Wall Mounted Mini Split
Heat Pump
Air Conditioner
OPERATING AND INSTALLATION MANUAL
Model: KFHHP-18-ID / KFHHP-18-OD
Indoor Unit.
Outdoor Unit.
Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference.
TABLE OF CONTENTS
USE AND MAINTENANCE……………………………..…………………………………….....1-14 Precautions on Use …………………………………………………………………..……………1-3 Specifications and Technical Data…………………………………………………………………...4 Instructions of Use…………………………………………………….…………………….……….5 Description of Air Conditioner Components………………………………………………...………6 Remote Control Operation…………………………………………………………………………7-8 How to Insert Batteries…………………………………………………….…………………………9 Cleaning and Maintenance…………………………………………....……………...………….10-11 Trouble-Shooting…………………………………………………….…...………………..…….12-14
INSTALLATION SERVICES………………………………………………...………..…………15-21 Precautions of Installation…………………………………………………………....………….15-16 Indoor unit Selection of Installation Position………………………………….……………………15 Outdoor unit Selection of Installation Position………………………………...……...……………15 Electrical Safety Requirements………………………………………………………….………15-16 Grounding Requirement……………………………………………………………………….……16 Installation Dimension Drawing…………………………………………………………….…...…17 Install Indoor Unit……………………………………………………………………...………..18-19 Install Outdoor Unit…………………………………………………………………….……….20-21 Checks Items After Installation and Test Run…… ……………………………….....……………..21
ELECTRICAL SCHEMATIC DIAGRAM…………………………………...………..…………22-23
Electrical Schematic Diagram (Indoor Unit)…………………………...……………......………….22
Electrical Schematic Diagram (Outdoor Unit)………..……………………….……………………23
WARRANTY…………………………………………………………………………………………24
Danger Caution. |
This mark indicates a direction/procedure that |
|
must be followed! |
||
|
Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference.
Use and Maintenance
Precautions on Use
Carefully read the following precautions before use
Warning
In case of malfunction (e.g. burnt |
To avoid electric shock. Never |
Do not cut or use damaged power |
smell), cut off the power supply |
operate the unit with wet hands. |
cords and control lines. |
immediately and then contact the |
|
|
Authorized Service Center (626-820- |
|
|
1436). |
|
|
The malfunction continues, the air |
|
|
conditioner may be damaged. |
|
|
|
|
|
There is a possibility of electric |
Disconnect the power supply if |
Never use unapproved wire or |
shock or fire. To avoid electric shock |
you plan to discontinue using the unit |
controls. |
or fire, use an approved circuit. |
for the season. |
|
|
|
|
Please turn off the power before |
Rated voltage of this air |
This unit requires a circuit breaker |
cleaning the air conditioner. |
conditioner 208-230V~, with a |
as specified by your building code. |
|
tolerable fluctuation at 10%. Any |
|
|
other voltage will cause damage to |
|
|
the unit. |
|
cut off the |
|
|
power |
|
|
|
|
|
- 1 -
Precautions on Use
Grounding: The unit must be |
|
|
properly grounded. |
Set the room temperature appropriately. |
|
|
The difference |
|
|
between indoor |
|
|
and outdoor |
|
|
temperature |
|
|
shall be 40 °F. |
|
|
|
|
Close all doors & windows for |
Never block the air inlet or outlet |
To avoid the possibility of fire. |
efficient operation. |
of indoor and outdoor unit. |
Never store chemicals or flammable |
|
|
items within 3.28 feet of the unit. |
|
|
Otherwise it may cause fire or |
|
|
explosion. |
|
|
|
To avoid damage make sure the |
To avoid damage never place any |
Call an authorized service repair |
mounting of the unit is secure. |
object on the condensing unit. |
man if your unit malfunctions. |
|
|
|
- 2 -
Precautions on Use
Adjust the air flow and direction properly. When the air conditioner is running, you can press the SWING key on the remote control to adjust the guide louver and change the direction of air flow.
To avoid injury or damage, never stick your fingers or any other object into the unit.
To avoid harm to your pets or plants, never direct the airflow at them.
To avoid damage or electric shock, never spray liquid onto the unit.
To avoid carbon monoxide poisoning, never direct the airflow near or at your gas top burners.
To avoid any harm to your health, do not blow the cold air on your body for long periods or decrease the room temperature too low.
This air conditioner cannot be used for drying clothes or refrigerating foods.
- 3 -
Specifications and Technical Data
|
Model |
|
|
KFHHP-18-ID / KFHHP-18-OD |
|||
|
|
|
|
|
|
|
|
Function |
|
|
Heating and Cooling |
||||
|
|
|
|
|
|
|
|
Cooling capacity(BTU/hr) & (Watts) |
18000 / 5300 (1400-6000) |
||||||
|
|
|
|
|
|
|
|
Heating capacity(BTU/hr) & (Watts) |
20000 / 6000 (1100-7000) |
||||||
|
|
|
|
|
|
|
|
Rated voltage |
|
|
208-230V |
||||
|
|
|
|
|
|
|
|
Rated Frequency |
|
|
60Hz |
||||
|
|
|
|
|
|
|
|
Cooling/Heating rated current(A) |
10.6/10.6 |
|
|||||
|
|
|
|
|
|
|
|
Cooling/Heating rated power(W) |
2440/2440 |
|
|||||
|
|
|
|
|
|
|
|
Cooling/Heating power input(W) |
1350/1800 |
|
|||||
|
|
|
|
|
|
|
|
SEER |
|
13.25 |
|
||||
|
|
|
|
|
|
|
|
EER/COP(W/W) |
|
3.93/3.22 |
|
||||
|
|
|
|
|
|
|
|
HSPF |
|
8.5 |
|
||||
|
|
|
|
|
|
|
|
Recycling Air Volume m3/h |
800 |
|
|||||
Factory Charge 410A (lbs.)* |
|
|
R410A 3.9 lbs |
||||
|
|
|
|
|
|
|
|
Noise (Indoor/Outdoor) dBA |
|
50/57 |
|
||||
|
|
|
|
|
|
|
|
Height Differential |
Maximum Vertical |
|
16.4 ft |
||||
|
|
|
|
|
|
||
Maximum Length |
|
32.8 ft |
|||||
|
|
|
|||||
|
|
|
|
|
|
|
|
Net Weight (Indoor/Outdoor) (lb) |
28.7/130.1 |
|
|||||
|
|
|
|
|
|
||
Dimensions (Indoor/Outdoor) |
|
Indoor unit 40.16” × 8.98” ×12.20” |
|||||
(WxDxH)(inch) |
|
|
Outdoor unit 37.40” × 13.39” × 26.93” |
||||
Connection Pipe: |
|
|
|
|
|||
|
Length (ft) |
|
|
26.25 |
|
||
|
Gas additional charge(oz/ft) |
|
|
0.21 |
|
||
|
Outer Diameter |
|
Liquid Pipe (mm) |
|
Φ9.52(5/8”) |
|
|
|
|
Gas Pipe (mm) |
|
Φ16(3/8”) |
|
||
|
|
|
|
|
|
||
|
Max Distance |
|
Height (ft) |
|
26.25 |
|
|
|
|
Length (ft) |
|
49.21 |
|
||
|
|
|
|
|
|
|
All above are tested and certified to ETL specification. Among them, the cooling capacity, heating |
|||||
|
capacity and noise level are tested before shipment. |
|
|
|||
|
In case of any change in performance parameters, the data provided on nameplate shall prevail. |
|||||
|
Test the maximum input power under maximum cooling condition (89.6°F /73.4°F, 109.4°F /78.8°F) |
|||||
|
and maximum heating condition (44.6°F /-, 75.2°F /69.8°F). |
|||||
|
Working temperature range |
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
Indoor side DB/WB(°F) |
Outdoor side DB/WB(°F) |
|
|
|
|
|
|
|
|
|
|
Maximum cooling |
|
89.6 / 73.4 |
109.4 / 78.8(T1) |
|
|
|
Minimum cooling |
|
69.8 / 59 |
64.4 / - |
|
|
|
Maximum heating |
|
80.6 / - |
75.2 / 64.4 |
|
|
|
Minimum heating |
|
68 / - |
19.4 / 17.6 |
|
- 4 -
Instructions for Use
Principle and Special Functions during Cooling Mode
Principle:
The air conditioner absorbs heat from indoor air and transmits it outdoors for discharge, hence to decrease the indoor ambient temperature. The cooling capacity decreases with the rise of outdoor ambient temperature.
Anti-freeze Function:
If the air conditioner is running under low-temperature cooling mode, frost will appear on the surface of indoor heat exchanger. When the temperature of indoor heat exchanger is decreased to 32°F or below, the microcomputer of indoor unit will stop the compressor to protect the complete unit. A low ambient kit [not supplied] is required to make unit operate at lower than 32°F.
Principle and Special Functions under Heating Mode
Principle:
The air conditioner absorbs heat from outdoor air and transmits it indoors for emission, hence to increase the air temperature in the room. The heating capacity decreases with the reduction of the outdoor ambient temperature.
It takes only a short time for this type of hot air circulating system to increase the indoor temperature.
Use this air conditioner with other heating equipment if the outdoor temperature is extremely low.
Defrost:
When the outdoor temperature is low but the humidity is high, the heat exchanger of outdoor unit may freeze after the air conditioner has run for a period of time. This will decrease the heating effect. In this case, auto defrost function will be activated and the heating mode will temporarily stopped for 8-10 minutes.
Both the indoor fan and outdoor fan will be stopped during auto defrost.
During defrost, the indicator on indoor unit will blink and steam might flow from the indoor unit. This is caused by quick defrost other than fault.
Heating mode will automatically resume upon completion of defrost process.
Anti-freeze Function:
Under heating mode, if the indoor heat exchanger fails to reach a specific temperature under the following conditions, the indoor fan will not be started, so as to avoid blowing of cold air (within 3 minutes):
1. Start of heating mode. |
2. End of auto defrost. |
3. Heating under low-temperature environment. |
Conditions that the Air Conditioner will be unable to run normally:
The protection device will be activated within such temperature range as specified below, so that the unit will be shut down.
|
Outdoor temperature |
|
Outdoor temperature |
|
|
|
|
over 75.2°F |
|
|
Room |
||
Heating Mode |
Outdoor temperature |
Cooling |
over 109.4°F |
Dehumidify |
||
temperature |
||||||
below 19.4°F |
Mode |
|
Mode |
|||
|
|
below 64.4°F |
||||
|
Room temperature |
|
Room temperature |
|
||
|
|
|
|
|||
|
over 80.6°F |
|
below 69.8°F |
|
|
If the unit is run for extended periods under high humidify (80% +) condensation will be present at the outlets.
- 5 -
Description of Air-Conditioner Components
(1) Front Panel
(2) Guide Louver
(3) Remote Sensor
(4) Wall Pipe
(5) Wrapping Tape
(6) Drainage hose
(7) Connection pipe
- 6 -