TIMBERK AC TIM 12H W1E User Manual [ru]

0 (0)
TIMBERK AC TIM 12H W1E User Manual

Instruction manual

 

 

 

 

 

 

 

 

(

 

 

)

Electric Window Air Conditioner (one-body type)

/Models

( $ )

Electric Window Air Conditioner (one-body type)

AC TIM 05 W1M

AC TIM 07C W1M

AC TIM 09H W1E

AC TIM 12H W1E

17

18

Outlookof devices, aslo colour scores can be revised without any special advance notices.

CONTENTS

 

1. Important information............................................................................................................................

2

2. Saferty precautions...................................................................................................................................

2

3.Techincal characteristics..........................................................................................................................

3

4. Mobile conditioner description............................................................................................................

3

5.Window conditioner control..................................................................................................................

4

Control panel (for ACTIM 05C W1M, ACTIM 07CW1M models)............................................

5

Control panel (for ACTIM 09H W1E, ACTIM 12H W1E models).............................................

5

Remote control (only for ACTIM 09HW1E, ACTIM 12HW1E models).................................

6

6. Maintenance................................................................................................................................................

7

7. Service life.....................................................................................................................................................

8

8. Utilization rules...........................................................................................................................................

8

9.Tips...................................................................................................................................................................

8

10.Troubleshooting.......................................................................................................................................

9

Dear customer!

We thank you for your happy choice and buying of the electric window

air conditioner Timberk. It will serve you for a long time.

1.IMPORTANT INFORMATION

1.Please, read the manual carefully before installation and using of the window air conditioner.

2.In order to avoid damages of the conditioner and cancellation of your warranty, install the device vertically (as shown on the cover of this manual) at least 2 hours before operation.

3.There may be some misprints in the text and digital symbols of this manual.

4.If after reading of this manual you have any questions concerning operation of the device, please, address a vendor or a specialized service center for explanations.

5.The device has a label with all the necessary specifications and other useful information about the device.

6.Use the device only for its intended purpose set forth in this manual.

7.Before installation and plugging of the window conditioner, make sure that a socket outlet for the device has an earth contact and is earthed correctly.

8.If there is no earth circuit in your electric network, operation of the window conditioner is dangerous to life.

9.Do not use adapters and extension cords to plug your window air conditioner.

10.Incorrect installation and use of this conditioner may result in serious traumas or damage to your property.

11.All the service operations should be performed by a specialized organization and qualified specialists.

2.SAFETYPRECAUTIONS

1.Do not close vent holes!

2.Make sure than vent inlet and outlet are free.

3.Do not tuck foreign objects into air-outlet gratings of the conditioner. It is very dangerous, since the fan rotates at high speed.

4.Install the appliance on the level in order to avoid leaking of condensate (water).

5.Do not install the conditioner in the following places:

-near open flames;

-near working heating appliances;

-near swimming pools, bathrooms and shower rooms.

6. Do not use the appliance in explosive or corrosive environment. Do not keep gasoline or other volatile flammable liquids near the conditioner it is very dangerous!

7.Use the appliance in cooling mode to maintain the room temperature of 17-32°

8.Clean filters occasionally to ensure the efficient operation of the appliance.

9.To avoid the reliable operation of compressor, do not incline the conditioner.

10.If the appliance is off, it should be restarted not earlier than in 3.5 minuets in order to avoid breakdown of the compressor.

11.Operation of the compressor requires current of at least 10 A. In order to avoid overheating or risk of fire, as well as damage of internal electric network, do not plug the appliance with the use of extension cords.

12.The appliance is designed for air cooling, drying and ventilation only in domestic conditions and cannot be used for industrial purposes.

13.In order to avoid the danger of electric shock, damaged power cord should be replaced only in authorized service centers of the manufacturer by qualified specialists.

14.Before utilization of the appliance it is necessary to remove batteries from the remote control and after that they are subject to safe utilization.

15.Connect the conditioner only to 220-230V 50 Hz network. If needed, find out specifications of your network from power suppliers.

16.The appliance is not designed for use by persons (including children) with limited physical, sensory or intellectual capabilities, with insufficient experience and knowledge, if they are not under supervision or were not instructed in use of the appliance by a person responsible for their safety. It is necessary to watch that children do not play with the appliance.

2 www.timberk.com Electric window air conditioner (one-body type)

ENGLISH

3. TECHINCAL CHARACTERISTICS

 

 

 

 

 

 

 

Table 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

Model

AC TIM 05C W1M

AC TIM 07C W1M

AC TIM 09H W1E

AC TIM 12H W1E

 

 

 

 

 

 

 

 

 

 

 

 

Power (cooling) BTU (kW)

5000 (1,46)

7000 (2,0)

9 000 (2,5)

12 000 (3,2)

 

 

 

 

 

Power input (cooling)

542

752

1000

1300

 

 

 

 

 

Supply voltage V/Hz

220/50

220/50

220/50

220/50

 

 

 

 

 

Amperage (cooling) А

2,6

3.3

4.8

5.8

 

 

 

 

 

Air flow m3/h

220

380

380

550

 

 

 

 

 

Noise level dB(А)

43-61

50-59

50-59

50-60

 

 

 

 

 

Freon type

R410A

R410A

R410A

R410A

 

 

 

 

Energy-efficiency class (cooling/heating)

A

A

B

B

 

 

 

 

 

 

 

 

 

 

 

 

Electrical-protection class

I

I

I

I

 

 

 

 

 

Level of moisture protection

IP24

IP24

IP24

IP24

 

 

 

 

 

Net weight (kg)

18,0

27,0

27,0

38,0

 

 

 

 

 

Gross weight (kg)

20,0

32,0

32,0

45,0

 

 

 

 

 

Device size (mm)

410×300×344

482×340×510

482×340×510

610×385×536

 

 

 

8

7

Packed size (mm)

480×400×380

560×560×380

560×560×380

695×580×428

 

 

 

Fig.1

NOTE

The manufacturer reserves the right to make modifications in design, delivery set and manufacturing technology of the product and to change its technical characteristics without prior notification with a view to improve its consumer and technical properties.

DELIVERY SET

1.Domestic conditioner 1

2.Remote control* (batteries are not attached, 1.5 V batteries

U 4 M MR:03 are needed) 1

3. Drainage tube 1

*- only for AC TIM 09H W1E, AC TIM12H W1E models

4. MOBILE CONDITIONER DESCRIPTION

(Fig.1)

1.Air filter

2.Horizontal gills

3.Vertical gills

4.Air-inlet grating

5.Direction-control switch for gills

6.Control panel

7.Compressor operation lamp

8.Air-inlet grating

3

4

5

6

www.timberk.com Electric window air conditioner (one-body type)

3

5.WINDOW CONDITIONER CONTROL

Control panel (for ACTIM 05CW1 , ACTIM 07CW1M models) (fig.2)..

1. Mode selection switch (left-right)

Turn off

central position of a knob

OOL (

) work for cooling (low speed)

OOL (

) work for cooling (middle speed)

OOL (

) work for cooling (high speed)

FAN (

)

ventilation (low speed)

FAN (

)

ventilation (middle speed)

FAN (

)

ventilation (high speed)

3. SWING ON/OFF push button to activate and deactivate gill swinging

Fig.2

4

www.timberk.com Electric window air conditioner (one-body type)

Control panel of AC TIM 09HW1E, AC TIM 12HW1E.

8

4

3

2

1

. 3

7

6

5

ENGLISH

Control panel (for ACTIM 09HW1 , ACTIM 12HW1 models)

(fig.3)

1.POWER button. Press to turn the appliance on or off.

2.On/off button of the programmable timer. Turn-on timer. The turn-on timer is used for automatic turning on of the appliance upon expiration of the set time interval. Press the timer button, when the device if off, to set the needed time (buttons 4 and 5). The appliance will automatically turn on upon expiration of the set time interval.

Before expiration of the set time interval press the POWER button. Setting of time will be cancelled and the appliance will turn on.

Turn-off timer. The turn-off timer is used for automatic turning off of the appliance upon expiration of the set time interval.

3. SWING button. Press this button to regulate swinging of the gill in automatic mode.

4,5. TEMP button (increase/decrease). This button is used to set the needed air temperature in the room.

6.SPEED button. Press this button to select the fan rotation speed:

-high speed

-middle speed

-low speed

7.SET button. Press this button to select ventilation, drying or cooling mode.

- drying mode

- ventilation mode

- cooling mode

8. LCD display. It displays the set temperature or time of the timer. After temperature and time are set, the display returns to displaying of current temperature.

www.timberk.com Electric window air conditioner (one-body type)

5

Press the timer button, when the device is on, to set the needed time (buttons 4 and 5).

The appliance will automatically turn off upon expiration of the set time interval. Press the ON/OFF button before expiration of the set time interval. Setting of time will be cancelled and the appliance will turn off.

Indicators of control panel:

- cooling mode

- drying mode

- ventilationmode

( -high speed, - middle speed, - low speed)

Remote control (only for AC TIM 09H W1 , AC TIM 12H W1 models)

12

7

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

9

 

 

 

 

 

14

 

 

 

 

 

 

 

6

12

 

 

 

 

 

 

13

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

5

 

 

 

 

 

3

 

 

Fig. 4

1, 2. TEMP buttons:

Set temperature raises by 1° after single pressing of "+" key and lowers by 1° after single pressing of "-" key.

3.POWER button: this button is used to turn the device on and off.

4.SLEEP button: After pressing of this button, the fan switches to low speed. Press this button and the conditioner sound will lower.

5.Timer button: TURN-ON TIMER: The turn-on timer is used for automatic turning on of the appliance upon expiration of the set time interval.

(1)Press the TIMER button, when the device is off, to set the needed time.

(2)The appliance will automatically turn on upon expiration of the set time interval.

(3)Press the ON/OFF button before expiration of the set time interval. Setting of time will be cancelled and the appliance will turn on.

TURN-OFF TIMER: The turn-off timer is used for automatic turning off of the appliance upon expiration of the set time interval.

(1)Press the TIMER button, when the device is on, to set the needed time.

(2)The appliance will automatically turn off upon expiration of the set time interval.

(3)Press the ON/OFF button before expiration of the set time interval. Setting of time will be cancelled and the appliance will turn off.

6.AUTO key. Press this button and the conditioner will automatically maintain the room temperature of +25oC

7.High speed key. High speed of the fan.

8.Middle speed key. Middle speed of the fan.

9.Low speed key. Low speed of the fan.

10.COOL button. Press this button and the conditioner will start working in cooling mode.

11.DRY button. Press this button and the conditioner will start working in drying mode.

12.SWING button. Press this button and the conditioner gills will start swinging automatically.

13.HEAT bgutton. Press this button and the conditioner will start working in heating mode.*

14.FAN button. Press this button and the conditioner will start working in ventilation mode.

*not used for these models

6

www.timberk.com Electric window air conditioner (one-body type)

ENGLISH

6. MAINTENANCE

ATTENTION!

Unplug the device before cleaning.

1.Do not clean the conditioner with gasoline, solvents, cleaning powders or other chemically active substances.

2.In order to avoid electric shock and damage of electric components, do not pour water on the conditioner.

3.Do not operate the conditioner with damaged power cord.To replace the damaged power cord, please, address to an authorized service center.

Air filter

Clogging of the air filter with dust particles decreases efficiency of the conditioner work.Therefore, clean the filter at least once per two weeks.

Filter removal/installation

Remove the air filter in accordance with direction shown with an arrow. Push it and then remove from the appliance for cleaning. (See fig. 5).

Fig. 5

www.timberk.com Electric window air conditioner (one-body type)

7

Installation of the filter is performed in reverse order.

Filter cleaning

First, clean the filters carefully with the use of vacuum cleaner. Then put the filter in warm water (with the temperature of about 40° ) with soft detergent, wash it and dry without exposing it to direct sunlight.

Air-inlet holes (heat exchangers)

Clean them with the use of vacuum cleaner.

Body frame

Wipe the surface with wet cloth and dry with soft dry cloth.

7. SERVICELIFE

Service life of the device is 10 years subject to observance of the respective installation and operation regulations.

Manufacture date of the conditioner is indicated in a serial number of the device. For detailed information, please, ask a vendor.

8. UTILIZATION RULES

Upon completion of its service life the device should be utilized in accordance with norms, rules and procedures effective in a place of utilization.

9.TIPS

Since the appliance may heat up, while working, do not install it in places with restricted free space.

In case of dangerous current leakage do not use the appliance in conditions of high humidity.

The appliance has a function of automatic temperature shutdown. In such a case let the appliance cool and then it may be put into service again.

Do not place the appliance near objects hindering air access, e.g. furniture or curtains, since it seriously affects the appliance operation.

ELECTRIC POWER SUPPLY

Make sure that network specifications correspond to the appliance characteristics.

Plug the device securely in order to avoid overheating and a possibility of fire.

Do not pull the power cord with force: it may damage it.

8

www.timberk.com Electric window air conditioner (one-body type)