Teledyne Insta Trans User Manual

4 (1)

OPERATING INSTRUCTIONS FOR

INSTA-TRANS

Trace and Percent Oxygen

Transmitter

P/N M72103 08/02/10

DANGER

Toxic gases and or flammable liquids may be present in this monitoring system. Personal protective equipment may be required when servicing this instrument.

Hazardous voltages exist on certain components internally which may persist for a time even after the power is turned off and disconnected.

Only authorized personnel should conduct maintenance and/or servicing. Before conducting any maintenance or servicing, consult with authorized supervisor/manager.

Teledyne Analytical Instruments

Insta-Trans

Copyright © 2010 Teledyne Analytical Instruments

All Rights Reserved. No part of this manual may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any other language or computer language in whole or in part, in any form or by any means, whether it be electronic, mechanical, magnetic, optical, manual, or otherwise, without the prior written consent of Teledyne Analytical Instruments, 16830 Chestnut Street, City of Industry, CA 91749-1580.

Warranty

This equipment is sold subject to the mutual agreement that it is warranted by us free from defects of material and of construction, and that our liability shall be limited to replacing or repairing at our factory (without charge, except for transportation), or at customer plant at our option, any material or construction in which defects become apparent within one year from the date of shipment, except in cases where quotations or acknowledgements provide for a shorter period. Components manufactured by others bear the warranty of their manufacturer. This warranty does not cover defects caused by wear, accident, misuse, neglect or repairs other than those performed by Teledyne or an authorized service center. We assume no liability for direct or indirect damages of any kind and the purchaser by the acceptance of the equipment will assume all liability for any damage which may result from its use or misuse.

We reserve the right to employ any suitable material in the manufacture of our apparatus, and to make any alterations in the dimensions, shape or weight of any parts, in so far as such alterations do not adversely affect our warranty.

Important Notice

This instrument provides measurement readings to its user, and serves as a tool by which valuable data can be gathered. The information provided by the instrument may assist the user in eliminating potential hazards caused by his process; however, it is essential that all personnel involved in the use of the instrument or its interface, with the process being measured, be properly trained in the process itself, as well as all instrumentation related to it.

The safety of personnel is ultimately the responsibility of those who control process conditions. While this instrument may be able to provide early warning of imminent danger, it has no control over process conditions, and it can be misused. In particular, any alarm or control systems installed must be tested and understood, both as to how they operate and as to how they can be defeated. Any safeguards required such as locks, labels, or redundancy, must be provided by the user or specifically requested of Teledyne at the time the order is placed.

Therefore, the purchaser must be aware of the hazardous process conditions. The purchaser is responsible for the training of personnel, for providing hazard warning methods and instrumentation per the appropriate standards, and for ensuring that hazard warning devices and instrumentation are maintained and operated properly.

Teledyne Analytical Instruments, the manufacturer of this instrument, cannot accept responsibility for conditions beyond its knowledge and control. No statement expressed or implied by this document or any information disseminated by the manufacturer or its agents, is to be construed as a warranty of adequate safety control under the user’s process conditions.

Teledyne Analytical Instruments

ii

Trace Oxygen Transmitter

Specific Model Information

The instrument for which this manual was supplied may incorporate one or more options not supplied in the standard instrument. Commonly available options are listed below, with check boxes. Any that are incorporated in the instrument for which this manual is supplied are indicated by a check mark in the box.

Instrument Serial Number: _______________________

Insta-Trans Transmitter Model: ____________

Cell Class:

A2C

A5

B1

B2C

L2C

B71875 Insta-Trace

B73016 Insta-Trace

Teledyne Analytical Instruments

iii

Insta-Trans

Table of Contents

Cell Class:.....................................................................................

iii

List of Figures ..............................................................................

vi

Introduction ...................................................................................

1

1.1

Overview

1

1.2

Typical Applications

1

1.3

Main Features of the Transmitter

1

1.4

Operator Interface

2

Operational Theory .......................................................................

5

2.1

Introduction

5

2.2

Micro-fuel Cell Sensor

5

2.2.1

Principles of Operation

5

2.2.2

Anatomy of a Micro-fuel Cell

6

2.2.3

Electrochemical Reactions

7

2.2.4

The Effect of Pressure

8

2.2.5

Calibration Characteristics

8

2.3

Sample System

10

2.4

Electronics and Signal Processing

11

Installation ...................................................................................

13

3.1

Unpacking the Transmitter

13

3.2

Mounting the Transmitter

13

3.3

Gas Connections

13

3.4

Electrical Connections

15

3.5

Installing the Micro-fuel Cell

16

3.6

Testing the System

17

Operation .....................................................................................

19

4.1

Introduction

19

 

 

 

 

 

 

Teledyne Analytical Instruments

iv

Trace Oxygen Transmitter

4.2

The Range and Calibration Functions

19

4.3

Calibration

20

Maintenance.................................................................................

23

5.1

Routine Maintenance

23

5.2

Cell Replacement

23

5.2.1 Storing and Handling Replacement Cells

23

5.2.2 When to Replace a Cell

24

5.2.3 Removing the Micro-fuel Cell

24

5.2.4 Cell Warranty

24

5.3

Insta-Trace Sensor

26

Appendix ......................................................................................

29

Specifications

29

Recommended Spare Parts List

30

Drawings

32

Teledyne Analytical Instruments

v

Insta-Trans

List of Figures

Figure 1-1: Range Selection............................................................

3

Figure 2-1: Micro-fuel Cell...............................................................

6

Figure 2-2: Cross Section of a Micro-fuel Cell.................................

7

Figure 2-3: Characteristic Input/Output Curve for a Micro-fuel Cell.......

9

Figure 2-4: Gas and Other Connections to the Transmitter ..........

10

Figure 2-5: Electronics Block Diagram ..........................................

12

Figure 3-1: Insta-Trans Connections and Mounting Dimensions...

14

Figure 4-1: Insta-Trace Operation .................................................

21

Figure 5-1: Cell Removal ..............................................................

26

Figure 5-2: Cell Removal Insta-Trace ...........................................

28

Teledyne Analytical Instruments

vi

Trace Oxygen Transmitter

DANGER

COMBUSTIBLE GAS USAGE

WARNING

This is a general purpose instrument designed for usage in a nonhazardous area. It is the customer's responsibility to ensure safety especially when combustible gases are being analyzed since the potential of gas leaks always exist.

The customer should ensure that the principles of operating of this equipment is well understood by the user. Misuse of this product in any manner, tampering with its components, or unauthorized substitution of any component may adversely affect the safety of this instrument.

Since the use of this instrument is beyond the control of Teledyne, no responsibility by Teledyne, its affiliates, and agents for damage or injury from misuse or neglect of this equipment is implied or assumed.

Teledyne Analytical Instruments

vii

Insta-Trans

Teledyne Analytical Instruments

viii

Trace Oxygen Transmitter

Introduction

 

 

 

 

 

 

Introduction

1.1 Overview

The Teledyne Analytical Instruments Insta-Trans Trace Oxygen Transmitter is a versatile instrument for detecting oxygen at the parts-per- million (ppm) level in a variety of gases. This manual covers the Insta-Trans Trace Oxygen Transmitter. These units are NEMA-4 rated and may be used in hazardous environments. The Insta-Trans is also Factory Mutual approved when installed in accordance with drawing D-73226 located in the back of this manual.

1.2 Typical Applications

A few typical applications of the Insta-Trans are:

Monitoring inert gas blanketing

Air separation and liquefaction

Chemical reaction monitoring

Semiconductor manufacturing

Petrochemical process control

Quality assurance

Gas analysis certification.

1.3Main Features of the Transmitter

The Insta-Trans Trace Oxygen Transmitter is sophisticated yet simple to use. The main features of the analyzer include:

3½ digit LCD display with range and calibration annunciators.

Six ranges: 0-10 ppm through 0-25%.

Stainless steel cell block.

Teledyne Analytical Instruments

1

Introduction

Insta-Trans

 

 

 

 

 

 

Simple push-button calibration and range selection.

Advanced Micro-fuel Cell, redesigned for trace analysis, has a one year warranty and an expected lifetime of two years.

Air-calibration range for convenient spanning at 20.9 %.

True 2-wire 4-20 mA powered loop interface.

1.4Operator Interface

The standard Insta-Trans is housed in a rugged NEMA-4 rated metal case with all switches and the display accessible from the outside. Figure 1-1 illustrates the Insta-Trans display and switches while Table 1- 1 shows the decimal point (DP) location for the various ranges.

Function Keys: Six touch-sensitive membrane switches are used to set the range and calibrate the transmitter.

RANGE Selects the Range mode and sets the desired range.

COARSE Selects the Coarse calibration mode.

FINE Selects the Fine calibration mode.

RUN Selects the Run mode.

 

Used to adjust the calibration upward in Coarse

 

 

and Fine mode.

 

Used to adjust the calibration downward in

 

 

Coarse and Fine mode.

DISPLAY 3 1/2 digit O2 concentration LCD display with

 

 

annunciators

Table 1-1: Decimal Location for Selected Range

 

 

 

 

 

Range

 

Decimal Location

 

0-10 PPM

 

Decimal Point (DP) 2

 

0-100 PPM

 

Decimal Point (DP) 1

 

0-1000 PPM

 

No Decimal Point

 

0-1%

 

Decimal Point (DP) 3

 

0-10%

 

Decimal Point (DP) 2

 

0-25%

 

Decimal Point (DP) 2

Teledyne Analytical Instruments

2

Teledyne Insta Trans User Manual

Trace Oxygen Transmitter

Introduction

 

 

 

 

 

 

Figure 1-1: Range Selection

Teledyne Analytical Instruments

3

Introduction

Insta-Trans

 

 

 

 

 

 

Teledyne Analytical Instruments

4

Loading...