Teledyne 3110 User Manual

4.7 (3)

OPERATING INSTRUCTIONS FOR

Model 3110

Portable Trace Oxygen Analyzer

P/N M77970 10/16/2005 ECO:

DANGER

Toxic gases and or flammable liquids may be present in this monitoring system.

Personal protective equipment may be required when servicing this instrument.

Hazardous voltages exist on certain components internally which may persist for a time even after the power is turned off and disconnected.

Only authorized personnel should conduct maintenance and/or servicing. Before conducting any maintenance or servicing, consult with authorized supervisor/manager.

Copyright © 2005 Teledyne Analytical Instruments

Teledyne Analytical Instruments

Model 3110

All Rights Reserved. No part of this manual may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any other language or computer language in whole or in part, in any form or by any means, whether it be electronic, mechanical, magnetic, optical, manual, or otherwise, without the prior written consent of Teledyne Instruments / Analytical Instruments, 16830 Chestnut Street, City of Industry, CA 91748.

Warranty

This equipment is sold subject to the mutual agreement that it is warranted by us free from defects of material and of construction, and that our liability shall be limited to replacing or repairing at our factory (without charge, except for transportation), or at customer plant at our option, any material or construction in which defects become apparent within one year from the date of shipment, except in cases where quotations or acknowledgements provide for a shorter period. Components manufactured by others bear the warranty of their manufacturer. This warranty does not cover defects caused by wear, accident, misuse, neglect or repairs other than those performed by TAI or an authorized service center. We assume no liability for direct or indirect damages of any kind and the purchaser by the acceptance of the equipment will assume all liability for any damage that may result from its use or misuse.

We reserve the right to employ any suitable material in the manufacture of our apparatus, and to make any alterations in the dimensions, shape or weight of any parts, in so far as such alterations do not adversely affect our warranty.

Important Notice

This instrument provides measurement readings to its user, and serves as a tool by which valuable data can be gathered. The information provided by the instrument may assist the user in eliminating potential hazards caused by his process; however, it is essential that all personnel involved in the use of the instrument or its interface, with the process being measured, be properly trained in the process itself, as well as all instrumentation related to it.

The safety of personnel is ultimately the responsibility of those who control process conditions. While this instrument may be able to provide early warning of imminent danger, it has no control over process conditions, and it can be misused. In particular, any alarm or control systems installed must be tested and understood, both as to how they operate and as to how they can be defeated. Any safeguards required such as locks, labels, or redundancy, must be provided by the user or specifically requested of TAI at the time the order is placed.

Therefore, the purchaser must be aware of the hazardous process conditions. The purchaser is responsible for the training of personnel, for providing hazard warning methods and instrumentation per the appropriate standards, and for ensuring that hazard warning devices and instrumentation are maintained and operated properly.

Teledyne Analytical Instruments, the manufacturer of this instrument, cannot accept responsibility for conditions beyond its knowledge and control. No statement expressed or implied by this document or any information disseminated by the manufacturer or its agents, is to be construed as a warranty of adequate safety control under the user’s process conditions.

ii

Teledyne Analytical Instruments

Portable Trace Oxygen Analyzer

Specific Model Information

Instrument Serial Number: _______________________

Teledyne Analytical Instruments

iii

Model 3110

Safety Messages

Your safety and the safety of others is very important. We have provided many important safety messages in this manual. Please read these messages carefully.

A safety message alerts you to potential hazards that could hurt you or others. Each safety message is associated with a safety alert symbol. These symbols are found in the manual and inside the instrument. The definition of these symbols is described below:

No

Symbol

GENERAL WARNING/CAUTION: Refer to the instructions for details on the specific danger. These cautions warn of specific procedures which if not followed could cause bodily Injury and/or damage the instrument.

CAUTION: HOT SURFACE WARNING: This warning is

specific to heated components within the instrument. Failure to heed the warning could result in serious burns to skin and underlying tissue.

WARNING: ELECTRICAL SHOCK HAZARD: Dangerous

voltages appear within this instrument. This warning is specific to an electrical hazard existing at or nearby the component or procedure under discussion. Failure to heed this warning could result in injury and/or death from electrocution.

Technician Symbol: All operations marked with this symbol are to be performed by qualified maintenance personnel only.

NOTE: Additional information and comments regarding a specific component or procedure are highlighted in the form of a note.

CAUTION: THE ANALYZER SHOULD ONLY BE USED FOR THE PURPOSE AND IN THE MANNER DESCRIBED IN THIS MANUAL.

iv

Teledyne Analytical Instruments

Portable Trace Oxygen Analyzer

IF YOU USE THE ANALYZER IN A MANNER OTHER THAN THAT FOR WHICH IT WAS INTENDED, UNPREDICTABLE BEHAVIOR COULD RESULT POSSIBLY ACCOMPANIED WITH HAZARDOUS CONSEQUENCES.

This manual provides information designed to guide you through the installation, calibration operation and maintenance of your new analyzer. Please read this manual and keep it available.

Occasionally, some instruments are customized for a particular application or features and/or options added per customer requests. Please check the front of this manual for any additional information in the form of an Addendum which discusses specific information, procedures, cautions and warnings that may be peculiar to your instrument.

Manuals do get lost. Additional manuals can be obtained from TAI at the address given in the Appendix. Some of our manuals are available in electronic form via the Internet. Please visit our website at: www.teledyne-ai.com.

Teledyne Analytical Instruments

v

Model 3110

Table of Contents

List of Figures............................................................................

viii

Introduction ................................................................................

10

1.1

Introduction

10

1.2

Features

11

1.3

Method of Analysis

13

1.4

Micro-Fuel Cell

13

1.4.1 Cell Warranty

13

1.5

Accuracy and Response

14

1.6

Signal Output

14

1.7

Compact Packaging

14

Installation ..................................................................................

17

2.1

Charging the Batteries

17

2.2

Gas Connections

18

2.3

Sensor Installation

20

2.3.1 Installing a Trace Sensor

20

2.4

Calibration

21

2.4.1 Calibration Procedure for Trace Analysis

21

2.4.2 Bleeding the Regulator and Purging the Gas Line

22

2.5

Set the Sample Flow rate

22

2.6

External Signal

23

Operation ....................................................................................

24

3.1

Front Panel Interface

24

3.1.1 ENTER Key

24

3.1.2 ESCAPE Key

25

3.1.3 UP/DOWN Keys

25

3.2

Operation and Setup Screens and Menus

26

3.2.1 POWER ON Screen

27

3.2.2 HOME Screen

27

vi

Teledyne Analytical Instruments

Portable Trace Oxygen Analyzer

3.2.3 DATE Screen

27

3.2.4 TIME Screen

28

3.2.5 STANDARD ALARM Screen

29

3.2.6 ALARM Enable

29

3.2.7 FS ALARM Screen

30

3.2.8 HI-LOW ALARM Screen

30

3.2.9 LTCH ALARM Screen

31

3.2.10 RANGE 1 Screen

32

3.2.11 RANGE 2 Screen

32

3.2.12 Range Screen

33

3.2.13 SPAN VALUE Screen

34

3.2.14 SPAN Screen

34

3.2.15 Filter Screen

35

3.2.16 LOG INTV Screen

36

3.2.17 LOG RESET & START Screen

36

3.2.18 LOG TRANSMIT Screen

37

3.2.19 POWER DOWN Screen

38

Maintenance & Troubleshooting................................................

40

4.1

Routine Maintenance

40

4.2

Opening the Instrument Case

40

4.3

Replacing the Battery

40

4.4

Battery Power Supply Service

41

4.5

Cell Replacement

42

4.6

Cell Warranty

43

4.7

Temperature Compensation

44

4.8

Leak Testing

46

Appendix .....................................................................................

48

A.1 Specifications

48

A.2 Spare Parts List

49

Index

............................................................................................

50

Teledyne Analytical Instruments

vii

Model 3110

List of Figures

 

Figure 2-1: Model 3110 Rear Panel..............................................

18

Figure 3-1: Front Panel Keys........................................................

25

Figure 3-2: Available Menus and Their Sequence ........................

26

Figure 4-1: Battery Charger Port on the Model 3110 ....................

42

viii

Teledyne Analytical Instruments

Portable Trace Oxygen Analyzer

DANGER

COMBUSTIBLE GAS USAGE

WARNING

This is an intrinsically safe instrument which can be used in hazardous areas. It is the customer's responsibility to ensure safety especially when combustible gases are being analyzed since the potential of gas leaks always exist.

The customer should ensure that the principles of operating this equipment are well understood by the user. Misuse of this product in any manner, tampering with its components, or unauthorized substitution of any component may adversely affect the safety of this instrument.

Since the use of this instrument is beyond the control of Teledyne Analytical Instruments, referred as TAI, no responsibility by TAI, its affiliates, and agents for damage or injury from misuse or neglect of this equipment is implied or assumed.

Teledyne Analytical Instruments

ix

Introduction

Model 3110

 

 

 

 

Introduction

1.1 Introduction

The Teledyne Analytical Instruments (TAI) Model 3110 Portable Trace Oxygen Analyzer is a portable, intrinsically safe oxygen analyzer capable of analyzing oxygen levels from 2 parts per million (ppm) oxygen.

The instrument operates from internal rechargeable batteries and is supplied with a universal AC charge adapter. Featuring quick disconnect fittings for sample connections and a rugged lightweight housing with handle, this versatile instrument can be brought to the sample site and set up for analysis quickly and easily. Because of the intrinsically safe design, once calibrated, the instrument can be employed even in hazardous environments without compromise. The Model 3110 incorporates a large standard feature list designed for versatile, accurate oxygen analysis for a wide range of applications. Figure 1-1 shows the standard Model 3110 Portable Trace Oxygen Analyzer.

The microprocessor based Model 3110 instrument provides user settable analysis ranges at the trace level. The range can be set from 0-2 ppm to 0-25% oxygen. In auto-ranging mode two ranges can be set and the analyzer move between these ranges as required. The adjustment resolution is 0.1 ppm for trace analysis.

Sample oxygen is displayed on a 2-line 20 character alphanumeric LCD display mounted on the front panel. Four buttons are used to interface with the instrument and access all of the analyzer features.

Sample gas is introduced and vented via a pair of quick-disconnect fittings that feature integral shutoff valves that automatically close when the mating male fitting is withdrawn. The fittings are an integral part of the measuring cell manifold.

10

Teledyne Analytical Instruments

Teledyne 3110 User Manual

Portable Trace Oxygen Analyzer

Introduction

 

 

 

 

WARNING Though the 3110 can be applied to monitor percent oxygen, doing so will lead to more frequent sensor replacement requirements.

Figure 1-1: Model 3110 Portable Trace Oxygen Analyzer

1.2 Features

This instrument is designed to be a versatile analytical instrument and to perform reliably and accurately in analyzing oxygen concentrations in gas mixtures from the ppm level through 25% oxygen. The following features are standard on the Model 3110:

Data Logger: The optional built-in data logging feature

allows the user to specify the time interval between data recording sets. The date, time, and oxygen concentration readings are stored in internal RAM at the user specified interval. The data set can be

Teledyne Analytical Instruments

11

Introduction

Model 3110

 

 

 

 

downloaded using the instrument’s optional RS-232 interface.

Display: A 2-line 20 character alphanumeric LCD

on the front panel displays data and operational information through various screens. The contrast is adjustable for various lighting conditions.

Four-Button User Interface: Operation is performed using the

four front panel mounted buttons. These buttons are used to enter data, select items and move through operational screens that appear on the display.

Universal AC Charge Adapter: The rechargeable batteries can

be recharged without removing them from the instrument. The charger operates over the range of 100-240 VAC.

LEDs: Two front panel mounted LEDs are used

to indicate low battery condition and when the battery is recharging.

Contrast Control: This feature allows the user to easily

adjust the contrast of the display for optimum viewing under different lighting conditions. The adjustment is made using a front panel control dial.

Auto-ranging: The user is able to specify two analytical

ranges for analysis in the auto mode. The Model 3110 will automatically switch between these ranges depending on the oxygen level.

Percent of Range Voltage Output: An optional 0-1 VDC

output is available that represents the percentage of the current analysis range.

Real-time Clock: This feature allows the Model 3110 to date

and time stamp the data set recorded on the data logger. It uses a 24 hour clock.

12

Teledyne Analytical Instruments

Portable Trace Oxygen Analyzer

Introduction

 

 

 

 

Quick Disconnect Fittings: Dual self-sealing quick disconnect

fittings are installed for making easy sample connections.

1.3 Method of Analysis

The sample oxygen is measured by a unique electrochemical transducer which functions as a fuel cell; in this instance, the fuel is oxygen. Oxygen diffusing into the cell reacts chemically to produce an electrical current that is proportional to the oxygen concentration in the gas phase immediately adjacent to the transducer’s sensing surface. The linear, but minute signal produced by the transducer from oxygen is amplified by a two-stage amplifier. The O2 sensor output signal is digitized and fed to the microprocessor. Additional signal conditioning and temperature compensation are handled electronically and appropriate signals are directed to the display and output ports.

1.4 Micro-Fuel Cell

The micro-fuel cell (U.S. Pat. Nos. 3,767,552 and 3,668,101) is a sealed electrochemical transducer with no electrolyte to change or electrodes to clean. When the cell reaches the end of its useful life, it is removed, properly disposed of, and replaced with a new cell. The life of the cell is warranted by TAI (see below).

The cell is specific for oxygen and is not sensitive to flow rate or reducing agents such as hydrocarbons, carbon monoxide, sulfur dioxide, etc. In the absence of oxygen, no current is produced; thus, no zeroing is required.

1.4.1 Cell Warranty

The Class B2-C, A2C, B2C-XL and Insta Trace micro-fuel cells can be used in the Model 3110 and are warranted for six (6) months from the date of shipment.

With regard to spare cells, service time starts when the cell is removed from its shipping package. You should stock only one spare cell per instrument at a time.

If a cell was working satisfactorily but ceases to function before the warranty period expires, the sensor will be replaced at no cost.

Teledyne Analytical Instruments

13

Introduction

Model 3110

 

 

 

 

If you have a warranty claim, return the cell in question to the factory for evaluation. If it is determined that failure is due to faulty workmanship or material, the cell will be replaced at no cost to you.

WARNING: EVIDENCE OF DAMAGE DUE TO TAMPERING OR MISHANDLING WILL RENDER THE CELL WARRANTY NULL AND VOID.

The Model 3110 is designed to meet Factory Mutual standards for intrinsically safe for Class I, Division I, Groups A, B, C and D hazardous locations. (Approval pending at time of manual printing.)

This safety feature does not apply when the instrument is being charged with the 100240 VAC external charge adapter. The instrument should be removed from hazardous areas when the batteries are being charged.

Note: Do not use the analyzer when the battery charge is low.

1.5 Accuracy and Response

The Model 3110 provides monitoring accuracies of ±2% of full scale or ±1 ppm, whichever is greater, at constant temperature.

With a sample flow rate of 1 SCFH, a 90% response can be realized in 60 seconds. The response time on the 3110 is limited by the filter setting.

1.6 Signal Output

The standard 0-1 VDC output has a 100 ohm impedance and is suitable for driving external devices that have an input impedance of 10,000 Ω or more. The signal output is available from a port on the rear panel.

1.7 Compact Packaging

The instrument is housed in 6 1/8"× ½9" × 5 5/8" (156×

241×

143 mm) aluminum case that is equipped with a carrying handle and foot pads. Unlike analog instruments where uneven positioning may

14

Teledyne Analytical Instruments

Portable Trace Oxygen Analyzer

Introduction

 

 

 

 

affect meter accuracy, the Model 3110 can be used in any position without interference.

Teledyne Analytical Instruments

15

Introduction

Model 3110

 

 

 

 

Intentionally left blank.

16

Teledyne Analytical Instruments

Loading...
+ 36 hidden pages