Planning Information
Integrated Model 736TC(I)
Over-and-Under Refrigerator / Freezer
|
Electronic digital |
Seamless |
|
control panel |
molding |
|
Adjustable spill-proof |
Adjustable dairy |
|
glass shelves |
compartment |
|
Egg container |
Adjustable door |
|
|
shelves |
Model 736TC |
High-humidity |
|
crisper drawer |
|
|
|
|
|
|
Location of serial |
Magnetic door/ |
|
number |
drawer gaskets |
|
Automatic ice maker |
Upper freezer |
|
(Model 736TCI) |
storage drawer |
Model 736TCI |
|
|
with Ice Maker |
|
|
|
Front venting with |
Lower freezer |
|
removable kickplate |
storage drawer |
The Sub-Zero Model 736TC and 736TCI integrated design accepts custom wood or stainless steel door and drawer panels. Stainless steel panels and handles are available as sales accessories in three finishes—classic, platinum and carbon.
Dimensions in parentheses are in millimeters unless otherwise specified.
With the installation of a harness kit, these appliances are Star-K compliant to meet strict religious regulations in conjunction with specific instructions found on star-k.org. You may purchase this harness kit through your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com.
The Integrated line of refrigeration is growing—literally and figuratively. We’ve introduced the Model 700BC that takes integrated refrigerator and freezer space to the base unit and now we have grown the same concept to 36" (914). Yes, that’s correct, the Integrated line is not only 27" (686) wide, you can order a tall combination unit that is 36" (914) wide.
This unit will be perfect for those smaller kitchens that required more storage space than the Model 700TC could offer.
All of the panel specifications are identical to the 27" (686) wide tall models, except they have grown 9" (229) wider.
1
11/06
Planning Information
Integrated Model 736TC(I)
F E A T U R E S
Tall 36" (914) wide combination unit with upper cabinet refrigerator and freezer storage drawers
Model 736TCI has automatic ice maker
Integrated design for "point-of-use" refrigeration anywhere in the home
Dual refrigeration system with two distinct temperature zones ensures the freshest food and energy efficiency
Electronic digital controls are up front and easy to use
Flat to the ceiling bright lighting in cabinet and drawers
Door alarm will let you know with an audible beeping if a door or drawer is left open
Adjustable, spill-proof glass shelves
Crisper with dividers is large and deep, with smooth sides for easy cleaning
The exclusive dual-action hinge has a built-in 90˚ door stop
Meets strict Department of Energy requirements
UL approved for US and Canada
Two, five and twelve year residential warranty – exclusions apply; warranty information can be found on our website, subzero.com
O V E R A L L D I M E N S I O N S
|
36" |
|
(914) |
|
(UNIT DIMENSION) |
|
14"(356) |
|
DOOR MOUNTING |
|
DETAIL |
3/8" |
|
(10) |
|
131/4" |
DRAWER MOUNTING |
1/2" (337) |
DETAIL |
(13) |
|
101/4" |
|
(260) |
|
203/8" |
|
(518) |
|
FRONT VIEW
|
24" |
|
TOP OF |
(610) |
|
(UNIT DIMENSION) |
||
ROUGH |
||
|
||
OPENING |
|
|
15/16" |
|
|
(33) |
|
|
80"* |
|
|
(2032) |
|
|
7713/16"* |
|
|
(1976) |
|
|
341/2"* |
|
|
(876) |
|
|
93/4" |
|
|
(248) |
|
|
4" |
SIDE VIEW |
|
(102) |
*1/2" (13) + ADJUSTMENT IN LEVELING LEGS
Dimensions may vary by ±1/8" (3).
|
24" |
|
|
(610) |
|
DOOR/DRAWER |
|
DOOR/DRAWER |
CLOSED |
|
CLOSED |
90˚ |
191/2"* |
|
341/2"* (495) |
105˚ |
|
|
(876) |
|
|
|
|
|
|
347/8" (886) |
90˚ DOOR OPENING |
MAXIMUM DOOR OPENING |
7"* |
|
|
|
|
|
(178) |
TOP VIEW
*DOOR/DRAWER PANEL THICKNESS NOT INCLUDED – DIMENSION WILL VARY WITH INSTALLATION
Dimensions in parentheses are in |
|
millimeters unless otherwise specified. |
2 |
Planning Information
Integrated Model 736TC(I)
M O D E L O P T I O N S
Tall Combination Unit |
|
736TC |
Tall Combination Unit |
|
|
with Automatic Ice Maker |
736TCI |
|
P A N E L O P T I O N S |
|
|
|
|
|
Integrated (custom panels) |
|
|
Classic Stainless Steel Finish |
|
/S |
Platinum Stainless Steel Finish |
/P |
|
Carbon Stainless Steel Finish |
|
/B |
Stainless steel door and drawer front panels are ordered and shipped as sales accessories and include tubular handles.
A C C E S S O R I E S
Door and drawer front panels with tubular handles in classic, platinum and carbon stainless steel
Tubular handles in classic, platinum and carbon stainless steel and polished chrome
Deli drawer and shelf assembly
Dozen egg container with lid
Dual installation heater kit
Accessories are available through your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com.
S P E C I F I C A T I O N S
Model 736TC(I) |
Upper Cabinet Refrigerator |
|
with Freezer Drawers |
|
|
Overall Width |
36" (914) |
|
|
Overall Height |
80" (2032) |
|
|
Overall Depth |
24" (610) |
|
|
Refrigerator Capacity |
13.5 cu ft (383 L) |
|
|
Freezer Capacity |
6.9 cu ft (195 L) |
|
|
Minimum Height (levelers in) |
791/2" (2019) |
Door Clearance |
341/2" (876) |
Drawer Clearance |
191/2" (495) |
Electrical Requirements |
115 V AC, 60 Hz, 15 amp circuit |
|
|
|
|
Plumbing Requirements |
1/4" copper line |
|
Water Supply |
|
20–100 psi |
|
|
|
Annual Energy Usage |
569 kWh / $52 |
|
(based on 9.06 cents per kilowatt hour) |
||
|
|
|
Shipping Weight |
|
480 lbs (218 kg) |
|
|
|
Special Note |
Door and drawer panels and handles are |
|
|
available in three stainless steel finishes |
|
|
|
|
Specifications are subject to change without notice.
Dimensions in parentheses are in |
|
millimeters unless otherwise specified. |
3 |
Planning Information
Integrated Model 736TC(I) |
|
|
|
|
I N S T A L L A T I O N S P E C I F I C A T I O N S |
|
|
|
|
|
TOP VIEW |
|
TOP VIEW |
|
|
ANTI-TIP |
|
6" |
|
|
|
(152) |
|
|
11/2" BRACKET* |
|
ANTI-TIP |
||
(38) |
18" (457) |
|
|
BRACKET |
25" |
|
27" |
18" (457) |
|
|
|
27" |
||
(635) |
20" (508) |
131/2" |
(686) |
(686) |
|
|
WATER LINE |
||
|
|
(343) |
|
|
|
|
|
SIDE ENTRY |
|
|
|
|
|
|
|
|
WATER LINE |
|
LOCATIONS |
|
|
BOTTOM ENTRY |
|
|
|
|
LOCATION |
|
|
|
|
*PLACEMENT OF THE |
|
11/2" |
|
|
ANTI-TIP BRACKET |
|
(38) |
|
|
SHOULD BE 24" (610) |
|
|
|
|
FROM THE FRONT OF THE |
|
|
|
|
UNIT WITHOUT PANELS |
|
36" |
|
|
TO THE BACK OF THE |
|
|
|
|
|
(914) |
|
|
|
ANTI-TIP BRACKET. |
|
|
|
|
|
|
|
|
LOCATE ELECTRICAL WITHIN |
|
|
|
|
SHADED AREA – ORIENT GROUND |
|
|
|
|
PRONG TO RIGHT AS SHOWN |
|
|
|
|
ANTI-TIP |
LOCATE WATER LINE |
|
|
|
BRACKET |
(REAR ENTRY) WITHIN |
80" |
|
|
|
SHADED AREA |
||
|
|
(2032) |
||
|
|
|
|
|
41/2" |
|
|
|
3" |
(114) |
|
|
|
|
|
|
|
(76) |
|
|
|
|
|
|
1/4" |
171/2" (445) |
131/2" |
3/4" |
|
|
(343) |
|||
(6) |
21/2" (64) |
|
(19) |
|
|
|
|
||
|
|
20" (508) |
|
|
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
11/2"
(38)
25"
(635)
WATER LINE
SIDE ENTRY
ANTI-TIP LOCATION BRACKET
|
|
|
|
FRONT VIEW |
SIDE VIEW |
D I M E N S I O N S
Finished Rough Opening Width |
36" (914) |
|
|
Finished Rough Opening Height |
80" (2032) |
|
|
Finished Rough Opening Depth |
25" (635)* |
|
|
Location of Electrical |
Within shaded area |
|
|
Location of Plumbing (Model 736TCI only) |
Within shaded area |
|
|
*The depth of the Model 736TC(I) is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635).
See Installation Instructions shipped with unit for detailed specifications.
Dimensions in parentheses are in |
|
millimeters unless otherwise specified. |
4 |
Planning Information
Integrated Model 736TC(I)
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics.
IMPORTANT NOTE: The depth of Model
736TC(I) is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the installation illustration on page 4.
The anti-tip bracket must be installed to prevent the unit from tipping forward.
Integrated units are compatible with virtually any style of cabinetry. They can be used with framed as well as frameless cabinets.
Refer to the full-scale illustrations at the end of this section for specifics on panels and door openings.
Door panels can grow beyond 453/8"(1153) and exceed the 80" (2032) height to accommodate any size of door as long as you stay below the recommended door panel weight limit of 53 lbs (24 kg). Door panels must be a minimum of 5/8" (16) thick.
The weight of each drawer panel cannot exceed 16 lbs (7 kg). Drawer panels must be a minimum of 5/8" (16) thick.
For the bottom drawer, the maximum panel height is 1611/16" (424). You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel, so the unit can be properly vented. Any decorative base molding must be removable for possible servicing and cleaning of the condenser.
We recommend using D-style handles, which should be located on the opposite side from the hinge, centered on the cabinet door and the top, center area of the drawer panel.
Two Integrated units may be installed next to one another. Refer to page 11 for additional information.
For Integrated models with an automatic ice maker, rough in the water supply line. Connect a 1/4" OD copper line to the house supply, being sure to use an easily accessible shut-off valve between the supply and the unit. This shut-off valve should not be installed behind the unit.
Dimensions in parentheses are in
Do not use self-piercing valves. A saddle valve kit (4200880) is available from your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com.
A line filter is required when water conditions have a high sediment content. The ice maker operates on water pressure of 20 psi (1.4 bar) to 100 psi (6.9 bar). In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently.
When routing the water through the side walls, you must place the water line within 1/2" (13) of the floor and as close as possible to the back wall. The line must be routed around the anti-tip bracket so it clears the bracket and leveling feet of the unit. Refer to the installation illustration on page 4 for placement of the water line.
Do not route water supply line in front of the compressor tray. The tray must be slid forward for service.
Regardless of the routing, allow for 27" (686) of excess copper tubing to remain outside the wall or floor for easy connection to the unit, as shown in the installation illustration on
page 4.
A 115 volt, 6OHz, 15 amp circuit breaker and electrical supply are required. A separate circuit, servicing only this appliance is necessary.
All Integrated models are equipped with a power supply cord with a 3-prong grounding plug, which must be plugged into a mating 3-prong grounding type wall receptacle. The electrical outlet must be placed so the grounding prong is to the right of the thinner blades. The outlet must be flush with the back wall. Locate electrical within the shaded area shown in the installation illustration on page 4.
Do not use an extension cord or two prong adapter. Electrical ground is required.
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
The Integrated Refrigeration Installation Instructions packed with the appliance will give you step-by-step procedures for making sure the unit is installed properly.
millimeters unless otherwise specified. |
5 |