Vermont Casting 33XDV, 39XDV, 36XDV User Manual

0 (0)
Vermont Casting 33XDV, 39XDV, 36XDV User Manual

INSTALLER/CONSUMER SAFETY INFORMATION

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

WARNING!

IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas supplier.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from your neighbor’s phone. Follow the gas suppliers instructions.

If you cannot reach your gas supplier call the fire department.

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

Direct Vent Models: 33XDV, 36XDV, 39XDV

Installation Instructions and

Homeowner’s Manual

ESIG

D

N

 

CERTIFIED

C

D

E

 

RTIFIE

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

10009383 12/06 Rev. 10

XDV Direct Vent Gas Fireplace

Table of Contents

PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS

BEFORE USING APPLIANCE.

Thank you and congratulations on your purchase of a CFM Corporation fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation.

Failure to follow these instructions fully may result in a possible fire hazard and will void the warranty.

Installation & Operating Instructions

Important Curing/Burning Instructions

.................................................................................................3

Locating Your Fireplace.......................................................................................................................

3

Fireplace Dimensions..........................................................................................................................

4

Clearance to Combustibles .................................................................................................................

6

Mantels .............................................................................................................................................

6

Hearth .............................................................................................................................................

6

Framing and Finishing.........................................................................................................................

7

Final Finishing .....................................................................................................................................

7

Gas Specifications...............................................................................................................................

7

Gas Inlet and Manifold Pressures .......................................................................................................

7

High Elevations....................................................................................................................................

7

Gas Line Installation............................................................................................................................

7

Remote ON/OFF Switch......................................................................................................................

8

Alternate Switch Location....................................................................................................................

8

EB-1 Electrical Box..............................................................................................................................

8

Electronic Gas Control Valve...............................................................................................................

9

Optional Top Vent Application............................................................................................................

10

Top Vent Application Restrictor Plate.................................................................................................

11

General Venting Information

General Venting.................................................................................................................................

11

General Venting Information-Termination Location ...........................................................................

12

General Information Assembling Vent Pipes .....................................................................................

13

Flex Vent Pipes..................................................................................................................................

13

Twist Lock Pipes................................................................................................................................

14

How to Use the Vent Graph...............................................................................................................

14

Rear Wall Venting Applications & Installation....................................................................................

14

Vertical Sidewall Applications & Installation.......................................................................................

16

Below Grade Installation....................................................................................................................

20

Vertical Through-the-Roof Applications & Installation........................................................................

20

Venting Components .........................................................................................................................

23

Operating Instructions

Glass Information ..............................................................................................................................

24

Louvre Removal ................................................................................................................................

24

Window Frame Assembly Removal...................................................................................................

24

Glass Cleaning ..................................................................................................................................

24

Replacement of Ceramic Hearth Panels ...........................................................................................

24

Installation of Logs and Lava Rock....................................................................................................

25

Flame & Temperature Adjustment .....................................................................................................

30

Manual ON/OFF Valve ......................................................................................................................

30

Flame Characteristics........................................................................................................................

30

Inspecting the Venting System ..........................................................................................................

30

Lighting and Operating Instructions...................................................................................................

32

Instructions for RF Comfort Control Valve.........................................................................................

34

Troubleshooting.................................................................................................................................

38

Fuel Conversion Instructions.............................................................................................................

40

Maintenance

 

Cleaning the Standing Pilot Control System......................................................................................

45

 

 

Replacement Parts ...................................................................................................................................

46

 

 

Optional Accessories

 

 

 

Fan Kits ...........................................................................................................................................

49

 

 

Remote Controls................................................................................................................................

50

 

 

Ceramic Refractory Panels................................................................................................................

50

 

 

Trim Kits, Screen Door Kit, Filigree Louvre Kit ..................................................................................

51

 

 

Warranty .......................................................................................................................................................

55

 

2

Energuide ....................................................................................................................................................

56

10009383

XDV Direct Vent Gas Fireplace

Installation & Operating Instructions

This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1/NFPA 54.

In the Commonwealth of Massachusetts, all gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber.

FOR SAFE INSTALLATION AND OPERATION PLEASE NOTE THE FOLLOWING:

1.This fireplace gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies.

2.Children and adults should be alerted to the hazards of high surface temperatures of this fireplace and should stay away to avoid burns or ignition of clothing.

3.CAUTION: Due to high glass surface temperature children should be carefully supervised when in the same room as fireplace.

4.Under no circumstances should this fireplace be modified. Parts removed for servicing should be replaced prior to operating this fireplace again.

5.Installation and any repairs to this fireplace must be performed by a qualified installer, service agency or gas supplier. A professional service person should be contacted to inspect this fireplace annually. Make it a practice to have all of your gas fireplaces checked annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc.

6.Control compartments, burners and air passages in this fireplace should be kept clean and free of dust and lint. Make sure the gas valve and pilot light are turned off before you attempt to clean this fireplace.

7.The venting system (chimney) of this fireplace should be checked at least once a year and if needed your venting system should be cleaned.

8.Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. This fireplace should not be used as a drying rack for clothing, nor should Christmas stockings or decorations be hung on or around the fireplace.

9.Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this fireplace.

10.The flow of combustion and ventilation air must not be obstructed in any way.

11.When fireplace is installed directly on carpeting, vinyl tile or any combustible material other than wood, the fireplace must be installed on a metal or wood panel extending the full width and depth of the fireplace.

12.This fireplace requires adequate ventilation and combustion air to operate properly.

13.This fireplace must not be connected to a chimney flue serving a separate solid fuel burning fireplace.

14.When the fireplace is not in use it is recommended that the gas valve be left in the OFF position.

WARNING: Check with your electronics manufacturer before installing a television or other electronic device above this fireplace.

10009383

This appliance may be installed in an aftermarket permanently located, manufactured home or mobile home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

IMPORTANT:

PLEASE REVIEW THE FOLLOWING CAREFULLY

Remove any plastic from trim parts before turning the fireplace ON.

It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine.

It is not unusual for your gas fireplace to give off some odor the first time it is burned.This is due to the curing of thepaintandanyundetectedoilfromthemanufacturing process.

Please ensure that your room is well ventilated - open all windows.

It is recommended that you burn your fireplace for at leastten(10)hoursthefirsttimeyouuseit.Iftheoptional fan kit has been installed, place the fan switch in the “OFF” position during this time.

Locating Your Fireplace

Y E A B

C X

D

YB

F

LU584-R

Fig. 1 Locate gas fireplace.

A) Flat on wall

B) Cross corner

C) **Island

D) *Room divider

E) *Flat on wall corner

F) Chase installation

Y) 6” minimum

 

 

NOTE: (fig. 1)

** Island (C) and Room Divider (D) installation is possible as long as the horizontal portion of the vent system (X) does not exceed 20’ (610 cm). See details in Venting Section.

* When you install your fireplace in(D) Room divider or (E) Flat on wall corner positions (Y), a minimum of 6” (153 mm) clearance must be maintained from the perpendicular wall and the front side edge of the fireplace.

Refer to (Y) in Figure 1.

3

XDV Direct Vent Gas Fireplace

XDV Fireplace Dimensions - Installed as Rear Vent

 

 

 

 

Rough

 

 

 

 

Opening

 

 

 

 

Depth

 

 

S

 

X

 

 

 

 

 

 

 

 

F

 

U

 

(16

mm)

S

5/8"

Rough

 

 

Opening

 

 

 

 

 

 

 

 

 

T

 

Height

Low Voltage

Electrical W

Access

B

Gas Line

Access

M

O

P

Fig. 2 Fireplace specifications and framing dimensions.

E

 

 

 

 

4" Dia.(102mm)

 

 

 

 

 

 

7" Dia. (178mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recessed

 

 

 

Nailing

 

 

 

Flange

 

V - Rough Opening Width

5/8" (16mm)

 

 

 

G

 

 

 

Electrical

 

 

 

Access

 

 

 

Low Voltage

 

 

B

Electrical

I

 

D

Access

C

 

Gas Line

 

 

 

 

 

H

 

 

Access

 

 

 

 

 

 

M N

A

 

J

 

 

K

 

 

 

 

 

 

L

 

Ref.

33XDV

36XDV

39 XDV

A

33”

(838 mm)

36”

(914 mm)

39”

(991 mm)

B

28 ⁄ ”

(733 mm)

34¹⁄ ”

(870 mm)

34¹⁄ ”

(870 mm)

C

31¹⁄ ”

(794 mm)

34¹⁄ ”

(870 mm)

37¹⁄ ”

(946 mm)

D

18³⁄ ”

(466 mm)

23”

(584 mm)

23”

(584 mm)

E

22³⁄ ”

(578 mm)

24”

(610 mm)

27”

(686 mm)

F

14³⁄ ”

(365 mm)

16¹⁄ ”

(413 mm)

16¹⁄ ”

(413 mm)

G

16³⁄ ”

(426 mm)

18³⁄ ”

(476 mm)

18³⁄ ”

(476 mm)

H

19³⁄ ”

(487 mm)

24¹⁄ ”

(616 mm)

24¹⁄ ”

(616 mm)

I

22¹¹⁄ ”

(576 mm)

28¹⁄ ”

(714 mm)

28¹⁄ ”

(714 mm)

J

4 ⁄ ”

(118 mm)

5 ⁄ ”

(143 mm)

5 ⁄ ”

(143 mm)

K

6³⁄ ”

(160 mm)

8”

(203 mm)

8”

(203 mm)

L

8 ⁄ ”

(225 mm)

11 ⁄ ”

(302 mm)

11 ⁄ ”

(302 mm)

M

2”

(51 mm)

2”

(51 mm)

2”

(51 mm)

N

3³⁄ ”

(85 mm)

3¹⁄ ”

(82 mm)

3¹⁄ ”

(82 mm)

O

4 ⁄ ”

(118 mm)

6³⁄ ”

(171 mm)

6³⁄ ”

(171 mm)

P

6³⁄ ”

(162 mm)

9¹⁄ ”

(235 mm)

9¹⁄ ”

(235 mm)

 

 

 

Framing Dimensions

 

 

S

36”

(914 mm)

41 ⁄ ”

(1057 mm)

44”

(1118 mm)

T

51”

(1295 mm)

58 ⁄ ”

(1495 mm)

62¹⁄ ”

(1581 mm)

U

25¹⁄ ”

(641 mm)

29 ⁄ ”

(748 mm)

31¹⁄ ”

(790 mm)

V

33¹⁄ ”

(851 mm)

36¹⁄ ”

(927 mm)

39¹⁄ ”

(1003 mm)

W

31”

(787 mm)

38 ⁄ ”

(980 mm)

38 ⁄ ”

(980 mm)

X

14 ⁄ ”

(378 mm)

16³⁄ ”

(426 mm)

16³⁄ ”

(426 mm)

4

10009383

XDV Direct Vent Gas Fireplace

XDV Fireplace Dimensions - Installed as Top Vent

S

 

 

 

 

 

Rough

E

7" Dia. (178mm)

 

 

 

 

 

4" Dia. (102mm)

 

 

 

 

 

Opening

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

 

 

 

S

 

 

 

 

R

 

 

 

 

 

X

 

 

 

 

 

 

 

 

Recessed

 

 

 

 

 

F

 

 

 

 

 

 

 

Nailing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flange

 

 

 

 

mm)

 

V - Rough Opening Width

5/8" (16mm)

 

 

 

(16

 

 

 

U

 

5/8"

 

Rough

 

 

 

 

 

 

 

 

 

 

 

Opening

 

 

 

 

 

 

 

 

 

THeight

 

Low Voltage

 

 

 

Electrical

 

 

 

 

 

Access

 

Q

Electrical

 

W

 

Low Voltage

 

Access

 

B

 

 

 

 

Electrical

 

 

 

 

 

 

 

B

 

 

D

Access

 

 

Gas Line

 

C

Gas Line

 

 

 

 

 

 

Access

 

 

 

Access

 

 

 

 

 

 

 

N

 

O

M

A

 

J

M

 

P

 

K

 

 

 

 

 

 

 

 

 

L

 

Fig. 3 Fireplace specifications and framing dimensions.

Ref.

33XDV

36XDV

39XDV

A

33”

(838 mm)

36”

(914 mm)

39”

(991 mm)

B

28 ⁄ ”

(733 mm)

34¹⁄ ”

(870 mm)

34¹⁄ ”

(870 mm)

C

31¹⁄ ”

(794 mm)

34¹⁄ ”

(870 mm)

37¹⁄ ”

(946 mm)

D

18³⁄ ”

(466 mm)

23”

(584 mm)

23”

(584 mm)

E

22³⁄ ”

(578 mm)

24”

(610 mm)

27”

(686 mm)

F

14³⁄ ”

(365 mm)

16¹⁄ ”

(413 mm)

16¹⁄ ”

(413 mm)

G

--

--

--

--

--

--

H

--

--

--

--

--

--

I

--

--

--

--

--

--

J

4 ⁄ ”

(118 mm)

5 ⁄ ”

(143 mm)

5 ⁄ ”

(143 mm)

K

6³⁄ ”

(162 mm)

8”

(203 mm)

8”

(203 mm)

L

8 ⁄ ”

(225 mm)

11 ⁄ ”

(302 mm)

11 ⁄ ”

(302 mm)

M

2”

(51 mm)

2”

(51 mm)

2”

(51 mm)

N

3³⁄ ”

(85 mm)

3¹⁄ ”

(82 mm)

3¹⁄ ”

(82 mm)

O

4 ⁄ ”

(117 mm)

6³⁄ ”

(171 mm)

6³⁄ ”

(171 mm)

P

6³⁄ ”

(162 mm)

9¹⁄ ”

(235 mm)

9¹⁄ ”

(235 mm)

Q

31³⁄ ”

(806 mm)

37”

(939 mm)

37”

(939 mm)

R

6 ⁄ ”

(156 mm)

6³⁄ ”

(170 mm)

6³⁄ ”

(170 mm)

 

 

 

Framing Dimensions

 

 

S

36”

(914 mm)

39³⁄ ”

(1010 mm)

43¹⁄ ”

(1045 mm)

T

51”

(1295 mm)

55¹⁄ ”

(1403 mm)

60 ⁄ ”

(1546 mm)

U

25¹⁄ ”

(641 mm)

28¹⁄ ”

(714 mm)

30 ⁄ ”

(784 mm)

V

33¹⁄ ”

(851 mm)

36¹⁄ ”

(927 mm)

39¹⁄ ”

(1003 mm)

W

31”

(787 mm)

38 ⁄ ”

(980 mm)

38 ⁄ ”

(980 mm)

X

14 ⁄ ”

(378 mm)

16³⁄ ”

(426 mm)

16³⁄ ”

(426 mm)

 

 

 

 

 

 

 

10009383

5

XDV Direct Vent Gas Fireplace

Clearance to Combustibles

Top of Unit to Ceiling ................................

36” (914 mm)

Front of Unit to Combustibles...................

36” (914 mm)

Appliance

 

Top of Standoff.........................................

0” (0 mm)

Bottom......................................................

0” (0 mm)

Side..........................................................

0” (0 mm)

Back.........................................................

0” (0 mm)

Venting

 

Concentric sections of DV Vent....................

1” (25 mm)

Nonconcentric sections of DV Vent

 

Sides and Bottom...................................

1” (25 mm)

Top .........................................................

2” (51 mm)

Mantels

The height that a combustible mantel is fitted above the fireplace is dependent on the depth of the mantel. This also applies to the distance between the mantel leg (if fitted) and the fireplace.

For the correct mounting height and widths refer to Figs. 4a and 4b, and the following Mantel Charts.

The fitting of a bay window trim kit does not effect the distances and reference points referred to in the diagram and chart.

Noncombustible mantels and legs may be installed at any height and width around the appliance. When

using paint or lacquer to finish the mantel, such paint or lacquer must be heat resistant to prevent discoloration.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

Mantel Shelf

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ref.

or Breastplate

 

 

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

 

 

 

 

 

V

10”

(254 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

8”

(203 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

X

6”

(152 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Z

 

 

 

 

 

Y

4”

(101 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Z

2”

(51 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintain minimum 3/4”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(19 mm) clearance to

 

 

 

 

A

B

C

D

E

 

 

 

 

combustible

 

 

 

 

 

 

 

 

 

 

Fireplace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Louvre Assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of Combustion

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chamber

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM146

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mantel Chart

 

 

 

 

Ref.

 

 

 

Mantel from Top of Combustion Chamber

 

 

 

 

33XDV

 

 

 

 

36XDV

39XDV

 

A

 

18¹⁄ ” (470 mm)

 

19”

 

(482 mm)

20”

(508 mm)

B

 

16¹⁄ ” (419 mm)

 

17”

 

(432 mm)

18”

(457 mm)

 

C

 

14¹⁄ ” (368 mm)

 

15”

 

(381 mm)

16”

(406 mm)

 

D

 

12¹⁄ ” (318 mm)

 

13”

 

(330 mm)

14”

(355 mm)

 

E

 

10¹⁄ ” (267 mm)

 

11”

 

(279 mm)

12”

(305 mm

 

Fig. 4a

Combustible mantel minimum installation.

 

 

 

Black

 

J I H

 

G

Surround

 

 

F

Face

 

Mantel

 

 

 

CFM164a

Leg

 

 

 

K

Side of

 

L

 

M

Combustion Chamber

N

 

 

O

 

 

 

 

 

 

 

 

CFM170

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mantel

 

Mantel Leg FromSide

Ref.

Leg Depth

Ref.

of Comb. Opening

F

10”

(254 mm)

K

11¹⁄ ”

(292 mm)

G

8”

(203 mm)

L

9¹⁄ ”

(241 mm)

H

6”

(152 mm)

M

7¹⁄ ”

(191 mm)

I

4”

(101 mm)

N

5¹⁄ ”

(140 mm)

J

2”

(51 mm)

O

3¹⁄ ”

(89 mm)

 

 

 

 

 

 

 

 

 

 

Fig. 4b

Combustible mantel leg minimum installation.

Hearth

A hearth is not mandatory but is recommended for aesthetic purposes. We recommend a noncombustible hearth which projects out 12” (305 mm) or more from the front of the fireplace.

Cold climate installation recommendation:

When installing this unit against a non-insulated exterior wall or chase, it is mandatory that the outer walls be insulated to conform to applicable insulation codes.

Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.

California Health & Safety Code Sec. 25249.6

6

10009383

Framing and Finishing

Check fireplace to make sure it is levelled and properly positioned.

To mount the appliance:

1.Choose the location.

2.This unit comes with four (4) flanges pre-mounted on both sides of the fireplace to allow two different drywall thicknesses to be used. Flange “A” is for 1/2” drywall while flange “B” is for 5/8” drywall.

3.Bend the desired flanges out 90° on both sides of the fireplace. Slide the fireplace into the framed opening until the flanges contact the front surfaces of the framing. Level the unit and secure it firmly in place.

Flange

Drywall

Flange Location for

Position

Depth

Desired Drywall Depth

A

1/2” / 13 mm

 

B

5/8” / 16 mm

 

AB

FP1539

Fig. 5 Nailing flanges.

Final Finishing

Noncombustible materials such as brick or tile may be extended over the edges of the face of the fireplace. DO NOT cover any vent or grille panels.

If a Trim Kit is going to be installed on the fireplace, the brick or tile will have to be installed flush with the edges of the fireplace.

33XDV / 36XDV / 39XDV Certified To

ANSI Z21.88-2005 / CSA 2.33-2005

Vented Gas Fireplace Heaters

Units: GFDN3L1, GFDE3L1, GFDN3J1, GFDI3J1,

GFDE3JI, GFDN3K1, GFDE3K1

XDV Direct Vent Gas Fireplace

Gas Specifications

 

 

 

Max.

Min.

 

 

 

Input

Input

 

 

 

Model

Fuel

Gas Control

BTU/h

BTU/h

33XDVRN

Nat.

Millivolt Hi/Lo

21,500

4,400

33XDVRP

Prop.

Millivolt Hi/Lo

21,500

5,425

33XDVEN

Nat.

24 Volt Hi/Lo

21,500

4,400

33XDVEP

Prop.

24 Volt Hi/Lo

21,500

5,425

36XDVRN

Nat.

Millivolt Hi/Lo

27,500

5,150

36XDVRP

Prop.

Millivolt Hi/Lo

27,500

5,500

36XDVRFN

Nat.

Comfort Contrl

27,500

5,810

36XDVRFP

Prop.

Comfort Contrl

27,500

6,225

36XDVEN

Nat.

24 Volt Hi/Lo

27,500

5,150

36XDVEP

Prop.

24 Volt Hi/Lo

27,500

5,500

39XDVRN

Nat.

Millivolt Hi/Lo

30,000

6,700

39XDVRP

Prop.

Millivolt Hi/Lo

30,000

5,800

39XDVEN

Nat

24 Volt Hi/Lo

30,000

6,700

39XDVEP

Prop

24 Volt Hi/Lo

30,000

5,800

Gas Inlet and Manifold Pressures

 

 

Natural

LP (Propane)

Inlet Minimum

5.5” w.c.

11.0” w.c.

Inlet Maximum

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

 

 

 

 

High Elevations

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level.

For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m).

Gas Line Installation

When purging the gas lines, the front window frame assembly must be removed.

The gas pipeline can be brought in through the rear of the appliance as well as the bottom. Knockouts are

provided on the bottom behind the valve to allow for the gas pipe installation and testing of any gas connection. It is most convenient to bring the gas line in from the rear right side of the valve as this allows fan installation or removal without disconnecting the gas line.

10009383

7

XDV Direct Vent Gas Fireplace

The gas line connection can be made with properly tinned 3/8” copper tubing, 3/8” rigid pipe or an approved flex connector. Since some municipalities have additional local codes, it is always best to consult your local authority and the National Fuel Gas Code, ANSI Z223.1/NFPA 54 in the USA or the CSA-B149.1 installation code.

1/2” Gas Supply

1/2” NPT x 1/2” Flare Shutoff Valve

3/8” Flex Line

(From Valve)

FP297A

Fig. 6 Typical gas supply installation.

Always check for gas leaks with a mild soap and water solution applied with a brush no larger than 1” (25 mm). Never

apply soap and water solution with a spray bottle. Do not use an open flame for leak testing.

The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi.

Isolate or disconnect this or any other gas appliance control form the gas line when pressure testing.

The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to provide a 1/8” test point up stream of the control.

When using copper or flex connector use only approved fittings. Always provide a union when using black iron pipe so the gas line can be easily disconnected for burner or fan servicing. See gas specification for pressure details and ratings.

The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi. Isolate or disconnect this and any other gas appliance control from the gas line when pressure testing.

Remote ON/OFF Switch

Do not wire the remote ON/OFF wall switch for this gas appliance into a 120v power supply.

1.Thread wire through the electrical knockout located on either side of the unit. Take care not to cut the wire or insulation on metal edges. Ensure the wire is secured and protected form possible damage. Run one end of the gas control valve and the other end to the conveniently located wall switch.

2.Attach the wire to the ON/OFF switch and install switch into receptacle box. Attach cover plate to switch.

3.Connect wiring to gas valve. (Fig. 7)

Remote ON/OFF Switch

TH TP TPTH

FP1218

Fig. 7 Remote switch wiring diagram for R models.

Alternate Switch Location

The remote switch can be installed on the front/side of the access door. Simply mount the switch to the bracket provided and screw the bracket to either side of the frame, lining up the screws with the pre-punched holes. (Fig. 8)

FP1024

Fig. 8 Alternate switch location.

EB-1 Electrical Box

The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code.

For USA installations follow local codes and the national electrical code ANSI/ NFPA No. 70.

It is strongly suggested that the wiring of the EB-1 Electrical Junction Box be carried out by a licensed electrician.

Ensure that the power to the supply line has been disconnected before commencing this procedure.

8

10009383

The EB-1 Electrical junction box has been fitted standard on this model to allow for the easy connection of an optional fan kit.

To connect the EB-1 box to the house electrical supply follow the steps below.

1.Unscrew the retaining screw from the EB-1 base plate and remove the EB-1 assembly from the appliance. (Fig. 9)

2.Remove the front cover of the EB-1 box.

3.Remove the plug socket assembly from the EB-1 box.

4.Feed the supply line in through the EB-1 opening in the side of the appliance and then through the back of the EB-1 assembly. (Fig. 9)

5.Connect the black wire of the power supply line to the brass screw (polarized) of the socket assembly.

6.Connect the white wire of the power line to the chrome screw of the socket assembly.

7.Connect the ground wire of the supply line to the green screw of the socket assembly.

8.Refit the socket assembly back into the electrical box and replace the cover plate. Secure the cable with the clamp on the outside of the EB-1 base plate and refit the EB-1 assembly to the unit with the screw removed in step 1.

XDV Direct Vent Gas Fireplace

INSIDE

Electrical Box

FRONTOFUNIT

OUTSIDE

 

OF

UNIT

FRONT

FP580

 

 

 

Fig. 9 EB-1 receptacle.

Electronic Gas Control Valve

This appliance may be fitted with a Synetek ignition module.

Installation of the remote on/off starter switch or wall thermostat on electronic ignition units.

1.Thread the wiring through the holes on the side panels of the appliance. Take care not to cut the wire or insulation on metal edges. Route the wire to a conveniently located receptacle box.

2.Attach the wire to the ON/OFF switch and install the

switch into the receptacle box.

 

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHITE

 

 

L2

 

 

POWER CORD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GREEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PURPLE

 

 

 

 

 

PILOTSENSING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PILOTIGNITER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YELLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

 

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VALVE

 

 

CIRCUITBOARD

BLUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

ON/OFF SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHITE

 

 

 

 

 

 

OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WALL THERMOSTAT

 

FP1571

Fig. 10 SIT822 Valve with Synetek electronic control wiring diagram.

10009383

9

XDV Direct Vent Gas Fireplace

3.Connect the white wire from the wall switch or wall thermostat to the white wire terminal from the electronic module. Connect the black wire from the wall switch or the red wire from the wall thermostat, to the red wire terminal from the electronic module.

Optional Top Vent Application

The 33/36/39XDV fireplaces are shipped as rear vent units. If the layout requires a top vent, convert the unit following the steps below.

1.Remove the 10 screws securing outer collar adapter to fireplace. (Fig. 11)

2.Set outer collar adapter aside.

3.Carefully remove and discard the insulation directly below the 7” hole in the cabinet top. The insulation is perforated around the hole to aid in its removal. Remove the four (4) screws securing flue cover to top of unit and remove flue cover. (Fig. 12)

4.Remove the four (4) screws securing the flue pipe assembly to the appliance. Remove flue pipe. (Fig. 12)

5.Secure flue cover to back of flue outlet. (Fig. 13)

6.Install flue pipe and gasket removed in step 4 to top of unit with four (4) screws. (Fig. 13)

7.Secure outer collar adapter to unit with the round collar on top, secure with 10 screws. (Fig. 14)

NOTE: Be sure not to damage any gasket material.

Outer Collar

Adapter

Remove Screws

(5)

Flue Pipe

Remove

 

Screws (5)

FP1458

Fig. 11 Remove screws from outer collar adapter.

Remove Insulation 7”

 

Diameter Notch Out

Remove Screws (4)

 

Flue Cover

Remove Screws (4)

FP1549

 

Fig. 12 Remove flue cover and flue pipe.

Flue Pipe

Install Screws (4)

Back in Place

Flue

Cover

Install Screws (4)

FP1551

Back in Place

 

Fig. 13 Replace flue cover and flue pipe.

Install Screws (5)

Back in Place

Outer Collar Adapter

Install Screws (5)

 

Back in Place

FP1550

 

Fig. 14 Completed conversion.

After conversion to top vent configuration, the 4” (102 mm) flue pipe should be concentric within the 7” (175 mm) outer collar.

10

10009383

Top Vent Application

Restrictor Plate

When the 33XDV or 36XDV models are installed as top vent fireplaces with a minimum 12” (305 mm) rise, the restrictor plate must be installed to give better flame appearance.

This restrictor plate is shipped with the 33/36XDV and is located below the access control panel.

33XDV Restrictor Plate Installation

1.Remove rear log bracket located behind the burner panel.

2.Install the restrictor plate with the rear log using existing mounting holes and pre-attached screws from the rear log bracket. (Fig. 15)

3.Install rear log bracket assembly by reversing Step 1.

4.Install log set, ember materials, lava rock. Refer to log set installation section.

36XDV Restrictor Plate Installation

1.Remover rear log bracket located behind the burner panel.

2.Replace the deflector rear log bracket with the restrictor plate to the rear log bracket using existing mounting holes and screws. (Fig. 16) Discard deflector.

3.Install rear log bracket assembly by reversing Step 1.

4.Install log set, ember materials, lava rock. Refer to log set installation section.

XDV Direct Vent Gas Fireplace

Rear Log Bracket

Restrictor Plate

FP1729

Fig. 15 33XDV restrictor plate installation.

Rear Log Bracket

Remove

and Discard

Deflector

Restrictor Plate

FP1730

 

Fig. 16 36XDV restrictor plate installation.

General Venting

Your fireplace is approved to be vented either through the side wall, or vertically through the roof.

Only CFM Corporation venting components specifically approved and labelled for this fireplace may be used.

If vent termination is installed in an accessible location, Vent Termination Guard #53525 shall be installed.

Vent terminations shall not be recessed into a wall or siding.

Horizontal venting which incorporates the twist lock pipe must be installed on a level plane without an inclining or declining slope.

Horizontal venting which incorporates the use of flex venting shall have an inclining slope from the unit of 1/2” (13 mm) per 12” (305 mm).

There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24” (610 mm) from the front of the termination hood.

Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termination area after snow falls, and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

Location of Vent Termination

It is imperative the vent termination be located observing the minimum clearances as shown on the next page.

*Check with local codes or in absence of same with CSA B149.1 Installation Codes (1991) for Canada or follow the current National Fuel Gas Code, ANSI Z223.1/NFPA 54 for installations in the USA.

10009383

11

XDV Direct Vent Gas Fireplace

General Venting Information - Termination Location

D

V

E

L

V

B

INSIDE

CORNER DETAIL

G

 

V

 

N

A

H

N

 

 

 

V

C

B

 

 

 

 

 

 

 

 

 

 

ClosedFixed

V

 

B

 

V

 

 

 

 

 

 

 

Operable

Operable

Fixed

 

 

 

 

 

 

G

F

V

 

Closed

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

V

 

 

B

B

V

J

X

M

 

 

 

G

 

 

 

 

 

X

 

 

 

 

A

 

 

 

I

V

K

V

 

 

 

 

 

 

 

 

 

 

 

 

A

V VENT TERMINATION X AIR SUPPLY INLET

AREA WHERE TERMINAL IS NOT PERMITTED

CFM145a

 

 

 

Canadian Installations1

US Installations2

 

A =

Clearance above grade, veranda, porch,

12” (30cm)

12” (30cm)

 

 

deck, or balcony

 

 

 

B = Clearance to window or door that may be

6” (15cm) for appliances

6” (15cm) for appliances

 

 

opened

< 10,000Btuh (3kW), 12” (30cm)

< 10,000 Btuh (3kW), 9”

 

 

 

for appliances > 10,000 Btuh (3kW) and

(23cm) for appliances > 10,000

 

 

 

< 100,000 Btuh (30kW), 36” (91cm)

Btuh (3kW) and < 50,000 Btuh

 

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30cm) for

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

C = Clearance to permanently closed window

12” (305mm) recommended to

12” (305mm) recommended to

 

 

 

prevent window condensation

prevent window condensation

 

D = Vertical clearance to ventilated soffit located

 

 

 

 

above the terminal within a horizontal

18” (458mm)

18” (458mm)

 

 

distance of 2’ (610mm) from the center

 

 

 

 

line of the terminal

 

 

 

E = Clearance to unventilated soffit

12” (305mm)

12” (305mm)

 

F =

Clearance to outside corner

see next page

see next page

 

G = Clearance to inside corner (see next page)

see next page

see next page

 

H = Clearance to each inside of center line

3’ (91cm) within a height of 15’ (5m)

3’ (91cm) within a height of 15’

 

 

extended above meter/regulator assembly

above the meter/regulator assembly

(5m) above the meter/regulator

 

 

 

 

assy

 

I =

Clearance to service regulator vent outlet

3’ (91cm)

3’ (91cm)

 

J =

Clearance to nonmechanical air supply inlet

6” (15cm) for appliances < 10,000

6” (15cm) for appliances

 

 

to building or the combustion air inlet to any

Btuh (3kW), 12” (30cm) for

< 10,000 Btuh (3kW), 9”

 

 

other appliances

appliances > 10,000 Btuh (3kW) and

(23cm) for appliances > 10,000

 

 

 

< 100,000 Btuh (30kW), 36” (91cm)

Btuh (3kW) and < 50,000 Btuh

 

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30cm) for

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

K = Clearance to a mechanical air supply inlet

6’ (1.83m)

3’ (91cm) above if within 10

 

 

 

 

feet (3m) horizontally

 

L =

Clearance above paved sidewalk or paved

7’ (2.13m)†

7’ (2.13m)†

 

 

driveway located on public property

 

 

 

M = Clearance under veranda, porch, deck or

12” (30cm)‡

12” (30cm)‡

 

 

balcony

 

 

N = Clearance above a roof shall extend a minimum of 24” (610mm) above the highest point when it passes through the roof surface, and any other obstruction within a horizontal distance of 18” (450mm).

1 In accordance with the current CSA-B149 Installation Codes

2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes

† A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings

‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: NOTE: 1. Local codes or regulations may require different clearances.

2.The special venting system used on Direct Vent Fireplaces are certified as part of the appliance, with clearances tested and approved by the listing agency.

3.CFM Corporation assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

Fig. 17

Vent termination locations.

12

10009383

XDV Direct Vent Gas Fireplace

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.

Inside Corner Outside Corner Alcove Applications*

 

 

 

 

C

D

 

 

 

 

C

 

 

 

 

F =

 

 

 

G =

 

Combustible

 

G

 

Combustible

 

6" (152 mm)

V

 

 

6" (152 mm)

V

Noncombustible

E

 

 

 

2" (51 mm)

 

 

Noncombustible

 

O

 

V

 

F

 

2" (51 mm)

 

 

 

 

 

Balcony -

Balcony -

 

 

 

 

with no side wall

with perpendicular side wall

E = Min. 6” (152 mm) for

 

 

 

 

 

 

non-vinyl sidewalls

 

 

 

 

Min. 12” (305 mm) for

 

 

 

vinyl sidewalls

 

 

 

 

O = 8’ (2.4 m) Min.

 

 

M

M

No.

 

 

 

V

V

of Caps

DMin.

CMax.

 

1

3’ (.9 mm)

2 x DActual

 

 

P

 

 

2

6’ (1.8 m)

1 x DActual

 

M =

Combustible &

3

9’ (2.7 m)

2/3 x DActual

 

Noncombustible

4

12’ (3.7 m)

1/2 x DActual

 

Combustible &

 

M = 24" (610 mm)

 

Noncombustible

DMin. = # of Termination caps x 3

 

P = 20” (508 mm)

 

12" (305 mm)

 

 

CMax. = (2 / # termination caps) x DActual

584-15

 

 

*NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All mechanical air intakes within 10’ (1 m) of a termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap.

Fig. 17a Termination clearances.

General Information Assembling Vent Pipes

Canadian Installations:

Venting system must be installed in accordance with the current CSA-B149.1 installation code.

USA Installations:

The venting system must conform with local codes and/ or the current National Fuel Gas code ANSI Z223.1/ NFPA 54.

Only venting components manufactured by CFM Corporation can be used in Direct Vent systems.

Flex Vent Pipes

Before joining the flex vent pipe to the unit, apply a bead of high temperature sealant* (provided) to the 4” pipe exiting the fireplace. Secure flex vent piep in place with a hose clamp (provided).

*Be sure the flex pipe overlaps at least 1” (25 mm) onto the collars of the fireplace and termination. If the termination has an internal bead, be sure to overlap and secure 1” (25 mm) past the bead.

* Be sure the flex vent is flat and flush with the flue or outer collar before proceeding. Apply a tug to be sure the vent will not slip off the collars.

Repeat process with 7” flex vent pipe. The same procedure must be performed on the vent side.

Apply High Temperature

Sealant

Hose Clamp

FP1471

Fig. 18 Apply high temperature sealant to 4” and 7” pipes.

10009383

13

XDV Direct Vent Gas Fireplace

Twist Lock Pipes

When using CFM Corporation twist-lock pipe it is not necessary to use sealant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the sliding joints of any telescopic vent section used in the system.

To join the twist lock pipes together, simply align the beads of the male end with the grooves of the female end, then while bringing the pipe together, twist the pipe until the flange on the female end contacts the external flange on the male end. It is recommended that you secure the joints with three (3) sheet metal screws, however this is not mandatory with twist lock pipe.

To make it easier to assemble the joints we suggest putting a lubricant (Vaseline or similar) on the male end of the twist lock pipe prior to assembly.

Male End

Female End

Screw Holes

TWL100

Fig. 19 Twist-lock pipe joints.

How to Use the Vent Graph

The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system.

1.Determine the height of the center of the horizontal vent pipe exiting through the outer wall. Using this dimension on the Sidewall Vent Graph (Fig. 20) locate the point intersecting with slanted graph line.

2.From the point of this intersection, draw a vertical line to the bottom of the graph.

3.Select the indicated dimension, and position the fireplace in accordance with same.

Example A:

If the vertical dimension from the floor of the fireplace is 11’ (3.4 m) the horizontal run to the face of the outer wall must not exceed 14’ (4.3 m).

Example B:

If the vertical dimension from the floor of the unit is 7’ (2.14 m), the horizontal run to the face of the outer wall must not exceed 8¹⁄’ (2.6 m).

30

 

 

29

 

 

28

 

 

27

 

 

26

 

 

25

 

 

24

theto

Vertical

23

 

 

22

 

 

21

pipeventhorizontalthe of center

unittheoffloorthefrom dimension

7

20

 

 

19

 

 

18

 

 

17

 

 

16

 

 

15

 

 

14

 

 

13

 

 

12

eg: A

 

11

 

 

10

 

 

9

8

6

eg: B

 

5

 

4

 

3

 

34 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Horizontal dimension from the outside face of the wall to the center of the fireplace vent flange

Sidewall vent graph showing the relationship between vertical and horizontal dimensions for a Direct Vent flue system.

Fig. 20 Sidewall venting graph. (Dimensions in feet)

Rear Wall Venting Applications

When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance.

Only CFM Corporation venting components are approved to be used in these applications. (Refer to “Venting Components” listed for different installation requirements)

The maximum horizontal distance between the rear of the appliance (or end of the transition elbow in a corner application) and the outside face of the rear wall is 20” (508 mm). (Fig. 21)

Only one 45° elbow is allowed in these installations.

Minimum clearances between vent pipe and combustible materials are as follows:

Top - 2” (51 mm)

Sides - 1” (25 mm)

Bottom - 1” (25 mm)

14

10009383

Rear Vent Top View

20" (508 mm)

 

DVR584-600

Fig. 21 Rear vent application, no elbows.

20"

20"

(508 mm)

(508 mm)

Max.

Max.

45°

45°

REAR VENT-TOP VIEW

FP836

Fig. 22 Rear vent application, one 45° elbow.

Rear Wall Installation

Twist Lock Pipe

STEP 1

Locate vent opening on the wall. To locate hole center consult with appropriate fireplace dimensions, Page 4. Frame as shown below.

NOTE: When using flex vent, the opening will have to be measured according to the 1/2” (13 mm) rise in 12” (305 mm) vertical run.

Combustible Walls (Fig. 23): Cut a 10³⁄ ”H x 9³⁄ ” W (264 x 240 mm) hole through the exterior wall and frame as shown.

Noncombustible Walls (Fig. 23): Hole opening must be 7¹⁄ ” (190 mm) in diameter.

Zero clearance sleeve is only required for combustible walls.

STEP 2

Measure wall thickness and cut zero clearance sleeve parts to proper length (MAXIMUM 12”/305 mm). Assemble sleeve and attach to firestop with #8 sheet metal screws (supplied). (Fig. 24)

STEP 3

Measure the horizontal length requirement for the venting including a 2” (51 mm) overlap, i.e. from the elbow to the outside wall face plus 2” (51 mm). (Fig. 22)

XDV Direct Vent Gas Fireplace

Vent Opening for Combustible Wall

9³⁄ ”

(240mm)

Framing 10³⁄ ” Detail

(264mm)

Fireplace Hearth

Opening for Noncombustible Wall

7¹⁄ ”

 

(190 mm)

 

 

VO584-100

Fig. 23 Locate vent opening on wall.

 

Adjustable

Max. Length

Zero Clearance

12” (305mm)

 

Sleeve

 

 

#8 Screws (2)

#8 Screws

 

(2)

#8

 

Screws

 

(2)

Firestop

 

Adjustable Zero Clearance Sleeve

ZCS101

Fig. 24 Adjustable zero clearance sleeve.

 

STEP 4

Install the 4” (102 mm) vent to the appliance collar and secure with three (3) sheet metal screws. Install the 7” (178 mm) vent pipe tot he appliance collar and secure with three (3) sheet metal screws. It is not necessary to seal this connection. If a 45° elbow is being used, attach the elbow to the appliance in the same manner then attach the venting to the elbow.

It is critical there is no downward slope away from the appliance when connecting

the vent or elbow.

STEP 5

Guide the venting through the vent hole a you place the appliance in its installed position. Guide the 4” (102 mm) and 7” (178 mm) collar of the vent termination into the outer ends of the venting. Do not force the termination. If the vent pipes do not align with the termination, remove and realign the venting at the appliance flue collars. (Fig. 25) Attach the termination to the wall as outlined in the instruction sheet supplied with the termination.

10009383

15

XDV Direct Vent Gas Fireplace

Finished Wall

Vent

Termination

FP1005

Fig. 25 Side view of final unit location.

Rear Wall Vent Installations -

Flex Vent Pipe

Follow Steps 1 and 2 on Page 15.

Step 3

Install the 4” (102 mm) flex vent pipe to the appliance collars described in “General Information Assembling Vent Pipes”, Page 11. If the installation requires a 45° angle, grasp the vent pipe close to the appliance collar and bend to 45°. DO NOT exceed 45°. (Fig. 26)

Install the 7” vent pipe in the same manner as Step 2.

Termination

Flex Section

Appliance Collars

FP1473

Fig. 26 Grasp the vent pipe close to the collar and bend to 45° angle. Do not exceed 45°.

NOTE: There must be a 1/2” (13 mm) rise in a 12” (305 mm) length of flex vent.

Step 4

Assemble the flex vent to the collars on the termination as you did on the appliance.

Rise

FP1472

Fig. 27 There must be a 1/2” rise per foot length.

Vertical Sidewall Applications

Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to.

The Vent Graph shows the relationship between vertical and horizontal side wall venting and will help to determine the various dimensions allowable.

Minimum clearance between vent pipes and combustible materials is 1”(25 mm) on top, bottom and sides unless otherwise noted.

When vent termination exits through foundations less than 20” below siding outcrop, the vent pipe must flush up with the siding. It is always best to locate the fireplace in such a way that minimizes the number of offsets and horizontal vent length.

The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace to the face of the outer wall.

Horizontal plane means no vertical rise exists on this portion of the vent assembly.

When installing the appliance as a rear vent unit, the 90° or 45° transition elbow attached directly to the rear of the unit is NOT INCLUDED in the following criteria and calculations, and unless specifically mentioned should be ignored when calculating venting layouts.

16

10009383

The maximum number of 90° elbows per side wall installation is three (3). (Fig. 28)

If a 90° elbow is fitted directly on top of the fireplace flange, the maximum horizontal vent run before the termination or a vertical rise is 36” (914 mm). (Fig. 29)

3 x 90°

3 x 90°

Elbows

Elbows

FP1176

Fig. 28 Maximum three (3) 90° elbows per installation.

36" (914 mm) Max.

36" (914 mm) Max.

FP1177

Fig. 29 Maximum horizontal run with no rise.

If a 90° elbow is used in the horizontal vent run (level height maintained) the maximum horizontal vent length is reduced by 36” (914 mm). (Fig. 29) This does not apply if the 90° elbows are used to increase or redirect a vertical rise. (Fig. 30, 31)

Example: According to the vent graph (Page 15) the maximum horizontal vent length in a system with a 7.5’ (2.3 m) vertical rise is 20’ (6 m) and if a 90° elbow is required in the horizontal vent it must be reduced to 17’ (5.2 m). In Figure 31 Dimension A plus B must not be greater than 17’ (5.2 m).

A B

A + B = 17' (Max.) (5.2m)

7'6"

(2.3m)

FP1178

Fig. 30 Horizontal run reduction.

XDV Direct Vent Gas Fireplace

B 7’ (178 cm)

A 10’ (254 cm)

A + B = 17’ 8’ (518 cm) Max.

(244 cm)

V584-201

Fig. 31 Maximum vent run with elbows.

In Figure 30 & 31, dimension A plus B must not be greater than 17’ (5.2 m).

The maximum number of 45° elbows permitted per side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run.

For each 45° elbow installed in the horizontal run, the length of the horizontal run MUST be reduced by 18” (45 cm). This does not apply if the 45° elbows are installed on the vertical part of the vent system.

The maximum number of elbow degrees in a system is 270°. (Fig. 32)

Example:

Elbow 1 = 90°

Elbow 2 = 45°

Elbow 3 = 45°

Elbow 4 = 90°

Total angular variation = 270°

1 + 2 + 3 + 4 = 270°

1

1

 

2

2

 

3

3

 

4

4

 

FP1180

Fig. 32 Maximum elbow usage.

10009383

17