Designation Description Repair
Er06 EPO Inverter enters into
EPO mode (Emerge
Power Off).
1. Remove the short circuit
occurred at the EPO terminal.
2. If error code keeps
recurring, contact your local
distributor.
Er09 Inverter Output
over-current
Over-current on the
AC side. This fault
code is displayed
if the current in
the AC network
is larger than
specified.
1. Turn off AC breaker, and
then check the peripheral AC
system configuration and the
grid conditions.
2. If error code keeps
recurring, contact your local
distributor for help.
Er11 Inverter over-load Overload on the
AC side. This fault
code is displayed if
the load in the AC
network is larger
than specified.
Contact your local distributor
for help.
Er13 Inverter
short-circuit
Short-circuit on the
AC side.
Contact your local distributor
for help.
Er14 Inverter PLL fail The phase of
Inverter can’t
synchronize with
the utility.
Contact your local distributor
for help.
Er29 Inverter output
DC current over
spec.
The DC component
of the electricity
fed into the grid
is longer than the
permissible range.
Contact your local distributor
for help.
Er10 Inverter Over
temperature
The internal
temperature is too
high.
1. Try to reduce the ambient
temperature.
2. Move the inverter to a
cooler place.
3. If error code keeps
recurring, contact your local
distributor for help.
Er18 Heat Sink Over
temperature
The Heat Sink
temperature is too
high.
Contact your local distributor
for help.