Sven Pro+ 1000, Pro+ 600, Pro+ 1500, Pro+ 650 LCD, Pro+ 650 USB Operation Manual

...
www.sven.
OPERATION MANUAL
Uninterruptible Power Supply
PRO+
1
Operation Manual
PRO+
CONTENTS
ENG .................................................................................................
1. PRECAUTIONS .......................................................................................
2. SPECIAL FEATURES ................................................................................
3. PACKAGE CONTENTS ............................................................................
4. OPERATING PRINCIPLE ..........................................................................
5. DESCRIPTION .....................................................................................
6. MAIN FUNCTIONS ............................................................................
7. CONNECTION ......................................................................................
8. BATTERY MAINTENANCE ........................................................................
9. TROUBLESHOOTING .............................................................................
10. TECHNICAL SPECIFICATIONS ..................................................................
Technical support is on www.sven.
1 2 3 3 3 4 5 5 6 6 7
Congratulations on your purchase of the Sven uninterruptible power supply!
Please read this Оperation Мanual before using the unit and retain this Оperation Мanual in a safe place for future reference.
COPYRIGHT
© 2014. SVEN PTE. LTD. Version 1.0 (V 1.0). This Мanual and information contained in it are copyrighted. All rights reserved.
TRADEMARKS
All trademarks are the property of their legal holders.
NOTICE OF RESPONSIBILITY RESTRICTION
Despite the exerted efforts to make this Мanual more exact, some discrepancies may occur. The information of this Мanual is given on “as is” terms. The author and the publisher do not bear any liability to a person or an organization for loss or damages which have arisen from the information, contained in the given Мanual.
UNPACKING
Unpack the device carefully. Make sure there are no accessories left in the box. Check up the device for damages; if the product was damaged during transportation, address the rm which carried out the delivery; if the product functions incorrectly, address the dealer at once.
2
Uninterruptible Power Supply
1. PRECAUTIONS
Before operating this device, please carefully read the following safety instructions:
Before switching on the Uninterruptible Power Supply (UPS) in the electric mains for the rst time, it is necessary to charge the storage battery for at least 12 hours. For this purpose the UPS should be switched on without load.
If the storage battery has fully run down or the UPS has not been operated for three months, it is also necessary to charge the storage battery for at least 12 hours. Otherwise, its durability will be considerably reduced .
The UPS is designed solely for operation with PCs equipped with switching power supply units*. It is strongly forbidden to connect inductive or capacitive load, as well as fully resistive load. Such loads include any devices with transformer power unit, electric engines, uorescent lamps, laser printers, any heating appliances, etc.
During operation, the case of the device can be heated up to 50 °C, which is absolutely normal.
It is strongly forbidden to open case of the device, as there is high voltage inside. If some prob-
lems occur, please address an authorized service centre. For the list of authorized service centres please go to www.sven..
Do not let liquid and foreign objects get inside the device, it can cause short circuit or electric shock.
In case there are signs of improper operation of the device (sparkling, unusual smells, etc.), it is necessary to turn o the device immediately and disconnect it from the mains, and address your nearest authorized service centre.
It is forbidden to connect the UPS to equipment with power consumption higher than its maximum output power. It can cause overload and breakdown of the device.
It is strongly forbidden to operate the device in following conditions:
in dusty environment or environment containing highly inammable gas;
at temperature higher than 40 °C or lower than 0 °C;
at relative humidity level higher than 90 %;
in direct sunlight or next to heating elements;
in vibration places;
outdoors.
In case of re use only powder re extinguisher, as using water can cause electric shock.
Try to install the UPS in proximity to power supply, in such way it will be easier to unplug the device
if necessary.
*The device operation is not guaranteed when connecting UPS with APFC (active power factor correction).