Soleus Air KFHHP-18-ID, KFHHP-18-OD User Manual

4 (1)

Wall Mounted Mini Split

Heat Pump

Air Conditioner

OPERATING AND INSTALLATION MANUAL

Model: KFHHP-18-ID / KFHHP-18-OD

Indoor Unit.

Outdoor Unit.

Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference.

TABLE OF CONTENTS

USE AND MAINTENANCE……………………………..…………………………………….....1-14 Precautions on Use …………………………………………………………………..……………1-3 Specifications and Technical Data…………………………………………………………………...4 Instructions of Use…………………………………………………….…………………….……….5 Description of Air Conditioner Components………………………………………………...………6 Remote Control Operation…………………………………………………………………………7-8 How to Insert Batteries…………………………………………………….…………………………9 Cleaning and Maintenance…………………………………………....……………...………….10-11 Trouble-Shooting…………………………………………………….…...………………..…….12-14

INSTALLATION SERVICES………………………………………………...………..…………15-21 Precautions of Installation…………………………………………………………....………….15-16 Indoor unit Selection of Installation Position………………………………….……………………15 Outdoor unit Selection of Installation Position………………………………...……...……………15 Electrical Safety Requirements………………………………………………………….………15-16 Grounding Requirement……………………………………………………………………….……16 Installation Dimension Drawing…………………………………………………………….…...…17 Install Indoor Unit……………………………………………………………………...………..18-19 Install Outdoor Unit…………………………………………………………………….……….20-21 Checks Items After Installation and Test Run…… ……………………………….....……………..21

ELECTRICAL SCHEMATIC DIAGRAM…………………………………...………..…………22-23

Electrical Schematic Diagram (Indoor Unit)…………………………...……………......………….22

Electrical Schematic Diagram (Outdoor Unit)………..……………………….……………………23

WARRANTY…………………………………………………………………………………………24

Danger Caution.

This mark indicates a direction/procedure that

must be followed!

 

Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference.

Use and Maintenance

Precautions on Use

Carefully read the following precautions before use

Warning

In case of malfunction (e.g. burnt

To avoid electric shock. Never

Do not cut or use damaged power

smell), cut off the power supply

operate the unit with wet hands.

cords and control lines.

immediately and then contact the

 

 

Authorized Service Center (626-820-

 

 

1436).

 

 

The malfunction continues, the air

 

 

conditioner may be damaged.

 

 

 

 

 

There is a possibility of electric

Disconnect the power supply if

Never use unapproved wire or

shock or fire. To avoid electric shock

you plan to discontinue using the unit

controls.

or fire, use an approved circuit.

for the season.

 

 

 

 

Please turn off the power before

Rated voltage of this air

This unit requires a circuit breaker

cleaning the air conditioner.

conditioner 208-230V~, with a

as specified by your building code.

 

tolerable fluctuation at 10%. Any

 

 

other voltage will cause damage to

 

 

the unit.

 

cut off the

 

 

power

 

 

 

 

 

- 1 -

Precautions on Use

Grounding: The unit must be

 

 

properly grounded.

Set the room temperature appropriately.

 

The difference

 

 

between indoor

 

 

and outdoor

 

 

temperature

 

 

shall be 40 °F.

 

 

 

 

Close all doors & windows for

Never block the air inlet or outlet

To avoid the possibility of fire.

efficient operation.

of indoor and outdoor unit.

Never store chemicals or flammable

 

 

items within 3.28 feet of the unit.

 

 

Otherwise it may cause fire or

 

 

explosion.

 

 

 

To avoid damage make sure the

To avoid damage never place any

Call an authorized service repair

mounting of the unit is secure.

object on the condensing unit.

man if your unit malfunctions.

 

 

 

- 2 -

Precautions on Use

Adjust the air flow and direction properly. When the air conditioner is running, you can press the SWING key on the remote control to adjust the guide louver and change the direction of air flow.

To avoid injury or damage, never stick your fingers or any other object into the unit.

To avoid harm to your pets or plants, never direct the airflow at them.

To avoid damage or electric shock, never spray liquid onto the unit.

To avoid carbon monoxide poisoning, never direct the airflow near or at your gas top burners.

To avoid any harm to your health, do not blow the cold air on your body for long periods or decrease the room temperature too low.

This air conditioner cannot be used for drying clothes or refrigerating foods.

- 3 -

Specifications and Technical Data

 

Model

 

 

KFHHP-18-ID / KFHHP-18-OD

 

 

 

 

 

 

 

 

Function

 

 

Heating and Cooling

 

 

 

 

 

 

 

Cooling capacity(BTU/hr) & (Watts)

18000 / 5300 (1400-6000)

 

 

 

 

 

 

 

Heating capacity(BTU/hr) & (Watts)

20000 / 6000 (1100-7000)

 

 

 

 

 

 

 

 

Rated voltage

 

 

208-230V

 

 

 

 

 

 

 

 

Rated Frequency

 

 

60Hz

 

 

 

 

 

 

 

Cooling/Heating rated current(A)

10.6/10.6

 

 

 

 

 

 

 

 

Cooling/Heating rated power(W)

2440/2440

 

 

 

 

 

 

 

 

Cooling/Heating power input(W)

1350/1800

 

 

 

 

 

 

 

 

 

SEER

 

13.25

 

 

 

 

 

 

 

 

 

EER/COP(W/W)

 

3.93/3.22

 

 

 

 

 

 

 

 

 

HSPF

 

8.5

 

 

 

 

 

 

 

 

Recycling Air Volume m3/h

800

 

Factory Charge 410A (lbs.)*

 

 

R410A 3.9 lbs

 

 

 

 

 

 

 

 

Noise (Indoor/Outdoor) dBA

 

50/57

 

 

 

 

 

 

 

 

Height Differential

Maximum Vertical

 

16.4 ft

 

 

 

 

 

 

Maximum Length

 

32.8 ft

 

 

 

 

 

 

 

 

 

 

Net Weight (Indoor/Outdoor) (lb)

28.7/130.1

 

 

 

 

 

 

 

Dimensions (Indoor/Outdoor)

 

Indoor unit 40.16” × 8.98” ×12.20”

(WxDxH)(inch)

 

 

Outdoor unit 37.40” × 13.39” × 26.93”

Connection Pipe:

 

 

 

 

 

Length (ft)

 

 

26.25

 

 

Gas additional charge(oz/ft)

 

 

0.21

 

 

Outer Diameter

 

Liquid Pipe (mm)

 

Φ9.52(5/8”)

 

 

 

Gas Pipe (mm)

 

Φ16(3/8”)

 

 

 

 

 

 

 

 

Max Distance

 

Height (ft)

 

26.25

 

 

 

Length (ft)

 

49.21

 

 

 

 

 

 

 

 

All above are tested and certified to ETL specification. Among them, the cooling capacity, heating

 

capacity and noise level are tested before shipment.

 

 

 

In case of any change in performance parameters, the data provided on nameplate shall prevail.

 

Test the maximum input power under maximum cooling condition (89.6°F /73.4°F, 109.4°F /78.8°F)

 

and maximum heating condition (44.6°F /-, 75.2°F /69.8°F).

 

Working temperature range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor side DB/WB(°F)

Outdoor side DB/WB(°F)

 

 

 

 

 

 

 

 

 

 

Maximum cooling

 

89.6 / 73.4

109.4 / 78.8(T1)

 

 

 

Minimum cooling

 

69.8 / 59

64.4 / -

 

 

 

Maximum heating

 

80.6 / -

75.2 / 64.4

 

 

 

Minimum heating

 

68 / -

19.4 / 17.6

 

- 4 -

Instructions for Use

Principle and Special Functions during Cooling Mode

Principle:

The air conditioner absorbs heat from indoor air and transmits it outdoors for discharge, hence to decrease the indoor ambient temperature. The cooling capacity decreases with the rise of outdoor ambient temperature.

Anti-freeze Function:

If the air conditioner is running under low-temperature cooling mode, frost will appear on the surface of indoor heat exchanger. When the temperature of indoor heat exchanger is decreased to 32°F or below, the microcomputer of indoor unit will stop the compressor to protect the complete unit. A low ambient kit [not supplied] is required to make unit operate at lower than 32°F.

Principle and Special Functions under Heating Mode

Principle:

The air conditioner absorbs heat from outdoor air and transmits it indoors for emission, hence to increase the air temperature in the room. The heating capacity decreases with the reduction of the outdoor ambient temperature.

It takes only a short time for this type of hot air circulating system to increase the indoor temperature.

Use this air conditioner with other heating equipment if the outdoor temperature is extremely low.

Defrost:

When the outdoor temperature is low but the humidity is high, the heat exchanger of outdoor unit may freeze after the air conditioner has run for a period of time. This will decrease the heating effect. In this case, auto defrost function will be activated and the heating mode will temporarily stopped for 8-10 minutes.

Both the indoor fan and outdoor fan will be stopped during auto defrost.

During defrost, the indicator on indoor unit will blink and steam might flow from the indoor unit. This is caused by quick defrost other than fault.

Heating mode will automatically resume upon completion of defrost process.

Anti-freeze Function:

Under heating mode, if the indoor heat exchanger fails to reach a specific temperature under the following conditions, the indoor fan will not be started, so as to avoid blowing of cold air (within 3 minutes):

1. Start of heating mode.

2. End of auto defrost.

3. Heating under low-temperature environment.

Conditions that the Air Conditioner will be unable to run normally:

The protection device will be activated within such temperature range as specified below, so that the unit will be shut down.

 

Outdoor temperature

 

Outdoor temperature

 

 

 

over 75.2°F

 

 

Room

Heating Mode

Outdoor temperature

Cooling

over 109.4°F

Dehumidify

temperature

below 19.4°F

Mode

 

Mode

 

 

below 64.4°F

 

Room temperature

 

Room temperature

 

 

 

 

 

 

over 80.6°F

 

below 69.8°F

 

 

If the unit is run for extended periods under high humidify (80% +) condensation will be present at the outlets.

- 5 -

Soleus Air KFHHP-18-ID, KFHHP-18-OD User Manual

Description of Air-Conditioner Components

(1) Front Panel

(2) Guide Louver

(3) Remote Sensor

(4) Wall Pipe

(5) Wrapping Tape

(6) Drainage hose

(7) Connection pipe

- 6 -