Power Optimiser
For Australia
P605 / P730 / P801 / P850 / P800p / P950 / P1100
25
YEAR
WARRANTY
POWER OPTIMISER
PV power optimisation at the module-level
The most cost eective solution for commercial and large eld installations
Specically designed to work with SolarEdge
inverters
Up to 25% more energy
Superior efciency (99.5%)
Balance of System cost reduction; 50% less
cables, fuses and combiner boxes, over 2x longer
string lengths possible
solaredge.com
Fast installation with a single bolt
Advanced maintenance with module-level
monitoring
Module-level voltage shutdown for installer
and reghter safety
Use with two PV modules connected in series
or in parallel

Power Optimiser
For Australia
P605 / P730 / P801 / P850 / P800p / P950 / P1100
Optimiser Model
(Typical Module
Compatibility)
P605
(for 1
x high
power PV
module)
P730
(for up
to 2 x
72-cell PV
modules)
P801
(for up
to 2x72-
cell PV
modules)
P850
(for up to 2x
high power
or bi-facial
modules)
P800p
(for up to
2x 96-cell
5’’ PV
modules)
P950
(for up to 2x
high power
or bi- facial
modules)
P1100
(for up to 2x
high power
or bi- facial
modules)
INPUT
Rated Input DC Power
Connection Method Single input for series connected modules
Absolute Maximum Input Voltage
(Voc at lowe temperature)
MPPT Operating Range 12.5 - 65 12.5 - 105 12.5 - 83 12.5 - 105 Vdc
Maximum Short Circuit Current
per Input (Isc)
Maximum Eciency 99.5 %
Weighted Eciency 98.6 %
Overvoltage Category II
OUTPUT DURING OPERATION (POWER OPTIMISER CONNECTED TO OPERATING SOLAREDGE INVERTER
Maximum Output Current 15 18 Adc
Maximum Output Voltage 80 Vdc
OUTPUT DURING STANDBY (POWER OPTIMISER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF
Safety Output Voltage per Power
Optimiser
(1)
605 730 800 850 800 950 1100 W
Dual input for
independently
connected
65 125 83 125 Vdc
14 11 11.75 12.5 7 12.5 14 Adc
(7)
Single input for series connected
modules
)
)
1 ± 0.1 Vdc
STANDARD COMPLIANCE
EMC FCC Part15 Class A, IEC61000-6-2, IEC61000-6-3
Safety IEC62109-1 (class II safety)
RoHS Yes
Fire Safety VDE-AR-E 2100-712:2013-05
INSTALLATION SPECIFICATIONS
Compatible SolarEdge Inverters Three phase inverters SE15K & larger
Maximum Allowed Syem Voltage 1000 Vdc
Dimensions (W x L x H) 129 x 153 x 52 129 x 153 x 49.5 129 x 162 x 59 129 x 168 x 59 129 x 162 x 59 129 x 168 x 59 mm
Weight (including cables) 1064 933 1064 gr
Input Connector MC4
Output Connector MC4
Output Wire Length 1.4 2.2 2.4 m
Input Wire Length 0.16 0.16, 0.9
Operating Temperature Range
Protection Rating IP68 / NEMA6P
Relative Humidity 0 - 100 %
(1) Rated power of the module at STC will not exceed the optimiser “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed
(2) For other connector types please contact SolarEdge
(3) Longer inputs wire length are available for use with split junction box modules. (For 0.9m/0.52ft order P730/P801/ P850-xxxLxxx. For 1.3m/4.26ft order P850/P950/P1100 -xxxXxxx. For 1.6m/5.24ft order P850/P950-xxxYxxx)
(4) For ambient temperature above +70˚C power de-rating is applied. Refer to https://www.solaredge.com/sites/default/les/se-temperature-derating-note.pdf for more details
(4)
(3)
0.16, 0.9, 1.3, 1.6
(2)
(3)
-40 to +85 ˚C
0.16 0.16, 1.3, 1.6
(3)
Three phase
inverters SE25K &
larger
(3)
0.16, 1.3
m

Power Optimiser
For Australia
P605 / P730 / P801 / P850 / P800p / P950 / P1100
PV System Design Using a Solaredge
Inverter
Compatible Power Optimisers P605 P730 P801 P850 P800p P950 P1100 P605 P730 P801 P850 P800p P950 P1100
Minimum String Length
Maximum String Length
Maximum Nominal Power per String 11250
Parallel Strings of Dierent Lengths or Orientations Ye s
(5) P730/P801 can be mixed in one ring, and P850/P800p/P950/P1100 can also be mixed in one ring. It is not allowed to mix P730/P801 with P850/P800p/P950/P1100,nor is it allowed to mix P730-P1100 with
P370-P505 in one ring. P605 cannot be mixed with any other power optimizer in the same ring
(6) For SE15K and above, the minimum DC power should be 11KW
(7) In a case of odd number of PV modules in one ring it is allowed to inall one P730/P850/P800p/P801/P950/P1100 power optimiser connected to one PV module. When connecting a single module to the
P800p seal the unused input connectors with the supplied pair of seals
(8) Power optimisers intended for use with two PV modules each (2:1 connection), can be used with a single PV module (1:1 connection), as long as the entire ring uses 1:1 connections
(9) For the 230/400V grid: With P605/P730/P801 up to 13,500W per ring may be inalled, with P850/P800p up to 15,750W and with P950/P1100 up to 18,500W per ring may be inalled when the maximum
power dierence between each ring is 2,000W. For P950, minimum two rings are required for SE15K-SE27.6K inverters. For P1100, minimum two rings are required for SE25K-SE27.6K inverters. For P950/
P1100 with SE30K and above minimum three rings are required
(10) For the 277/480V grid: With P605/P730/P801 up to 15,000W per ring may be inalled, with P850/P800p up to 17,550W and with P950/P1100 up to 20,300W per ring may be inalled when the maximum
power dierence between each ring is 2,000W.For P950/P1100, minimum three rings are required for SE33.3K and SE40K inverters
(5)(6)(7)(8)
Power Optimisers 14
PV Modules 14 27 14 27
Power Optimisers 30
PV Modules 30 60 30 60
Three Phase for 230/400V Grid Three Phase for 277/480V Grid
(9)
13500
(9)
12750
(10)
15300
(10)
W
© SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Ltd.