Information marked with this symbol indicates that the
operating manual must be observed.
Wear hearing protection!
Indicates the activities during which hearing protection is
to be worn.
1Operating manual – Conveying fa n TTV 1500 / TTV 2500EN
Page 3
Warranty and liability
The device complies with the fundamental health and safety
requirements of the applicable EU regulations and was tested at
the factory for perfect functionality multiple times.
However, if faults in the functionality occur and cannot be
remedied with the measures in the Errors and faults chapter,
please get in touch with your dealer or distributor.
When manufacturer's instructions or legal regulations have not
been followed, or after unauthorised changes to the device are
made, the manufacturer is not responsible for the resulting
damages. Changes to the device or unauthorised replacement of
individual parts can drastically impact the electrical safety of this
product and leads to the forfeit of the warranty. Liability does not
extend to damages to people or property caused by the device
being used other than as described in the instructions in this
operating manual.
Subject to changes to technical design and model changes as
part of constant development and product improvement without
prior notice.
No liability is accepted for damages resulting from improper use.
In such a case, any warranty claims will be voided also.
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity of
the device or its site of use.
Warning!
Improper handling can lead to injuries due to parts
being whirled up.
• Do not use the device in potentially explosive rooms.
• Do not use the device in aggressive atmosphere.
• Set the device up in an upright and stable position.
• Let the device dry out after a wet clean. Do not operate it
when wet.
• Do not use the device with wet or damp hands.
• Do not expose the device to directly squirting water.
• Never insert any objects or limbs into the device.
• Do not cover or transport the device during operation.
• Do not sit on the device.
• This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.
• Check accessories and connection parts for possible damage
prior to every use of the device. Do not use any defective
devices or device parts.
• Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never use
the device if the cable or power connection is damaged!
• The electrical connection must correspond to the
specifications in the Technical data chapter.
• Insert the mains plug into a properly secured mains socket.
• Observe the technical data when selecting extensions to the
power cable. Completely unroll the extension cable. Avoid
electrical overload.
• Hold onto the mains plug while pulling the power cable out of
the mains socket.
• Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
• Do not under any circumstances use the device if you detect
damages on the plug or cables. Defective power cables pose
a serious health risk.
• Observe the operating conditions (see chapter Technical
data).
• Remove the mains plug from the mains socket before
carrying out maintenance, care or repair work on the device.
• Make sure that the air inlet and outlet are not obstructed.
• Make sure that there are no loose items located in the
immediate surroundings of air inlet and air outlet.
• Improper installation can lead to a fire, electric shock or
severe personal injury.
Intended use
The conveying fan TTV 1500 / TTV 2500 may be used for
aeration, deaeration, air circulation, dust collection or air
transport whilst adhering to the technical data and the safety
instructions.
The device is designed for aeration and deaeration tasks, for the
generation of a high air exchange rate even in shafts and ducts
and over long distances.
Improper use
The conveying fan TTV 1500 / TTV 2500 is not suited for
installation in fluids or on flooded or boggy grounds.
Any unauthorised changes, modifications or alterations to the
device are forbidden.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when using conveying
fans.
• have read and understood the operating manual, especially
the Safety chapter.
ENOperating manual – Conveying fan TTV 1500 / TT V 25002
Page 4
Personal protective equipment
2
1
3
4
6
5
2
Wear hearing protection!
Wear hearing protection when spending a longer period
of time in the vicinity of the device.
Residual risks
Warning of electrical voltage!
Work on the electrical components must only be carried
out by an authorised specialist company!
Warning of electrical voltage!
Before any work on the device, remove the mains plug
from the mains socket!
Warning of strong air current!
Risk of injury from parts being whirled up.
Before switching the device on, make sure that there
are no loose parts located near air inlet or outlet!
Warning of loose parts being drawn in!
Keep a minimum distance of 3 m from the device on
the suction side!
Device depiction
Warning!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Behaviour in the event of an emergency
1. Press the On/Off switch to switch off the device immediately.
2. Remove persons from the danger area.
3. Disconnect the device from the electric circuit.
4. Do not reconnect a defective device to the mains.
Information about the device
The conveying fan TTV 1500 / TTV 2500 was designed for a high
air volume flow.
The high air volume flow and a variety of configuration options
enable its flexible application ranging from humidity regulation to
the transport of fresh air or exhaust air over longer distances.
The device is equipped with bilateral hose connectors allowing to
connect, for instance, an air transport hose to the air inlet and a
dust bag to the air outlet.
This makes the conveying fan an ideal transport fan for far-off
connected air conditioning or heating applications.
It thus allows to increase the conveying distance of warm or cold
air.
No.Designation
1Transport handle
2Connector for air hose (optional)
3Air outlet
4On/Off switch
5Power cable with Schuko plug CEE 7/7
6Air inlet
Scope of delivery
•Device
•Manual
Storage
When the device is not being used, observe the following storage
conditions:
• in dry surroundings,
• protected from dust and direct sunlight,
• with a plastic cover to protect it from invasive dust, if
necessary.
When the device is not in use, the power cable can be wound
around the hose connection.
3Operating manual – Conveying fa n TTV 1500 / TTV 2500EN
Page 5
Start-up
8
87
7
Errors and faults
1. Take the device out of the cardboard box and remove the
plastic packaging.
2. Unwind the power cable.
3. Set the device up in an upright and stable position. Observe
a minimum distance of 50 cm to walls and other objects.
4. Assemble the device according to the desired area of
application along with other devices or accessories.
5. Connect the hoses or dust bags as follows:
– Pull the air hose/dust bag (7) completely over the
connector.
– Fasten the air hose/dust bag with a tension belt (8).
The device has been checked for proper functioning several times
during production. If malfunctions occur nonetheless, check the
device according to the following list.
The fan is not running:
• Check whether the unit is switched on.
• Check the power supply.
• Check the power cable and mains plug for defects.
The fan operates only for a short time, then switches off
automatically:
• Check whether the protective grid is blocked and clean it if
required.
• The motor bearing or cable connections are defective. If so,
contact your dealer.
Your device still does not operate correctly after these
checks?
• Bring the device to a specialist company or to Trotec for
repairs.
Maintenance
6. Plug the mains plug of the power cable into a properly fused
socket.
– The fan is now ready for operation.
Operation
Switching the device on
• Use the On/Off switch (4) to switch the device on.
Shutdown
Warning of electrical voltage!
Do not touch the mains plug with wet or damp hands!
1. Switch off the device.
2. Remove the mains plug from the mains socket.
3. Clean the device according to the Maintenance chapter.
4. Store the device according to the Storage chapter.
Activities required before starting maintenance
• Before any work, remove the mains plug!
Maintenance tasks which require the housing to be
opened must only be carried out by Trotec.
• Always pull the mains plug before starting any care or
maintenance work.
• Regularly check the housing for its perfect condition or for
defects.
• Always be mindful of atypical sounds and consult a specialist
dealer if in doubt.
• Keep the fan clean.
• You can use a compressor to remove particles, lint, dust and
dirt from the motor, fan wheel and protective grid. Do not in
any event use a high-pressure cleaner to clean the fan.
• Maintenance and repair work may only be carried out by
Trotec.
ENOperating manual – Conveying fan TTV 1500 / TT V 25004
Page 6
Disposal
In the European Union, electronic equipment must not
be treated as domestic waste, but must be disposed of
professionally in accordance with Directive 2002/96/EC of the
European Parliament and of the Council of 27 January 2003 on
waste electrical and electronic equipment (WEEE). At the end of
its life, please dispose of this device according to the valid legal
requirements.
Technical annex
Technical data
ParameterValue
ModelTTV 1500TTV 2500
Article number1.510.000.0061.510.000.007
Amount of air
Air pressure225 Pa300 Pa
Voltage230 V / 50 Hz230 V / 50 Hz
Power input0.17 kW0.44 kW
Fusing10 A10 A
Transport medium
temperature
Hose connector∅ 200 mm∅ 300 mm
Hose lengthMax. 15 mMax. 38 m
Noise level
5Operating manual – Conveying fa n TTV 1500 / TTV 2500EN
Page 7
Declaration of conformity (Translation of the Original)
EC Declaration of Conformity
in accordance with EC Machinery Directive 2006/42/EC
TROTEC
®
GmbH & Co. KG
Grebbener Straße 7
D-52525 Heinsberg
herewith declares that due to their design and construction, and in the version introduced by us, the
following machines conform with the relevant fundamental requirements of the listed EC directives.
Important note:
In case of improper use, installation, maintenance etc. or unauthorized changes of the
factory-supplied device version, this declaration loses its legal validity.
Machinery Directive
Low Voltage Directive
EMC Directive
EN 55014-1:2006+A1:2009+A2:2011
EN 61000-3-2:2006+A1:2009+A2:2009
EN 61000-3-3:2013
EN 55014-2:1997+A1:2001+A2:2008
EN 61000-4-2:2009, EN 61000-4-4:2012
EN 61000-4-5:2006, EN 61000-4-6:2014
EN 61000-4-11:2004
Producer and authorised representative of the technical documentation:
Trotec GmbH & Co. KG · Grebbener Straße 7 · D-52525 Heinsberg
Phone: +49 2452 962-400 · Fax: +49 2452 962-200 · E-mail: info@trotec.com
Heinsberg, 8th June 2016
ENOperating manual – Conveying fan TTV 1500 / TT V 25006
Managing Director: Detlef von der Lieck
Page 8
Trotec GmbH & Co. KG
Grebbener Str. 7
D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
info@trotec.com
www.trotec.com
Loading...
+ hidden pages