μA741, μA741Y |
|
|
|
GENERAL-PURPOSE OPERATIONAL AMPLIFIERS |
|||||
|
|
SLOS094A ± NOVEMBER 1970 ± REVISED JANUARY 1992 |
|||||
|
|
|
|
|
|
|
|
D |
Short-Circuit Protection |
μA741M . . . J PACKAGE |
|||||
D Offset-Voltage Null Capability |
|
(TOP VIEW) |
|
|
|||
|
|
|
|
|
|
||
D Large Common-Mode and Differential |
NC |
|
|
|
NC |
||
1 |
14 |
|
|||||
|
Voltage Ranges |
|
|||||
|
NC |
2 |
13 |
|
NC |
||
D No Frequency Compensation Required |
|
||||||
OFFSET N1 |
3 |
12 |
|
NC |
|||
|
Low Power Consumption |
|
|||||
D |
IN± |
4 |
11 |
|
VCC + |
||
D |
No Latch-Up |
IN+ |
5 |
10 |
|
OUT |
|
D Designed to Be Interchangeable With |
VCC ± |
6 |
9 |
|
OFFSET N2 |
||
|
Fairchild μA741 |
NC |
7 |
8 |
|
NC |
|
description |
|
|
|
||||
μA741M . . . JG PACKAGE |
|||||||
|
|
μA741C, μA741I . . . D, P, OR PW PACKAGE |
The μA741 is a general-purpose operational amplifier featuring offset-voltage null capability.
The high common-mode input voltage range and the absence of latch-up make the amplifier ideal for voltage-follower applications. The device is short-circuit protected and the internal frequency compensation ensures stability without external components. A low value potentiometer may be connected between the offset null inputs to null out the offset voltage as shown in Figure 2.
(TOP VIEW)
OFFSET N1 |
1 |
8 |
NC |
IN± |
2 |
7 |
VCC+ |
IN+ |
3 |
6 |
OUT |
VCC ± |
4 |
5 |
OFFSET N2 |
μA741M . . . U PACKAGE
(TOP VIEW)
The μA741C is characterized for operation from 0°C to 70°C. The μA741I is characterized for operation from ±40°C to 85°C.The μA741M is characterized for operation over the full military temperature range of ±55°C to 125°C.
symbol
NC |
|
|
1 |
10 |
|
NC |
|
|
|||||
OFFSET N1 |
|
|
2 |
9 |
|
NC |
IN± |
|
|
3 |
8 |
|
VCC + |
IN+ |
|
|
4 |
7 |
|
OUT |
VCC ± |
|
|
5 |
6 |
|
OFFSET N2 |
|
|
|
|
|
|
|
μA741M . . . FK PACKAGE
OFFSET N1 |
|
|
(TOP VIEW) |
|
||
IN + |
+ |
NC |
N1 |
|
|
|
|
OUT |
OFFSET NC NC NC |
|
|||
|
|
|
|
|
|
|
IN ± |
± |
|
|
|
|
|
OFFSET N2 |
|
|
|
|
|
|
|
NC |
3 |
2 |
1 |
20 19 |
NC |
|
4 |
|
|
18 |
||
|
IN± |
5 |
|
|
17 |
VCC + |
|
NC |
6 |
|
|
16 |
NC |
|
IN+ |
7 |
|
|
15 |
OUT |
|
NC |
8 |
|
|
14 |
NC |
|
|
9 |
10 11 12 13 |
|
||
|
|
NC |
CC± |
NC |
N2 NC |
|
|
|
|
V |
|
OFFSET |
|
|
NC ± No internal connection |
|
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
Copyright 1992, Texas Instruments Incorporated
POST OFFICE BOX 655303 •DALLAS, TEXAS 75265 |
1 |
μA741, μA741Y
GENERAL-PURPOSE OPERATIONAL AMPLIFIERS
SLOS094A ± NOVEMBER 1970 ± REVISED JANUARY 1992
AVAILABLE OPTIONS
|
|
|
PACKAGED DEVICES |
|
|
CHIP |
|||
|
|
|
|
|
|
|
|
|
|
|
SMALL |
CHIP |
CERAMIC |
CERAMIC |
|
PLASTIC |
|
FLAT |
|
TA |
|
TSSOP |
FORM |
||||||
OUTLINE |
CARRIER |
DIP |
DIP |
|
DIP |
PACK |
|||
|
|
(PW) |
(Y) |
||||||
|
(D) |
(FK) |
(J) |
(JG) |
|
(P) |
(U) |
||
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
0°C to 70°C |
uA741CD |
|
|
|
|
uA741CP |
uA741CPW |
|
uA741Y |
|
|
|
|
|
|
|
|
|
|
± 40°C to 85°C |
uA741ID |
|
|
|
|
uA741IP |
|
|
|
|
|
|
|
|
|
|
|
|
|
± 55°C to 125°C |
|
uA741MFK |
uA741MJ |
uA741MJG |
|
|
|
uA741MU |
|
|
|
|
|
|
|
|
|
|
|
The D package is available taped and reeled. Add the suffix R (e.g., uA741CDR). |
|
|
|
|
schematic
VCC+
IN ±
OUT
IN+
OFFSET N1
OFFSET N2
VCC ±
Component Count
Transistors 22
Resistors 11
Diode 1
Capacitor 1
2 |
POST OFFICE BOX 655303 •DALLAS, TEXAS 75265 |
μA741, μA741Y
GENERAL-PURPOSE OPERATIONAL AMPLIFIERS
SLOS094A ± NOVEMBER 1970 ± REVISED JANUARY 1992
μA741Y chip information
This chip, when properly assembled, displays characteristics similar to the μA741C. Thermal compression or ultrasonic bonding may be used on the doped-aluminum bonding pads. Chips may be mounted with conductive epoxy or a gold-silicon preform.
BONDING PAD ASSIGNMENTS
(7) (6)
(8)
45
(5)
(1)
(4)
(2) |
(3) |
36
|
|
|
|
|
VCC+ |
||||
IN + |
(3) |
+ |
|
|
(7) |
|
|||
|
|
||||||||
|
|
|
|
|
|||||
|
|
|
|
(6) |
|||||
|
|
|
|
||||||
|
|
|
|
|
|
|
|||
IN ± |
(2) |
± |
|
|
|
|
OUT |
||
|
|
|
|
||||||
|
|
|
|
|
|||||
OFFSET N1 |
|
(1) |
|
|
|
|
(4) |
|
|
OFFSET N2 |
|
(5) |
|
|
VCC ± |
CHIP THICKNESS: 15 TYPICAL BONDING PADS: 4 × 4 MINIMUM TJmax = 150°C.
TOLERANCES ARE ± 10%.
ALL DIMENSIONS ARE IN MILS.
POST OFFICE BOX 655303 •DALLAS, TEXAS 75265 |
3 |
μA741, μA741Y
GENERAL-PURPOSE OPERATIONAL AMPLIFIERS
SLOS094A ± NOVEMBER 1970 ± REVISED JANUARY 1992
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)²
|
|
μA741C |
μA741I |
μA741M |
UNIT |
|
|
|
|
|
|
Supply voltage, VCC+ (see Note 1) |
|
18 |
22 |
22 |
V |
Supply voltage, VCC ± (see Note 1) |
|
±18 |
± 22 |
± 22 |
V |
Differential input voltage, VID (see Note 2) |
|
±15 |
±30 |
±30 |
V |
Input voltage, VI any input (see Notes 1 and 3) |
|
±15 |
±15 |
±15 |
V |
Voltage between offset null (either OFFSET N1 or OFFSET N2) and VCC ± |
±15 |
±0.5 |
±0.5 |
V |
|
Duration of output short circuit (see Note 4) |
|
unlimited |
unlimited |
unlimited |
|
|
|
|
|
|
|
Continuous total power dissipation |
|
See Dissipation Rating Table |
|
||
|
|
|
|
|
|
Operating free-air temperature range, TA |
|
0 to 70 |
± 40 to 85 |
± 55 to 125 |
°C |
Storage temperature range |
|
± 65 to 150 |
± 65 to 150 |
± 65 to 150 |
°C |
|
|
|
|
|
|
Case temperature for 60 seconds |
FK package |
|
|
260 |
°C |
|
|
|
|
|
|
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds |
J, JG, or U package |
|
|
300 |
°C |
|
|
|
|
|
|
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds |
D, P, or PW package |
260 |
260 |
|
°C |
|
|
|
|
|
|
²Stresses beyond those listed under ªabsolute maximum ratingsº may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under ªrecommended operating conditionsº is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, unless otherwise noted, are with respect to the midpoint between VCC+ and VCC ±.
2.Differential voltages are at IN+ with respect to IN ±.
3.The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.
4.The output may be shorted to ground or either power supply. For the μA741M only, the unlimited duration of the short circuit applies at (or below) 125°C case temperature or 75°C free-air temperature.
DISSIPATION RATING TABLE
PACKAGE |
TA ≤ 25°C |
DERATING |
DERATE |
TA = 70°C |
TA = 85°C |
TA = 125°C |
|
POWER RATING |
FACTOR |
ABOVE TA |
POWER RATING |
POWER RATING |
POWER RATING |
||
|
|||||||
D |
500 mW |
5.8 mW/°C |
64°C |
464 mW |
377 mW |
N/A |
|
FK |
500 mW |
11.0 mW/°C |
105°C |
500 mW |
500 mW |
275 mW |
|
J |
500 mW |
11.0 mW/°C |
105°C |
500 mW |
500 mW |
275 mW |
|
JG |
500 mW |
8.4 mW/°C |
90°C |
500 mW |
500 mW |
210 mW |
|
P |
500 mW |
N/A |
N/A |
500 mW |
500 mW |
N/A |
|
PW |
525 mW |
4.2 mW/°C |
25°C |
336 mW |
N/A |
N/A |
|
U |
500 mW |
5.4 mW/°C |
57°C |
432 mW |
351 mW |
135 mW |
|
|
|
|
|
|
|
|
4 |
POST OFFICE BOX 655303 •DALLAS, TEXAS 75265 |