Toshiba RAV-SP1104AT-E, RAV-SP1404AT-E, RAV-SP1104ATZG-E, RAV-SM804UT-E, RAV-SM1104UT-E User Manual

...
0 (0)

FILE NO. A07-003

SERVICE MANUAL

AIR-CONDITIONER

INDOOR UNIT

<DIGITAL INVERTER>

RAV-SM564UT-E RAV-SM1104UT-E

OUTDOOR UNIT

<SUPER DIGITAL INVERTER>

RAV-SP1104AT-E RAV-SP1104ATZ-E RAV-SP1104ATZG-E

SPLIT TYPE

RAV-SM804UT-E RAV-SM1404UT-E

RAV-SP1404AT-E RAV-SP1404ATZ-E RAV-SP1404ATZG-E

R410A

PRINTED IN JAPAN, Dec., 2007 ToMo

Adoption of New Refrigerant

This Air Conditioner is a new type which adopts a new refrigerant HFC (R410A) instead of the conventional refrigerant R22 in order to prevent destruction of the ozone layer.

WARNING

Cleaning of the air filter and other parts of the air filter involves dangerous work in high places, so be sure to have a service person do it. Do not attempt it yourself.

The cleaning diagram for the air filter is there for the service person, and not for the customer.

CONTENTS

SAFETY CAUTION ............................................................................................

4

1.

SPECIFICATIONS ......................................................................................

9

 

1-1.

Indoor Unit...........................................................................................................

9

 

1-2.

Outdoor Unit......................................................................................................

21

 

1-3.

Operation Characteristic Curve .......................................................................

22

2.

CONSTRUCTION VIEWS (EXTERNAL VIEWS) ......................................

23

 

2-1.

Indoor Unit.........................................................................................................

23

 

2-2.

Outdoor Unit......................................................................................................

26

3.

SYSTEMATIC REFRIGERATING CYCLE DIAGRAM ..............................

28

 

3-1.

Indoor Unit.........................................................................................................

28

 

3-2.

Outdoor Unit......................................................................................................

29

 

3-3. Systematic Diagram of Refrigerating Cycle ...................................................

29

4.

WIRING DIAGRAM ...................................................................................

30

 

4-1.

Indoor Unit.........................................................................................................

30

 

4-2. Outdoor Unit (Wiring Diagram) ........................................................................

31

5.

SPECIFICATIONS OF ELECTRICAL PARTS ..........................................

32

 

5-1.

Indoor Unit.........................................................................................................

32

 

5-2. Outdoor Unit (Parts Ratings) ...........................................................................

32

 

5-3.

Accessory Separate Sold Parts .......................................................................

32

– 2 –

6. REFRIGERANT R410A ...........................................................................

33

6-1.

Safety During Installation/Servicing ...............................................................

33

6-2. Refrigerant Piping Installation .......................................................................

33

6-3.

Tools ..................................................................................................................

37

6-4.

Recharging of Refrigerant................................................................................

37

6-5.

Brazing of Pipes................................................................................................

38

6-6.

Instructions for Re-use Piping of R22 or R407C ............................................

40

7. INDOOR CONTROL CIRCUIT .................................................................

43

7-1.

Indoor Controller Block Diagram.....................................................................

43

7-2.

Control Specifications ......................................................................................

46

7-3.

Optional Connector Specifications of Indoor P.C. Board ..............................

58

7-4.

Indoor Print Circuit Board ................................................................................

59

8.

CIRCUIT CONFIGURATION AND CONTROL SPECIFICATIONS

........... 60

 

8-1.

Outdoor Controls ..............................................................................................

60

 

8-2.

Outline of Main Controls ..................................................................................

61

9.

TROUBLESHOOTING ..............................................................................

66

 

9-1.

Summary of Troubleshooting...........................................................................

66

 

9-2.

Troubleshooting ................................................................................................

68

10.

REPLACEMENT OF SERVICE P.C. BOARD ...........................................

99

 

10-1.

Indoort Unit .......................................................................................................

99

 

10-2.

Outdoor Unit....................................................................................................

104

11.

SETUP AT LOCAL SITE AND OTHERS ................................................

105

 

11-1.

Indoor Unit.......................................................................................................

105

 

11-2.

Setup at Local Site / Others ...........................................................................

116

 

11-3.

How to Set up Central Control Address Number .........................................

118

 

11-4.

Outdoor Unit....................................................................................................

122

12.

ADDRESS SETUP..................................................................................

129

 

12-1.

Address Setup ................................................................................................

129

 

12-2.

Address Setup & Group Control....................................................................

130

 

12-3.

Address Setup ................................................................................................

132

13.

DETACHMENTS .....................................................................................

135

 

13-1.

Indoor Unit......................................................................................................

135

 

13-2.

Outdoor Unit....................................................................................................

145

14.

EXPLODED VIEWS AND PARTS LIST ..................................................

153

 

14-1.

Indoor Unit.......................................................................................................

153

 

14-2.

Outdoor Unit....................................................................................................

158

– 3 –

SAFETY CAUTION

The important contents concerned to the safety are described on the product itself and on this Service Manual.

Please read this Service Manual after understanding the described items thoroughly in the following contents (Indications/Illustrated marks), and keep them.

[Explanation of indications]

Indication

Explanation

 

 

DANGER

Indicates contents assumed that an imminent danger causing a death or serious injury of

the repair engineers and the third parties when an incorrect work has been executed.

Indicates possibilities assumed that a danger causing a death or serious injury of the WARNING repair engineers, the third parties, and the users due to troubles of the product after work

when an incorrect work has been executed.

Indicates contents assumed that an injury or property damage ( ) may be caused on the CAUTION repair engineers, the third parties, and the users due to troubles of the product after work

when an incorrect work has been executed.

Property damage : Enlarged damage concerned to property, furniture, and domestic animal/pet

[Explanation of illustrated marks]

Mark

Explanation

Indicates prohibited items (Forbidden items to do)

The sentences near an illustrated mark describe the concrete prohibited contents.

Indicates mandatory items (Compulsory items to do)

The sentences near an illustrated mark describe the concrete mandatory contents.

Indicates cautions (Including danger/warning)

The sentences or illustration near or in an illustrated mark describe the concrete cautious contents.

[Confirmation of warning label on the main unit]

Confirm that labels are indicated on the specified positions (Refer to the Parts disassembly diagram (Outdoor unit).)

If removing the label during parts replace, stick it as the original.

DANGER

Turn “OFF” the breaker before removing the front panel and cabinet, otherwise an electric shock is caused by high voltage resulted in a death or injury.

During operation, a high voltage with 400V or higher of circuit ( ) at secondary circuit of the high-voltage transformer is applied.

If touching a high voltage with the naked hands or body, an electric shock is caused even if using an Turn off breaker. electric insulator.

: For details, refer to the electric wiring diagram.

When removing the front panel or cabinet, execute short-circuit and discharge between highvoltage capacitor terminals.

If discharge is not executed, an electric shock is caused by high voltage resulted in a death or injury.

Execute discharge After turning off the breaker, high voltage also keeps to apply to the high-voltage capacitor. between terminals.

Do not turn on the breaker under condition that the front panel and cabinet are removed.

An electric shock is caused by high voltage resulted in a death or injury.

Prohibition

– 4 –

WARNING

 

Before troubleshooting or repair work, check the earth wire is connected to the earth

 

terminals of the main unit, otherwise an electric shock is caused when a leak occurs.

Check earth wires.

If the earth wire is not correctly connected, contact an electric engineer for rework.

 

 

 

 

Do not modify the products.

 

Do not also disassemble or modify the parts. It may cause a fire, electric shock or injury.

Prohibition of modification.

 

 

 

 

For spare parts, use those specified ( ).

 

If unspecified parts are used, a fire or electric shock may be caused.

Use specified parts.

: For details, refer to the parts list.

 

 

 

Before troubleshooting or repair work, do not bring a third party (a child, etc.) except

 

the repair engineers close to the equipment.

Do not bring a child

It causes an injury with tools or disassembled parts.

Please inform the users so that the third party (a child, etc.) does not approach the equipment.

close to the equipment.

 

 

 

Connect the cut-off lead wires with crimp contact, etc, put the closed end side upward

 

and then apply a water-cut method, otherwise a leak or production of fire is caused at

 

the users’ side.

Insulating measures

 

When repairing the refrigerating cycle, take the following measures.

1)Be attentive to fire around the cycle. When using a gas stove, etc, be sure to put out fire before work; otherwise the oil mixed with refrigerant gas may catch fire.

 

2) Do not use a welder in the closed room.

No fire

When using it without ventilation, carbon monoxide poisoning may be caused.

3)Do not bring inflammables close to the refrigerant cycle, otherwise fire of the welder may catch the inflammables.

Check the used refrigerant name and use tools and materials of the parts which match with it.

For the products which use R410A refrigerant, the refrigerant name is indicated at a position on the outdoor unit where is easy to see. To prevent miss-charging, the route of the service port is changed from one of the former R22.

 

For an air conditioner which uses R410A, never use other refrigerant than R410A.

 

For an air conditioner which uses other refrigerant (R22, etc.), never use R410A.

 

If different types of refrigerant are mixed, abnormal high pressure generates in the

 

refrigerating cycle and an injury due to breakage may be caused.

 

Do not charge refrigerant additionally.

 

If charging refrigerant additionally when refrigerant gas leaks, the refrigerant composition in

 

the refrigerating cycle changes resulted in change of air conditioner characteristics or

 

refrigerant over the specified standard amount is charged and an abnormal high pressure is

 

applied to the inside of the refrigerating cycle resulted in cause of breakage or injury.

 

Therefore if the refrigerant gas leaks, recover the refrigerant in the air conditioner, execute

Refrigerant

vacuuming, and then newly recharge the specified amount of liquid refrigerant.

 

In this time, never charge the refrigerant over the specified amount.

 

When recharging the refrigerant in the refrigerating cycle, do not mix the refrigerant

 

or air other than R410A into the specified refrigerant.

 

If air or others is mixed with the refrigerant, abnormal high pressure generates in the

 

refrigerating cycle resulted in cause of injury due to breakage.

 

After installation work, check the refrigerant gas does not leak.

 

If the refrigerant gas leaks in the room, poisonous gas generates when gas touches to fire

 

such as fan heater, stove or cocking stove though the refrigerant gas itself is innocuous.

 

Never recover the refrigerant into the outdoor unit.

 

When the equipment is moved or repaired, be sure to recover the refrigerant with recovering

 

device. The refrigerant cannot be recovered in the outdoor unit; otherwise a serious accident

 

such as breakage or injury is caused.

 

 

 

After repair work, surely assemble the disassembled parts, and connect and lead the

 

removed wires as before. Perform the work so that the cabinet or panel does not

 

catch the inner wires.

Assembly/Cabling

If incorrect assembly or incorrect wire connection was done, a disaster such as a leak or fire

is caused at user’s side.

 

– 5 –

WARNING

 

After the work has finished, be sure to use an insulation tester set (500V Megger) to

 

check the resistance is 2Mor more between the charge section and the non-charge

 

metal section (Earth position).

Insulator check

If the resistance value is low, a disaster such as a leak or electric shock is caused at user’s

side.

 

When the refrigerant gas leaks during work, execute ventilation.

 

If the refrigerant gas touches to a fire, poisonous gas generates.

 

A case of leakage of the refrigerant and the closed room full with gas is dangerous because

Ventilation

a shortage of oxygen occurs. Be sure to execute ventilation.

When checking the circuit inevitably under condition of the power-ON, use rubber gloves and others not to touch to the charging section.

If touching to the charging section, an electric shock may be caused.

Be attentive to electric shock

When the refrigerant gas leaks, find up the leaked position and repair it surely.

If the leaked position cannot be found up and the repair work is interrupted, pump-down and tighten the service valve, otherwise the refrigerant gas may leak into the room.

The poisonous gas generates when gas touches to fire such as fan heater, stove or cocking stove though the refrigerant gas itself is innocuous.

 

When installing equipment which includes a large amount of charged refrigerant such

 

as a multi air conditioner in a sub-room, it is necessary that the density does not the

Compulsion

limit even if the refrigerant leaks.

If the refrigerant leaks and exceeds the limit density, an accident of shortage of oxygen is caused.

 

For the installation/moving/reinstallation work, follow to the Installation Manual.

 

If an incorrect installation is done, a trouble of the refrigerating cycle, water leak, electric

 

shock or fire is caused.

 

 

 

After repair work has finished, check there is no trouble.

 

If check is not executed, a fire, electric shock or injury may be caused.

 

For a check, turn off the power breaker.

 

 

Check after rerair

After repair work (installation of front panel and cabinet) has finished, execute a test

run to check there is no generation of smoke or abnormal sound.

 

 

If check is not executed, a fire or an electric shock is caused.

 

Before test run, install the front panel and cabinet.

 

 

 

Check the following items after reinstallation.

 

1) The earth wire is correctly connected.

 

2) The power cord is not caught in the product.

Check after reinstallation

3) There is no inclination or unsteadiness and the installation is stable.

If check is not executed, a fire, an electric shock or an injury is caused.

 

CAUTION

 

Be sure to put on gloves ( ) during repair work.

 

If not putting on gloves, an injury may be caused with the parts, etc.

Put on gloves

( ) Heavy gloves such as work gloves

 

 

 

 

When the power was turned on, start to work after the equipment has been

 

sufficiently cooled.

Cooling check

As temperature of the compressor pipes and others became high due to cooling/heating

operation, a burn may be caused.

 

 

– 6 –

• New Refrigerant (R410A)

This air conditioner adopts a new HFC type refrigerant (R410A) which does not deplete the ozone layer.

1. Safety Caution Concerned to New Refrigerant

The pressure of R410A is high 1.6 times of that of the former refrigerant (R22).

Accompanied with change of refrigerant, the refrigerating oil has been also changed.

Therefore, be sure that water, dust, the former refrigerant or the former refrigerating oil is not mixed into the refrigerating cycle of the air conditioner with new refrigerant during installation work or service work.

If an incorrect work or incorrect service is performed, there is a possibility to cause a serious accident.

Use the tools and materials exclusive to R410A to purpose a safe work.

2.Cautions on Installation/Service

1)Do not mix the other refrigerant or refrigerating oil.

For the tools exclusive to R410A, shapes of all the joints including the service port differ from those of the former refrigerant in order to prevent mixture of them.

2)As the use pressure of the new refrigerant is high, use material thickness of the pipe and tools which are specified for R410A.

3)In the installation time, use clean pipe materials and work with great attention so that water and others do not mix in because pipes are affected by impurities such as water, oxide scales, oil, etc.

Use the clean pipes.

Be sure to brazing with flowing nitrogen gas. (Never use gas other than nitrogen gas.)

4)For the earth protection, use a vacuum pump for air purge.

5)R410A refrigerant is azeotropic mixture type refrigerant.

Therefore use liquid type to charge the refrigerant. (If using gas for charging, composition of the refrigerant changes and then characteristics of the air conditioner change.)

3.Pipe Materials

For the refrigerant pipes, copper pipe and joints are mainly used.

It is necessary to select the most appropriate pipes to conform to the standard.

Use clean material in which impurities adhere inside of pipe or joint to a minimum.

1) Copper pipe

<Piping>

The pipe thickness, flare finishing size, flare nut and others differ according to a refrigerant type.

When us#ing a long copper pipe for R410A, it is recommended to select “Copper or copper-base pipe without seam” and one with bonded oil amount 40mg/10m or less.

Also do not use crushed, deformed, discolored (especially inside) pipes. (Impurities cause clogging of expansion valves and capillary tubes.)

<Flare nut>

Use the flare nuts which are attached to the air conditioner unit.

2)Joint

The flare joint and socket joint are used for joints of the copper pipe.

The joints are rarely used for installation of the air conditioner. However clear impurities when using them.

7 –

4.Tools

1.Required Tools for R410A

Mixing of different types of oil may cause a trouble such as generation of sludge, clogging of capillary, etc. Accordingly, the tools to be used are classified into the following three types.

1)Tools exclusive for R410A (Those which cannot be used for conventional refrigerant (R22))

2)Tools exclusive for R410A, but can be also used for conventional refrigerant (R22)

3)Tools commonly used for R410A and for conventional refrigerant (R22)

The table below shows the tools exclusive for R410A and their interchangeability.

Tools exclusive for R410A (The following tools for R410A are required.)

Tools whose specifications are changed for R410A and their interchangeability

 

 

 

R410A

Conventional air

 

 

 

air conditioner installation

conditioner installation

No.

Used tool

Usage

 

 

 

Existence of

Whether conven-

Whether conventional

 

 

 

 

 

 

new equipment

tional equipment

equipment can be used

 

 

 

for R410A

can be used

 

 

 

 

 

 

 

 

 

 

Flare tool

Pipe flaring

Yes

*(Note)

Yes

 

 

 

 

 

 

Copper pipe gauge for

Flaring by conventional

Yes

*(Note)

*(Note)

adjusting projection margin

flare tool

 

 

 

 

 

 

ƒ

Torque wrench

Connection of flare nut

Yes

No

No

 

 

 

 

 

 

Gauge manifold

Evacuating, refrigerant

Yes

No

No

 

 

Charge hose

charge, run check, etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

Vacuum pump adapter

Vacuum evacuating

Yes

No

Yes

 

 

 

 

 

 

Electronic balance for

Refrigerant charge

Yes

Yes

Yes

refrigerant charging

 

 

 

 

 

 

ˆ

Refrigerant cylinder

Refrigerant charge

Yes

No

No

 

 

 

 

 

 

Leakage detector

Gas leakage check

Yes

No

Yes

 

 

 

 

 

 

Š

Charging cylinder

Refrigerant charge

No

No

No

 

 

 

 

 

 

(Note) When flaring is carried out for R410A using the conventional flare tools, adjustment of projection margin is necessary. For this adjustment, a copper pipe gauge, etc. are necessary.

General tools (Conventional tools can be used.)

In addition to the above exclusive tools, the following equipments which serve also for R22 are necessary as the general tools.

1)Vacuum pump

Use vacuum pump by

attaching vacuum pump adapter.

2)Torque wrench

3)Pipe cutter

4)Reamer

5)Pipe bender

6)Level vial

7)Screwdriver (+, –)

8)Spanner or Monkey wrench

9)Hole core drill

10)Hexagon wrench (Opposite side 4mm)

11)Tape measure

12)Metal saw

Also prepare the following equipments for other installation method and run check.

1)

Clamp meter

3)

IInsulation resistance tester (Megger)

2)

Thermometer

4)

Electroscope

– 8 –

1. SPECIFICATIONS

1-1. Indoor Unit

1-1-1. 4-Way Air Discharge Cassette Type

<Single type>

Model

 

Indoor unit

 

RAV-SM

564UT-E

 

804UT-E

1104UT-E

1404UT-E

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

RAV-SP

562AT(Z)(ZG)-E

 

802AT(Z)(ZG)-E

1104AT(Z)(ZG)-E

1404AT(Z)(ZG)-E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling capacity

 

 

(kW)

5.3

 

7.1

10.0

12.5

 

 

 

 

 

 

 

 

 

Heating capacity

 

 

(kW)

5.6

 

8.0

11.2

14.0

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Running current

(A)

7.17 – 6.57

 

8.95 – 8.21

10.36 – 9.49

14.66 – 13.44

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption(kW)

1.53

 

1.93

2.21

3.16

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Power factor

(%)

97

 

98

97

98

 

 

 

 

 

 

 

 

 

 

 

EER

 

3.46

 

3.68

4.52

3.96

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

A

 

A

A

A

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy rating

 

 

Electrical

 

 

 

 

 

 

 

 

 

 

 

Running current

(A)

5.62 – 5.15

 

9.42 – 8.63

10.96 – 10.05

14.89 – 13.65

characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption(kW)

1.20

 

2.03

2.34

3.21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

Power factor

(%)

97

 

98

97

98

 

 

 

 

 

 

 

 

 

 

 

COP

 

4.67

 

3.94

4.79

4.36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

A

 

A

A

A

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy rating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum current

 

 

15.33

 

15.33

20.50

20.50

 

 

 

 

 

 

 

 

 

 

 

 

Main unit

 

 

 

 

Zinc hot dipping steel plate

 

 

 

 

 

 

 

 

 

 

 

Appearance

 

Ceiling panel

Model

 

 

RBC-U31PG (W)-E, RBC-U31PG (WS)-E

 

 

 

 

 

 

 

 

 

 

 

(Sold separately)

Panel color

 

W: Moon-white (2.5GY 9.0/0.5), WS: Stripe-white (2.5GY 9.0/0.5, (Gray: 8B 3/0.3))

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

(mm)

256

 

256

319

319

 

 

 

 

 

 

 

 

 

 

 

 

Main unit

Width

(mm)

840

 

840

840

840

 

 

 

 

 

 

 

 

 

 

Outer

 

 

Depth

(mm)

840

 

840

840

840

 

 

 

 

 

 

 

 

 

dimension

 

 

Height

(mm)

30

 

30

30

30

 

 

 

 

 

 

Ceiling panel

 

 

 

 

 

 

 

 

 

Width

(mm)

950

 

950

950

950

 

 

(Sold separately)

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

(mm)

950

 

950

950

950

 

 

 

 

 

 

 

 

 

 

Total weight

 

Main unit

 

(kg)

20

 

20

24

24

 

 

 

 

 

 

 

 

 

 

Ceiling panel (Sold separately)

(kg)

4.2

 

4.2

4.2

4.2

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat exchanger

 

 

 

 

 

Finned tube

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

Turbo fan

 

Turbo fan

Turbo fan

Turbo fan

 

 

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow

H/M/L

(m³/min.)

17.5/14.5/13.0

 

20.5/16.0/13.5

33.5/24.0/19.5

35.0/24.0/20.5

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

14

 

20

68

72

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

 

 

Standard filter attached (Long life filter)

 

 

 

 

 

 

 

 

Controller (Sold separately)

 

 

 

 

RBC-AMT32E, AS21E2, AX31U (W)-E

 

 

 

 

 

 

 

 

 

Sound pressure level

H/M/L

(dB•A)

32 / 29 / 28

 

35 / 31 / 28

43 / 38 / 33

44 / 38 / 34

 

 

 

 

 

 

 

 

Sound power level

H/M/L

(dB•A)

47 / 44 / 43

 

50 / 46 / 43

58 / 53 / 48

59 / 53 / 49

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas side

(mm)

12.7

 

15.9

15.9

15.9

 

 

 

 

 

 

 

 

 

Connecting pipe

 

Liquid side

(mm)

6.4

 

9.5

9.5

9.5

 

 

 

 

 

 

 

 

 

 

 

 

 

Drain port

(mm)

 

 

VP25

 

 

 

 

 

 

 

 

 

 

 

: IEC standard, : AS standard

– 9 –

Model

 

Indoor unit

 

RAV-

SM564UT-E

 

SM804UT-E

SM1104UT-E

 

SM1404UT-E

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

RAV-

SM563AT-E

 

SM803AT-E

SM1103AT-E

 

SM1403AT-E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling capacity

 

 

(kW)

5.3

 

6.7

10.0

 

12.0

 

 

 

 

 

 

 

 

 

 

Heating capacity

 

 

(kW)

5.6

 

8.0

11.2

 

14.0

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Running current

(A)

7.89 – 7.24

 

9.97 – 9.12

14.61 – 13.40

 

17.62 – 16.14

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption(kW)

1.65

 

2.09

3.11

 

3.74

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Power factor

(%)

95

 

95

97

 

96

 

 

 

 

 

 

 

 

 

 

 

 

EER

 

3.21

 

3.21

3.22

 

3.21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

A

 

A

A

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy rating

 

 

 

Electrical

 

 

 

 

 

 

 

 

 

 

 

 

Running current

(A)

6.89 – 6.32

 

10.83 – 9.90

13.38 – 12.38

 

17.88 – 15.87

characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption(kW)

1.44

 

2.21

2.93

 

3.80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

Power factor

(%)

95

 

93

99

 

98

 

 

 

 

 

 

 

 

 

 

 

 

COP

 

3.89

 

3.62

3.82

 

3.68

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

A

 

A

A

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy rating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum current

 

 

15.33

 

15.33

20.50

 

20.50

 

 

 

 

 

 

 

 

 

 

 

 

 

Main unit

 

 

 

 

Zinc hot dipping steel plate

 

 

 

 

 

 

 

 

 

 

 

 

Appearance

 

Ceiling panel

Model

 

 

RBC-U31PG (W)-E, RBC-U31PG (WS)-E

 

 

 

 

 

 

 

 

 

 

 

 

 

(Sold separately)

Panel color

 

W: Moon-white (2.5GY 9.0/0.5), WS: Stripe-white (2.5GY 9.0/0.5, (Gray: 8B 3/0.3))

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

(mm)

256

 

256

319

 

319

 

 

 

 

 

 

 

 

 

 

 

 

 

Main unit

Width

(mm)

840

 

840

840

 

840

 

 

 

 

 

 

 

 

 

 

 

Outer

 

 

Depth

(mm)

840

 

840

840

 

840

 

 

 

 

 

 

 

 

 

 

dimension

 

 

Height

(mm)

30

 

30

30

 

30

 

 

 

 

 

 

 

Ceiling panel

 

 

 

 

 

 

 

 

 

 

Width

(mm)

950

 

950

950

 

950

 

 

(Sold separately)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

(mm)

950

 

950

950

 

950

 

 

 

 

 

 

 

 

 

 

 

Total weight

 

Main unit

 

(kg)

24

 

24

24

 

24

 

 

 

 

 

 

 

 

 

 

 

Ceiling panel (Sold separately)

(kg)

4.2

 

4.2

4.2

 

4.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat exchanger

 

 

 

 

 

Finned tube

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

Turbo fan

 

Turbo fan

Turbo fan

 

Turbo fan

 

 

 

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow

H/M/L

(m³/min.)

17.5/14.5/13.0

 

20.5/16.0/13.5

33.5/24.0/19.5

 

35.0/24.0/20.5

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

14

 

20

68

 

72

 

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

 

 

Standard filter attached (Long life filter)

 

 

 

 

 

 

 

 

Controller (Sold separately)

 

 

 

 

RBC-AMT32E, AS21E2, AX31U (W)-E

 

 

 

 

 

 

 

 

 

 

Sound pressure level

H/M/L

(dB•A)

32 / 29 / 28

 

35 / 31 / 28

43 / 38 / 33

 

44 / 38 / 34

 

 

 

 

 

 

 

 

 

Sound power level

H/M/L

(dB•A)

47 / 44 / 43

 

50 / 46 / 43

58 / 53 / 48

 

59 / 53 / 49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas side

(mm)

12.7

 

15.9

15.9

 

15.9

 

 

 

 

 

 

 

 

 

 

Connecting pipe

 

Liquid side

(mm)

6.4

 

9.5

9.5

 

9.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drain port

(mm)

 

 

VP25

 

 

 

 

 

 

 

 

 

 

 

 

: IEC standard, : AS standard

– 10 –

<Twin type>

 

 

Indoor unit 1

 

RAV-

 

SM564UT-E

SM804UT-E

 

 

 

 

 

 

 

 

Model

 

Indoor unit 2

 

RAV-

 

SM564UT-E

SM804UT-E

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

RAV-

 

SP1104AT(Z)(ZG)-E

SP1404AT(Z)(ZG)-E

 

 

 

 

 

 

 

 

Cooling capacity

 

 

(kW)

 

10.0

12.5

 

 

 

 

 

 

 

 

Heating capacity

 

 

(kW)

 

11.2

14.0

 

 

 

 

 

 

 

 

 

 

 

 

Indoor unit

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

 

Running current

(A)

 

10.36 – 9.49

14.66 – 13.44

 

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

 

2.21

3.16

 

 

 

 

 

 

 

 

 

 

Cooling

Power factor

(%)

 

97

98

 

 

 

 

 

 

 

 

 

 

 

EER

 

 

4.52

3.96

 

 

 

 

 

 

 

Electrical

 

 

Energy efficiency class

 

A

A

 

 

 

 

 

 

 

characteristics

 

 

Running current

(A)

 

10.96 – 10.05

14.89 – 13.65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

 

2.34

3.21

 

 

 

 

 

 

 

 

 

 

Heating

Power factor

(%)

 

97

98

 

 

 

 

 

 

 

 

 

 

 

COP

 

 

4.79

4.36

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

 

A

A

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

Turbo fan

Turbo fan

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow

H/M/L

(m³/min.)

 

17.5 / 14.5 / 13.0

20.5 / 16.0 / 13.5

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

 

14

20

 

 

 

 

 

 

 

Sound pressure level

H/M/L

(dB•A)

 

32 / 29 / 28

35 / 31 / 28

 

 

 

 

 

 

 

Sound power level

H/M/L

(dB•A)

 

47 / 44 / 43

50 / 46 / 43

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

Standard length

 

(m)

 

7.5

7.5

 

 

 

 

 

 

 

 

 

 

Min. length

 

(m)

 

3

3

 

 

 

 

 

 

 

 

Outer

 

Max. total length

 

(m)

 

50

50

 

 

 

 

 

 

 

dimension

 

Over 30m

 

 

 

40g/m (31m to 50m)

40g/m (31m to 50m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

Outdoor lower

(m)

 

30

30

 

 

 

 

 

 

 

 

 

difference

Outdoor higher

(m)

 

30

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

Propeller fan

Propeller fan

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow volume

(m³/min.)

 

101

103

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

 

100 + 100

100 + 100

 

 

 

 

 

 

 

 

 

 

Gas side

Main

(mm)

 

15.9

15.9

 

 

 

 

 

 

 

Connecting

 

Sub

(mm)

 

12.7

15.9

 

 

 

 

 

 

 

 

 

 

pipe

 

Liquid side

Main

(mm)

 

9.5

9.5

 

 

 

 

 

 

 

 

 

 

 

 

Sub

(mm)

 

6.4

9.5

 

 

 

 

 

 

 

 

 

 

 

Sound pressure level

Cooling/Heating

(dB•A)

 

49 / 50

51 / 52

 

 

 

 

 

 

 

Sound power level

Cooling/Heating

(dB•A)

 

66 / 67

68 / 69

 

 

 

 

 

 

 

 

: IEC standard

– 11 –

 

 

Indoor unit 1

 

RAV-

 

SM564UT-E

SM804UT-E

 

 

 

 

 

 

 

 

Model

 

Indoor unit 2

 

RAV-

 

SM564UT-E

SM804UT-E

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

RAV-

 

SM1103AT-E

SM1403AT-E

 

 

 

 

 

 

 

 

Cooling capacity

 

 

(kW)

 

10.0

12.5

 

 

 

 

 

 

 

 

Heating capacity

 

 

(kW)

 

11.2

14.0

 

 

 

 

 

 

 

 

 

 

 

 

Indoor unit

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

 

Running current

(A)

 

14.40 – 13.20

20.57 – 18.97

 

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

 

3.11

4.09

 

 

 

 

 

 

 

 

 

 

Cooling

Power factor

(%)

 

98

95

 

 

 

 

 

 

 

 

 

 

 

EER

 

 

3.22

3.06

 

 

 

 

 

 

 

Electrical

 

 

Energy efficiency class

 

A

B

 

 

 

 

 

 

 

characteristics

 

 

Running current

(A)

 

14.40 – 13.20

17.74– 16.08

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

 

2.93

4.00

 

 

 

 

 

 

 

 

 

 

Heating

Power factor

(%)

 

98

99

 

 

 

 

 

 

 

 

 

 

 

COP

 

 

3.82

3.50

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

 

A

B

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

Turbo fan

Turbo fan

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow

H/M/L

(m³/min.)

 

17.5 / 14.5 / 13.0

20.5 / 16.0 / 13.5

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

 

14

20

 

 

 

 

 

 

 

Sound pressure level

H/M/L

(dB•A)

 

32 / 29 / 28

35 / 31 / 28

 

 

 

 

 

 

 

Sound power level

H/M/L

(dB•A)

 

47 / 44 / 43

50 / 46 / 43

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

Standard length

 

(m)

 

7.5

7.5

 

 

 

 

 

 

 

 

 

 

Min. length

 

(m)

 

5

5

 

 

 

 

 

 

 

 

Outer

 

Max. total length

 

(m)

 

50

50

 

 

 

 

 

 

 

dimension

 

Over 30m

 

 

 

40g/m (31m to 50m)

40g/m (31m to 50m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

Outdoor lower

(m)

 

30

30

 

 

 

 

 

 

 

 

 

difference

Outdoor higher

(m)

 

30

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

Propeller fan

Propeller fan

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow volume

(m³/min.)

 

75

75

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

 

63

100

 

 

 

 

 

 

 

 

 

 

Gas side

Main

(mm)

 

15.9

15.9

 

 

 

 

 

 

 

Connecting

 

Sub

(mm)

 

12.7

15.9

 

 

 

 

 

 

 

 

 

 

pipe

 

Liquid side

Main

(mm)

 

9.5

9.5

 

 

 

 

 

 

 

 

 

 

 

 

Sub

(mm)

 

6.4

9.5

 

 

 

 

 

 

 

 

 

 

 

Sound pressure level

Cooling/Heating

(dB•A)

 

53 / 54

54 / 54

 

 

 

 

 

 

 

Sound power level

Cooling/Heating

(dB•A)

 

70 / 71

71 / 71

 

 

 

 

 

 

 

 

: IEC standard

– 12 –

1-1-2. Concealed Duct Type

<Single type>

Model

 

Indoor unit

 

RAV-SM

562BT-E

802BT-E

 

 

1102BT-E

 

1402BT-E

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

RAV-SP

562AT(Z)(ZG)-E

802AT(Z)(ZG)-E

 

 

1104AT(Z)(ZG)-E

1404AT(Z)(ZG)-E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling capacity

 

 

(kW)

5.0

7.1

 

10.0

 

12.5

 

 

 

 

 

 

 

 

 

 

 

 

Heating capacity

 

 

(kW)

5.6

8.0

 

11.2

 

14.0

 

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Running current

(A)

6.51 – 5.97

9.74 – 8.93

 

 

13.78 – 12.63

 

17.76 – 16.28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption(kW)

1.39

2.10

 

2.94

 

3.83

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Power factor

(%)

97

98

 

97

 

98

 

 

 

 

 

 

 

 

 

 

 

 

 

EER

 

3.60

3.38

 

3.40

 

3.26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

A

A

 

 

A

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy rating

 

 

 

 

Electrical

 

 

 

 

 

 

 

 

 

 

 

 

 

Running current

(A)

7.26 – 6.66

9.74 – 8.93

 

 

12.98 – 11.90

 

15.82 – 14.50

characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption(kW)

1.55

2.41

 

2.77

 

3.41

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

Power factor

(%)

97

94

 

97

 

98

 

 

 

 

 

 

 

 

 

 

 

 

 

COP

 

3.61

3.32

 

4.04

 

4.11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

A

A

 

 

A

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy rating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum current

 

 

15.86

16.30

 

21.73

 

22.13

 

 

 

 

 

 

 

 

 

 

 

 

 

Main unit

 

 

 

Zinc hot dipping steel plate

 

 

 

 

 

 

 

 

 

 

 

 

 

Appearance

 

Ceiling panel

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Sold separately)

Panel color

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

(mm)

320

320

 

320

 

320

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Main unit

Width

(mm)

700

1000

 

1350

 

1350

 

 

 

 

 

 

 

 

 

 

 

 

Outer

 

 

Depth

(mm)

800

800

 

800

 

800

 

 

 

 

 

 

 

 

 

 

 

dimension

 

 

Height

(mm)

 

 

 

 

 

 

 

 

 

 

 

Ceiling panel

 

 

 

 

 

 

 

 

 

 

 

Width

(mm)

 

 

 

 

 

(Sold separately)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total weight

 

Main unit

 

(kg)

30

39

 

54

 

54

 

 

 

 

 

 

 

 

 

 

 

 

Ceiling panel (Sold separately)

(kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat exchanger

 

 

 

 

Finned tube

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

Centrifugal

Centrifugal

 

 

Centrifugal

 

Centrifugal

 

 

 

 

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow

H/M/L

(m³/min.)

13.0/11.9/9.8

19.0/16.2/13.3

 

27.0/23.0/18.9

 

33.0/28.0/23.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

120

120

 

120

 

120

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UFM11BFCE

 

 

UFM21BFCE

Air filter

 

 

TCB-

UFM21BE

UFM31BE

 

 

UFM41BE

 

 

UFM61BE

UFM51BFCE

 

 

UFM61BFCE

 

 

 

 

 

 

 

 

 

 

 

 

 

UFM71BE

 

 

UFM81BE

 

 

 

 

 

 

 

 

 

 

Controller (Sold separately)

 

 

 

RBC-AMT31E, AS21E2, AX21U(W)-E2

 

 

 

 

 

 

 

 

 

 

 

 

Sound pressure level

H/M/L

(dB•A)

40 / 37 / 33

40 / 37 / 34

 

42 / 39 / 36

 

44 / 41 / 38

 

 

 

 

 

 

 

 

 

 

 

Sound power level

H/M/L

(dB•A)

55 / 52 / 48

55 / 52 / 49

 

57 / 54 / 51

 

59 / 56 / 53

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas side

(mm)

12.7

15.9

 

15.9

 

15.9

 

 

 

 

 

 

 

 

 

 

 

 

Connecting pipe

 

Liquid side

(mm)

6.4

9.5

 

9.5

 

9.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drain port

(mm)

 

VP25

 

 

 

 

 

 

 

 

 

 

 

 

 

: IEC standard, : AS standard

– 13 –

<Twin type>

 

 

Indoor unit 1

 

RAV-

 

SM562BT-E

SM802BT-E

 

 

 

 

 

 

 

 

Model

 

Indoor unit 2

 

RAV-

 

SM562BT-E

SM802BT-E

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

RAV-

 

SP1104AT(Z)(ZG)-E

SP1404AT(Z)(ZG)-E

 

 

 

 

 

 

 

 

Cooling capacity

 

 

(kW)

 

10.0

12.5

 

 

 

 

 

 

 

 

Heating capacity

 

 

(kW)

 

11.2

14.0

 

 

 

 

 

 

 

 

 

 

 

 

Indoor unit

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

 

Running current

(A)

 

13.78 – 12.63

17.76 – 16.28

 

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

 

2.94

3.83

 

 

 

 

 

 

 

 

 

 

Cooling

Power factor

(%)

 

97

98

 

 

 

 

 

 

 

 

 

 

 

EER

 

 

3.4

3.26

 

 

 

 

 

 

 

Electrical

 

 

Energy efficiency class

 

A

A

 

 

 

 

 

 

 

characteristics

 

 

Running current

(A)

 

12.98 – 11.90

15.82 – 14.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

 

2.77

3.41

 

 

 

 

 

 

 

 

 

 

Heating

Power factor

(%)

 

97

98

 

 

 

 

 

 

 

 

 

 

 

COP

 

 

4.04

4.11

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

 

A

A

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

Centrifugal

Centrifugal

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow

H/M/L

(m³/min.)

 

13.0 / 11.9 / 9.8

19.0 / 16.2 / 13.3

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

 

120

120

 

 

 

 

 

 

 

Sound pressure level

H/M/L

(dB•A)

 

40 / 37 / 33

40 / 37 / 34

 

 

 

 

 

 

 

Sound power level

H/M/L

(dB•A)

 

55 / 52 / 48

55 / 52 / 49

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

Standard length

 

(m)

 

7.5

7.5

 

 

 

 

 

 

 

 

 

 

Min. length

 

(m)

 

3

3

 

 

 

 

 

 

 

 

Outer

 

Max. total length

 

(m)

 

50

50

 

 

 

 

 

 

 

dimension

 

Over 30m

 

 

 

40g/m (31m to 50m)

40g/m (31m to 50m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

Outdoor lower

(m)

 

30

30

 

 

 

 

 

 

 

 

 

difference

Outdoor higher

(m)

 

30

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

Propeller fan

Propeller fan

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow volume

(m³/min.)

 

101

103

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

 

100 + 100

100 + 100

 

 

 

 

 

 

 

 

 

 

Gas side

Main

(mm)

 

15.9

15.9

 

 

 

 

 

 

 

Connecting

 

Sub

(mm)

 

12.7

15.9

 

 

 

 

 

 

 

 

 

 

pipe

 

Liquid side

Main

(mm)

 

9.5

9.5

 

 

 

 

 

 

 

 

 

 

 

 

Sub

(mm)

 

6.4

9.5

 

 

 

 

 

 

 

 

 

 

 

Sound pressure level

Cooling/Heating

(dB•A)

 

49 / 50

51 / 52

 

 

 

 

 

 

 

Sound power level

Cooling/Heating

(dB•A)

 

66 / 67

68 / 69

 

 

 

 

 

 

 

 

: IEC standard

– 14 –

1-1-3. Under Ceiling Type

<Single type>

Model

 

Indoor unit

 

RAV-SM

562CT-E

802CT-E

 

1102CT-E

1402CT-E

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

RAV-SP

562AT(Z)(ZG)-E

802AT(Z)(ZG)-E

1104AT(Z)(ZG)-E

1404AT(Z)(ZG)-E

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling capacity

 

 

(kW)

5.0

7.1

 

10.0

12.5

 

 

 

 

 

 

 

 

 

 

Heating capacity

 

 

(kW)

5.6

8.0

 

11.2

14.0

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Running current

(A)

6.61 – 6.06

9.47 – 8.93

 

12.51 – 11.47

17.30 – 15.86

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption(kW)

1.41

2.1

 

2.67

3.73

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Power factor

(%)

97

98

 

97

98

 

 

 

 

 

 

 

 

 

 

 

EER

 

3.55

3.38

 

3.75

3.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

A

A

 

A

A

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy rating

 

 

 

 

 

 

Electrical

 

 

 

 

 

 

 

 

 

 

Running current

(A)

7.03 – 6.44

10.20 – 9.35

 

12.28 – 11.25

16.93 – 15.52

characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption(kW)

1.50

2.20

 

2.62

3.65

 

 

 

 

 

 

 

 

 

 

 

 

Heating

Power factor

(%)

97

98

 

97

98

 

 

 

 

 

 

 

 

 

 

 

COP

 

3.73

3.64

 

4.27

3.84

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

A

A

 

A

A

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy rating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum current

 

 

15.48

15.90

 

21.35

21.35

 

 

 

 

 

 

 

 

 

 

 

Main unit

 

 

 

Shine white

 

 

 

 

 

 

 

 

 

 

 

Appearance

 

Ceiling panel

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Sold separately)

Panel color

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

(mm)

210

210

 

210

210

 

 

 

 

 

 

 

 

 

 

 

 

Main unit

Width

(mm)

910

1180

 

1595

1595

 

 

 

 

 

 

 

 

 

 

Outer

 

 

Depth

(mm)

680

680

 

680

680

 

 

 

 

 

 

 

 

 

dimension

 

 

Height

(mm)

 

 

 

 

 

 

 

Ceiling panel

 

 

 

 

 

 

 

 

 

Width

(mm)

 

 

 

(Sold separately)

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

(mm)

 

 

 

 

 

 

 

 

 

 

 

Total weight

 

Main unit

 

(kg)

21

25

 

33

33

 

 

 

 

 

 

 

 

 

 

Ceiling panel (Sold separately)

(kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat exchanger

 

 

 

 

Finned tube

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

Centrifugal

Centrifugal

 

Centrifugal

Centrifugal

 

 

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow

H/M/L

(m³/min.)

13.0/11.2/10.0

18.5/16.7/14.6

 

27.5/24.0/21.2

30.0/26.0/23.1

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

60

60

 

120

120

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

 

Attached main unit

 

 

 

 

 

 

 

 

 

Controller (Sold separately)

 

 

RBC-AMT31E, AS21E2, TCB-SC642TLE2, AX21UCE2

 

 

 

 

 

 

 

 

 

Sound pressure level

H/M/L

(dB•A)

36 / 33 / 30

38 / 36 / 33

 

41 / 38 / 36

43 / 40 / 37

 

 

 

 

 

 

 

 

 

Sound power level

H/M/L

(dB•A)

51 / 48 / 45

53 / 51 / 48

 

56 / 53 / 50

58 / 55 / 52

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas side

(mm)

12.7

15.9

 

15.9

15.9

 

 

 

 

 

 

 

 

 

 

Connecting pipe

 

Liquid side

(mm)

6.4

9.5

 

9.5

9.5

 

 

 

 

 

 

 

 

 

 

 

 

Drain port

(mm)

 

VP25

 

 

 

 

 

 

 

 

 

 

 

: IEC standard, : AS standard

– 15 –

<Twin type>

 

 

Indoor unit 1

 

RAV-

 

SM562CT-E

SM802CT-E

 

 

 

 

 

 

 

 

Model

 

Indoor unit 2

 

RAV-

 

SM562CT-E

SM802CT-E

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

RAV-

 

SP1104AT(Z)(ZG)-E

SP1404A(Z)(ZG)-E

 

 

 

 

 

 

 

 

Cooling capacity

 

 

(kW)

 

10.0

12.5

 

 

 

 

 

 

 

 

Heating capacity

 

 

(kW)

 

11.2

14.0

 

 

 

 

 

 

 

 

 

 

 

 

Indoor unit

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

 

Running current

(A)

 

12.51 – 11.47

17.30 – 15.86

 

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

 

2.67

3.73

 

 

 

 

 

 

 

 

 

 

Cooling

Power factor

(%)

 

97

98

 

 

 

 

 

 

 

 

 

 

 

EER

 

 

3.75

3.35

 

 

 

 

 

 

 

Electrical

 

 

Energy efficiency class

 

A

A

 

 

 

 

 

 

 

characteristics

 

 

Running current

(A)

 

12.28 – 11.25

16.93 – 15.52

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

 

2.62

3.65

 

 

 

 

 

 

 

 

 

 

Heating

Power factor

(%)

 

97

98

 

 

 

 

 

 

 

 

 

 

 

COP

 

 

4.27

3.84

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

 

A

A

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

Centrifugal

Centrifugal

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow

H/M/L

(m³/min.)

 

13.0 / 11.2 / 10.0

18.5 / 16.7 / 14.6

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

 

60

60

 

 

 

 

 

 

 

Sound pressure level

H/M/L

(dB•A)

 

36 / 33 / 30

38 / 36 / 33

 

 

 

 

 

 

 

Sound power level

H/M/L

(dB•A)

 

51 / 48 / 45

53 / 51 / 48

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

Standard length

 

(m)

 

7.5

7.5

 

 

 

 

 

 

 

 

 

 

Min. length

 

(m)

 

3

3

 

 

 

 

 

 

 

 

Outer

 

Max. total length

 

(m)

 

50

50

 

 

 

 

 

 

 

dimension

 

Over 30m

 

 

 

40g/m (31m to 50m)

40g/m (31m to 50m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

Outdoor lower

(m)

 

30

30

 

 

 

 

 

 

 

 

 

difference

Outdoor higher

(m)

 

30

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

Propeller fan

Propeller fan

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow volume

(m³/min.)

 

101

103

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

 

100 + 100

100 + 100

 

 

 

 

 

 

 

 

 

 

Gas side

Main

(mm)

 

15.9

15.9

 

 

 

 

 

 

 

Connecting

 

Sub

(mm)

 

12.7

15.9

 

 

 

 

 

 

 

 

 

 

pipe

 

Liquid side

Main

(mm)

 

9.5

9.5

 

 

 

 

 

 

 

 

 

 

 

 

Sub

(mm)

 

6.4

9.5

 

 

 

 

 

 

 

 

 

 

 

Sound pressure level

Cooling/Heating

(dB•A)

 

49 / 50

51 / 52

 

 

 

 

 

 

 

Sound power level

Cooling/Heating

(dB•A)

 

66 / 67

68 / 69

 

 

 

 

 

 

 

 

: IEC standard

– 16 –

1-1-4. High Wall Type

<Single type>

Model

 

Indoor unit

 

RAV-

SM562KRT-E

 

SM802KRT-E

 

 

 

 

 

 

 

 

Outdoor unit

 

RAV-

SP562AT(Z)(ZG)-E

 

SP802AT(Z)(ZG)-E

 

 

 

 

 

 

 

 

 

 

 

 

Cooling capacity

 

 

(kW)

5.0

 

6.9

 

 

 

 

 

 

 

 

Heating capacity

 

 

(kW)

5.6

 

8.0

 

 

 

 

 

 

 

Power supply

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

 

Running current

(A)

8.33 – 7.63

 

13.15 – 12.05

 

 

 

 

 

 

 

 

 

 

Power consumption(kW)

1.39

 

2.4

 

 

 

 

 

 

 

 

 

 

Cooling

Power factor

(%)

95

 

94

 

 

 

 

 

 

 

 

 

EER

 

3.60

 

2.88

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

A

 

C

 

 

 

 

 

 

 

 

 

 

 

Energy rating

 

 

Electrical

 

 

 

 

 

 

 

 

 

Running current

(A)

8.14 – 7.46

 

12.91 – 11.84

characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption(kW)

1.55

 

2.4

 

 

 

 

 

 

 

 

 

 

Heating

Power factor

(%)

95

 

94

 

 

 

 

 

 

 

 

 

COP

 

3.61

 

3.33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

A

 

C

 

 

 

 

 

 

 

 

 

 

 

Energy rating

 

 

 

 

 

 

 

 

 

 

 

 

Maximum current

 

 

15.34

 

15.47

 

 

 

 

 

 

 

 

 

 

Main unit

 

 

 

Pure white

 

 

 

 

 

 

 

 

Appearance

 

Ceiling panel

Model

 

 

 

 

 

 

 

 

 

 

 

(Sold separately)

Panel color

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

(mm)

298

 

298

 

 

 

 

 

 

 

 

 

 

Main unit

Width

(mm)

998

 

998

 

 

 

 

 

 

 

 

Outer

 

 

Depth

(mm)

221

 

221

 

 

 

 

 

 

 

dimension

 

 

Height

(mm)

 

 

 

 

 

 

 

Ceiling panel

 

 

 

 

 

 

 

Width

(mm)

 

 

 

(Sold separately)

 

 

 

 

 

 

 

 

 

 

 

Depth

(mm)

 

 

 

 

 

 

 

 

 

Total weight

 

Main unit

 

(kg)

12

 

12

 

 

 

 

 

 

 

 

Ceiling panel (Sold separately)

(kg)

 

 

 

 

 

 

 

 

 

 

 

 

Heat exchanger

 

 

 

 

Finned tube

 

 

 

 

 

 

 

 

 

 

Fan

 

 

Cross flow fan

 

Cross flow fan

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow

H/M/L

(m³/min.)

14.0 / 12.5 / 10.7

 

18.5 / 14.6 / 12.2

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

30

 

30

 

 

 

 

 

 

 

Air filter

 

 

 

Attached main unit

 

 

 

 

 

 

 

Controller (Sold separately)

 

 

RBC-AMT31E, AS21E2, TCB-SC642TLE2, AX21UCE2

 

 

(FCU comes with WH-H2UE)

 

 

 

 

 

 

 

 

 

 

 

 

Sound pressure level

H/M/L

(dB•A)

39 / 36 / 33

 

45 / 41 / 36

 

 

 

 

 

 

 

Sound power level

H/M/L

(dB•A)

54 / 51 / 48

 

60 / 56 / 51

 

 

 

 

 

 

 

 

 

 

 

Gas side

(mm)

12.7

 

15.9

 

 

 

 

 

 

 

 

Connecting pipe

 

Liquid side

(mm)

6.4

 

9.5

 

 

 

 

 

 

 

 

 

 

 

Drain port

(mm)

 

VP16

 

 

 

 

 

 

 

 

: IEC standard, : AS standard

– 17 –

<Twin type>

 

 

Indoor unit 1

 

RAV-

 

SM562KRT-E

SM802KRT-E

 

 

 

 

 

 

 

 

Model

 

Indoor unit 2

 

RAV-

 

SM562KRT-E

SM802KRT-E

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

RAV-

 

SP1104AT(Z)(ZG)-E

SP1404AT(Z)(ZG)-E

 

 

 

 

 

 

 

 

Cooling capacity

 

 

(kW)

 

10.0

12.3

 

 

 

 

 

 

 

 

Heating capacity

 

 

(kW)

 

11.2

14.0

 

 

 

 

 

 

 

 

 

 

 

 

Indoor unit

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

 

Running current

(A)

 

12.98 – 11.90

18.00 – 16.50

 

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

 

2.77

3.88

 

 

 

 

 

 

 

 

 

 

Cooling

Power factor

(%)

 

97

98

 

 

 

 

 

 

 

 

 

 

 

EER

 

 

3.61

3.17

 

 

 

 

 

 

 

Electrical

 

 

Energy efficiency class

 

A

B

 

 

 

 

 

 

 

characteristics

 

 

Running current

(A)

 

13.12 – 12.03

17.76 – 16.28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

 

2.80

3.83

 

 

 

 

 

 

 

 

 

 

Heating

Power factor

(%)

 

97

98

 

 

 

 

 

 

 

 

 

 

 

COP

 

 

4.00

3.66

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

 

A

A

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

Cross flow fan

Cross flow fan

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow

H/M/L

(m³/min.)

 

14.0 / 12.5 / 10.7

18.5 / 14.6 / 12.2

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

 

30

30

 

 

 

 

 

 

 

Sound pressure level

H/M/L

(dB•A)

 

39 / 36 / 33

45 / 41 / 36

 

 

 

 

 

 

 

Sound power level

H/M/L

(dB•A)

 

54 / 51 / 48

60 / 56 / 51

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

Standard length

 

(m)

 

7.5

7.5

 

 

 

 

 

 

 

 

 

 

Min. length

 

(m)

 

3

3

 

 

 

 

 

 

 

 

Outer

 

Max. total length

 

(m)

 

50

50

 

 

 

 

 

 

 

dimension

 

Over 30m

 

 

 

40g/m (31m to 50m)

40g/m (31m to 50m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

Outdoor lower

(m)

 

30

30

 

 

 

 

 

 

 

 

 

difference

Outdoor higher

(m)

 

30

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

Propeller fan

Propeller fan

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow volume

(m³/min.)

 

101

103

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

 

100 + 100

100 + 100

 

 

 

 

 

 

 

 

 

 

Gas side

Main

(mm)

 

15.9

15.9

 

 

 

 

 

 

 

Connecting

 

Sub

(mm)

 

12.7

15.9

 

 

 

 

 

 

 

 

 

 

pipe

 

Liquid side

Main

(mm)

 

9.5

9.5

 

 

 

 

 

 

 

 

 

 

 

 

Sub

(mm)

 

6.4

9.5

 

 

 

 

 

 

 

 

 

 

 

Sound pressure level

Cooling/Heating

(dB•A)

 

49 / 50

51 / 52

 

 

 

 

 

 

 

Sound power level

Cooling/Heating

(dB•A)

 

66 / 67

68 / 69

 

 

 

 

 

 

 

 

: IEC standard

– 18 –

1-1-5. Compact 4-Way Cassette (600 × 600) Type

<Single type>

Model

 

Indoor unit

 

 

RAV-SM562MUT-E

 

 

 

 

 

 

Outdoor unit

 

 

RAV-SP562AT(Z)(ZG)-E

 

 

 

 

 

 

 

 

 

 

Cooling capacity

 

 

(kW)

5.0

 

 

 

 

 

 

Heating capacity

 

 

(kW)

5.6

 

 

 

 

 

 

Power supply

 

 

 

1 phase 230V

 

 

 

 

 

 

 

 

 

Running current

(A)

6.6 – 7.15

 

 

 

 

 

 

 

 

Power consumption(kW)

1.53

 

 

 

 

 

 

 

 

Cooling

Power factor

(%)

97

 

 

 

 

 

 

 

EER

 

3.27

 

 

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

A

 

 

 

 

 

 

 

 

 

Energy rating

 

4.5

Electrical

 

 

 

 

 

 

 

Running current

(A)

6.62 – 7.21

characteristics

 

 

 

 

 

 

 

 

 

 

Power consumption(kW)

1.54

 

 

 

 

 

 

 

 

Heating

Power factor

(%)

97

 

 

 

 

 

 

 

COP

 

3.64

 

 

 

 

 

 

 

 

 

 

 

 

Energy efficiency class

A

 

 

 

 

 

 

 

 

 

Energy rating

 

4.5

 

 

 

 

 

 

 

 

Maximum current

 

 

15.53

 

 

 

 

 

 

 

 

Main unit

 

 

Zinc hot dipping steel plate

 

 

 

 

 

 

Appearance

 

Ceiling panel

Model

 

RBC-UM11PG(W)-E

 

 

 

 

 

 

 

(Sold separately)

Panel color

 

Moon-white (Muncel 2.5GY 9.0 / 0.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

(mm)

268

 

 

 

 

 

 

 

 

Main unit

Width

(mm)

575

 

 

 

 

 

 

Outer

 

 

Depth

(mm)

575

 

 

 

 

 

dimension

 

 

Height

(mm)

27

 

 

 

 

 

Ceiling panel

 

 

 

 

 

Width

(mm)

700

 

 

(Sold separately)

 

 

 

 

 

 

 

 

Depth

(mm)

700

 

 

 

 

 

 

Total weight

 

Main unit

 

(kg)

17

 

 

 

 

 

 

Ceiling panel (Sold separately)

(kg)

3

 

 

 

 

 

 

 

 

Heat exchanger

 

 

 

Finned tube

 

 

 

 

 

 

 

 

Fan

 

 

Turbo fan

 

 

 

 

 

 

Fan unit

 

Standard air flow

H/M/L

(m³/min.)

13.3 / 11.2 / 9.1

 

 

 

 

 

 

 

 

Motor

 

(W)

60

 

 

 

 

 

 

Air filter

 

 

 

 

 

 

 

 

Controller (Sold separately)

 

 

As per enclosure

 

 

 

 

 

Sound pressure level

H/M/L

(dB•A)

43 / 39 / 34

 

 

 

 

 

Sound power level

H/M/L

(dB•A)

58 / 54 / 49

 

 

 

 

 

 

 

 

 

Gas side

(mm)

12.7

 

 

 

 

 

 

Connecting pipe

 

Liquid side

(mm)

6.4

 

 

 

 

 

 

 

 

 

Drain port

(mm)

VP25

 

 

 

 

 

 

– 19 –

<Twin type>

 

 

Indoor unit 1

 

RAV-

 

SM562MUT-E

 

 

 

 

 

 

 

Model

 

Indoor unit 2

 

RAV-

 

SM562MUT-E

 

 

 

 

 

 

 

 

 

Outdoor unit

 

RAV-

 

SP1104(Z)(ZG)-E

 

 

 

 

 

 

 

Cooling capacity

 

 

(kW)

 

10.0

 

 

 

 

 

 

 

Heating capacity

 

 

(kW)

 

11.2

 

 

 

 

 

 

 

 

 

 

 

Indoor unit

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

Running current

(A)

 

12.51 – 11.47

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

 

2.67

 

 

 

 

 

 

 

 

 

Cooling

Power factor

(%)

 

97

 

 

 

 

 

 

 

 

 

 

EER

 

 

3.75

 

 

 

 

 

 

Electrical

 

 

Energy efficiency class

 

A

 

 

 

 

 

 

characteristics

 

 

Running current

(A)

 

12.51 – 11.47

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

 

2.67

 

 

 

 

 

 

 

 

 

Heating

Power factor

(%)

 

97

 

 

 

 

 

 

 

 

 

 

COP

 

 

4.19

 

 

 

 

 

 

 

 

 

Energy efficiency class

 

A

 

 

 

 

 

 

 

 

 

Fan

 

 

 

Turbo fan

 

 

 

 

 

 

 

Fan unit

 

Standard air flow

H/M/L

(m³/min.)

 

13.3 / 11.2 / 9.1

 

 

 

 

 

 

 

 

 

Motor

 

(W)

 

60

 

 

 

 

 

 

Sound pressure level

H/M/L

(dB•A)

 

43 / 39 / 34

 

 

 

 

 

 

Sound power level

H/M/L

(dB•A)

 

58 / 54 / 49

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

Standard length

 

(m)

 

7.5

 

 

 

 

 

 

 

 

 

Min. length

 

(m)

 

3

 

 

 

 

 

 

 

Outer

 

Max. total length

 

(m)

 

50

 

 

 

 

 

 

dimension

 

Over 30m

 

 

 

40g/m (31m to 50m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

Outdoor lower

(m)

 

30

 

 

 

 

 

 

 

 

difference

Outdoor higher

(m)

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

Propeller fan

 

 

 

 

 

 

 

Fan unit

 

Standard air flow volume

(m³/min.)

 

101

 

 

 

 

 

 

 

 

 

Motor

 

(W)

 

100 + 100

 

 

 

 

 

 

 

 

 

Gas side

Main

(mm)

 

15.9

 

 

 

 

 

 

Connecting

 

Sub

(mm)

 

12.7

 

 

 

 

 

 

 

 

 

pipe

 

 

Main

(mm)

 

9.5

 

 

Liquid side

 

 

 

 

 

 

 

 

 

Sub

(mm)

 

6.4

 

 

 

 

 

 

 

 

 

 

Sound pressure level

Cooling/Heating

(dB•A)

 

49 / 50

 

 

 

 

 

 

Sound power level

Cooling/Heating

(dB•A)

 

66 / 67

 

 

 

 

 

 

 

: IEC standard

– 20 –

1-2. Outdoor Unit

<Super Digital Inverter>

Model name

 

Outdoor unit

RAV-SP

562AT(Z)(ZG)-E

 

802AT(Z)(ZG)-E

1104AT(Z)(ZG)-E

1404AT(Z)(ZG)-E

 

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

(Power exclusive to outdoor is required.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

 

 

Hermetic compressor

 

 

 

 

 

 

 

 

 

 

 

 

Compressor

 

Motor

 

(kW)

2

 

2

3.75

 

3.75

 

 

 

 

 

 

 

 

 

 

 

 

 

Pole

 

 

4

 

4

4

 

4

 

 

 

 

 

 

 

 

 

 

Refrigerant charged

 

(kg)

1.5

 

2.1

3.1

 

3.1

 

 

 

 

 

 

 

 

 

 

 

Refrigerant control

 

 

 

 

 

Pulse motor valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard length

(m)

7.5

 

7.5

7.5

 

7.5

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. total length

(m)

50

 

50

75

 

75

Inter

 

 

 

 

 

 

 

 

 

 

 

Additional refrigerant charge

 

20g/m

 

40g/m

40g/m

 

40g/m

connecting pipe

 

 

 

 

 

under long piping connector

 

(21m to 50m)

 

(31m to 50m)

(31m to 75m)

 

(31m to 75m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

Outdoor lower

(m)

30

 

30

30

 

30

 

 

 

 

 

 

 

 

 

 

 

 

difference

Outdoor higher

(m)

30

 

30

30

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

 

(mm)

795

 

795

1340

 

1340

 

 

 

 

 

 

 

 

 

 

 

Outer dimension

 

Width

 

(mm)

900

 

900

900

 

900

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

 

(mm)

320

 

320

320

 

320

 

 

 

 

 

 

 

 

 

 

 

Appearance

 

 

 

 

 

Silky shade (Muncel 1Y8.5/0.5)

 

 

 

 

 

 

 

 

 

 

 

 

Total weight

 

 

(kg)

55

 

62

93

 

93

 

 

 

 

 

 

 

 

 

 

 

Heat exchanger

 

 

 

 

 

Finned tube

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

 

Propeller fan

 

 

 

 

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow

(m³/h)

57

 

57

101

 

103

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

63

 

63

100 + 100

 

100 + 100

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas side

 

(mm)

12.7

 

15.9

15.9

 

15.9

Connecting pipe

 

 

 

 

 

 

 

 

 

 

 

Liquid side

 

(mm)

6.4

 

9.5

9.5

 

9.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sound pressure level

Cooling/Heating

(dB•A)

46 / 47

 

47 / 49

49 / 50

 

51 / 52

 

 

 

 

 

 

 

 

 

 

 

Sound power level

 

Cooling/Heating

(dB•A)

63 / 64

 

64 / 66

66 / 67

 

68 / 69

 

 

 

 

 

 

 

 

 

 

Outside air temperature, Cooling

(°C)

 

 

43 to –15°C

 

 

 

 

 

 

 

 

 

 

Outside air temperature, Heating

(°C)

15 to –15°C

15 to –20°C

 

 

 

 

 

 

 

 

 

 

 

 

– 21 –

1-3. Operation Characteristic Curve

• Operation characteristic curve <Super Digital Inverter>

RAV-SP1104AT-E, SP1404AT-E / RAV-SP1104ATZ-E, SP1404ATZ-E / RAV-SP1104ATZG-E, SP1404ATZG-E

<Cooling>

 

 

 

 

<Heating>

 

 

 

 

 

22

 

 

 

 

 

22

 

 

 

 

 

20

 

 

 

 

 

20

 

 

 

 

 

18

RAV-SP1404

 

 

 

18

RAV-SP1104

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

16

 

 

 

 

 

14

 

 

 

 

 

14

 

 

 

 

(A)

12

 

 

 

 

(A)

12

 

 

RAV-SP1404

 

Current

 

 

 

 

Current

 

 

 

 

10

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

8

 

 

 

 

 

 

 

RAV-SP1104

 

 

 

 

 

 

 

 

6

 

 

 

 

 

6

 

 

 

 

 

4

 

• Conditions

 

 

 

4

 

• Conditions

 

 

 

Indoor : DB27˚C/WB19˚C

 

 

 

Indoor : DB20˚C

 

 

 

 

Outdoor : DB35˚C

 

 

 

 

Outdoor : DB7˚C/WB6˚C

 

 

2

 

Air flow : High

 

 

2

 

Air flow : High

 

 

 

Pipe length : 7.5m

 

 

 

Pipe length : 7.5m

 

 

 

 

230V

 

 

 

 

 

230V

 

 

 

0

20

40

60

80

 

0

20

40

60

80

 

0

 

0

Compressor speed (rps)

Compressor speed (rps)

• Capacity variation ratio according to temperature

RAV-SP1104AT-E, SP1404AT-E / RAV-SP1104ATZ-E, SP1404ATZ-E / RAV-SP1104ATZG-E, SP1404ATZG-E

<Cooling>

 

 

 

 

 

 

 

 

 

<Heating>

 

 

 

 

 

 

 

 

105

 

 

 

 

 

 

 

 

 

 

 

120

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

110

 

 

 

 

 

 

 

 

95

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

 

 

 

 

 

 

 

 

 

 

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(%)

85

 

 

 

 

 

 

 

 

 

 

(%)

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ratio

80

 

 

 

 

 

 

 

 

 

 

ratio

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

70

 

 

 

 

 

 

 

 

 

 

Capacity

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

 

 

 

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

65

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

• Conditions

 

 

 

 

 

20

 

• Conditions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

 

 

 

Indoor : DB27˚C/WB19˚C

 

 

 

 

Indoor : DB20˚C

 

 

 

 

 

 

 

Indoor air flow : High

 

 

 

10

 

Indoor air flow : High

 

 

 

 

 

 

 

Pipe length : 7.5m

 

 

 

 

 

Pipe length : 7.5m

 

 

 

50

33

34

35

36

37

38 39

40

41

42

43

 

0

-6

-4 -2 0

2

4

6

8

10

 

32

 

-20 -18 -16 -14 -12 -10 -8

Outdoor temp. (˚C)

Outdoor temp. (˚C)

– 22 –

2. CONSTRUCTION VIEWS (EXTERNAL VIEWS)

2-1. Indoor Unit

RAV-SM564UT-E

860 to 910 Ceiling open dimension

Take-in port of wiring

 

 

30

 

 

44

 

 

 

 

 

 

 

 

172

112

77

105

 

 

Refrigerant pipe connecting port

 

74

 

 

Ø6.4 (Liquid side)

 

 

 

 

 

 

 

 

 

Refrigerant pipe connecting port

397.5

105

337.5

Ø12.7 (Gas side)

157

263

 

 

 

 

 

 

 

1000 or more

openCeilingdimension

1000 or more

15 or more

moreor15

 

 

An obstacle

 

 

1000 or more

910

 

The space that is necessary

 

for equipping and service

to

 

 

 

Standing 661or less

860

 

 

300

 

 

 

 

Bottom face of ceiling

 

Standing 850 or less

129

189

 

 

 

 

Indoor unit

 

Bottom face of ceiling

Drain pipe

Drain upstanding size

connecting port

 

 

(Meterial : PP)

 

 

 

Bottom face of ceiling 129

77 10 5

74

Ø162

80

240

135 105 287.5

external dimension

 

 

105

Unit

 

 

207.5

840

106.5 72 241.5

For branch duct knockout square hole Ø150

Electric parts box

950 Panel external dimension

780 Hanging bolt pitch

323

408

Hanging bolt M10 or Ø3/8(procured by locally)

256

132

416.5

pitchboltHanging

dimension

74

 

 

 

351

 

129 For branch duct

 

 

 

 

105

77

knockout square

 

 

 

 

hole Ø150

 

 

 

 

 

 

 

690 ± 20

950Panel external

384 105

 

16.5

Ceiling panel

 

 

 

 

 

 

45˚

 

 

 

 

(sold separately)

 

 

 

 

 

105

Ø162

269

 

Z

57

64

 

Bottom face

29

of ceiling

 

For branch duct knockout square hole Ø150

(2 positions)

For branch duct knockout square hole Ø150

Bottom face of ceiling

840 Unit external dimension

362.5 105 372.5

 

 

74

 

 

105

129

5

77

 

 

32

61

 

 

 

.5

Knockout for simple

 

 

 

28

 

 

 

0A for Ø100

155 187

Indoor unit

Bottom face of ceiling

Bottom face of ceiling

Z view

12

Unit : mm

– 23 –

RAV-SM804UT-E

Take-in port of wiring

44

172

112

Refrigerant pipe connecting port Ø9.5 (Liquid side)

Refrigerant pipe connecting port Ø15.9 (Gas side)

860 to 910 Ceiling open dimension

Bottom face of ceiling

30

77

105

 

74

397.5 105 337.5

157 263

 

 

 

15 or more

 

1000 or more

dimensionopen

 

more

 

 

 

1000or

moreor15

 

An obstacle

 

 

 

 

 

 

 

 

 

 

1000 or more

Ceiling

 

 

The space that is necessary

910

 

 

for equipping and service

 

 

 

 

Standing 661or less

860 to

 

 

 

300

 

 

 

 

 

 

 

 

 

 

Standing 850 or less

129

189

Indoor unit

 

Bottom face of ceiling

 

 

 

Drain upstanding size

Drain pipe connecting port (Meterial : PP)

Bottom face of ceiling

129

 

77 10 5

74

Ø162

 

287.5

80

 

 

105

240

135

 

105

 

207.5

106.5 72 241.5

For branch duct knockout square hole Ø150

Electric parts box

950 Panel external dimension

780 Hanging bolt pitch

323

dimension

408

840 Unit external

 

Hanging bolt M10 or Ø3/8 (procured by locally)

256

132

416.5

pitchboltHanging

dimension

74

 

 

 

351

 

129 For branch duct

 

 

 

 

105

77

knockout square

 

 

 

 

hole Ø150

 

 

 

 

 

 

 

690 ± 20

950Panel external

384 105

 

16.5

Ceiling panel

 

 

 

 

 

 

45˚

 

 

 

 

(sold separately)

105

Ø162

269

 

Z

57

 

Bottom face

29

of ceiling

 

64

For branch duct knockout square hole Ø150

(2 positions)

For branch duct knockout square hole Ø150

Bottom face of ceiling

840 Unit external dimension

362.5 105 372.5

 

 

74

 

 

105

129

5

77

 

 

32

61

 

 

.5

 

 

 

28

Knockout for simple 0A for Ø100

155 187

Bottom face of ceiling

Z view

Indoor unit

 

Bottom face of ceiling

12

 

Unit : mm

– 24 –

Toshiba RAV-SP1104AT-E, RAV-SP1404AT-E, RAV-SP1104ATZG-E, RAV-SM804UT-E, RAV-SM1104UT-E User Manual

RAV-SM1104UT-E, RAV-SM1404UT-E

860 to 910 Ceiling open dimension

Take-in port of wiring

 

 

30

 

 

44

 

 

 

 

 

 

 

 

172

112

77

105

 

 

Refrigerant pipe connecting port

 

137

 

 

Ø9.5 (Liquid side)

 

 

 

 

 

 

 

 

 

Refrigerant pipe connecting port

397.5

105

337.5

Ø15.9 (Gas side)

 

157

263

 

 

 

 

 

 

 

15 or more

 

1000 or more

dimensionopen

1000or more

 

 

moreor

 

An obstacle

 

 

 

 

 

 

 

 

1000 or more

Ceiling

 

15

 

 

910

 

The space that is necessary

 

for equipping and service

 

 

860 to

 

 

300

Standing 661 or less

129 189

 

 

 

Standing lessor850

Bottom face of ceiling

 

 

 

Indoor unit

 

Bottom face of ceiling

Drain pipe

 

Drain upstanding size

connecting port

 

 

 

 

(Meterial : PP)

Bottom face of ceiling

129

 

77 10 5

137

Ø162

80

240 135 105 287.5

external dimension

 

105

Unit

 

207.5

840

105

Ø162

For branch duct

knockout square hole Ø150 (2 positions)

For branch duct knockout square hole Ø150

106.5 72 241.5

For branch duct knockout square hole Ø150

Electric parts box

950 Panel external dimension

780 Hanging bolt pitch

323

408

269

840 Unit external dimension

362.5 105 372.5

105 137

Hanging bolt M10 or Ø3/8 (procured by locally)

319

132

416.5

pitchboltHanging

dimension

137

 

 

 

351

 

129

For branch duct

 

 

 

 

 

105

77

knockout square

 

 

 

 

 

 

 

hole Ø150

 

 

690 ± 20

950Panel external

384 105

 

16.5

Ceiling panel

 

 

 

 

 

 

 

45˚

 

 

 

 

(sold separately)

 

 

 

 

 

 

 

Bottom face

Z

 

 

 

 

29

 

of ceiling

 

57

 

64

 

 

 

 

 

 

 

 

 

 

32

61

 

 

 

 

 

 

 

.5

 

 

 

 

 

 

28

 

 

 

 

 

 

 

 

155

 

Knockout for simple 0A for Ø100

 

 

 

 

 

 

 

 

 

187

 

 

 

 

Bottom face of ceiling

Bottom face of ceiling

129

5

77

Z view

Indoor unit

Bottom face of ceiling

Unit : mm

– 25 –

2-2. Outdoor Unit

RAV-SP1104AT-E, RAV-SP1404AT-E / RAV-SP1104ATZ-E, RAV-SP1404ATZ-E / RAV-SP1104ATZG-E, RAV-SP1404ATZG-E

 

 

Note

 

——

 

Kockout hole

 

 

 

 

 

 

 

 

 

 

 

 

Ø38

 

 

 

 

 

 

 

 

Name

Refrigerant piping hole

1 Indoor/Outdoor unit

connecting wire inlet hole

2 Power supply inlet hole

Mounting bolt hole

(Ø12 × 17 U-shape hole)

 

 

 

 

 

Mounting bolt hole

(Ø12 × 17 long hole)

12

 

40

 

 

 

legs Details of B legs

320

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

 

 

 

Details of A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Ø25)

B legs

 

 

54

 

 

 

39

96

 

 

 

 

 

48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drain hole

 

170

 

legs

 

 

 

 

 

 

 

 

A

 

 

 

 

 

60

 

34

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air outlet

 

70

600

900

 

 

200

Air inlet port

46

 

 

port

 

380

 

 

75

 

550

 

 

 

 

383

 

 

 

 

 

 

 

 

 

 

150

 

 

 

 

 

port

 

 

 

 

 

 

 

 

52

 

 

 

Air inlet

 

 

 

 

 

 

 

 

 

 

 

 

128

118

 

 

 

 

 

 

 

 

 

 

 

 

 

74

 

 

 

 

88)

 

 

5.17

 

365

 

 

5.17

 

 

 

 

 

Drain hole (Ø28 ×

 

 

 

 

 

 

 

 

 

 

 

 

 

1340

side)

side)

30

Refrigerant pipe connecting port (Ø9.5 flare at liquid

Refrigerant pipe connecting port (Ø15.9 flare at gas

 

581

74

534

121

 

655

Unit : mm

 

 

 

 

64

 

 

 

5595

 

12

 

 

1

 

 

 

 

 

24

 

 

 

 

 

 

 

151

400

 

 

 

80

 

2

1

 

18

 

 

 

 

 

 

 

 

 

94

 

 

 

 

5595

 

 

 

 

613

 

 

 

 

 

605

155

 

 

 

 

 

 

 

 

2

1

5595

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

135

Z

 

 

 

178

 

 

 

 

 

178

518

 

 

 

 

178

 

327

 

 

 

60

68

piping

581

 

70

downward

 

 

 

 

534

 

85

 

 

 

 

 

360

 

 

Knockout for

 

 

 

 

 

837

7

viewsZ

 

65

– 26 –

RAV-TWP30E2, RAV-TWP50E2 (Simultaneous Twin)

Inner diameter Ø C

 

B

Inner

Inner

diameter Ø D

diameter Ø D

A

Model (RBC-)

A

B

C

D

 

 

 

 

 

 

TWP30E2

Liquid side

36

14

Ø9.5

Ø6.4

 

 

 

 

 

Gas side

43

23

Ø15.9

Ø12.7

 

 

 

 

 

 

 

TWP50E2

Liquid side

34

14

Ø9.5

Ø9.5

 

 

 

 

 

Gas side

44

21

Ø15.9

Ø15.9

 

 

 

 

 

 

 

– 27 –

3. SYSTEMATIC REFRIGERATING CYCLE DIAGRAM

3-1. Indoor Unit

• Single type (Combination of 1 indoor unit and 1 outdoor unit)

(Indoor unit)

Distributor

(Strainer incorporated)

TCJ sensor

Strainer

Air heat

exchanger

TC sensor

Refrigerant pipe at liquid side (Outer dia : ØB)

Refrigerant pipe at gas side (Outer dia : ØA)

To outdoor unit

To outdoor unit

Dimension table

Indoor unit

Outer diameter of refrigerant pipe

 

 

Gas side ØA

Liquid side ØB

 

 

 

 

 

 

SM56,

80 type

12.7

6.4

 

 

 

 

SM110,

140 type

15.9

9.5

 

 

 

 

Capillary tube specifications

Model AIU-

Inner dia. × Length × Q’ty

 

 

SM56 type

Ø2 × 250 × 2, Ø2 × 350 × 1

Ø2 × 700

× 1

 

 

 

 

SM80 type

Ø2 × 250

× 3, Ø2 × 500 × 1

 

 

 

SM110, 140 type

Ø2 × 200

× 1, Ø2 × 300 × 2

Ø2 × 350

× 2, Ø2 × 700 × 1

 

 

 

 

• Twin type (Combination of 2 indoor units and 1 outdoor unit)

(Indoor unit A)

Distributor

(Strainer incorporated)

 

TCJ sensor

 

Strainer

 

Air heat

TC sensor

exchanger

 

Refrigerant pipe

Refrigerant pipe

at liquid side

at gas side

(Outer dia : ØA)

(Outer dia : ØB)

Branch pipe

 

Refrigerant pipe at liquid side (Outer dia : ØC)

(Indoor unit B)

Distributor

(Strainer incorporated)

 

TCJ sensor

 

Strainer

 

Air heat

TC sensor

exchanger

 

Refrigerant pipe

Refrigerant pipe

at liquid side

at gas side

(Outer dia : ØA)

(Outer dia : ØB)

Branch pipe

Refrigerant pipe at liquid side (Outer dia : ØD)

To outdoor unit

 

 

 

 

To outdoor unit

 

 

 

 

 

 

 

Indoor unit

Branch pipe RBC-

A

B

C

D

 

 

 

 

 

 

 

 

SM56 × 2

TWP30E2

6.4

12.7

9.5

15.9

 

 

 

 

 

 

 

 

SM80 × 2

TWP50E2

9.5

15.9

9.5

15.9

 

 

 

 

 

 

 

 

– 28 –

3-2. Outdoor Unit

RAV-SP1104AT-E, SP1104ATZ-E, SP1104ATZG-E, RAV-SP1404AT-E, SP1404ATZ-E, SP1404ATZG-E

 

TS sensor

TO sensor

 

 

 

 

 

 

 

 

 

PMV

 

 

 

TL sensor

 

 

 

 

 

Strainer

 

Check joint

 

TE sensor

Capillary

 

Cooling: High pressure

 

 

 

 

 

Ø4 ×Ø3 (6 pcs.)

 

Heating: Low pressure

 

 

 

 

 

 

 

 

Heat exchanger

Distributor

Refrigerant pipe

 

TD sensor

Ø8, 2 rows, 52 stages

 

 

FP1.45, flat fin

 

at liquid side Ø9.5

 

 

 

 

Packed valve

 

 

In cooling operation

 

 

 

 

In heating operation

 

Refrigerant pipe

 

 

 

Strainer

at gas side Ø15.9

 

 

 

Ball valve

 

Muffler

 

Cooling: Low pressure

 

 

 

Ø25 × L180

Heating: High pressure

 

 

Ø25 × L210

 

 

 

Accumulator

Rotary compressor

 

 

 

(2500cc)

(DA422A3F-25M)

 

 

 

3-3. Systematic Diagram of Refrigerating Cycle

RAV-SP1104AT-E, RAV-SP1104ATZ-E, RAV-SP1104ATZG-E

 

 

 

Pressure

 

 

Pipe surface temperature (°C)

 

Compressor

 

Indoor/Outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(MPa)

(kg/cm²g)

Discharge

Suction

Indoor heat

Outdoor heat

drive revolution

Indoor

temp. conditions

 

 

(DB/WB) (°C)

 

 

exchanger

exchanger

frequency

fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(rps)

 

 

 

 

 

Pd

Ps

Pd

Ps

(TD)

(TS)

(TC)

(TL)

(TE)

 

Indoor

Outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

2.57

0.99

26.2

10.1

66

14

12

44

38

38

HIGH

27/19

35/–

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Overload

3.30

1.09

33.7

11.1

78

9

13

49

43

53

HIGH

32/24

43/–

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low load

1.74

0.75

17.8

7.7

46

7

5

32

25

21

LOW

18/15.5

–5/–

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

2.32

0.73

23.7

7.4

65

3

39

2

3

43

HIGH

20/–

7/6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

Overload

3.22

1.17

32.9

11.9

73

19

54

14

15

26

LOW

30/–

24/18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low load

2.17

0.30

22.1

3.1

87

–15

38

–14

–13

71

HIGH

15/–

–15/–

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*This compressor has 4-pole motor. The value when compressor frequency (Hz) is measured by a clamp meter becomes 2 times of No. of compressor revolutions (rps).

RAV-SP1404AT-E, RAV-SP1404ATZ-E, RAV-SP1404ATZG-E

 

 

 

Pressure

 

 

Pipe surface temperature (°C)

 

Compressor

 

Indoor/Outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(MPa)

(kg/cm²g)

Discharge

Suction

Indoor heat

Outdoor heat

drive revolution

Indoor

temp. conditions

 

 

(DB/WB) (°C)

 

 

exchanger

exchanger

frequency

fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(rps)

 

 

 

 

 

Pd

Ps

Pd

Ps

(TD)

(TS)

(TC)

(TL)

(TE)

 

Indoor

Outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

2.72

0.90

27.8

9.2

73

12

10

46

38

51

HIGH

27/19

35/–

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Overload

3.34

1.07

34.1

10.9

80

9

13

51

45

55

HIGH

32/24

43/–

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low load

1.75

0.76

17.9

7.8

47

8

6

33

25

21

LOW

18/15.5

–5/–

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

2.59

0.69

26.4

7.0

75

3

43

2

2

53

HIGH

20/–

7/6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

Overload

3.13

1.05

31.9

10.7

72

16

53

12

13

26

LOW

30/–

24/18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low load

2.40

0.21

24.5

2.1

97

–22

42

–19

–18

90

HIGH

15/–

–15/–

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*This compressor has 4-pole motor. The value when compressor frequency (Hz) is measured by a clamp meter becomes two times of No. of compressor revolutions (rps).

29 –

4. WIRING DIAGRAM

4-1. Indoor Unit

RAV-SM564UT-E, RAV-SM804UT-E, RAV-SM1104UT-E, RAV-SM1404UT-E

RED

WHI

BLK

Indoor unit earth screw

1 2 3

 

 

 

 

 

 

LM1

 

 

 

 

LM3

 

 

LM2

 

 

LM4

 

 

 

 

 

 

 

 

 

FM

 

1

2

3

4

5

 

 

1

2

3

4

5

1

2

3

4

5

1

2

3

4

5

 

 

 

 

 

 

 

 

 

1

2

3

4

5

 

 

1

2

3

4

5

1

2

3

4

5

1

2

3

4

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(BLU)

 

 

 

 

 

(WHI)

 

 

 

 

(RED)

 

 

 

 

(BLK)

 

 

 

DM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FS

 

 

 

1

3

5

CN333

 

1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20

1

2

1

2

3

 

 

 

 

1

3

5

(WHI)

 

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19 20

1

2

1

2

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN510

 

 

 

 

 

 

CN504

CN34

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor drive

(WHI)

 

 

 

 

 

 

(WHI)

(RED)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN104

1

1

 

 

 

 

 

 

 

 

 

 

 

 

circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(YEL)

2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

3

CN334

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TA

2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN102

1

1

1

1

(WHI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(RED)

2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TCJ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN101

1

1

 

 

Fuse, F01

 

 

 

 

 

 

 

 

 

 

 

Fuse, F02

 

 

 

 

 

 

 

 

(BLK)

2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

 

 

T6.3A, 250V~

 

 

~

 

 

 

+

 

 

T3.15A, 250V~

 

 

 

 

 

 

 

 

 

 

 

1

1

 

 

 

 

 

 

 

 

Power

 

DC20V

CN519

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supply

 

DC15V

(WHI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC12V

3

 

3

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

circuit

 

 

 

 

 

 

CN67

 

 

 

 

 

~

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC7V

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

5

(BLK)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN508

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(RED)

2

 

 

 

P01

 

 

 

 

 

 

Control P.C. Board

 

 

 

 

 

 

 

CN80

1

 

BLK

 

 

 

 

 

 

 

 

for Indoor Unit

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(GRN)

3

 

 

 

 

 

 

 

 

 

 

 

 

 

MCC-1570

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN73

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(EXCT)

 

 

CN66

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(RED)

2

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

(WHI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN70

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(WHI)

2

 

 

 

CN41

 

CN309

 

CN61

 

CN32

 

CN60

 

 

 

 

CN50

 

CN20

 

 

 

 

 

(BLU)

 

(YEL)

 

(YEL)

 

(WHI)

 

(WHI)

 

 

 

 

(WHI)

 

(BLU)

 

 

 

1

2

3

1

3

1

2

3

4

5

6

1

2

1

2

3

4

5

6

1

2

3

4

5

1

2

3

4

5

1

 

3

 

 

 

 

(T10)

 

 

(Fan drive)

 

 

 

 

 

 

1

2

3

4

5

 

 

 

 

 

BLK

BLK

CN51

1

2

3

4

5

(RED) 1

2

3

4

5

 

 

A

B

 

P.C. board

 

 

 

MCC-1440

1 2 3

Serial signal

L N

Signal phase 220–240V~, 50Hz

Outdoor unit

Outdoor unit earth screw

1 2

1 2

A B

CN001 (WHI)

Wired

Adapter for

remote controller

wireless remote controller

Color

Identification

BLK : BLACK

BLU : BLUE

RED : RED

GRN : GREEN

WHI : WHITE

YEL : YELLOW

 

 

1

 

2

 

 

 

 

1

 

2

 

 

 

Terminal

 

 

 

 

 

for central U3

 

U4

 

 

remote controller

 

 

 

 

Connection interface

 

 

(Option)

 

 

 

 

 

 

 

 

Symbol

Parts name

 

 

 

 

 

 

 

FM

 

 

 

Fan Motor

 

TA

 

 

 

Indoor temp. sensor

 

TC, TCJ

Temp. sensor

 

LM1, LM2, LM3, LM4

Louver motor

 

DM

 

 

 

Drain pump Motor

 

 

 

 

 

 

 

FS

 

 

 

Float Switch

– 30 –

Loading...
+ 132 hidden pages