Tripp Lite Network Dataline Surge Suppressors are designed to protect data and communications equipment against AC transients caused by lightning, electrostatic discharge and ground surges that can enter equipment from the signal lines or chassis ground.

Tripp Lite Network Dataline Surge Suppressors described here protect virtually any pieces of networked equipment using 100Base-T, 10Base-T, 10Base-2 and 10Base-5 Ethernet, Token Ring, RS232, RS422/423/485, parallel, dial-up modems, fax, ISDN, DDS, T-1 and most other communication interfaces.

Installation

1.Make sure the computer, network device or other equipment is logged OFF the network (if applicable). Turn OFF power to the equipment.

2.Disconnect the cable from the equipment to be protected.

3.Connect the Tripp Lite Network Dataline Surge Suppressor directly to the equipment. DB9 and DB25 models are reversible, to work with male or female ports. To change gender, remove the thumbscrews, reverse their direction and reinstall.

4.Attach the green ground wire on the surge suppressor directly to the protected equipment’s chassis. (Except DB9, DB15 and DB25 models.)

5.Reconnect the cable to the Tripp Lite Network Dataline Surge Suppressor.

NOTE!

The Tripp Lite Network Dataline Surge Suppressor must be properly grounded and positioned as close as possible to the equipment to be protected. For best results, it is required that the length of the signal line and ground wire (if equipped) between the surge suppressor and the protected equipment be kept as short as possible, not to exceed 12 inches (12”). It is best to install the surge suppressor directly to the equipment, as noted above.

NOTE!

Installing a typical Tripp Lite Network Dataline Surge Suppressor is equivalent to adding approximately three feet (3’) of typical data communication cable to a segment.

CAUTION!

The Tripp Lite Network Dataline Surge Suppressor does not protect the equipment on the opposite end of the cable. Normally, protection at both ends is recommended.

CAUTION!

When properly installed, the Tripp Lite Network Dataline Surge Suppressor will only protect against surges on the dataline portion of your installation. Simultaneous AC surge suppression/power protection in the form of an ISOBAR® surge suppressor or Tripp Lite UPS system is strongly recommended for complete system/network protection and can also extend Ultimate Lifetime Insurance coverage to connected equipment.

1

SPECIFICATIONS All surge suppressors listed have component response times of less than 1 picosecond.

Model:

Description:

Nominal

Peak Pulse

Clamping Voltage:

Current:

DHUB

 

 

 

DHUB-18V

DHUB: RJ45, 8-port

 

 

 

ethernet, token ring

7.5 volts, protecting

750 amps

 

RS422/423/485, AS400/

 

Sys3x protector for hubs,

wires 1-8 on all ports.

 

 

 

 

 

repeaters, terminal

 

 

 

servers, MUXs, MAUs,

 

 

 

etc.*

 

 

 

DHUB-18V: RJ45, 8-port

18 volts, protecting

340 amps

 

wires 1-8 on all ports.

 

 

RS 232 protector for

 

 

 

 

* Supplied with eight 4” RJ45 patch cables.

multiport serial devices.*

 

 

DRS232

 

 

 

 

RJ45/RJ11 protector for

 

 

 

100Base-T4, RS-232 on

18 volts, protecting wires

340 amps

 

twisted pair (wires 1-8) or

 

1-8.

 

 

ISDN “S/T” interfaces.

 

 

 

 

 

Supplied with 4” RJ45

 

 

 

patch cable.

 

 

 

 

 

 

DNET1

RJ45 100Base-T, 10Base-T,

 

 

 

 

 

 

Token Ring, RS422, AS400/

7.5 volts, protecting

750 amps

 

Sys3x protector for NICs,

 

hubs, routers, etc. Supplied

wires 1-8.

 

 

with 4” RJ45 patch cable.

 

 

 

 

 

 

DSUT1CSU

RJ45/RJ11 protector for

 

 

 

nonspan powered T-1

 

 

 

equipment , digital data

60 volts, protecting wires

200 amps

 

service CSUs/DSUs, ISDN

 

“U” interfaces or other

1-8.

 

 

digital lines. Supplied

 

 

 

with 4” RJ45 patch cable.

 

 

DTEL2

 

 

 

 

RJ45/RJ11 for modems,

260 volts, protecting

250 amps

 

answering and fax

 

machines. Supplied with

center 4 wires (2 CO-

 

 

4” RJ11 patch cable.

lines).

 

 

 

 

 

DB9

Serial DB9 RS-232

 

 

 

protector for male or

 

 

 

female ports of data

 

 

 

terminal and computing

18 volts, protecting

340 amps

 

equipment including

 

PCs, modems, etc. (any

pins 1-9 and chassis.

 

 

male or female 9 pin

 

 

 

port). Male/Female

 

 

 

genders are reversible

 

 

 

with reversible

 

 

DB15AUI

thumbscrews.

 

 

 

7.5 and 18 volts,

 

 

DB15 ethernet AUI

750 amps

 

protecting all IEEE

 

protector.

 

802.3 pins.

 

 

 

 

 

 

 

 

2

Model:

Description:

Nominal

Peak Pulse

Clamping Voltage:

Current:

 

 

 

 

DB25

Serial DB25 RS-232

 

 

protector (wires 1-8,

 

 

DB25-ALL

 

 

20) for male or female

 

 

 

 

 

 

ports of data terminal

 

 

 

& computing

18 volts, protecting

 

 

equipment. DB25-ALL:

340 amps

 

Serial DB25 RS-232

pins 1-8, 20 and chas-

 

 

 

protector (pins 1-25)

sis.

 

 

for any 25 pin male or

 

 

 

female DTE/DCE

 

 

 

ports. Male/Female

 

 

 

genders are reversible

 

 

 

with reversible

 

 

 

thumbscrews.

 

 

 

 

 

 

DB25-PAR

 

 

 

 

Parallel port DB25

7.5 volts, protecting

750 amps

 

protector (pins 1-25).

pins 1-25 and chassis.

 

 

 

 

 

D10B5

10Base-5 thick coax

7.5 volts, protecting

 

 

 

 

protection with “N”

center, shield and

750 amps

 

type male/female

chassis.

 

 

connectors.

 

 

 

 

 

 

D10B2-T

10Base-2 thin coax

7.5 volts, protecting

 

 

 

 

protected “T” (BNC f/

750 amps

 

center, shield and

 

m/f). Also protects IBM

 

chassis.

 

 

3270 and CCTV lines.

 

 

 

 

 

 

 

 

D10B2

10Base-2 thin coax

7.5 volts, protecting

 

 

 

 

protector (BNC m/f). Also

 

 

center, shield and

750 amps

 

protects IBM 3270 and

 

chassis.

 

 

CCTV lines.

 

 

 

 

 

 

 

 

DTWINAX

 

 

 

 

Twinaxial AS400 Sys3x

10 volts, protecting

500 amps

 

protector (m/f).

both signal lines,

 

 

 

 

shield and chassis.

 

 

 

 

 

DCATV

 

 

 

 

Coaxial protector for

7.5 volts, protecting

 

 

TVs, VCRs, pro

750 amps

 

center and shield

 

video supplied by

 

 

conductors.

 

 

CATV

 

 

 

 

 

(“F” m/f).

 

 

 

 

 

 

Call Tripp Lite Customer Support at (773) 869-1234 for additional applications

3

requiring Multiport, Terminal Strip, RS422/RS423/RS485 or other interfaces.

 

LIFETIME LIMITED WARRANTY

Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects in material and workmanship for its lifetime. If the product should prove defective in material or workmanship within that period, Seller will repair or replace the product, in its sole discretion. Service under this Warranty can only be obtained by your delivering or shipping the product (with all shipping or delivery charges prepaid) to: Tripp Lite, 1111 W. 35th Street, Chicago, IL 60609. Seller will pay return shipping charges. Call Tripp Lite at (773) 869-1234 before sending any equipment back for repair.

THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT, MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES. (Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights, and you may have other rights which vary from jurisdiction to jurisdiction.)

TRIPP LITE

1111 W. 35th Street

Chicago, IL 60609 USA

WARNING: The individual user should take care to determine prior to use whether this device is suitable, adequate or safe for the use intended. Since individual applications are subject to great variation, the manufacturer makes no representation or warranty as to the suitability or fitness of these devices for any specific application.

Policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.

4

Loading...
+ 8 hidden pages