Thermador UCVM36XS, UCVP36XS, UCVM30XS Installation Manual

4.3 (3)
Thermador UCVM36XS, UCVP36XS, UCVM30XS Installation Manual

Installation

 

G U I D E

UCVM30XS, UCVM36XS, UCVP36XS

 

Masterpiece® Series Downdraft Hood

 

T H E R M A D O R . C O M

Table of

C O N T E N T S

ABOUT THIS MANUAL ....................................................................

3

Be sure to observe all listed warnings and cautions.......................

3

IMPORTANT SAFETY INSTRUCTIONS ........................................

4-7

General notes....................................................................................

4

Proper installation and maintenance ................................................

5

Fire safety..........................................................................................

6

Child safety .......................................................................................

7

State of California Proposition 65 Warnings.....................................

7

Protecting the environment ..............................................................

7

BEFORE YOU BEGIN ......................................................................

8

Installation review .............................................................................

8

Tools needed ...................................................................................

8

Parts supplied ...................................................................................

8

PLAN THE INSTALLATION .............................................................

9

Select ducting option........................................................................

9

Ductwork preparation .......................................................................

9

Plan cabinetry ...................................................................................

9

DUCT EQUIVALENT CHART..........................................................

10

SYSTEM DIMENSIONS ..................................................................

11

ACCESSORIES................................................................................

12

INSTALLATION .........................................................................

13-21

Take measurements .......................................................................

13

Cut coutertop opening ..................................................................

13

Installation with electric and induction cooktops ...........................

13

Installation with gas cooktops.........................................................

14

Prepare downdraft housing ............................................................

14

Optional: Electrical panel can be mounted in a remote location .. 15

A - Installation using lexible blower attached

 

to downdraft ..................................................................................

15

B - Installation using lexible or remote blower -

 

mounted in a remote location - ducting through

 

front panel opening .......................................................................

16

C - Installation using inline or remote blower - ducting

 

through left, right, below or rear ...................................................

16

Insert upper support bracket and attach support leg ...................

16

Cut out ductwork opening in cabinet ............................................

17

Mounting downdraft with recirculation kit (UCVRECIRC) ..............

17

Mount downdraft in cabinet .....................................................

17-18

Gas cooktops only: Install gas cooktop seal kit

 

(UCV30ST, UCV36ST) ................................................................

18-19

Install roof cap, wall cap, inline or remote blower .........................

19

Connect ductwork ..........................................................................

19

Install the electrical panel ..............................................................

19

Plan house wiring ...........................................................................

19

Install electrical wiring ....................................................................

20

Connect downdraft to power ........................................................

21

Make-up air damper wiring ...........................................................

21

Install cooking appliance ...............................................................

21

Attach endcaps to downdraft ........................................................

21

THERMADOR® SUPPORT..............................................................

22

Before calling service ......................................................................

22

Data label........................................................................................

22

Service.............................................................................................

22

Parts and accessories......................................................................

22

This THERMADOR Appliance is made by

BSH Home Appliances Corporation 1901 Main Street, Suite 600 Irvine, CA 92614

Questions?

1-800-735-4328 www.thermador.com

We look forward to hearing from you!

Page 2

A B O U T T H I S M A N U A L

Be sure to observe all listed warnings and cautions.

Look for the triangles with exclamation marks inside.

WARNING

This indicates that death or serious injuries may occur as a result of non-observance of this warning.

CAUTION

This indicates that minor or moderate injuries may occur as a result of non-observance of this warning.

NOTICE: This indicates that damage to the appliance or property may occur as a result of non-compliance with this advisory.

Note: This alerts you to important information and/or tips.

Pay special attention to the important safety instructions in the “Safety” section.

Page 3

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

READ AND SAVE THESE INSTRUCTIONS

General notes

Note: Examine the appliance after unpacking it. In the event of transport damage, do not plug it in.

Note: Do not remove any of the aluminum tape as it is needed for sealing air leaks.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.

When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

Installation work and electrical wiring must be done by qualiied person(s) in accordance with all applicable codes and standards, including ire-rated construction.

Suficient air is needed for proper combustion and exhausting of gases through the lue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Ducted fans must always be vented to the outdoors.

INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE AFTER INSTALLATION IS COMPLETE.

IMPORTANT: SAVE FOR THE LOCAL INSPECTOR’S USE.

WARNING

When properly cared for, your new appliance has been designed to be safe and reliable. Read all instructions carefully before use. These

precautions will reduce the risk of burns, electric shock, ire, and injury to persons. When using kitchen appliances, basic safety precautions must be followed, including those in the following pages.

Page 4

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

READ AND SAVE THESE INSTRUCTIONS

Proper installation and maintenance

WARNING

Remove all tape and packaging before using the appliance. Destroy the packaging after unpacking the appliance. Never allow children to play with packaging material.

INSTALLER: Show the owner the location of the circuit breaker or fuse. Mark it for easy reference.

This appliance must be properly installed and grounded by a qualiied technician. Connect only to properly grounded outlet. Refer to Installation Instructions for details.

This appliance is intended for normal family household use only. It is not approved for outdoor use. See the Statement of Limited Product Warranty in the Use and Care Guide. If you have any questions, contact the manufacturer.

Do not store or use corrosive chemicals, vapors, lammables or nonfood products in or near this appliance. It is speciically designed for use when heating or cooking food. The use of corrosive chemicals in heating or cleaning will damage the appliance and could result in injury.

Do not operate this appliance if it is not working properly, or if it has been damaged. Contact an authorized servicer.

Do not repair or replace any part of the appliance unless speciically recommended in this manual. Refer all servicing to a factory authorized service center.

WARNING

Make sure the appliance and lights are cool and power to the appliance has been turned off before replacing the LED (if equipped). Failure to do so could result in electrical shock or burns.

WARNING

Do not use this unit in conjunction with a recirculation unit in gas cooking application.

CAUTION

Grease left on ilters can melt and move into the vent.

WARNING

Hidden surfaces may have sharp edges. Use caution when reaching behind or under appliance.

WARNING

Tie long hair so that it does not hang loose, and do not wear loose itting clothing or hanging garments, such as ties, scarves, jewelry, or dangling sleeves.

WARNING

Unit is heavy and requires at least two people or proper equipment to move and install.

WARNING

When the hood is operated in exhaust-air mode simultaneously with a different appliance which also makes use of the same chimney (such as gas, oil or coal-ired heaters, continuous-low heaters, hot-water boilers) care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the appliance for combustion. This can be achieved if combustion air can low through non-lockable

openings, e.g. in doors, windows and via the air-intake/exhaust-air wall box or by other technical measures, such as reciprocal interlocking, etc.

WARNING

Avoid carbon monoxide poisoning – Provide adequate air intake so combustion gases are not drawn back into the room.

An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.

Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as cooktops and ovens.

WARNING

To avoid electrical shock hazard, before installing, switch power off at the service panel and lock the panel to prevent the power from being switched on accidentally.

Page 5

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

READ AND SAVE THESE INSTRUCTIONS

Fire safety

WARNING

Use this appliance only for its intended use as described in this manual.

Always have a working smoke detector near the kitchen. In the event that personal clothing or hair catches ire, drop and roll immediately to extinguish lames.

Have an appropriate ire extinguisher available, nearby, highly visible and easily accessible near the appliance.

Smother lames from food ires other than grease ires with baking soda. Never use water on cooking ires.

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:a

a.SMOTHER FLAMES with a close-itting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the lames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

b.NEVER PICK UP A FLAMING PAN – You may be burned.

c.DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.

d.Use an extinguisher ONLY if:

-You know you have a Class ABC extinguisher, and you already know how to operate it.

-The ire is small and contained in the area where it started.

-The ire department is being called.

-You can ight the ire with your back to an exit.

aBased on “Kitchen Fire Safety Tips” published by NFPPA.

Whenever possible, do not operate the ventilation system during a cooktop ire. However, do not reach through ire to turn it off.

WARNING

RISK OF FIRE

When gas burners are in operation without any cookware placed on them, they can build up a lot of heat. A ventilation appliance installed above the cooker may become damaged or catch ire. Only operate the gas burners with cookware on them.

WARNING

RISK OF FIRE

Hot oil and fat catch ire fast. Never leave hot oil and fat unsupervised. Never extinguish a ire with water. Switch off the cooking position. Suffocate lames carefully with a lid, a ire blanket or similar.

WARNING

RISK OF FIRE

Grease deposits in the grease ilters can ignite.

Clean the grease ilters at least every two months or as frequently as necessary.

Never operate the appliance without the grease ilters.

WARNING

RISK OF FIRE

Grease deposits in the grease ilters can catch ire. Never work with a naked lame near the appliance (e.g. lambéing). Install the unit near a heat-producing appliance for solid fuels (e.g. wood or coal) only if there is a closed, non-detachable cover. There must be no lying sparks.

WARNING

RISK OF FIRE

Use only metal ductwork.

WARNING

RISK OF BURNS

The accessible parts get hot during operation. Never touch hot parts. Keep children away.

CAUTION

It is recommended to wear gloves and long sleeves to protect hands and forearms from abrasion and potential scratches during the installation process.

Page 6

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

READ AND SAVE THESE INSTRUCTIONS

Child safety

When children become old enough to use the appliance, it is the responsibility of the parents or legal guardians to ensure that they are instructed in safe practices by qualiied persons.

Do not allow anyone to climb, stand, lean, sit, or hang on any part of an appliance. This can damage the appliance or cause injury.

WARNING

Be sure the entire appliance (including the grease ilters and light bulbs, if applicable) has cooled and grease has solidiied before attempting to clean any part of the appliance.

Do not use steam cleaners to clean the appliance.

State of California Proposition 65 Warnings

WARNING

This product may contain a chemical known to the State of California, which can cause cancer or reproductive harm. Therefore, the packaging of your product may bear the following label as required by California:

STATE OF CALIFORNIA PROPOSITION 65 WARNING:

WARNING

Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Protecting the environment

Unpack the appliance and dispose of the packaging in line with environmental requirements.

NOTICE

Risk of damage due to corrosion. Always turn appliance on when cooking to avoid condensation buildup. Condensation can lead to corrosion damage.

Risk of damage due to moisture entering into the electronic circuitry. Never clean operator controls with a wet cloth.

Surface damage due to incorrect cleaning. Clean stainless steel surfaces in the grain direction only. Do not use any stainless steel cleaners on operator controls. Never use strong or abrasive cleaning agents, since they can cause surface damage.

Risk of damage from condensation back low. Install exhaust vent at a slight downward slope away from the appliance (1° slope).

Page 7

B E F O R E Y O U B E G I N

Installation review

This downdraft system can be used to exhaust cooking by-products such as heat, steam, and smoke that may be created while cooking using gas or electric cooktops. With its versatile design, there are six (6) basic discharge options - left, right, rear, below, front and recirculation. It is important to irst plan your installation. The purchase of additional accessories to complete the installation may be necessary.

It can be mounted in an island, peninsula, or conventional wall location. The blower (purchase separately) and electrical panel can be mounted to the downdraft unit, inside the cabinet, or in a convenient remote location.

This unit can be easily installed following these basic steps:

Plan the installation.

Cut out the countertop opening.

Prepare the downdraft housing.

Cut out the cabinet opening for discharge.

Mount the downdraft in the cabinet.

Install gas cooktop seal kit accessory, if applicable.

Connect the ductwork and install the blower.

Install downdraft electrical panel, if in remote location.

Install the cooking appliance.

Install end caps to downdraft.

Check the operation.

Note: the high level of air low of this appliance may effect the gas lame on some types of gas cooktops. This is NORMAL and will cause no harm, but can be corrected by lowering the speed of the blower.

Tools needed

Measuring tape

Pencil

Phillips screwdriver no. 2

Nut drivers - 11/32” (8.7 mm), 3/8” (9.5 mm), 7/16” (11.1 mm)

Box-end wrench

Spirit-level

Aluminum tape (DO NOT use insulating tape)

Saw

Tin snips

Work gloves

Parts supplied

 

1 Parts Bag containing:

 

2 - Screws,

2 - Screws,

 

 

No. 8-18 x .375

 

 

1/4-20 x .50

 

 

(9.5 mm)

 

 

(12.7 mm)

 

 

Phillips

 

 

Hex Head

 

 

 

8 - Wood Screws,

 

 

 

 

No. 10 x .50 (12.7 mm)

 

 

Phillips Round Head

 

1 - Plastic installation

 

 

2 - End Cap Trim

template

 

 

(see page 13)

2 - Support legs

 

 

 

2 - Upper Support

1 - Electrical Panel

Brackets

 

 

 

 

DE

 

 

 

UI N

O

 

 

G

 

 

E TIO

 

 

 

N DAD

 

INST

CARTILISA

 

 

YCUI

 

 

 

ANDD'URETIE

 

 

 

USO

 

 

 

USE D'ENT

 

 

 

GUIDED

 

 

 

ET

 

 

 

GUÍA

 

1 - Special key

Installation

Use and Care guide

instructions

 

 

 

Wiring diagram

Downdraft Ventilator Housing

Page 8

P L A N T H E I N S TA L L AT I O N

Select ducting option

A

 

B

D

 

E

 

 

C

 

F

G

 

 

HD1101

 

 

The 6 basic discharge connections, left, right, rear, front, below and recirculation can be achieved through A to G with the optional parts listed.

1.The downdraft blower system is designed for use with 8” (203 mm) round ductwork using a lexible blower or 6” (152 mm) or 10” (254 mm) round ductwork using an inline or remote blower. (Purchase blowers separately.) Seven (7) different discharge connections are available:

A = 8” (203 mm) Round, Left Discharge out of Flex Blower B = 8” (203 mm) Round, Right Discharge out of Flex Blower

C = 8” (203 mm) Round, Down Discharge out of Flex Blower (Electrical Panel to be mounted remotely)

D = 1-7/8” x 19” (48 mm x 483 mm), Left Discharge out of Housing to Remote Blower or Flex Blower in remote location.

Use 1-7/8” x 19” (48mm x 483mm) to 6”, 8”, or 10” (152 mm, 203 mm, or 254 mm) round transition or 1-7/8“ x 19“ (48 mm x 483 mm) ductwork as appropriate.

E = 1-7/8” x 19” (48 mm x 483 mm), Right Discharge out of Housing to Remote Blower or Flex Blower in remote location.

Use 1-7/8” x 19” (48 mm x 483 mm) to 6”, 8”, or 10” (152 mm, 203 mm, or 254 mm) round transition or 1-7/8“ x 19“ (48 mm x 483 mm) ductwork as appropriate.

F = 1-7/8” x 19” (48 mm x 483 mm), Rear Discharge out of Housing to Remote Blower or Flex Blower in remote location.

Use 1-7/8” x 19” (48 mm x 483 mm) to 6”, 8”, or 10” (152 mm, 203 mm, or 254 mm) round transition or 1-7/8“ x 19“ (48 mm x 483 mm) ductwork as appropriate.

G = 1-7/8” x 19” (48 mm x 483 mm), Down Discharge out of Housing to Remote Blower or Flex Blower in remote location.

Use 1-7/8” x 19” (48 mm x 483 mm) to 6”, 8”, or 10” (152 mm, 203 mm, or 254 mm) round transition or 1-7/8” x 19” (48 mm x 483 mm) ductwork as appropriate.

2.For best performance: Choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions. Check location of loor joists, wall studs, electrical wiring or plumbing for possible interference.

Note: The manufacturer is not responsible for performance complaints attributable to the duct section.

The device achieves its optimum performance by means of a short, straight exhaust air duct and as large a pipe diameter as possible.

The optimum extraction performance is not achieved and fan noise is increased if exhaust air ducts are long and rough and if there is a large number of duct bends or diameters less than 6” (152 mm).

The pipes or hoses for laying the exhaust air line must consist of non-combustible material.

Seal the connection points of the ducts appropriately.

Ductwork must vent outside, not into attic spaces for example, unless the available ’Non-duct Recirculation Kit’ is used.

Ductwork preparation

DUCTING RECOMMENDATIONS

Proper performance is dependent upon proper ducting.

MAKE-UP AIR: Local building codes may require the use of make-up air systems when using ducted ventilation systems greater than speciied CFM of air movement. The speciied CFM varies from locale to locale. It is the responsibility of the owner and the installer to determine if additional requirements and/or standards apply to speciic installations.

DO NOT USE FLEXIBLE DUCT; it creates back pressure/ air turbulence and reduces performance.

Always install a metal vent cover where the ductwork exits the house.

COLD WEATHER installations should have an additional backdraft damper installed to minimize backward cold air low and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork.

The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the ducting enters the heated portion of the house.

For safety reasons, ducting should vent directly outdoors (not into an attic, underneath the house, into the garage or into any enclosed space). In gas cooking applications, the unit cannot be used in conjunction with a recirculation unit.

THERMADOR® recommends not exceeding 50 ft. (15 m) of equivalent duct.

Plan cabinetry

For left, right, or rear exhaust:

Allow at least 18” (457 mm) for transition and elbow or blower.

For left / right exhaust:

A 30” (762 mm) deep cabinet is recommended to align properly with lex blower. Flex blower can be mounted to rear cabinet wall or to a platform / frame (not provided) on the base of the cabinet loor. (See lex blower instructions.)

Cabinet depths of 24” (610 mm) to 30” (762 mm) are required - depending on the type of cooking appliance.

For some applications, gas or electrical connections will need to be moved or routed around downdraft unit.

For gas cooktop installations make sure that a minimum 27 square inch (174 cm²) opening is provided in the toe-kick and cabinet base. Inadequate ventilation of the cabinet below the cooktop may result in lame outage when operating the fan on higher speeds.

Note: A cooktop sealing kit must be purchased for gas applications. The kit includes hole covers for the toe-kick and cabinet base, as well as a trim seal for the cooktop.

Page 9

D U C T E Q U I VA L E N T C H A R T

Duct Piece

Size

Equivalent

 

 

Size

Equivalent

Length

 

Duct Piece

Length

(in./mm)

 

(in./mm)

 

(ft/m)

 

(ft/m)

 

 

 

 

 

 

6 (152)

1.2 (0.37)

 

3¼" x 10" (83 mm x 254 mm)

 

 

Smooth, straight

8 (203)

0.7 (0.21)

 

6 (152)

10 (3)

 

to round 90° Elbow

 

10 (254)

0.6 (0.18)

 

 

 

 

 

 

 

 

3¼" x 10" (83 mm x 254 mm)

N/A

15 (4.6)

 

 

 

 

Center reverse elbow , left

3¼" x 10"

 

 

 

 

 

N/A

1 (0.3)

 

 

 

 

(83 mm x 254 mm)

 

 

 

 

straight

 

 

 

3¼" x 10" (83 mm x 254 mm),

N/A

25 (7.6)

 

 

 

 

3¼" x 14"

 

 

 

Center reverse elbow , right

 

 

 

 

 

(83 mm x 356 mm)

N/A

0.7 (0.21)

 

 

 

 

straight

 

 

 

3¼" x 10" (83 mm x 254 mm),

 

 

 

6 (152)

12 (3.7)

 

N/A

15 (4.6)

 

 

Left reverse elbow

 

 

 

 

90° Elbow , round

8 (203)

6 (1.8)

 

 

 

 

 

10 (254)

5 (1.5)

 

3¼" x 10" (83 mm x 254 mm),

 

 

 

6 (152)

5 (1.5)

 

N/A

25 (7.6)

 

 

Right reverse elbow

45° Elbow , round

8 (203)

3 (0.9)

 

 

 

 

 

 

 

 

10 (254)

2 (0.6)

 

 

6 (152)

2 (0.6)

3¼" x 10"

 

 

 

 

N/A

5 (1.5)

 

Round wall cap

 

2 (0.6)

(83 mm x 254 mm),

 

8 (203)

90° Elbow , round

 

 

 

 

10 (254)

2 (0.6)

3¼" x 10"

 

 

 

 

 

 

 

 

6 (152)

2 (0.6)

(83 mm x 254 mm),

N/A

15 (4.6)

 

 

45° Elbow , round

 

Round roof cap

8 (203)

2 (0.6)

 

 

 

 

 

 

 

 

3¼" x 10"

 

 

 

 

10 (254)

2 (0.6)

 

 

 

 

 

 

(83 mm x 254 mm),

N/A

20 (6.1)

 

2" (51 mm) long, 3¼" x 10"

N/A

20 (6.1)

Flat elbow

 

 

 

(83 mm x 254 mm) flex

 

 

 

 

 

 

3¼" x 10"

6 (152)

5 (1.5)

 

3¼" x 10" (83 mm x 254 mm),

 

 

(83 mm x 254 mm)

8 (203)

2 (0.6)

 

N/A

2 (0.6)

to round

 

Roof jack and shutter

 

 

 

Round to 3¼" x 10"

 

 

 

 

 

 

 

 

 

NOTE: These commonly used installation parts can be purchased at

(83 mm x 254 mm)

6 (152)

10 (3)

 

90° Elbow

 

 

 

a local hardware store. THERMADOR® does not manufacture

 

 

 

 

these parts.

 

 

 

 

 

 

 

 

Measurements in inches (mm).

Page 10

S Y S T E M D I M E N S I O N S

7.500 in

191 mm

5.000 in 127 mm

CVTSIDE6

1-7/8” x 19” (48 mm x 483 mm) TO 6” (152 mm) RD. TRANSITION

 

 

7.500 in

 

 

191 mm

 

 

5.750 in

 

 

146 mm

 

SIDE

CVTSIDE10

 

DUCTING

 

1-7/8” x 19” (48 mm x 483 mm)

 

30.000 in

TO 10” (254 mm) RD.

 

TRANSITION

 

762 mm

VTD600P

36.000 in

 

FLEX BLOWER

914 mm

 

 

 

 

12.750 in

 

 

 

 

 

7.500 in

 

 

 

 

 

324 mm

 

 

24.000 in

 

 

191 mm

 

VTD600P

 

 

 

11.560 in

 

 

 

 

6.000 in

 

 

 

 

 

 

610 mm

 

 

152 mm

 

FLEX BLOWER

 

 

294 mm

 

 

 

 

 

 

 

12.750 in

 

 

 

 

 

 

 

 

 

 

 

324 mm

FRONT

FRONT

 

 

 

 

 

 

SIDE

 

 

11.586 in

 

 

 

 

12.750 in

 

11.586 in

 

 

 

 

 

 

 

C

 

 

 

19.000 in

324 mm

 

 

294 mm

 

 

 

 

 

INLET

294 mm

 

OUTLET

L

 

 

 

483 mm

5.000 in

 

 

 

 

 

 

 

 

 

 

 

OUTLET

 

 

 

 

 

 

 

 

 

127 mm

 

 

 

 

4.240 in

 

 

 

 

 

 

 

5.272 in

 

 

 

108 mm 7.320 in

 

 

 

 

 

CVTSIDE8

 

 

 

 

 

 

 

 

 

 

134 mm

 

 

 

186 mm

 

 

 

 

 

1-7/8” x 19”

 

10.310 in

 

 

 

 

 

 

CVDUCT2 1-7/8” x 19”

 

262 mm

 

 

 

 

 

 

(48 mm x 483 mm)

 

 

 

 

 

 

27.152 in

(48 mm x 483 mm)

 

 

 

 

 

 

TO 8” (203 mm) RD.

15.952 in

 

 

 

690 mm

 

RECTANGULAR DUCT

 

 

C

33.152 in

TRANSITION

 

405 mm

 

 

 

 

 

 

14.048 in 357 mm

 

 

L

842 mm

 

 

 

 

 

7.976 in

 

 

 

 

 

 

 

 

 

 

203 mm

 

 

 

 

 

 

 

 

 

 

 

 

3.750 in

 

 

UCVM30XS

 

 

 

FRONT

 

 

95 mm

 

 

 

 

 

 

16.000 in

 

 

 

 

 

 

 

 

 

 

 

 

OUTLET

UCVM36XS

 

 

UCVRECIRC NON-DUCT

 

406 mm

 

 

 

 

UCVP36XS

 

 

 

 

 

 

 

 

DOWNDRAFT

 

 

 

RECIRCULATION KIT

 

17.478 in

 

 

 

 

 

 

 

 

 

 

 

6.478 in 444 mm

11.000 in

 

 

CVTFRONT6

 

 

 

 

 

 

 

165 mm

279 mm

 

 

 

 

 

 

 

 

 

 

 

 

6” (152 mm) RD. DUCT PLATE

 

 

 

 

 

SIDE

 

 

 

 

 

CVTFRONT8

 

 

CVTRECT2

 

 

 

 

 

 

 

 

 

 

CVTSIDE10

 

 

 

 

 

8” (203 mm) RD. DUCT PLATE

 

 

1-7/8” x 19” (48 mm x 483 mm)

 

 

 

 

 

 

CVTFRONT10

 

 

RECTANGULAR DUCT

 

1-7/8” x 19”

 

 

 

 

 

10” (254 mm) RD. DUCT PLATE

 

 

ADAPTER

(48 mm x 483 mm)

 

 

 

 

 

 

 

 

 

TO 10” (254 mm) RD.

 

 

 

 

 

 

 

FRONT

REAR

 

TRANSITION

 

 

 

10” (254 mm) RD.

 

 

 

 

 

 

 

 

 

 

 

 

 

29.750 in

 

 

 

5.750 in

 

 

ELBOW

*

 

 

REAR

 

 

 

146 mm

 

 

 

 

 

756 mm

 

 

 

7.500 in

 

 

 

 

 

 

(Chimney DOWN)

 

 

 

191 mm

 

 

 

 

 

 

DUCTING

41.750 in

 

 

 

 

 

 

 

 

 

 

 

1060 mm

CVDUCT2 1-7/8” x 19”

 

 

 

 

 

 

 

 

(Chimney UP)

(48 mm x 483 mm)

1.875 in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECTANGULAR DUCT

48 mm

 

 

 

8” (203 mm) RD.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.410 in

24.000 in

 

 

6.000 in

 

 

ELBOW*

 

 

 

610 mm

 

 

152 mm

 

 

 

 

 

 

 

61 mm

 

 

7.500 in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

191 mm

 

 

 

 

 

 

 

 

 

CVTSIDE8 1-7/8” x 19” (48 mm x 483 mm)

 

 

 

 

 

 

 

 

TO 8” (203 mm) RD. TRANSITION

 

 

 

 

*Not available from Thermador. Purchase locally.

CVTSIDE6

1-7/8” x 19”(48 mm x 483 mm) TO 6” (152 mm) RD. TRANSITION

5.000 in

127 mm

7.500 in

191 mm

6” (152 mm) RD. ELBOW*

Page 11

A C C E S S O R I E S (purchase separately)

Flexible Blower

Inline and Remote Blowers

Thermador Model VTD600P

Thermador Models VTI610, VTR630, VTI1010, VTR1030, VTR1330

MODEL DESCRIPTION

Non-Duct Recirculating Kit

Used in applications where ducting is not

feasible or available. Mount to toe kick

or base of a cabinet and attach directly

to VTD600P Flexible Blower using 8”

(203 mm) round duct. Kit can be rotated

so that the exhaust is not directly at your feet. Includes decorative cover plate.

UCVRECIRC

UCVFILTER (replacement ilter)

 

Rough-in Plate - 8” (203 mm) Round

 

Use for applications where 8” (203 mm)

 

round duct or elbow attaches to front

 

of airbox (VTD600P inline blower

 

installation).

CVTFRONT8

 

 

Rough-in Plate - 6” or 10” (152 mm or

 

254 mm) Round

 

Use for applications where 6” or 10”

 

(152 mm or 254 mm) round duct or

 

elbow attaches to front of airbox (inline

 

or remote blower installation).

CVTFRONT6

 

CVTFRONT10

 

 

Extension Cable - 5-ft. (1.5 m)

 

Used in applications where the electrical

 

panel is remotely mounted. If blower

 

discharge is down, electrical panel

 

must be relocated. Extends electrical

 

panel cable an additional 5-feet (1.5 m)-

EXTNCE5

with the ability to connect up to two

extension cables.

 

 

Gas Cooktop Seal Kit - 30-in. (762 mm),

 

36-in. (914 mm)

 

Used to provide seal between gas

 

cooktop and downdraft. Also includes

 

cabinet hole cover plates. Two grilles are

 

provided in the kit, you may only need

UCV30ST

one for your speciic installation.

 

UCV36ST

 

 

Rectangular Duct - 2-ft. (0.6 m) sections

 

(1-7/8” x 19” /48 mm x 483 mm)

 

Galvanized steel construction.

 

2-ft. (0.6 m) sections can be connected

 

together.

CVDUCT2

 

 

Rectangular Adapter for 1-7/8” x 19”

 

(48 mm x 483 mm)

 

Use to connect 1-7/8” x 19” (48 mm x

 

483 mm) rectangular duct directly to

 

downdraft when using side, below or

CVTRECT2

rear exhaust.

MODEL

CVTSIDE8

CVTSIDE6

CVTSID10

2

1

B Connects to Hood C Connects to Remote or In-line Blower

EXTNCB25W

EXTNSET4

DESCRIPTION

1-7/8” X 19” (48 mm x 483 mm) to 8” (203 mm) Round Transition

Rectangular to 8” (203 mm) round transition for left, right, below, or rear exhaust - using Model VTD600P Flex Blower. Can be attached to downdraft unit or rectangular duct (CVDUCT2).

1-7/8” X 19” (48 mm x 483 mm) to 6” or 10” (152 mm or 254 mm) Round Transition

Rectangular to 6” or 10” (152 mm or 254 mm) round transition for left, right, below, or rear exhaust using inline or remote blower. Can be attached to downdraft unit or rectangular duct (CVDUCT2).

Extension Cable - 25-ft. (7.62 m)

The remote or inline blower harness should be routed through the knockout and secured with a 3/4” (19 mm) strain relief. The 25 ft. Extension Cable can then be connected to the Adapter Cable included in EXTNSET4 Accessory Kit and then to the hood electrical panel.

Extension Cable Connection Kit

Cable connection kit containing

(4) accessory cable adapters to connect a variety of blower and hood combinations.

Page 12

I N S TA L L AT I O N

Take measurements

1.Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements. However, it is recommended that oversized cabinets be used for easier installation. Custom island designs need to account for deeper cabinets, especially when mounting the blower behind the downdraft. You must also plan for an access door.

Pay special attention to the areas of potential interference highlighted below. A countertop with (A) a raised lip and/or (B) a backsplash may not allow enough lat countertop for a proper installation. Note that a minimum of 2-7/8” (73 mm) of lat countertop is required behind

cooktop (C) and that a minimum of 2-7/8” (73 mm) is necessary between the back edge of the cooktop and the inside of cabinet back (D).

 

FLAT COUNTERTOP (C)

 

A

2-7/8” (73 mm) MIN.

C

TEMPLATE

 

 

 

2-1/8” (54 mm) MIN.

 

 

COUNTERTOP

 

 

COOKTOP

B

 

 

DOWNDRAFT

2-7/8” (73 mm) MIN.

D

 

FRONT TO BACK INSIDE CABINET DEPTH

5/8” (16 mm) MIN.

Cut countertop opening

1.Lay out and cut the cooktop cut-out far enough FORWARD so downdraft will it behind it.

2.Set cooktop in place and slide it as far forward as possible without exposing any gaps. Center and square it with edges of countertop.

COOKTOP

Template against back edge of cooktop

3.Place the plastic template against the back lange of the cooktop. Center the template. Trace around template to mark the downdraft opening.

4.Remove cooktop from countertop.

5.Cut downdraft opening. Be careful not to chip edges of countertop.

Installation with electric and induction cooktops

Dimension “BT” is thickness of the backsplash. Provide 1/2” (13 mm) clearance between the vent cutout and the backsplash. Any backsplash with a curved

radius where it meets the counter will require additional clearance. Thicker backsplashes may be used by increasing the counter and cabinet depths.

Set the cooktop into the coutertop opening so that the back edge of the cooktop overlaps the leading edge of the downdraft.

Template 2-1/8” (54 mm)

Downdraft cutout width:

30” (762 mm) is 27-1/16” (687 mm) 36” (914 mm) is 33-1/16” (840 mm)

BT

MIN.

1/2” (13 mm)

2-1/4” (57 mm)

25-7/16” - 25-9/16”

(646 mm - 649 mm)

22-11/16” - 22-13/16”

(576 mm - 579 mm)

19-7/8” - 20”

(505 mm - 508 mm)

11/16” (17 mm)

Cooktop cutout width

Measurements in inches (mm).

Page 13

I N S TA L L AT I O N

Installation with gas cooktops

Dimension “BT” is thickness of the backsplash. Provide 1/2” (13 mm) clearance between the vent cutout and the backsplash. Any backsplash with a curved

radius where it meets the counter will require additional clearance. Thicker backsplashes may be used by increasing the counter and cabinet depths.

Set the cooktop into the coutertop opening so that the back edge of the cooktop overlaps the leading edge of the downdraft.

Downdraft cutout width:

30” (762 mm) is 27-1/16” (687 mm) 36” (914 mm) is 33-1/16” (840 mm)

BT

MIN.

1/2” (13 mm)

1-7/8” (48 mm)

Template

 

2-1/8” (54 mm)

24-11/16” (627 mm)

 

22-5/16” (567 mm)

 

19-1/8” (486 mm)

 

1-1/16”

 

(27 mm)

Cooktop cutout width

Measurements in inches (mm).

Prepare downdraft housing

1. Place the downdraft on its back on a table or lat work surface.

UPPER

SUPPORT

BRACKETS

DISCHARGE COVERS

SUPPORT

LEG

NUT

(KEEP)

SCREWS (DISCARD)

NUTS (KEEP)

2.Detach the upper support brackets from the downdraft by cutting off the tie wraps. Remove and set aside both support legs from sides of the downdraft (one leg per side).

Note: Discard the retaining screws, but KEEP THE NUTS.

Remove the bundle of 3 dischage covers from the bottom of the downdraft.

3.Cover the discharge openings that won’t be used for ducting. Note: Use the nuts previously removed for side discharge covers.

Page 14

I N S TA L L AT I O N

Optional: Electrical panel can be mounted in

A - Installation using flexible blower

a remote location.

attached to downdraft

No. 8-32

HEX NUTS

Example: There is a drawer at the bottom of the cabinet, in front of the downdraft. This may require the electrical panel to be mounted in an adjacent cabinet. If blower discharge is down, electrical panel must be relocated.

1.Remove (4) no. 8-32 hex nuts and electrical panel. 5-ft. (1.5 m) extension cables (purchase separately) may be needed to mount electrical panel in a remote location. Do not use more than 2 extension cables (EXTNCE5). Do not mount with electrical panel slots facing downward.

2.Installation of a remotely located electrical panel may be completed after connecting the ductwork and installing the blower. Install electrical panel according to local codes.

(Purchase Model VTD600P Flexible Blower separately.)

1.Remove hex nuts to remove front panel cover.

2.Determine whether lex blower will discharge to the left, right, or down.

3.If blower discharge is down, remove (4) no. 8-32 hex nuts and electrical panel.

4.Place blower over studs around front panel opening.

5.Tighten hex nuts to secure blower in place.

(4) BOLTS

BLOWER

SUPPORT LEGS

Based on blower and ducting option selected, go to the relevent section:

A - Installation using flexible blower attached to downdraft

B - Installation using flexible or remote blower - mounted in a remote location - ducting through front panel opening

C - Installation using inline or remote blower - mounted in a remote location - ducting through left, right, below or rear

6.Remove bolts from lex blower housing. Attach blower support legs to lex blower housing with these (4) bolts. Do not tighten bolts at this time.

Page 15

I N S TA L L AT I O N

B - Installation using flexible or remote blower - mounted in a remote location - ducting through front panel opening

CAUTION

If lexible blower is mounted as an inline blower: Do not use legs alone for support. It may be necessary to add extra support for the lexible blower.

1.Remove hex nuts to remove front panel cover.

2.If blower discharge is down, remove (4) no. 8-32 hex nuts and electrical panel.

3.Place 6”, 8”, or 10” (152 mm, 203 mm, or 254 mm) round rough-in plate (purchase separately) over studs around front panel opening.

4.Tighten hex nuts to secure remote discharge plate in place.

C - Installation using in-line or remote blower - with ducting through left, right, below or rear

(Requires purchase of 1-7/8” x 19” (48 mm x 483 mm) to 6”, 8”, or 10” (152mm,203mm,or254mm)roundtransition.1-7/8”x19”(48mmx483mm) rectangular duct and connection adapters are also available.)

DUCTING OUT RIGHT SIDE OF

HOUSING SHOWN.

1.Use nuts to connect 1-7/8” x 19” (48 mm x 483 mm) rectangular ductwork connection adapter or 1-7/8” x 19” (48 mm x 483 mm) to 6”, 8”, or 10” (152 mm, 203 mm, or 254 mm) round transition to housing when installing ductwork.

Insert upper support brackets and attach support legs

1.Slide upper suport brackets into slide channel at top left and right of unit.

2.Attach previously removed support legs to downdraft using one nut for each leg. Do not tighten nut completely at this time.

Page 16

I N S TA L L AT I O N

Cut out ductwork opening in cabinet

1.Measure and mark where to cut the ductwork opening in the cabinet based on the ducting option selected. Use the dimensions in the illustration below to help plan how and where to provide duct access through your cabinet.

REAR CORNER OF

 

COOKTOP CUT-OUT INSTALLATION

 

 

 

 

 

 

CENTER LINE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(149

mm)

HOLE FOR

 

 

 

 

 

 

 

 

 

 

 

 

 

17/8” x 19”

 

 

 

INSIDE

 

41/8” (48 mm x 483 mm)

 

 

 

 

(105 mm)

DUCT &

 

 

 

CABINET BACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRANSITIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

24¾” (629 mm)

 

 

 

 

 

 

 

21” (533 mm)

4”

(102 mm) 21” 4” (102 mm)

(533 mm) centered

 

 

 

 

 

 

 

 

A

 

INSIDE

1½”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(38 mm)

 

 

 

 

CABINET FLOOR

 

 

 

 

 

 

 

 

 

 

 

 

Hole in Cabinet Floor

Measurements in

 

 

 

 

 

 

Dimension A

 

inches (mm).

 

 

 

 

 

 

Using Flex Blower (Model

 

 

 

 

 

VTD600P & 8” (203 mm) round duct straight down through cabinet loor.)

(1½"/ 38 mm left of installation center line)

7¾ inches (197 mm)

3.Check that markings in cabinet line up with ducting coming from downdraft.

4.Remove downdraft housing from cabinet.

CAUTION

Before cutting hole in cabinet for ductwork, check for interference with loor joists, wall studs, electrical wiring or plumbing.

5. Cut ductwork hole in cabinet - as well as holes in wall or loor a necessary.

Mounting downdraft with recirculation kit (UCVRECIRC)

If unit is to be installed using a recirculation kit, please follow the installation instructions for the recirculation kit (UCVRECIRC) prior to installing and mounting the downdraft in the cabinet.

Mount downdraft in cabinet

1.Set downdraft into cabinet/countertop opening as far back as possible and make sure it is level.

2 No. 10 x 0.500

WOOD SCREW

2. Set downdraft into cabinet/countertop opening as far back as possible

and make sure it is level.

2. Extend support legs and attach to bottom of cabinet with (2) screws through each leg. Tighten nuts.

If cabinet bottom is removed: Use blocks as spacers between loor and support legs.

Page 17

I N S TA L L AT I O N

Gas cooktops only:

Install gas cooktop seal kit (UCV30ST,

UCV36ST) (purchase separately)

Available for application with gas cooktops - where proper sealing is required and holes are required in cabinet base. Kit includes trim seal, toe-kick cover grille, and cabinet hole cover grille.

2 No. 10 x 0.500

 

WOOD SCREW

 

B

B

 

3. Extend upper support brackets and attach to sides of cabinet with (2)

 

screws through each bracket.

C

Installations using lexible blower only:

(4)

FLEXIBLE

BOLTS

BLOWER

 

4.Extend blower support legs and secure them to bottom of cabinet with a screw through each leg. Tighten (4) bolts to secure support legs to lex blower.

C

B

A

B A B

BCut one 18¼” x 2½” (464 mm x 64 mm) OPENING (A)* in the cabinet toe kick.

-- or --

Cut one 18¼” x 2½” (464 mm x 64 mm) OPENING (B) in the cabinet side or back.

Mount one of the two metal grilles over this opening, using two screws provided.

CIf you chose to cut an opening in the toe kick - you must cut another 18¼” x 2½” (464 mm x 64 mm) OPENING (C)* in the cabinet loor.

Mount the second metal grille over this opening.

* IMPORTANT NOTE

When using toe kick opening (A) with opening (C) in cabinet loor: Air must be able to low freely between these two openings - and not restricted by cabinet structure or any other obstruction.

Page 18

I N S TA L L AT I O N

E

B E G D

A C

D F

DClean housing surface (B) with Isopropyl Alcohol or Rubbing Alcohol. Remove TAPE STRIPS to reveal adhesive side of tape from the back side of TRIM BRACKET (A).

ECenter trim bracket left-to-right at TOP OF DOWNDRAFT HOUSING (B). Stick trim bracket to downdraft housing so that FLANGES (C) and (D) are lush with each other.

FCut TRIM SEAL (E) to length: No shorter than downdraft countertop cutout opening and no longer than cooktop width.

GRemove tape backing from TRIM SEAL (E). Center trim seal left-to-right and stick trim seal across both FLANGES (C) and (D).

Install roof cap, wall cap, inline or remote blower

1. Follow instructions included with caps, inline and remote blower.

Connect ductwork

1.From roof cap, wall cap, or remote blower - work back towards the cabinet, attaching all ductwork, elbows and transitions as previously planned.

2.Connect ductwork (and transition, if required) to lex blower or downdraft. If necessary, use (2) no. 8-18 x .375 (9.5 mm) Phillips screws for transition.

Note: Regardless of blower placement/exhaust, ensure that all seams are properly taped - to make them secure and air-tight. This includes seams/ gaps between panels and/or on the blower.

Install the electrical panel

(if previously removed from downdraft housing)

1.If electrical panel was removed from the downdraft housing in order to mount it in a remote location: Mount electrical panel in chosen location.

Note: Do not mount electrical panel with slots in cover facing downward.

Plan house wiring

WARNING

RISK OF ELECTRIC SHOCK

Parts inside the appliance can have sharp edges. The connection cable can be damaged. Do not bend or pinch connection cables during installation.

Before connecting the appliance, check the house wiring to make sure it has suficient circuit protection. The voltage and frequency of the appliance must match the electrical installation (see rating plate).

Only a qualiied electrician who takes the appropriate regulations into account may lay or replace the connecting cable.

Follow all valid standards and laws.

Ensure that the electrical connection meets the requirements of the latest version of all applicable standards and laws in the appropriate country, especially the following standards:

National Electrical Code, ANSI/ NFPA 70, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91, UL 507.

Have a qualiied electrical technician check the grounding of the appliance.

Do not ground to a gas line.

Keep these installation instructions for future reference.

Ensure that the wire diameter meets the requirements of the latest version of all applicable standards and laws in the appropriate country, especially the following standards:

National Electrical Code, ANSI/NFPA 70, or CSA Standards C22.1- 94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91.

The downdraft with the Flex Blower (purchase separately) draws 3.0 Amps and requires a 120 VAC, 60 Hz circuit.

The downdraft with Remote Blower (purchase separately) draws 9.0 Amps (max.) and requires a 120 VAC, 60 Hz circuit.

The downdraft has a 30-in. (762 mm). long power cord with a 3-pronged plug. Plan to provide a grounded outlet in a location which will allow the power cord to reach.

Page 19

I N S TA L L AT I O N

Install electrical wiring

CAUTION: Installation work and electrical wiring must be done by qualiied person(s) in accordance with all applicable codes, regulations, and standards, including ire-rated construction.

CAUTION: Do not use an extension cord. If the product power cord is too short, have a qualiied electrician install a three slot receptacle.

From exterior or in-line blower

1.Install a standard wiring box, with 3-pronged receptacle, within reach of the downdraft’s power cord.

2.Remove electrical panel wiring box cover. Secure blower power cable to electrical panel wiring box with U.L. approved strain relief.

Based on blower selected, go to the relevent section:

A - Flex blower wiring B - Remote blower wiring

A - Flex blower wiring

CAUTION: Installation work and electrical wiring must be done by qualiied person(s) in accordance with all applicable codes and standards, including ire-rated construction.

 

 

 

 

 

ELECTRICAL PANEL

 

GREEN

 

 

 

 

 

 

 

GROUND SCREW

 

 

WHITE

 

 

 

 

 

 

WHITE (NEUTRAL)

 

 

BLUE (CAP OFF)

 

 

BLUE (CAP OFF)

 

M

RED

 

 

 

GRAY (MED 2)

 

 

 

 

 

 

ORANGE

 

 

ORANGE (MED-HIGH 3)

 

 

BLACK

 

 

BLACK (HIGH 4)

 

 

 

 

 

 

 

 

FLEXIBLE

 

 

 

 

WIRING

BLOWER

 

 

 

 

BOX

3.Connect lexible blower wires to wires in electrical panel wiring box as shown. Cap off BLUE wire (LOW 1).

4.Replace wiring box cover.

B - Remote blower wiring

CAUTION: Installation work and electrical wiring must be done by qualiied person(s) in accordance with all applicable codes, regulations, and standards, including ire-rated construction.

3.The following exterior or inline blowers can be used:

VTR630P - 600 cfm (17 m3/min) Remote Blower VTI610P - 600 cfm (17 m3/min) Inline Blower 120 VAC • 60 Hz • 5.0 A (max.)

4.Install a standard wiring box, with 3-pronged receptacle, within reach of the downdraft’s power cord.

ELECTRICAL PANEL

 

 

GROUND SCREW

 

 

WHITE (NEUTRAL)

M

 

BLUE (LOW 1, CAP OFF)

 

GRAY (MED 2)

 

 

 

 

ORANGE (MED-HIGH 3)

 

 

BLACK (HIGH 4)

REMOTE

14/4 ROMEX

WIRING

BLOWER

OR CONDUIT

BOX

Note: Some blowers may come with plugs or connectors, these should be removed and the 14/4 ROMEX or Conduit wiring should be connected in an approved junction box. As an alternative, the BSH 25'

Extension Cable Kit (EXTNCB25W) and the Extension Cable Connection Kit (EXTNSET4) can be used in place of the ROMEX or conduit wiring. Please follow all required and recommended wiring instructions in this manual and the extension cable kits.

5.Connect power wires to wires in electrical panel wiring box as shown. Cap off Low (Speed 1) wire.

6.Replace wiring box cover.

Page 20