Toshiba RAV-SM804UT-E, RAV-SM1104UT-E, RAV-SM1404UT-E, RAV-SM1604UT-E, RAV-SM564UT-E User Manual

0 (0)

AIR CONDITIONER (SPLIT TYPE)

Owner’s Manual

Indoor Unit

Model name:

4-way Air Discharge Cassette Type

RAV-SM564UT-E

RAV-SM804UT-E

RAV-SM1104UT-E

RAV-SM1404UT-E

RAV-SM1604UT-E

Not accessible to the general public Vente interdite au grand public Kein öffentlicher Zugang Non accessibile a clienti generici

No destinado al público en general Não acessível ao público em geral Niet geschikt voor huishoudelijk gebruik

Μη προσβάσιμο από το γενικό κοινό

Недоступен для посторонних

Genel erişime açık değildir

Owner’s Manual

 

English

Air conditioner (Split type)

1

 

 

 

Manuel du proprietaire

 

 

 

Français

Climatiseur (Type split)

25

 

 

 

Betriebsanleitung

 

 

 

Deutsch

Klimagerät (Split-typ)

49

 

 

 

Manuale del proprietario

 

 

 

Italiano

Condizionatore d’aria (Tipo split) 73

 

 

 

Manual del propietario

 

 

 

Español

Aire acondicionado (Tipo split)

97

 

 

 

Manual do utilizador

 

 

 

Português

Ar condicionado (Tipo split)

121

 

 

 

Gebruiksaanwijzing

 

 

 

Nederlands

Airconditioner (Gesplitst type)

145

 

 

 

Εγχειρίδιο χρήσης

 

 

 

Ελληνικά

Κλιματιστικό (Τύπου Split)

169

 

 

 

Руководство пользователя

 

 

 

 

Кондиционер воздуха

193

Русский

(Сплит-система)

Kullanım Kılavuzu

 

 

 

Türkçe

Klima (Split tip)

217

 

 

 

4-way Air Discharge Cassette Type

Owner’s Manual

Thank you very much for purchasing TOSHIBA Air Conditioner.

Please read this owner’s manual carefully before using your Air Conditioner.

Be sure to obtain the “Owner’s manual” and “Installation manual” from constructor (or dealer). Request to constructor or dealer

Please clearly explain the contents of the Owner’s manual and hand over it.

ADOPTION OF NEW REFRIGERANT

This Air Conditioner is a new type which adopts a new refrigerant HFC (R410A) instead of the conventional refrigerant R22 in order to prevent destruction of the ozone layer.

This appliance is not intended for use by person (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Contents

 

1

PRECAUTIONS FOR SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 2

2

PARTS NAME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

3

PARTS NAME OF REMOTE CONTROLLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

4

CORRECT USAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

5

TIMER OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

6

ADJUSTMENT OF WIND DIRECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

7

HOW TO ENABLE POWER SAVING MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

8

SELF CLEANING MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

9

ADVANCED SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

 

How to set up swing type

 

 

How to set up louver lock (No swing)

 

 

How to set up power saving mode

 

10 HINTS FOR ECONOMICAL OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18

11 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

12 AIR CONDITIONER OPERATIONS AND PERFORMANCE . . . . . . . . . . . . . . . . . . . .

21

13

INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

22

14 TROUBLES AND CAUSES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

23

1-EN

– 1 –

4-way Air Discharge Cassette Type

Owner’s Manual

1 PRECAUTIONS FOR SAFETY

WARNING

WARNINGS ABOUT INSTALLATION

Make sure to ask the qualified installation professional in electric work to install the air conditioner.

If the air conditioner is inappropriate installed by yourself, it may cause water leak, electric shock, fire, and so on.

• Be sure to connect earth wire. (grounding work) Incomplete grounding cause an electric shock.

Do not connect ground wires to gas pipes, water pipes, lightning rods or ground wires for telephone wires.

• If you install the indoor unit in a small room, take appropriate measures to prevent the refrigerant from exceeding the limit concentration even if it leaks.

Consult the dealer from whom you purchased the air conditioner when you implement the measures. Accumulation of highly-concentrated refrigerant may cause an oxygen deficiency accident.

• Check whether the piping work has been properly completed.

 

When existing pipes are used and if they are not constructed properly, the

 

refrigerant gas may leak. Contact the installation company and confirm that

 

the piping work has been properly completed. For details of installation of

 

the air conditioner, refer to the Installation Manual. Use tools and piping

EN

materials for R410 only. Failure to do so or improper installation may cause

a burst of pipe, resulting in injury.

 

WARNINGS ABOUT OPERATION

Cleaning of the air filter and other parts of the air filter involves dangerous work in high places, so be sure to have a service person do it.

The self cleaning function of the air conditioner causes the internal fan to run at a high speed in some modes even while the air conditioner is not working, which may cause injury.

Do not attempt it yourself.

Avoid cooling the room too strong or exposing the human body to cool breeze for a long time as it is bad for the health.

When you notice something abnormal with the air conditioner (smells like something scorching, poor cooling, etc.), immediately turn off the main switch, the circuit breaker, from the mains to stop the air conditioner, and contact the dealer.

If the air conditioner is continuously operated with something abnormal, it may cause machine failure, electric shock, fire, and so on.

WARNINGS ABOUT MOVEMENT AND REPAIR

When the air conditioner cannot cool or heat a room well, contact the dealer from whom you purchased the air conditioner as refrigerant leakage is considered as the cause. In the case of repair that requires refill of refrigerant, ask service personnel about details of the repair.

The refrigerant used in the air conditioner is harmless.

Generally, the refrigerant does not leak. However, if the refrigerant leaks in a room and a heater or stove burner in the room catches fire, it may generate toxic gas.

When you ask service personnel for repairing refrigerant leakage, confirm that the leakage portion has been completely repaired.

Do not move or repair any unit by yourself.

Since there is high voltage inside the unit, you may get electric shock when removing the cover and main unit.

Whenever the air conditioner needs repair, make sure to ask the dealer to do it. If it is repaired imperfectly, it may cause electric shock or fire.

When moving the air conditioner for re-installing at another place, ask the dealer to do it. If it is imperfectly installed, it may cause electric shock or fire.

– 2 –

2-EN

4-way Air Discharge Cassette Type

Owner’s Manual

CAUTION

TO DISCONNECT THE APPLIANCE FROM THE MAINS SUPPLY

This appliance must be connected to the mains by means of a switch with a contact separation of at least

3 mm.

The installation fuse 40A, 25A or 16A must be used for the power supply line of this air conditioner.

CAUTIONS ABOUT INSTALLATION (Be sure to confirm the following cautions.)

Use an exclusive power circuit for the air conditioner. Use the rated voltage.

Certainly lay the drain hose for perfect draining.

Bad drainage may cause flooding in the house and getting furniture wet.

Make sure to connect the air conditioner to an exclusive power supply of the rated voltage, otherwise the unit may break down or cause a fire.

Do not install the unit in a place where inflammable gas may leak. If inflammable gas accumulates around the unit, it may cause a fire.

CAUTIONS ABOUT OPERATION

• Carefully read this manual before starting the air conditioner.

There are many important things to keep in mind for daily operation.

Do not use this air conditioner for special purpose such as preserving food, precision instruments, art objects, breeding animals, car, vessel, etc.

When the air conditioner is operated with a combustion appliance in the same place, be careful of ventilation to let fresh air enter the room.

Poor ventilation causes oxygen shortage.

Do not place any combustion appliance in a place where it is directly exposed to the wind of air conditioner, otherwise it may cause imperfect combustion.

When the air conditioner is used in a closed room, be careful of sufficient ventilation of the room. Poor ventilation causes oxygen shortage.

Do not touch any switches with wet finger, otherwise you may get an electric shock.

If the air conditioner won’t be used for a considerably long time, turn off the main switch or the circuit breaker, for safety.

Do not put anything on the outdoor unit nor step onto it.

If you do so, it may not only topple over the unit but also injure yourself.

To make the air conditioner operate in its original performance, operate it within the range of the operating temperature specified in the instructions.

Otherwise it may cause a malfunction, or water leak from the unit.

Prevent any liquid from falling into the remote controller. Do not spill juice, water or any kind of liquid.

3-EN

– 3 –

Toshiba RAV-SM804UT-E, RAV-SM1104UT-E, RAV-SM1404UT-E, RAV-SM1604UT-E, RAV-SM564UT-E User Manual

4-way Air Discharge Cassette Type

Owner’s Manual

2 PARTS NAME

Indoor unit

Knob

Earth screw

Knob to open/close the

Provided in the electric parts box.

suction port.

 

 

Discharge louver

 

 

of discharge port

 

 

Change the direction of the air

 

 

to be discharged according to

 

Air filter

cool/heat mode.

 

 

 

 

 

 

Removes dust or trash.

Suction air port

 

 

(Provided on the suction port.)

 

 

 

The air in the room is sucked in

 

 

from this port.

 

 

 

 

Separate sold part

EN

 

Remote controller

 

 

Projection

 

 

 

 

of air filter

 

 

 

 

 

TIMER SET

FAN

MODE

 

 

TIME

SAVE

VENT

 

 

FILTER

SWING/FIX

UNIT LOUVER

 

 

RESET TEST SET CL

 

Outdoor unit

Air inlet (Side and rear)

Fixing leg

Panel

There is an earth screw, valves, and electric parts inside.

Air outlet

Piping panel

Wiring hole

Refrigerant pipe outlet

– 4 –

4-EN

4-way Air Discharge Cassette Type

Owner’s Manual

3 PARTS NAME OF REMOTE CONTROLLER

This remote controller can control the operation of up to 8 indoor units.

Display section

In the display example, all indicators are displayed for the explanation.

In reality only, the selected contents are indicated.

When turning on the leak breaker at the first time, flashes on the display part of the remote controller.

While this display is flashing, the model is being automatically confirmed.

Accordingly, wait for a while after display has disappeared, and then use the remote controller.

TEMP.

 

 

ON / OFF

 

TIMER SET

FAN

MODE

 

TIME

SAVE

VENT

FILTER

SET CL

SWING/FIX

UNIT LOUVER

RESET TEST

Display section

Operation section

 

1

7 8 9

20

161917

 

 

2

 

 

 

 

4

3

 

 

10

 

5

 

 

 

 

6

 

 

11

 

18

15

14

 

13

12

1

2

3

4

5

6

7

SETTING display

Displayed during setup of the timer etc..

Operation mode select display

The selected operation mode is displayed.

CHECK display

Displayed while the protective device works or a trouble occurs.

Timer time display

Time of the timer is displayed.

(When a trouble occurs, the check code is displayed.)

Timer SET IN setup display

When pushing the Timer SET IN button, the display of the timer is selected in order of [OFF] [OFF] repeat OFF timer → [ON] → No display.

Filter display

If “FILTER ” is displayed, clean the air filter.

TEST run display

Displayed during a test run.

8 Louver position display

Displays louver position.

9 SWING display

Displayed during up/down movement of the louver.

10 Set up temperature display

The selected set up temp. is displayed.

11 Remote controller sensor display

Displayed while the sensor of the remote controller is used.

12 PRE-HEAT display

Displayed when the heating operation starts or defrost operation is carried out.

While this indication is displayed, the indoor fan stops.

13 No function display

Displayed if there is no function even if the button is pushed.

5-EN

– 5 –

4-way Air Discharge Cassette Type

Owner’s Manual

 

1

7 8 9

20

161917

 

 

2

 

 

 

 

4

3

 

 

10

 

5

 

 

 

 

6

 

 

11

 

18

15

14

 

13

12

14 Air volume select display

The selected air volume mode is displayed. (AUTO)

(HIGH) (MED.)

(LOW)

15 Louver Number display. (exapmle:01, 02, 03, 04)

16 Dry operation in self cleaning function

Displayed during dry operation in self cleaning function.

17 Power saving mode display

Displayed during capacity saving mode by temporary peak-cut limiting the power current level of the outdoor unit.

18 Louver lock display

Displayed when there is a louver-locked unit in the group (including 1 indoor unit by

1 outdoor unit).

19 Unit Number display

Unit number of the indoor unit selected with the unit select button or abnormal indicate the indoor/outdoor unit.

20 Central control display

Displayed when the air conditioner is used

under the central control in combination with EN a central control remote controller.

In case the remote controller is disabled by the central control system, flashes. The button operation is not accepted.

Even when you push ON/OFF, MODE, or TEMP. button, and the button operation is not accepted.

(Settings made by the remote controller vary with the central control mode. For details, refer to the Owner’s Manual of the central control remote controller.)

– 6 –

6-EN

4-way Air Discharge Cassette Type

Owner’s Manual

Operation section

Push each button to select a desired operation.

The details of the operation needs to be set up once, afterward, the air conditioner can be used by pushing button only.

1 8

12

2

5

3

1

 

button (Air volume select button)

2

Selects the desired air volume mode.

 

button (Timer set button)

 

 

TIMER SET button is used when the timer is set up.

3 button (Check button)

The CHECK button is used for the check operation. During normal operation, do not use this button.

4

button (Ventilation button)

Ventilation button is used when a fan which is sold on the market is connected.

 

 

 

 

 

 

 

If “No function

” is displayed on the

 

 

 

 

 

 

 

 

remote controller when pushing the

5

 

 

 

 

 

 

 

Ventilation button, a fan is not connected.

 

 

 

 

 

 

 

button (Filter reset button)

 

 

 

 

Resets (Erases) “FILTER ” display.

6

 

 

 

 

 

 

 

button (Power save operation)

SAVE button is used for power save operation.

7 button (Swing/Wind direction button)

Selects automatic swing or setting the louver direction.

8 Operation lamp

Lamp is lit during the operation. Lamp is off when stopped.

Although it flashes when operating the protection device or abnormal time.

9

10

4

11

7 6

9 button

When the button is pushed, the operation starts, and it stops by pushing the button again. When the operation has stopped, the operation lamp and all the displays disappear.

10 button (Operation select button)

Selects desired operation mode.

11 button (Unit/Louver select button)

Selects a unit number (left) and louver number (right).

UNIT:

Selects an indoor unit when adjusting wind direction when multiple indoor units are controlled with one remote controller.

LOUVER:

Selects a louver when setting louver lock or wind direction adjustment independently.

12 button (Set up temperature button)

Adjusts the room temperature.

Set the desired set temperature by pushing TEMP. or TEMP. .

OPTION :

Remote controller sensor

Usually the TEMP. sensor of the indoor unit senses the temperature. The temperature on the surrounding of the remote controller can also be sensed.

For details, contact the dealer from which you have purchased the air conditioner.

7-EN

– 7 –

Loading...