U-line SP18 User Manual

0 (0)
U-line SP18 User Manual

USER GUIDE & SERVICE MANUAL

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

RIGHT PRODUCT. RIGHT PLACE. RIGHT TEMPERATURE. SINCE 1962.

Marine Series SP18 15" Crescent Ice Maker

USER GUIDE & SERVICE MANUAL

u-line.com

Table of Contents

Intro

Safety

Safety and Warning

Disposal And Recycling

Installation

Environmental Requirements

Electrical

Cutout Dimensions

Product Dimensions

Water Hookup

General Installation

Integrated Panel Installation

Grille / Plinth Installation

Door Swing

Door Adjust

Maintenance

Door Latch

Cleaning

Cleaning Condenser

Extended Non-Use

Operating Instructions

First Use

Ice

Airflow and Product Loading

Service

Troubleshooting

Wire Diagram

Product Liability

Warranty Claims

Parts

Ordering Replacement Parts

System Diagnosis Guide

Compressor Specifications

Troubleshooting Extended

Defrost

Warranty

USER GUIDE

u-line.com

WELCOME TO U-LINE

Congratulations on your U-Line purchase. Your product comes from a company with over five decades of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine use. U-Line’s complete product collection includes Wine Captain® Models, Beverage Centers, Clear Ice Machines, Crescent Ice Makers, Glass & Solid Door Refrigerators, Drawer Models, Freezers, Combo® Models, and more.

U-Line has captivated those with an appreciation for the finer things with exceptional functionality, style, inspired innovations and attention to even the smallest details. We are known and respected for our unwavering dedication to product design, quality and selection. U-Line is headquartered in Milwaukee, Wisconsin and has shipped product to five continents for over two decades and is proud to have the opportunity to ship to you.

PRODUCT INFORMATION

Looking for additional information on your product? User Guides, Spec Sheets, CAD Drawings, Compliance Documentation, and Product Warranty information are all available for reference and download at u-line.com.

PROPERTY DAMAGE / INJURY CONCERNS

In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following steps:

1.U-Line Customer Care must be contacted immediately at +1.800.779.2547.

2.Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.

GENERAL INQUIRIES

U-Line Corporation

8900 N. 55th Street

Milwaukee, Wisconsin 53223 USA Monday - Friday 8:00 am to 4:30 pm CST T: +1.414.354.0300

F: +1.414.354.7905 Email: sales@u-line.com u-line.com

CONNECT WITH US

SERVICE & PARTS ASSISTANCE

Monday - Friday 8:00 am to 4:30 pm CST T: +1.800.779.2547

F: +1.414.354.5696

Service Email: onlineservice@u-line.com Parts Email: onlineparts@u-line.com

Designed, engineered and assembled in WI, USA

3

Introduction 1

USER GUIDE

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

Safety and Warning

NOTICE

Please read all instructions before installing, operating, or servicing the appliance.

Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide:

SAFETY ALERT DEFINITIONS

Throughout this guide are safety items labeled with a

Danger, Warning or Caution based on the risk type:

! DANGER

Danger means that failure to follow this safety statement will result in severe personal injury or death.

! WARNING

Warning means that failure to follow this safety statement could result in serious personal injury or death.

! CAUTION

Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property or equipment damage.

4

Safety and Warning 1

USER GUIDE

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

Disposal and Recycling

! DANGER

RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside.

If the unit is being removed from service for disposal, check and obey all federal, state and local regulations regarding the disposal and recycling of refrigeration appliances, and follow these steps completely:

1.Remove all consumable contents from the unit.

2.Unplug the electrical cord from its socket.

3.Remove the door(s)/drawer(s).

5

Disposal and Recycling 1

USER GUIDE

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

Environmental Requirements

This model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements.

This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models.

For best performance, keep the unit out of direct sunlight and away from heat generating equipment.

In climates where high humidity and dew points are present, condensation may appear on outside surfaces. This is considered normal. The condensation will evaporate when the humidity drops.

! CAUTION

Damages caused by ambient temperatures of 40°F (4°C) or below are not covered by the warranty.

6

Environmental Requirements 1

USER GUIDE

u-line.com

Electrical

! WARNING

SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected.

Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.

Altering, cutting or removing power cord, removing power plug, or direct wiring can cause serious injury, fire, loss of property and/or life, and will void the warranty.

Never use an extension cord to connect power to the unit.

Always keep your working area dry.

NOTICE

Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three-prong), polarized receptacle that has been placed by a qualified electrician.

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. A GFCI (ground fault circuit interrupter) is usually not required for fixed location

appliances and is not recommended for your unit because it could be prone to nuisance tripping. However, be sure to consult your local codes.

See CUTOUT DIMENSIONS for recommended receptacle location.

Electrical

7

USER GUIDE

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

Cutout Dimensions

PREPARE SITE

Your U-Line product has been designed for either freestanding or built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grille must NOT be obstructed, and clearance is required for an electrical and water connection in the rear.

! CAUTION

Units can NOT be installed behind a closed cabinet door.

CUTOUT DIMENSIONS

Filler Panel (Not Provided by U-Line) – Needed to Attach Mounting Flange on Unit

 

3/4" (19 mm) Minimum

 

Flange Mounting Area

 

Preferred location

 

 

for electrical outlet

 

 

LV LQ DGMDFHQW

 

 

cabinet.

 

Cutout

 

5/8"

Height

7"

(16 mm)

18-7/8"

(178 mm)

 

(479 mm)

 

 

 

4"

 

 

(102 mm)

 

See Electrical

6SHFLɟFDWLRQV for Power Supply

26" (660 mm) Minimum

3/4"

 

 

 

14-1/4"

 

3/4" Toe Kick

 

 

 

(19 mm)

(362 mm)

(19 mm)

Minimum Flange

Cutout Width

Minimum Flange

Mounting Area

 

 

 

Mounting Area

NOTICE

It is extremely important that this unit sits on a level surface, as it does not have feet levelers. If it is not level, the ice mold will not fill evenly.

8

Cutout Dimensions 1

USER GUIDE

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

Product Dimensions

15-1/8"

(384 mm)

18-7/8"

(479 mm)

7 9/16"

1/2"

24-1/2" (622 mm) *

*Add 1-1/2" For Water Line Clearance

9

Product Dimensions 1

USER GUIDE

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

Water Hookup

! CAUTION

PREPARE PLUMBING

The water valve uses a standard 1/4" (6.35 mm) compression fitting. U-Line recommends using accessory water hook up kit – part # 80-54674-00. The kit includes a 10' (3 m) braided flexible water supply line and a brass hose fitting.

! CAUTION

Plumbing installation must observe all state and local codes. All water and drain connections MUST BE made by a licensed/qualified plumbing contractor. Failure to follow recommendations and instructions may result in damage and/or harm.

Water Supply Connection

When connecting the water supply, please note the following:

Before installing the unit and connecting to the cold water supply, review the local plumbing codes.

The water pressure should be between 20 and 120 psi (138 and 827 kPa).

The water line MUST have a shut-off valve in the supply line.

The water line should be looped into 2 coils. This will allow the unit to be removed for cleaning and servicing. Make certain that the tubing is not pinched or damaged during installation.

Do not use any plastic water supply line. The line is under pressure at all times. Plastic may crack or rupture with age and cause damage to your home.

Do not use tape or joint compound when attaching a braided flexible water supply line that includes a rubber gasket. The gasket provides an adequate seal – other materials could cause blockage of the valve.

Failure to follow recommendations and instructions may result in damage and/or harm, flooding or void the product warranty.

Use new hose set. Do not reuse old hose set.

! CAUTION

Turn off water supply and disconnect electrical supply to unit prior to installation.

Use caution when handling back panel. The edges could be sharp.

1.Turn off water supply and disconnect electrical supply to product prior to attempting installation.

2.Remove the back panel.

! WARNING

Connect to potable water supply only.

10

Door Swing 1

USER GUIDE

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

3. Locate water valve inlet.

9. Install retaining clip.

4. Break away filler feature in bushing with flat screwdriver.

Remove

ZLWK ɠDW screwdriver

5. Thread water line through back panel hole (with bushing).

6. Locate water valve inlet and connect to valve.

7.Turn on water supply and check for leaks.

8.Reinstall back panel.

11

Door Swing 2

USER GUIDE

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

General Installation

INSTALLATION

LEVELING INFORMATION

1.

Plug in the power/electrical cord.

 

 

NOTICE

2.

Gently push the unit into position. Be careful not to

 

entangle the cord and water line.

Because these units do not have leveling legs, it

 

 

 

is extremely important that they sit on a level

 

 

surface. If they are not level, the ice mold will

3.

Re-check the leveling, from front to back and side to

not fill evenly.

 

side. Make any necessary adjustments.

Use a level to confirm

4.

Remove the interior packing material and wipe out the

the unit is level. Level

 

inside of the unit with a clean, water-dampened cloth.

should be placed along

 

 

top edge and side edge

 

 

as shown.

 

 

1

12

General Installation 1

USER GUIDE

u-line.com

SAFETY • INSTALLATION & INTEGRATION

Integrated Panel Installation

This model accepts a 1/4" insert panel.

INSERT PANEL INSTALLATION

Install the insert as follows:

! CAUTION

OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

5.Slide custom door panel insert into 1/4" (6 mm) channel in door front.

6.Holding door gasket out of the way, replace handle on door, making sure it is seated properly on insert and that screw holes line up.

7.Install two small screws removed in Step 3.

Use care when handling the insert. Insert edges may be sharp.

1. Remove top hinge screw pin with Phillips head screwdriver. Remove door by tilting forward and lifting off bottom hinge pin.

2. Pull door gasket out of groove (top edge of door only). Start in the middle and pull outward, moving toward the edge. This may take some force.

3. Remove top screw on each side securing door handle. Slightly separate door handle from door.

8.Starting at the corners and working inward, push door gasket into place on door.

9.Place door on bottom hinge pin and install upper hinge screw.

4. Pull handle up and off.

13

Integrated Panel Installation 1

USER GUIDE

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

Grille - Plinth Installation

REMOVING AND INSTALLING GRILLE

! WARNING

Disconnect electric power to the unit before removing the grille.

When using the unit, the grille (plinth strip/base fascia) must be installed.

! WARNING

DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.

Removing the grille

1.Disconnect power to the unit.

2.Loosen the three screws (1).

3.Remove grille (2) from unit.

Installing the grille

1.Align cabinet and grille holes and secure, but do not over tighten grille screws (1).

2.Reconnect power to the unit.

1

2

14

Grille - Plinth Installation 1

USER GUIDE

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

Door Swing

All units have a zero clearance for the door to open 90°. U-Line recommends a minimum door clearance of 3/4" (19 mm) to accommodate the handle if the unit is installed next to a wall or similar type of structure.

Wall

3/4" (19 mm) Min.

90° Door Swing

15

Door Swing 1

Loading...
+ 34 hidden pages