depending on module size, power limitation and location of the MiniHAM*. The two-output FlatPAC-EN contains
1 Maxi and 1 Mini. The three-output FlatPAC-EN contains 3 Minis. The four output FlatPAC-EN contains 1 Mini and 3 Micros. See below.
FlatPAC-EN Configurations
Maximum Total Output Power = 500W (425W for EN61000-3-2 Compliance)
2 Output** |
|
MiniHAM |
|
|
Maxi |
Mini |
|
M1 |
M2 |
M1 |
M2 |
|
|
3 Output |
|
|
|
|
|
|
4 Output |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MiniHAM |
|
|
|
Mini |
|
|
|
|
MiniHAM |
|
|
Mini |
|
|||||
|
|
|
|
|
M3 |
|
|
|
|
|
|
|
|
|
|
M4 |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Mini |
|
|
|
Mini |
|
|
|
Micro |
|
Micro |
|
|
Micro |
|
||||
|
M1 |
|
|
|
M2 |
|
|
|
M1 |
|
M2 |
|
|
M3 |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
M1 |
|
|
M2 |
M3 |
|
|
|
|
M1 |
M2 |
M3 |
M4 |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: The FlatPAC-EN is limited to a maximum output power of 500W regardless of the module capability. For example, if three Mini modules are used, the maximum output power for the FlatPAC-EN is still 500W irrespective of the maximum output power of the modules. For EN 61000-3-2 harmonic current compliance, input current of 3.33 A rms should not be exceeded.
*The MiniHAM is a passive harmonic attenuator specifically designed for EN compliance. Unlike active PFC solutions, the MiniHAM generates no EMI, greatly simplifying and reducing system noise filtering requirements. It is also considerably smaller and more efficient than active alternatives and improves the unit’s MTBF. It will provide harmonic current compliance at 230Vac input at up to 425W of output power.
**For a single output configuration either M1 or M2 is used.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 |
FlatPAC-EN |
Rev. 1 |
Page 2 of 8 |
Set your site on VICOR at www.vicorpower.com
Performance Specifications
The following are typical performance specifications at room ambient temperature, nominal line voltage (115/230Vac) and 75% load on all outputs, unless specified otherwise. For detail specifications, consult the FlatPAC-EN Design Guide available online at (vicorpower.com).
INPUT CHARACTERISTICS
|
Parameter |
|
Typ |
Units |
Notes |
|
|
|
AC Input |
|
|
|
|
|
|
|
|
Voltage |
|
90-132/180-264 |
Vac |
Derates to 260W @ 90Vac, 400W @ 180Vac |
|
|
|
Frequency |
|
47-63 |
Hz |
|
|
|
|
|
|
|
|
|
|
|
DC Input |
|
250-380 |
Vdc |
|
|
|
|
Line Regulation |
|
0.2 |
% |
From low line to high line |
|
|
|
Inrush Current |
|
|
|
|
|
|
|
|
@ 115Vac |
|
8 |
A rms |
|
|
|
|
@ 230Vac |
|
8 |
A rms |
|
|
|
Ride Through Time |
|
|
|
|
|
|
|
|
@ 115Vac |
|
12/15 |
ms |
|
|
|
|
@ 230Vac |
|
16/18 |
ms |
|
|
|
|
@ Load |
|
500/400 |
W |
|
|
|
Conducted EMI/RFI |
FCC Class A, EN 55022 Class A |
|
|
|
||
|
|
|
FCC Class B, EN 55022 Class B |
|
EN 55022 Class B may need external |
|
|
|
|
|
|
|
|
optional in-line filter |
|
|
Power Factor |
|
> 0.70 |
|
>75% load |
|
|
|
Harmonic Current Limits |
|
EN 61000-3-2/A14 |
|
Input current of 3.33A rms max. at 230Vac, 50Hz |
|
|
|
Transient Burst Immunity |
|
EN 61000-4-4 |
|
|
|
|
|
Surge Immunity |
|
EN 61000-4-5 |
|
|
|
|
|
Voltage Dips |
|
EN 61000-4-11 |
|
Criteria B |
|
|
|
Dielectric Withstand |
|
|
|
|
|
|
|
|
Primary to Chassis GND |
|
1,500 |
Vrms |
|
|
|
|
Primary to Secondary |
|
3,000 |
Vrms |
|
|
|
|
Secondary to Chassis GND |
500 |
Vrms |
|
|
|
|
|
|
|
|
|
|
|
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 |
FlatPAC-EN |
Rev. 1 |
Page 3 of 8 |