SAFETY INSTRUCTIONS

1. Read these instructions.

2. Keep these instructions.

3.Heed all warnings.

4.Follow all instructions.

5.The user is responsible for fixing the hardware to the surface to ensure safe operation. The fixings must support the weight of the product – please consult the manual’s specification page for the appropriate weights. Please consult the relevant construction codes in your region for further information on suitable hardware fixing methods.

6.Some regional construction codes require the use of a secondary method of securing loudspeakers to surfaces to provide security of a back-up support. A secondary support line should be attached from the safety loop on the rear of the product to a source point on the wall. Please consult the relevant construction codes in your region.

7.Tannoy will not be held accountable for any damage caused by incorrect installation.

2

PRODUCT IDENTIFICATION

IW60 EFX FRONT

Isolation mounts

Isolation mount

Isolation mount

4” Dual ConcenticTM driver

6.5” Dual ConcenrticTM driver

IW60 EFX TOP

Spring terminal posts

Relay switch socket

Phase switch

3

IW63 DC FRONT

Isolation mounts

6.5” Dual ConcentricTM driver

6.5” woofers

Isolation mounts

IW63 DC TOP

Spring terminal posts

4

INSTALLATION GUIDELINES

1. Fit the pre-install bracket frame to the 2ft x 4 ft wooden studs by using suitable fixings (fixings not supplied). See Fig 1

SAFETY NOTICE: The user is responsible for fixing the hardware to the surface to ensure safe operation.

2. Lay the cables

(i)Lay the loudspeaker cable from the amplifier to the installed pre-mount frame. See point 5 for connection instructions.

(ii)iw60EFX only: Note that the iw60EFX features a 12V relay switch which allows the speaker to toggle between “Cinema” and “Music” modes if the AV receiver supports this function. To use this facility you will need to lay two-core loudspeaker cable from the AV receiver to the first iw60EFX pre-mount frame then lay loudspeaker cable from that location to the next iw60EFX pre mount frame to allow daisychaining. See point 6 for connection instructions.

NOTE: The pre-install frame has four 21mm diameter holes to accommodate cables or even conduit, if required (two are positioned at the top and at two are positioned at the bottom). These holes are blocked off by grommets. Simply knock out the appropriate grommets and pass the cables or conduit through the appropriate holes

3.Complete the wall, leaving the pre-install frame exposed. See Fig 2

4.Connect the loudspeaker cables. The positive terminal on the amplifier channel (marked + or coloured red) must be connected to the positive terminal on the loudspeaker (coloured red). The negative terminal on the amplifier channel (marked - or coloured black) must be connected to the negative terminal on the loudspeaker (coloured black). pre-install frame exposed. See

Fig 3

Fig 1.

Fig 2.

Fig 3.

5

5. iw60EFX only: Note that the iw60EFX features a 12V relay switch which allows the speaker to toggle between “Cinema” and “Music” modes if the AV receiver supports this function.

Cinema Mode: This is the default mode of the iw60EFX. The two optimally aligned 100mm (4.00”) Dual Concentric™ drivers generate a wide and even flow of acoustic energy over a large area for a diffuse room filling ambience. The 6.50” Dual Concentric driver is inactive in Cinema mode.

The 4” duals are always out-of-phase with each other in cinema mode. The iw60EFX features a phase switch which inverts the phase of both the 4.00” drivers. Please refer to the following diagrams for reference. See Fig 4

When using left and right iw60EFX speakers, the phase switch on the left iw60 EFX speaker should be in the opposite position from the phase switch on the right iw60 EFX speaker. Please refer to the following diagram for reference. See Fig 5

Music Mode: This is the direct radiating set up where the 165mm (6.50”) constant directivity Dual Concentric™ driver produces a more localised and focused sound, highlighting the distinct separation afforded by modern programme material. The two 4.00” Dual Concentric drivers are inactive in Music mode. Music mode is selected by using a 12V trigger from the AV receiver. See Fig 6

To setup this relay switching facility, use loudspeaker cable to connect the + and - relay switch outputs from the AV receiver to the + and - relay switch inputs on the iw60EFX, remembering to observe correct polarity. The relay input switch socket is a euro-type socket with a loop-through facility, allowing the relay connections on each iw60EFX to be daisy-chained. See Fig 7

6.Offer the loudspeaker up to the pre-install frame and fix the four isolation mounts to the pre-install frame using the supplied fixings then attach the grille by pushing it onto the baffle. See Fig 8

Out

in phase

of phase

 

In phase

Out of

 

phase

Inactive

Inactive

Cinema mode active with the

Cinema mode active with the

phase switch in the UP position.

phase switch in the DOWN position.

Fig 4.

LEFT SPEAKER

RIGHT SPEAKER

PHASE SWITCH = DOWN

PHASE SWITCH = UP

Fig 5.

Inactive

Inactive

Activated

Music mode

Fig 7.

Fig 6.

 

Fig 8.

6

PRODUCT DIMENSIONS

DEFINITION IW60 EFX

75.0

[2.95"]

561.3

590.0

[22.10"]

[23.23"]

316.2

[12.45"]

345.0

[13.58"]

94.0

[3.70"]

DEFINITION IW63

75.0

[2.95"]

561.3

590.0

[23.23"]

[22.10"]

 

316.2

[12.45"]

345.0

[13.58"]

94.0

[3.70"]

7

TECHNICAL SPECIFICATIONS FULL RANGE MODELS

SYSTEM

 

IW60 EFX

 

IW63

 

Frequency Response (-3dB) (1,4)

 

110Hz - 23kHz

 

80Hz - 28kHz

 

Frequency Range (-10dB) (1,4)

 

74Hz - 27kHz

 

54Hz - 40kHz

 

System Sensitivity (1W @1m) (2,4)

90dB (1W = 2.83V for 8 ohms)

91dB (1W = 2.83V for 8 ohms)

Nominal Coverage Angles

 

90 degrees Conical in music mode

90 degrees Conical

 

 

120 degrees H x 90 degrees cinema mode

120 degrees Conical

Coverage Angle (1kHz to 6kHz)

 

120 degrees

 

120 degrees Conical

Directivity Factor (Q)

 

3.5 averaged 1kHz to 6kHz

3.5 averaged 1kHz to 6kHz

Directivity Index (Di)

 

5.5 averaged 1kHz to 6kHz

5.5 averaged 1kHz to 6kHz

Power Handling (3)

Average

100W

 

100W

 

 

Programme

200W

 

200W

 

 

Peak

400W

 

400W

 

Recommended Amplifier Power

 

200W @ 8 Ohms

200W @ 8 Ohms

 

Rated Maximum SPL(3)

Average

110dB

 

111dB

 

 

Peak

116dB

 

117dB

 

Nominal Impedance

 

8 Ohms music mode

8 Ohms

 

 

 

4 Ohms cinema mode

 

 

Crossover

 

1.6kHz

 

320Hz, 1.5kHz

 

Distortion 10% Full Power

 

(8.94V) 2nd Harmonic 3rd Harmonic

(8.94V) 2nd Harmonic

3rd Harmonic

250Hz

 

1.84%

0.30%

0.18%

0.08%

1kHz

 

0.34%

0.61%

0.89%

1.05%

10kHz

 

0.91%

0.17%

1.30%

0.18%

Distortion 1% Full Power

 

(2.83V) 2nd Harmonic 3rd Harmonic

(2.83V) 2nd Harmonic

3rd Harmonic

250Hz

 

0.19%

0.35%

0.90%

0.38%

1kHz

 

0.40%

0.32%

0.39%

0.61%

10kHz

 

0.46%

0.89%

0.54%

0.55%

TRANSDUCERS

 

 

Music Mode

1 x 165mm (6.5”) constant directivity Dual Concentric TM

___

Cinema Mode

2 x 100mm (4.0”) Dual Concentric TM in dipole configuration

___

Low Frequency

___

2 x 165mm (6.5”) woofers

 

Mid and High Frequency

___

1 x 165mm (6.5 constant directivity Dual ConcentricTM

CONSTRUCTION

 

 

Enclosure

11.5 litre (net total volume), closed and internally

11.5 litre, closed and internally braced MDF enclosure

 

braced MDF enclosure

 

Finish

Textured black paint

Textured black paint

 

White powder coated perforated steel grille, foam behind

White powder coated perforated steel grille, foam behind

Connectors

Gold plated spring terminals

Gold plated spring terminals

Controls

Mode selection input (12VDC relay activated via Dinkle connector

___

 

 

Polarity switch)

 

Dimensions (H x W x D)

590mm x 345mm x 94mm

590mm x 345mm x 94mm

 

(23.23” x 13.58” x 3.70”)

(23.23” x 13.58” x 3.70”)

Weight

9.5kg

10.5kg

 

 

Accessories

Installation kit required (not included)

Installation kit required (not included)

Notes (1) Average over stated bandwidth. Measured in an IEC bafflle in an Anechoic Chamber

(2)Unweighted Pink noise input, measured at 1m on axis

(3)Long term power handling capacity as defined in EIA - 426B test

(4)Music Mode

(5)Cinema mode. For music mode refer to iW63 data

A full range of measurements, performance data, and Ease™ Data can be downloaded from www.tannoy.com. Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications, which Tannoy reserves the right to alter without prior notification.

8

WARRANTY STATEMENT

No maintenance of the Definition loudspeaker is necessary.

Please register your Tannoy product online at www.tannoy.com.

All of our products have been produced and tested with care and precision to give first-class service.

All passive components are guaranteed for a period of five years from the date of purchase from an authorised Tannoy dealer subject to the absence or evidence of misuse, overload, or accidental damage.

All active and electronic components are guaranteed for a period of one year from the date of purchase from an authorised Tannoy dealer subject to the absence of, or evidence of, misuse, overload or accidental damage.

If at any time during this warranty period the equipment proves to be defective for any reason other than accident, misuse, neglect, unauthorised modification or fair wear and tear, we will repair any such manufacturing defect or, at our option, replace it without charge for labour, parts or return carriage.

If you suspect a problem with a Tannoy product then, in the first instance, discuss it with your Tannoy dealer. If you require further assistance then we ask that you deal directly with your local Tannoy distributor. If you cannot locate your distributor please contact Customer Services, Tannoy Ltd at the address given below.

Customer Services, Tannoy Ltd., Rosehall Industrial Estate, Coatbridge, Strathclyde ML5 4TF, Scotland

Telephone:

01236 420199

(National)

 

+44 1236 420199

(International)

Fax:

01236 428230

(National)

 

+44 1236 428230

(International)

E-mail:

enquiries@tannoy.com

DO NOT SHIP ANY PRODUCT TO TANNOY WITHOUT PREVIOUS AUTHORISATION

Our policy commits us to incorporating improvements to our products through continuous research and development. Please confirm current specifications for critical applications with your supplier.

9

DECLARATION OF CONFORMITY

The following apparatus is manufactured in the UK at Tannoy Ltd of Rosehall Industrial Estate, Coatbridge, Scotland, ML5 4TF and conform(s) to the protection requirements of the European Electromagnetic Compatibility Standards and Directives relevant to Domestic Electrical Equipment. The apparatus is designed and constructed such that electromagnetic disturbances generated do not exceed levels allowing radio and telecommunications equipment and other apparatus to operate as intended, and, the apparatus has an adequate level of intrinsic immunity to electromagnetic disturbance to enable operation as specified and intended.

Details of the Apparatus:

Tannoy Contractor Loudspeaker

 

Model Number: Definition Install

Associated Technical File:

EMCi6

 

Applicable Standards:

EN 50081-1

Emission

 

EN 50082-1

Immunity

Signed:

Position: Director of Engineering (Professional)

Date: 18th Oct. 07

10

Tannoy United Kingdom

T: 00 44

(0) 1236 420199

E: enquiries@tannoy.com

Tannoy North America

T: 00 1 (519)

745 1158

E: inquiries@tannoyna.com

Tannoy Deutschland

T: 00 49

(180) 1111 881

E: anfragen@tannoy.com

Tannoy France

T: 00 33

(0)1

7036 7473

E: ventes@tannoy.com

 

 

 

 

 

‘07 22 Oct DATE: REVISION

0524 6481