FIGURE3 VCH54MountingPlate
(not to scale) Top View
FIGURE4
2.Prepare cabinet or soffit by tapping holes for mounting filterhousings.Figure2andFigure3showthetopviewof the VCH36 and VCH54 respectively. Each figure shows mounting hole locations, overall size of filter housing mountingplate,andrequiredclearanceforthetransition. See Figure 4 for the clearance required for the PLENUM transitionintheVCH54installation.
3.Attachtransitiontofilterhousingandsealwithducttape. The VCH36 requires the VCHTR10 transition. The VCH54 requirestheVCHTR10andPLENUMtransitions.
4.Attach filter housing to prepare cabinet/soffit surface usingwoodscrewsprovided.Theinstallationrequirestwo people due to the size of the unit.
5.ELECTRICALCONNECTIONSVCH36forVCH54
A)Power supply must be rated for 120V, 60Hz, 15 amps(minimum).
FIGURE5
Light
Controller Power
Supply
N L G
B |
G |
W |
|
|
75 Watt |
75 Watt |
Lamp |
Lamp |
VCH36 Wiring (VCH54 has three 75-watt lamps)
B)Remove junction box cover. Connect black wire #2 to powersupplyblackwire.Connectwhitewire#1topower supply white wire. Connect green ground wire to power supplygreenwire.Usespringtypewirenuts(BSH#189692) supplied. (Lost or missing wire nuts should only be replacedwith:Springtypewirenuts,ratedforaminimum of(2)#18gawiresandamaximumof(4)#14gawires,UL &CSAratedto600Vand302F/150).SeeWiringDiagram, Fig. 5.
C)Be sure that junction box cover is replaced properly.
D)The light switch must be UL listed general switch and is supplied by the electical contractor.
6.For remote blower application see wiring instruction included with the VTR600, VTR1000 & VTR1400. Note: BlowerswitchCTR3Qmustbeinstalledtocontrolremote blower.
BSH reserves the right to change specifications or design without notice. Some models are certified for use in Canada. BSH is not responsible for products which are transported from the United States for use in Canada. Check with your local Canadian distributor or dealer.
5551 McFadden Avenue, Huntington Beach, CA 92649 • 800/735-4328
5060010149 Rev. A (ECO# 5V01LF) • BSH Home Appliances Corp.© 2003 • Litho in U.S.A. 09/03
Page 4
INSTALLATIONINSTRUCTIONS
VCH36 OR VCH54
FORRESIDENTIALUSEONLY
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT:SavetheseinstructionsfortheLocalElectricalInspector’suse.
INSTALLER:PleaseleavetheseInstallationInstructionswiththisunitfortheowner.
OWNER:Pleaseretaintheseinstructionsforfuturereference.
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
|
|
WARNING: TO RE- |
|
C. Installation work and electrical wiring |
E. When cutting or drilling into wall or |
||||
|
|
DUCETHERISKOFFIRE, |
|
must be done by qualified persons in |
|
ceiling, do not damage electrical wiring |
|||
|
|
|
accordance with all applicable codes & |
|
and other hidden utilities. |
||||
|
ELECTRIC SHOCK, OR IN- |
|
|
||||||
|
|
standards,includingfire-ratedconstruc- |
|
|
|
||||
|
|
|
|
F. CAUTION: To reduce risk of fire and to |
|||||
|
JURY TO PERSONS, OB- |
|
tion. |
|
|
||||
|
SERVE THE FOLLOWING: |
|
|
|
|
|
properly exhast air, be sure to duct air |
||
|
|
D. Sufficient air is needed for proper com- |
|
outside. Do not vent exhaust air into |
|||||
|
|
|
|
|
|||||
|
|
CAUTION-FORGENERAL |
bustionandexhastingofgasesthrough |
|
spaces within walls, celinings, attics, |
||||
|
|
theflue(chimney)offuelburningequip- |
|
crawl spaces or garages. |
|||||
|
|
VENTILATINGUSEONLY.DO |
|
||||||
|
|
menttopreventbackdrafting.Followthe |
|
|
|
||||
|
|
NOTUSETOEXHAUST |
|
|
|
||||
|
|
heatingequipmentmanufacturersguide- |
|
|
|
||||
|
HAZARDOUSOREXPLOSIVE |
|
G.WARNING-TOREDUCE |
|
|||||
|
line and safety standards such as those |
|
|
||||||
|
|
MATERIALSORVAPORS. |
|
THE RISK OF FIRE, USE |
|
||||
|
|
publishedbytheNationalFireProtection |
|
|
|||||
|
|
|
|
|
ONLY METAL DUCT WORK. |
|
|||
A. Usethisunitonlyinthemannerintended |
Association (NFPA), the American Soci- |
|
|
||||||
ety for Heating, Refrigeration and Air |
|
|
|
||||||
|
by the manufacturer. If you have ques- |
|
|
|
|||||
|
H. Install this hood in accordance with all |
||||||||
|
Conditioning Engineers (ASHRAE), and |
||||||||
|
tions,contactthemanufacturer. |
||||||||
|
the local code authorities. |
|
requirements specified by the manufac- |
||||||
|
|
|
|
|
|||||
B. Before servicing or cleaning unit, switch |
|
|
|
|
turer of your cooktop/range |
||||
|
power off at service panel and lock the |
|
|
|
|
|
|
||
|
service disconnecting means to prevent |
|
|
WARNING - TO REDUCE THE RISK OF IN- |
|
||||
|
power from being switched on acciden- |
|
|
|
|||||
|
|
|
JURY TO PERSONS IN THE EVENT OF A |
|
|||||
|
tally. When the service disconnecting |
|
|
|
|||||
|
|
|
RANGETOPGREASEFIRE,OBSERVETHEFOL- |
|
|||||
|
meanscannotbelocked,securelyfasten |
|
|
|
|||||
|
a prominent warning device, such as a |
|
|
LOWING: |
|
|
|
||
|
tag, to the service panel. |
|
|
A. SMOTHER FLAMES with a close-fitting lid, cookie |
|
||||
|
|
|
|
|
|
sheet, or metal tray, then turn off the burner. BE |
|
||
|
|
|
|
|
|
|
|||
|
|
WARNING - TO REDUCE THE RISK |
|
CAREFULTOPREVENTBURNS. If the flames do |
|
||||
|
|
|
notgooutimmediately,EVACUATEANDCALLTHE |
|
|||||
|
|
OF A RANGE TOP GREASE FIRE: |
|
|
|||||
|
|
|
FIRE DEPARTMENT. |
|
|||||
|
|
|
|
|
|
|
|||
|
|
A. Never leave surface units unattened at high |
|
B. NEVER PICK UP A FLAMING PAN - You may be |
|
||||
|
|
settings. Boilovers cause smoking and greasy |
|
|
|||||
|
|
|
burned. |
|
|
|
|||
|
|
spilloversthatmayignite.Heatoilsslowlyonlow |
|
|
|
|
|||
|
|
|
|
|
|
|
|||
|
|
or medium settings. |
|
|
C. DONOTUSEAWATER,includingwetdishclothsor |
|
|||
|
|
|
|
|
|
|
|||
|
|
B. AlwaysturnhoodONwhencookingathighheat |
|
towels-aviolentsteamexplosionwillresult. |
|
||||
|
|
|
|
|
|
|
|||
|
|
or when cooking flaming foods. |
|
|
D. Use an extinguisher ONLY if: |
|
|||
|
|
|
|
|
|
|
|||
|
|
C. Cleanventilatingfansfrequently.Greaseshould |
|
1)YouhaveaClassABCextinguisher,andyoualready |
|
||||
|
|
|
know how to operate it. |
|
|||||
|
|
not be allowed to accumulate on fan or filter. |
|
|
|||||
|
|
|
2)Thefireissmallandcontainedintheareawhereit |
|
|||||
|
|
|
|
|
|
|
|||
|
|
D. Use proper pan size. Always use cookware |
|
started. |
|
|
|
||
|
|
|
3) The fire department is being called. |
|
|||||
|
|
appropriate for the size of the surface element. |
|
|
|||||
|
|
|
4) You can fight the fire with your back to an exit. |
|
|||||
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Page 1 |
|
|
|
VCH36/VCH54FilterHousingDescriptions |
Aremotemountedventilatorunit,VTR600R,VTR1000Q |
|
|
1-1/2" Diadiam. |
FilterHousingSideView |
||||
|
|
|
|
|
|
|
|||
Thesefilterhousingshavebeenspeciallydesignedto |
or VTR1400Q must be purchased separately. The ventila- |
|
|
|
1-3/4" |
||||
tors require a separate speed control unit, CTR 3Q (pur- |
|
|
|
||||||
meet the ventilating requirements of our gas and electric |
10--7/8" |
|
|
1-3/4" |
|||||
chased separately), and a light switch or light dimmer |
|
1- |
|
||||||
cooktops.Eachventilatorunitincludesafilterhousingand |
|
|
1-1/4" |
11-3/4"- |
|||||
switch (supplied by the electrical contractor). The VCH54 |
|
12--1/4" |
1-1/4" |
||||||
lights mounted on the mounting plate. |
|
|
|||||||
|
|
||||||||
unitrequiresatransitionmodelPLENUM(soldseparately). |
|
|
|
|
|||||
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
||
VCH36 |
|
|
|
|
|
|
|||
|
|
|
|
VCH54 |
|
|
|
|
|
|
|
|
|
|
|
|
|
FIGURE1B
VCH36Requires: |
VCH54Requires: |
|
|
|||
• VTR600R, VTR1000Q, VTR1400Q (or equivalent)* |
• VTR600R, VTR1000Q, VTR1400Q (or equivalent)* |
|
1. TheVCH36/VCH54aredesignedtobe |
|||
•VCHTR10Transition* |
•VCHTR10Transition* |
|
installedinacustomhoodasshowninFigure |
|||
• CTR3Q Control* |
• CTR3Q Control* |
|
1A.Designofthehoodmustmeetallbuilding |
|||
|
coderegulationsandistheresponsibilityof |
|||||
•Lightswitch.+ |
•Lightswitch.+ |
|
||||
|
thecontractor.Foroptimalperformance,the |
|||||
|
|
|
|
|
||
|
|
|
|
|
hoodshouldoverhandthecookingsurface |
|
*Itemsoldseparately |
|
|
|
andbeinstalledataheightbetween30-36 |
||
+Partsuppliedbyelectricalcontractor |
|
|
|
inchesabovethecookingsurface.Clearance |
||
|
|
|
|
|
inthehoodisneededforopeningthefront |
|
|
|
|
|
|
||
|
BEFOREINSTALLINGPLEASENOTE: |
|
filterhousingdoortoremovethefilterfor |
|||
|
|
|
|
|
cleaning(SeeFigure1B). |
|
1. Theuseof10"roundductorequivalentrectangularductis |
grease, and smoke. Thermador recommends installing the |
|
|
|||
|
acceptable for zero clearance. A Thermador VCHTR10 |
hood 30" to 36" above the countertop. The minimum hood |
|
|
||
|
transitions from the rectangular hood opening to a 10" |
installation height is 30". This is the distance from the |
|
|
||
|
diameter duct. Verify the installation will have enough |
cooktop to the bottom of the hood not the filter housing. |
|
|
||
|
clearance for the transition and ducting. |
|
|
|
|
|
|
|
6. The VTR600R, VTR1400Q and VTR1000Q remote blowers |
FIGURE 1A |
|||
2 A VCH54 with dual filters requires additional clearance |
require five wire installations. See Installation Instructions |
|||||
|
|
|||||
|
abovethehoodforthePLENUMtransition.Thistransitionis |
and Wiring Diagram supplied with these units. |
|
|
||
|
|
|
||||
|
showninFigure4(backpage)transitioningfromtheVCH54 |
|
|
|
MOUNTING HOLE LOCATIONS |
|
|
to the VCHTR10. |
7. Electrical power to the hood is for lights only. The light |
|
|
||
3. |
For the most efficient ducting layout, use a straight run or |
control is supplied by the electrical contractor. The light |
|
FIGURE2 |
||
switch must be a UL listed general switch. Use 75 Watt |
|
VCH36MountingPlate |
||||
|
as few elbows as possible. |
(maximum) reflector type light bulbs for 120 volts, 60 Hz. |
|
|||
|
|
(nottoscale)TopView |
||||
|
|
The VCH36 has one built-in filter box and two lights. The |
|
|||
|
|
|
|
|||
4. |
COLD WEATHER installations should have a backdraft |
VCH54 has two built-in filter boxes and three lights. For |
|
Requiredclearancein |
||
|
damperinstalledtominimizebackwardflowofcoldair,and |
electrical connections see Page 4, Item 5. |
|
|||
|
|
cabinetorsoffitfor |
||||
|
a nonmetallic thermal break to minimize heat loss due to |
|
|
|
||
|
|
|
|
transition.Overallheight |
||
|
conduction.Thedampershouldbeonthecoldairsideofthe |
8. DO NOT USE over solid fuel fired barbecue units. |
|
|||
|
|
of VCHTR10 is 12". |
||||
|
thermal break. The break should be as close as possible to |
|
|
|
||
|
|
|
|
VCHTR10 is noted by |
||
|
thelocationwheretheductingenterstheheatedportionof |
9. If the filter housing is installed in a custom hood made from |
|
|||
|
thehouse. |
combustiblematerialmakesurethatclearancestocombus- |
|
dashedlines. |
||
|
|
tible materials specified in the cooktop installation instruc- |
|
|
||
5. Hood installation height above the cooktop is the user's |
tions are satisfied. |
|
|
|||
|
preference. The lower the filter housings are above the |
|
|
|
|
|
|
cooktop, the more efficient the capture of cooking odors, |
|
|
|
|
|
|
|
|
|
|
|
Page 2 |
Page 3 |