Tyco 420G User Manual

4.5 (2)
Tyco 420G User Manual

GoodKnight® 420G

Patient Manual

Ref. : M-139DFU02-10 Revision C

Revision C

List of Patient Manual revisions

GoodKnight® 420G

The pages below are included in the American version of the GoodKnight® 420G patient manual Ref. M-139DFU02-10 revision C.

Current pages

Revision

Cover

C

 

 

List of revisions

C

 

 

Table of contents

A

 

 

Introduction

A

 

 

1 – 8 ; 11 – 20

A

 

 

9–10 ; 21

B

 

 

22

C

 

 

Reference or revision

Description

Date

M-139DFU02-10 revision A.

Creation of the manual

February 2002

Revision B.

Modification of the manual (sections “Installing a

October 2003

 

humidifier” and “Electrical characteristics of the

 

 

power supply module”)

 

Revision C.

Modification of the manual (Implementation of the

July 2005

 

CE-mark in the section “Symbols” and Nellcor

 

 

Puritan Bennett trademark)

 

 

 

 

© 2002 2005 Nellcor Puritan Bennett Inc. All rights reserved.

ii

GoodKnight 420G - Patient Manual

Revision C

The Puritain Bennett GoodKnight® 420G device (GK420G) is intended for treating patients with Sleep Disordered Breathing including Obstructive Sleep Apnea Syndrome (OSAS). The main characteristic of this pathology is the occurrence of multiple respiratory events caused by contraction of the upper airways that disturb sleep. The GoodKnight 420G delivers a Continuous Positive Airway Pressure (CPAP) that prevents the upper airways from becoming obstructed thus eliminating apneas.

It is essential for you to understand the limitations on the use of this device. Therefore, please read this manual carefully before using the GoodKnight 420G.

The information contained here is intended to help you use this device under optimum conditions of safety and operation. For any question relating to the equipment and its use, contact your Health Care Provider or your home Medical Equipment Provider.

Your doctor has decided on the treatment of your illness. He or she has prescribed the various parameters that the hospital or your home care provider will program. You must not make any adjustment, except under direct supervision of your Home Care Provider.

CAUTION

Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.

GoodKnight® is a registered trademark of Nellcor Puritan Bennett Inc.

GoodKnight 420G - Patient Manual

iii

This page is left blank intentionally

iv

GoodKnight 420G - Patient Manual

Revision A

TABLE OF CONTENTS

BEFORE STARTING............................................................................................................................................................

1

SAFETY INSTRUCTIONS......................................................................................................................................................

1

INDICATIONS FOR USE .......................................................................................................................................................

2

PRECAUTIONS FOR USE......................................................................................................................................................

2

CHECKING THE COMPONENTS............................................................................................................................................

3

DESCRIPTION OF THE DEVICE......................................................................................................................................

4

INSTALLATION ...................................................................................................................................................................

7

STANDARD INSTALLATION ................................................................................................................................................

7

FITTING AN OXYGEN ADAPTOR..........................................................................................................................................

8

INSTALLING A HUMIDIFIER ................................................................................................................................................

9

INSTALLING AN EXTERNAL BATTERY ..............................................................................................................................

10

USE ........................................................................................................................................................................................

11

STARTING TREATMENT....................................................................................................................................................

11

STOPPING TREATMENT ....................................................................................................................................................

12

USING THE RAMP.............................................................................................................................................................

12

ACCESSING INFORMATION ON THE DEVICE......................................................................................................................

14

SETTING THE TIME...........................................................................................................................................................

15

MAINTENANCE AND CLEANING INSTRUCTIONS ..................................................................................................

17

GOODKNIGHT 420G .......................................................................................................................................................

17

AIR INLET FILTERS ..........................................................................................................................................................

17

HOSE...............................................................................................................................................................................

17

NASAL MASK ..................................................................................................................................................................

18

HUMIDIFIER ....................................................................................................................................................................

18

OXYGEN ADAPTOR ..........................................................................................................................................................

18

TROUBLE-SHOOTING......................................................................................................................................................

19

TECHNICAL CHARACTERISTICS ................................................................................................................................

21

DEVICE PERFORMANCE ...................................................................................................................................................

21

PHYSICAL CHARACTERISTICS ..........................................................................................................................................

21

TRANSPORT AND STORAGE CONDITIONS .........................................................................................................................

21

CONDITIONS OF USE ........................................................................................................................................................

21

DISPOSAL OF THE GOODKNIGHT 420G AT THE END OF ITS LIFE ..................................................................................

21

ELECTRICAL CHARACTERISTICS OF THE POWER SUPPLY MODULE....................................................................................

22

ELECTRICAL CHARACTERISTICS OF THE DEVICE ..............................................................................................................

22

SYMBOLS ........................................................................................................................................................................

22

GoodKnight 420G - Patient Manual

v

This page is left blank intentionally

GoodKnight 420G - Patient Manual

vi

Revision A

BEFORE STARTING

Safety instructions

In order to ensure that you use your GoodKnight 420G device safely and efficiently, please read all the information contained in this operating manual. Please pay special attention to the passages preceded by the following terms:

WARNING Means that there is a danger of death or accident to you or others.

CAUTION Means that there is a possibility of material damage to this or another device.

NOTE

Indicates special points aimed at more efficient and practical operation.

WARNINGS

1.Before any use, please check your GoodKnight 420G, as specified in the chapter “Checking the components”. (See page 3).

2.In the event of additional oxygen supply, carefully observe the safety instructions for using oxygen given in the chapter “Fitting an oxygen adaptor”. (See page 8).

3.Only use the accessories that have been given to you by your service provider. Check that you have the instructions for using each of the accessories and read through them.

4.Use only the specific power supply module provided with the device.

5.Do not use the device in the presence of flammable fumes.

6.Follow the device’s installation instructions as specified in this manual in the chapter “Installation”. (See page 5). In particular, keep the machine away from any sources of water.

7.Do not accidentally or intentionally obstruct the air outlet or any other opening in the device or the respiratory circuit.

8.Do not introduce liquids or objects into the air outlet.

9.You may contact the medical team if, when using the GoodKnight 420G, the following symptoms appear: dryness in your airways or nose, skin sensitivity, runny nose, earache, sinus trouble, daytime drowsiness, mood changes, disorientation, irritability or memory loss.

10.Contact your home care provider in the event of any malfunction, whatever it may be. Maintaining this equipment is solely the responsibility of the competent personnel. Do not attempt to open the device.

11.The air flow for breathing produced by this device can be as much as 7°F higher than the temperature of the room. Caution should be exercised if the room temperature is warmer than 90°F.

GoodKnight 420G - Patient Manual

1

Revision A

Indications for use

The GoodKnight 420G device is indicated for use in the treatment of obstructive respiratory sleep disorders, particularly Obstructive Sleep Apnea (OSA) in spontaneously breathing patients weighing over 30 kg (66 lb) within a homecare environment.

Precautions for use

The GoodKnight 420G device must be used with caution with patients in the following conditions. If you are affected by one of these, contact your doctor at the start of your treatment.

Pneumothorax or pneumomediastinum

Severe bullous emphysema or previously complicated by pneumothorax

Massive epistaxis or previous massive epistaxis

Decompensated cardiac insufficiency or hypotension, especially in case of depletion in blood volume or in case of cardiac rhythm disorder

Pneumoencephalus, traumatism or recent surgery with the after-effect of a cranio-nasopharyngeal fistula

Acute sinusitis, otitis media or perforation of the tympanic membrane

Severe claustrophobia.

2

GoodKnight 420G - Patient Manual

Revision A

Checking the components

In order to be able to use the GoodKnight 420G with its specific electrical power supply, you must have at least the following items:

A patient tubing.

A nasal mask (often called an “ interface ”) with all its fastening accessories as specified in the instructions for using this mask.

In addition to these accessories, your doctor could have prescribed the use of a humidifier. In this case, check that you have all the accessories for this humidifier specified in its operating instructions.

In the case of an additional oxygen supply, you must also have an adaptor (only in the case where the oxygen supply is not fitted directly onto the mask). See the chapter “Fitting an oxygen adaptor”. (See page 8).

Carefully check the device and each accessory. Check especially that the hoses are not damaged and that the mask does not have any cracks or distortion in the mask housing or seal (part of the mask coming in contact with the face).

Carefully check the device and the specific power supply module and verify that there is no obvious fault. Plug the device to the mains using its power supply module, referring to steps 4 and 5 of the chapter “Standard installation”. (See page 7).

The type of the device is displayed for a few seconds then the following standby screen showing the hour (the value displayed is given as example):

9:31

Standby Indicator

(the two points are blinking).

Figure 1 – View of the display when the device is in standby mode

If the device was disconnected while the motor was running, the screen displays the pressure. The device shows the same adjustments as at the time of the power supply cord disconnection and is set on the pressure used at the time of disconnection.

Start the device by pressing the ON/OFF button. (See reference 4 in Figure 2, page 5). The blower should start up and the noise should be regular.

Stop the device by pressing the ON/OFF button and unplug the power supply lead from the mains.

WARNING

In the event of problems or if you discover any anomaly, do not start the treatment and contact your home service provider.

GoodKnight 420G - Patient manual

3

Loading...
+ 21 hidden pages