Power Supply Block Diagram
1 EV+1.2V
CL1051
2 EV+1.2V
3 EV+3.3V
4 EV+3.3V
5 EV+3.3V
7 P-ON+5V
8 EV+11V
9 EV+11V
6 P-ON+3.3V
17 PWRCON
P-ON-H
P-ON+44V
SW+44V
Q053,Q054
CAUTION !
Fixed voltage (or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
P-ON+15V
<FROM PIN 67 OF IC501>
13568
13568
CN051A
1 AL+44V13 AL+12V35
CL051A CL051B CN051
AL+12V
5
AL+5V(P-DOWN)
Q055
8
6 AL+5V68 AL+20.5V
AL+9V
AL+5V
SW+9V
Q056
101214
1012141817
P-ON+5V
SW+5V
18
17
TIMER+5V
SW+5V
Q058
Q057
Q059
C-POW-SW
P-DOWN-L
AL+20.5V/+12V
<TO PIN 86 OF IC501>
<FROM PIN 66 OF IC501>
SW+20.5V
Q051,Q052
AL-30V
1
1 AL-30V
CL052A CL052B
IC1002
+1.2V REG.
359
3 AL+2.8V
5 AL+4V
9 F1
IC1003
+3.3V REG.
8F2
8
SW+5V
Q1055
JUNCTION
Q1052
CBA
SW+3.3V
DVD P-ON+5V
-FL
DVD P-ON+3.3V
Q1053,
DVD P-ON+12V
EV+3.3V
F1
SW+12V
Q1054
F2
MAIN CBAPOWER SUPPLY CBA
CAUTION
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,
REPLACE ONLY WITH THE SAME TYPE T1.6AL/250V FUSE.
20
19
T0011
2
BRIDGE
RECTIFIER
D1001 - D1004
NOTE :
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
LINE
L1003
F1001
T1.6AL/250V
AC1001
FILTER
COLD
Q1004
18
17
16
15
14
13
12
11
4
Q1001
Q1003
7
8
IC1001
ERROR
VOLTAGE DET
1
4
23
Q1008
HOT
1-9-5