Timberk AC TIM 09H P4 User Manual [ru]

0 (0)

Instruction manual

 

 

 

Electric floor

 

 

 

standing air

 

 

onditioner ortable

 

(

)

type (single case)

/Models

% & (' )

Electric floor air conditioner portable type (single case)

AC TIM 05H P4

AC TIM 07H P4

AC TIM 09H P4

AC TIM 09HE P4

17

18

Outlookof devices, aslo colour scores can be revised without any special advance notices.

1.Important information.........................................................................................................

2

2.Precautions................................................................................................................................

2

3.Technical characteristics......................................................................................................

3

4.Description of portable air conditioner......................................................................

4

5.Control of portable air conditioner.................................................................................

5

Control panel (for AC TIM 05H P4, AC TIM 07H P4, AC TIM 09H P4).................

5

Control panel (for AC TIM 09HE P4)....................................................................................

5

Remote control (for AC TIM 09HE P4)...............................................................................

6

6.Maintenance............................................................................................................................

7

7.Service life..................................................................................................................................

8

8.Rules of disposal......................................................................................................................

8

9.Helpful advice..........................................................................................................................

8

10.Troubleshooting...................................................................................................................

10

Dear Customer!

Thank you for a shrewd choice and purchase ofTimberk portable electric air conditioner.

It will serve you for a long time.

1. IMPORTANT INFORMATION

1.Please read this instruction manual carefully prior to installation and operation of a portable air conditioner.

2.To avoid damage to the air conditioner and voiding your guarantee, before start using the air conditioner put the device in a vertical position (as shown on the cover of this instruction manual) for at least 2 hours prior to operation.

3.There may be misprints in the text and digital symbols in this manual.

4.If after reading the manual you would still have questions regarding functioning and operation of the device, please contact the seller or a specialized service center for clarifications.

5.The device has a tag indicating all necessary technical data and other useful information about the device.

6.Use the device only as designated by this manual.

7.Prior to installation of the portable air conditioner, not connecting it to the mains, check and make sure that the mains socket for the air conditioner has a grounding pin and is properly grounded.

8.In case there is no grounding pin in your mains, operation of the portable air conditioner is life-threatening.

9.Do not use adapters and extension cords to connect your portable air conditioner.

10.Improper installation and use of this air conditioner may lead to severe injuries or damage to your property.

11.Any maintenance must be performed by a specialized company and qualified specialists.

2.PRECAUTIONS

1.Do not block vents!

2.Make sure the inlet and outlet vent is not blocked.

3.Do not insert foreign objects into the air diffuser of the air conditioner. It is very dangerous since the fan rotates at high speed.

4.Install the device only on a horizontal surface to prevent condensed water leakage.

5.Do not install the floor-mounted air conditioner in the following places:

-in places exposed to direct sunlight;

-in the vicinity of open fire sources;

-in the vicinity of other operating heating devices;

-in places where water or steam splashes can contact the device;

-in rooms with increased humidity;

-close to swimming pools, bathrooms and shower rooms.

6.Do not use the device in an explosive or corrosive environment. Do not store gasoline and other volatile flammable liquids near the air conditioner

it is very dangerous!

7.Use the device to cool down air at ambient temperature 17-32°C. To use the device as a heater the room temperature must be 5-23°C.

8.Regularly clean filters to ensure efficient operation of the device.

9.To ensure reliable operation of the compressor, do not tilt the air conditioner.

10.If the device is disconnected, restarting must be performed not sooner than in 3.5 minutes to prevent the compressor failure.

11.At least 10 A current is required for the compressor to operate. To avoid overheating and fire risk, as well as damage to the inner electrical circuit, do not connect the device through extension cords.

12.The device is designed to cool, heat and dry air only in residential conditions and cannot be used for industrial purposes.

13.To avoid electric shock, a damaged power cord must be replaced only by an authorized service center and qualified specialists.

14.Prior to disposal of the device, it is necessary to remove batteries from it, after that they can be safely disposed.

2

www.timberk.com electric floor standing air onditioner ortable type (single case)

15.Connect the air conditioner only to 220-230 V 50 Hz mains. If necessary, ask your power suppliers to give characteristics of your mains.

16.The appliance is not intended for use by children and persons with reduced physical, sensory or mental capabilities, or a lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by an individual responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

IMPORTANT!

Efficient heating and cooling require to:

1)Ensure at least 50 cm of free space on the filtering side of the unit (Fig. 1).

2)Extend the air duct not more than 400 mm. The hose must be located in parallel to the surface. It is forbidden to fold the hose! (see Fig. 2)

3)Upon defreezing a DF-symbol is indicated on the display screen

(except for AC TIM 05 P4, AC TIM 07 P4, AC TIM 09H P4).

Fig. 1

Fig. 2

ENGLISH

3.Technical characteristics

Tab.1

Наименование

AC TIM 05H P4

AC TIM 07H P4

AC TIM 09H P4

AC TIM 09HE P4

Capacity (cooling), Wh(kW)

5000 (1,5)

7000 (2,0)

9000 (2,6)

9000 (2,6)

Capacity (heating), Wh(kW)

5000 (1,5)

7000 (2,0)

9000 (2,6)

9000 (2,6)

Power consumption (cooling), W

650

900

1100

1100

Power consumption (heating), W

500

700

950

950

Supply voltage V/Hz

220/50

220/50

220/50

220/50

Current (cooling/heating), A

3,0/2,3

4,1/3,2

5,0/4,3

5,0/4,3

Air flow m3/h

280

280

360

360

Dehumidification capacity, I/day

25

30

50

50

Noise level, dB(A)

50

50

52

52

Refregerant

R410

R410

R410

R410

Energy efficiency class

B

B

B

B

(cooling/heating)

 

 

 

 

Electrical protection

I class

I class

I class

I class

Degree of moisture protection

IPХ0

IPХ0

IPХ0

IPХ0

Net weight, kg

22,0

22,5

23,0

23,0

Gross weiht, kg

23,5

24,0

24,5

24,5

Device dimensions, mm

300x455x630

300x455x630

300x455x630

300x455x630

Package dimensions, mm

330x485x660

330x485x660

330x485x660

330x485x660

NOTICE.

The manufacturer reserves the right to make changes in the design, scope of delivery, product manufacturing technology, as well as change its technical characteristics to improve its consumer and technical properties without prior notice.

SCOPE OF DELIVERY

1.Household air conditioner 1 pc.

2.Remote control* (batteries are not supplied, 1,5V UM4 AAA CR03 batteries are required) 1 pc.

3.The adapter for air duct 1 pc.

4.Air outlet hose 1 pc.

5.Removable grille 1 pc.

* - only for AC TIM 09HE P4.

www.timberk.com electric floor standing air onditioner ortable type (single case)

3

Timberk AC TIM 09H P4 User Manual

(4)

(5)

(1)

(8)(9)

(3)

(2)

 

 

 

 

 

(6)

(10)

 

 

 

 

(12)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(7)

 

 

(11)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 3

 

 

Fig. 4

4. DEVICE DESCRIPTION (Fig. 3 and 4)

1.Control panel

2.Air-outlet

3.Removable grille

4.Nozzle

5.Air duct

6.Air inlet grille

7.Condensation drain hole

8.Place for remote control

9.Adapter of air duct

10.Air outlet

11.Condensation drain hole

12.Air inlet grille

Installation of air outlet hose (Fig. 5)

1.Prior to operation of the unit take off the removable cover and get the air outlet hose, then insert it in the hole.

2.Rotate the air outlet hose in the direction, indicated by arrow 2 and take it out from the removable grill.

3.Rotate the air outlet hose in the direction, indicated by arrow 3 and connect it to the removable grill.

Fig. 5

Installation of the hose in cooling / heating modes (Fig. 6)

To switch the air conditioner to heating it is necessary to install the hose to the side, where cold air is coming out. To switch the air conditioner to cooling it is necessary to install the hose to the side, where warm air is coming out.

To switch the unit to the required mode (cooling/heating):

Disconnect the removable grill and the air outlet hose, as shown by the arrow in Fig. 6 A, then interchange their position (B) and connect to the unit. Final structure is shown in Fig.6 C.

A B C

Fig. 6

4

www.timberk.com electric floor standing air onditioner ortable type (single case)

ENGLISH

5. CONTROL OF PORTABLE AIR CONDITIONER

Control panel for ACTIM 09HE P4 (Fig. 8)

Control panel (for AC TIM 05H P4, AC TIM 07H P4, AC TIM 09H P4) (Fig. 7).

1. POWER button. Press this button to switch on or off the unit.

1. Mode switch (Right-left)

2. SET button. Press this button to select the mode of heating,

Switch off

central position of the handle

dehumidification or cooling.

3. TEMP up button. In the cooling mode each press of this button raises the

COOL/HEAT [

] cooling / heating mode (low speed)

set temperature by 1°C up to maximum 30°C. In the heating mode each

COOL/HEAT [

] cooling / heating mode (high speed)

press of this button raises the set temperature by 1°C up to maximum 25°C.

FAN SPEED [

] ventilation mode (low speed)

4. TEMP down button. In the cooling mode each press of this button lowers

FAN SPEED [

] ventilation mode (high speed)

the set temperature by 1°C up to minimum 17°C. In the heating mode each

2. FULL Condensate fill-up tank indicator. If this indicator is on then the

press of this button lowers the set temperature by 1°C up to minimum 15°C.

condensate collection tank is full. It is necessary to switch off the unit and

5. LED display. The display shows the set temperature or the timer. After the

drain the condensate by unscrewing the plug on pipe 11 (Fig. 4), then the

temperature and time are set the display returns to indicating the current

unit can be switched on again.

temperature.

3. POWER

air conditioner operation indicator.

6. FAN speed button. Press this button to select low [ ], medium [ ],

Control panel for AC TIM 05H P4, AC TIM 07H P4, AC TIM 09H P4

high [ ] or automatic [ ] fan speed button. When the automatic speed is

selected (in the cooling mode), high, medium or low speeds are selected

 

 

 

 

 

 

automatically depending on the difference between the set temperature

 

 

 

and the room temperature.

NOTICE.

You should not set the fan speed in the heating or dehumidification mode since heating is performed at high fan speed and dehumidification is performed at low fan speed.

 

 

 

 

 

 

 

 

 

 

7. Programmable timer on/off button.

 

 

 

 

 

 

 

 

 

 

ON timer. The ON timer is used to automatically switch on the unit upon

 

Fig. 7

 

 

expiration of the set time.

 

 

 

Press the timer button when the unit is not operating to set the desired time

 

Control panel for AC TIM 09HE P4

 

 

(buttons 3 and 4).

 

 

 

The unit will be automatically switched on when the set time expires.

 

 

 

 

 

 

 

 

 

 

Press POWER button before the set time expires. Time setting will be

7

 

 

 

 

 

 

 

8

canceled and the unit will be switched on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF timer. The OFF timer is used to automatically switch off the unit upon

5

 

 

 

 

 

 

 

 

 

expiration of the set time.

 

 

 

 

 

 

 

 

 

Press the timer button when the unit is operating to set the desired time

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

2

(buttons 3 and 4).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The unit will be automatically switched off when the set time expires.

1

 

 

 

 

 

 

 

 

 

Press ON/OFF button before the set time expires. Time setting will be

3

 

 

 

 

 

 

 

 

4

canceled and the unit will be switched off.

 

 

 

 

 

 

 

 

8. SLEEP button: after pressing this button the fan sets to low speed.

 

 

 

 

 

 

 

 

 

 

(1) Press SLEEP button, set the sleep mode. Press the button again to cancel

the sleep mode.

Fig. 8

www.timberk.com electric floor standing air onditioner ortable type (single case)

5

(2)In the cooling mode one hour after the sleep mode is set the temperature automatically increases by 1°C. In two hours the temperature will increase by 2°C and the established mode is maintained for the rest of the time. In the heating mode when SLEEP function is activated the temperature is, on the contrary, decreased by 2°C in 2 hours.

(3)When power supply is turned off, the sleep mode is automatically switched off.

(4)When the unit is turned off, settings of the sleep mode are automatically turned off.

The portable air conditioner is equipped with a protective circuit featuring a 3 minute compressor activation delay. It means that it takes 3.5 minutes for the compressor to activate after the unit is switched on or dehumidification mode is switched to any other mode.

9. Signaling.

E4 signal is shown on the display at the maximum water level. To resume operation, remove the rubber plug of the drainage hose at the device's base to drain water at first. After water is drained, start the unit. It will go to the normal operating mode.

Indicators for operating mode:

- cooling mode indicator

- heating mode indicator

- dry mode indicator

- sleep mode indicator - operation indicator

Remote control (only for AC TIM 09HE P4)

5

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

6

 

 

 

 

 

 

1

 

 

 

 

7

 

 

 

 

 

9

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 9

1. FUNC mode selection button (SET):

You can select three functions with this button: cooling, heating and dehumidification.

2.Room temperature setting button (TEMP): The set temperature is raised by 1°C after a single press on up button and is lowered by 1°C after a single press on down button.

3.POWER button: pressing this button you can switch on or off the unit.

4.SLEEP button: after pressing this button the fan sets to low speed.

(1)Press SLEEP button, set the sleep mode. Press the button again to cancel the sleep mode.

(2)In the cooling mode one hour after the sleep mode is set the temperature automatically increases by 1°C. In two hours the temperature will increase by 2°C and the established mode is maintained for the rest of the time. In the heating mode when SLEEP function is activated the temperature is, on the contrary, decreased by 2°C in 2 hours.

(3)When power supply is turned off, the sleep mode is automatically switched off.

(4)When the unit is turned off, settings of the sleep mode are automatically turned off.

5.Timer button: ONTIMER:The ON timer is used to automatically switch on the unit upon expiration of the set time.

(1)PressTIMER button when the unit is OFF to set the desired time.

(2)After the set time expires, the unit will be automatically switched on.

(3)Press ON/OFF button before the set time expires. Time setting will be canceled and the unit will be switched on.

OFF TIMER: The OFF timer is used to automatically switch off the unit upon expiration of the set time.

(1)PressTIMER button when the unit is ON to set the desired time.

(2)After the set time expires, the unit will be automatically switched off.

(3)Press ON/OFF button before the set time expires. Time setting will be canceled and the unit will be switched off.

6.Automatic fan speed button (automatic ventilation mode).

7.High speed button. High fan speed.

8.Medium speed button. Medium fan speed.

9.Low speed button. Low fan speed.

6

www.timberk.com electric floor standing air onditioner ortable type (single case)

ENGLISH

NOTICE.

The unit can evaporate condensed water and automatically drain it through the hose.

1.When the unit is in cooling mode, it is not necessary to install the condensate drainage pipe since condensate evaporates automatically. Make sure that when the unit is operating, the rubber plug of the drainage hose is securely fixed (see Fig. 10).

2.In heating mode, remove the rubber plug (2) of the drainage hose (Fig. 10), install the respective drainage hose to improve heating efficiency.

3.In dehumidification mode, remove the rubber plug (2) of the drainage hose, install the respective drainage hose.

Disconnect the air outlet hose, connect the drainage hose to the drainage hole and drain water from the unit to ensure maximum dehumidification efficiency.

E4 signal is shown on the LED display at the maximum water level (for AC TIM 09HE P4). As for AC TIM 05H P4, AC TIM 07H P4 and AC TIM 09H

P4 FULL indicator is on in this case.

To resume the operation, remove the rubber plug (2) of the drainage hose to drain water at first. After water is drained, turn the unit on, the unit will resume operation

Fig. 10

6. Maintenance

IMPORTANT!

Disconnect the unit from the mains prior to cleaning.

1.When cleaning the air conditioner, do not use gasoline, solvents and other chemically active substances.

2.To avoid electric shock and damage to electrical components, do not pour water on the air conditioner from a tap or a hose.

3. Do not use the air conditioner if the power cord is damaged. On the subject of replacing a damaged power cord, contact an authorized service center.

Air filter

Air filter clogging with dust particles impairs the air conditioner operation efficiency, therefore clean the filter no less than once in two weeks.

Filter removal/installation

Remove the air filter in the direction, indicated by the arrow. Slightly push it and then take it out from the device for cleaning. (See Fig. 11).

Fig. 11

Installation of the filter is performed in the reverse order.

Filter cleaning

At first, carefully clean the filters by means of vacuum cleaners. Then immerse the filter in warm water (about 40°C) with a soft detergent, wash it and dry it without exposure to direct sunlight.

Air intakes (heat exchangers)

Use a vacuum cleaner for cleaning.

Case

Wipe the surface by a damp cloth and dry it by a soft dry cloth.

Automatic condensate removal

Condensate is automatically removed from the unit. Moisture inside the unit starts to evaporate and is removed from the unit through an air duct (or an air diffuser) in the form of steam.

www.timberk.com electric floor standing air onditioner ortable type (single case)

7

7. SERVICE LIFE

Service life of the unit is 10 years provided respective installation and operation rules are followed.

Date of manufacture of the air conditioner is indicated on the unit in the serial number. Contact the seller for additional information.

8. RULES OF DISPOSAL

After service life is expired, the unit must be disposed in compliance with rules, regulations and methods effective at disposal stations.

9. HELPFUL ADVICE

Since the unit may heat when operated, do not install it in places with limited free space.

In case of a dangerous current leakage, do not use the unit at high humidity. Keep the unit away from direct sunlight: its paint may fade.

The unit has a function allowing it to be switched off automatically at a certain temperature, in this case let the unit cool down, after that it can be switched on again.

Do not position the unit nearby objects that block air flow, for example, furniture or curtains since it has a great impact on operation of the unit. Keep the unit away from direct sunlight: it may cause overheating and shutdown of the unit.

ELECTRIC POWER SUPPLY

Make sure characteristics of the mains correspond to characteristics of the unit.

Insert the plug in the socket securely to avoid overheating and risk of fire. Do not pull the power cord with excessive force: it may damage it.

IMPORTANT!

At high humidity additional condensate removal will be required ( FULL indicator will go on for AC TIM 05H P4, AC TIM 07H P4, AC TIM 09H P4 models; E43symbol will be shown on the display for AC TIM 09HE P4 model). In this case a condensate collection tank at the device's base is used.

In this case follow the instructions given below.

When the condensate collection tank is filled up, water needs to be drained, otherwise the unit will not operate. Condensate should be drained by opening the lower plug at the device's base (Fig. 10 pos. 2).

But air conditioners are also designed to remove condensate continuously without a need for a regular moisture removal from the device. To do so it is necessary to use the drainage hose and perform the following procedure:

1.Prepare the drainage hose for condensate removal;

2.Remove the plug from the back side of the device;

3.Insert the drainage hose into the condensate drainage hole;

4.Take the hose out to the drainage system to remove condensate; A hole designed for continuous condensate removal in the center of the device (Fig. 10 pos. 1) can be used for continuous condensate removal under conditions of increased humidity inside a room.

To do so it is also necessary to perform the abovementioned procedure.

8

www.timberk.com electric floor standing air onditioner ortable type (single case)