Utica Boilers SSC User Manual

Loading...

USER'S

INFORMATION

MANUAL

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas

supplier.

Information and specifications outlined in this manual in effect at the

 

time of printing of this manual. Manufacturer reserves the right to

 

discontinue, change specifications or system design at any time without

 

notice and without incurring any obligation, whatsoever.

P/N 240008984, Rev. D [06/2013]

1 - GENERAL

1.1 General

This boiler has few user serviceable parts. Maintenance and Service must be completed by qualified agency.

1.3 What To Do Should Overheating Occur

Do not turn off or disconnect electrical supply to boiler and pumps. Shut off gas supply at location external to appliance.

! WARNING

Fire, explosion, asphyxiation and electrical shock hazard. Improper maintenance and service could result in death or serious injury. Read this manual and understand all requirements, including use of qualified agency where directed.

1.2 Become familiar with symbols identifying potential hazards.

1.4 What To Do If Boiler Or Any Part Has Been Under Water

Do not use boiler if any part has been under water. Immediately call a qualified service technician to inspect boiler and to replace any part of control system and any gas control which has been under water.

This is the safety alert symbol. Symbol alerts you to potential personal injury hazards. Obey all safety messages following this symbol to avoid possible injury or death.

!DANGER

Indicates a hazardous situation which, if not avoided, WILL result in death or serious injury

! WARNING

Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

! CAUTION

Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE

Used to address practices not related to personal injury.

2

2 - OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE OPERATING

! WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

This appliance is equipped with an ignition device which automatically lights burner. Do NOT try to light this burner by hand.

Before operating smell all around appliance area for gas. Be sure to smell next to floor because some gas is heavier than air and will settle to the floor.

Use only your hand to turn the gas shutoff valve. Never use tools. If valve will not turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in fire or explosion.

Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect appliance and to replace any part of control system and any gas control which has been under water.

2.1 Operating Instructions

Stop! Read Safety information above.

Set thermostat to lowest setting.

Turn "OFF" all electrical power to appliance.

This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light burner by hand!

Remove front jacket panel.

• Turn gas shutoff valve clockwise to closed position. Handle should be perpendicular to gas pipe. See Figures 2-1 and 2-2.

Wait 5 minutes for any gas to clear. Smell for gas, including near floor. If you smell gas, STOP! Follow instructions on this page: “What To Do If You Smell Gas.” If you do not smell gas, go to next step.

Turn gas shutoff valve counter clockwise to the open position. Handle should be parallel to gas pipe.

Replace front jacket panel.

Turn "ON" electrical power to appliance.

Set thermostat to desired setting.

If the appliance will not operate, follow instructions TO TURN OFF GAS TO APPLIANCE and call your service technician or gas supplier.

! CAUTION

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

2.2 To Turn Off Gas To Appliance

Set thermostat to lowest setting.

Turn "OFF" all electric power to appliance if service is to be performed.

Remove front jacket panel.

• Turn gas shutoff valve handle clockwise to closed position. Handle should be perpendicular to gas pipe. See Figures 2-1 and 2-2.

• Replace front jacket panel.

2-1 Gas Shutoff Valve - 050/075/100/150/200 MBH

OPEN POSITION

GAS SHUTOFF

VALVE

2-2 Gas Shutoff Valve - 299 MBH

CLOSED POSITION

Gas Shutoff Valve

3

3 - FRONT PANEL STATUS INDICATORS

3.1 Front Panel Status Indicators

See Control Module Section for operational states of Front Panel Indicators and User Interface Display.

POWER INDICATOR (Green) Light lit when boiler power ON.

HEAT INDICATOR (Green)

Light lit when boiler is providing heat for central

Heat (CH) or domestic hot water (DHW).

 

Boiler fault detected. Normal Operation suspended. RESET INDICATOR (Red) Manual reset of boiler needed.

See Section 5 troubleshooting.

4

+ 8 hidden pages