SMC Networks Networks Switch SMC8848M User Manual

Size:
8.2 Mb
Download

TigerStack II

10/100/1000

Gigabit Ethernet Switch

24/48 auto-MDI/MDI-X10/100/1000BASE-Tports

4 RJ-45ports shared with 4 SFP transceiver slots

2 10GBASE extender module slots

Non-blockingswitching architecture

Support for a redundant power unit

Spanning Tree Protocol, RSTP, and MSTP

Up to 32 LACP or static 8-porttrunks

Layer 2/3/4 CoS support through eight priority queues

Layer 3/4 traffic priority with IP Precedence and IP DSCP

Full support for VLANs with GVRP

IGMP multicast filtering and snooping

Manageable via console, Web, SNMP/RMON

Security features: ACL, RADIUS, 802.1x

Supports IPv4/IPv6, dual protocol stack

Installation Guide

SMC8824M

SMC8848M

TigerStack II 10/100/1000

Installation Guide

From SMC’s Tiger line of feature-richworkgroup LAN solutions

38 Tesla

 

Irvine, CA 92618

February 2006

Phone: (949) 679-8000

Pub. # 150200054300A

Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and reliable. However, no responsibility is assumed by SMC for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SMC. SMC reserves the right to change specifications at any time without notice.

Copyright © 2006 by SMC Networks, Inc.

38 Tesla

Irvine, CA 92618

All rights reserved. Printed in Taiwan

Trademarks:

SMC is a registered trademark; and EZ Switch, TigerStack and TigerSwitch are trademarks of SMC Networks, Inc. Other product and company names are trademarks or registered trademarks of their respective holders.

LIMITEDWARRANTY

Limited Warranty Statement: SMC Networks, Inc. (“SMC”) warrants its products to be free from defects in workmanship and materials, under normal use and service, for the applicable warranty term. All SMC products carry a standard90-daylimited warranty from the date of purchase from SMC or its Authorized Reseller. SMC may, at its own discretion, repair or replace any product not operating as warranted with a similar or functionally equivalent product, during the applicable warranty term. SMC will endeavor to repair or replace any product returned under warranty within 30 days of receipt of the product.

The standard limited warranty can be upgraded to a Limited Lifetime* warranty by registering new products within 30 days of purchase from SMC or its Authorized Reseller. Registration can be accomplished via the enclosed product registration card or online via the SMC Web site. Failure to register will not affect the standard limited warranty. The Limited Lifetime warranty covers a product during the Life of that Product, which is defined as the period of time during which the product is an “Active” SMC product. A product is considered to be “Active” while it is listed on the current SMC price list. As new technologies emerge, older technologies become obsolete and SMC will, at its discretion, replace an older product in its product line with one that incorporates these newer technologies. At that point, the obsolete product is discontinued and is no longer an “Active” SMC product. A list of discontinued products with their respective dates of discontinuance can be found at: http://www.smc.com/index.cfm?action=customer_service_warranty.

All products that are replaced become the property of SMC. Replacement products may be either new or reconditioned. Any replaced or repaired product carries either a 30-daylimited warranty or the remainder of the initial warranty, whichever is longer. SMC is not responsible for any custom software or firmware, configuration information, or memory data of Customer contained in, stored on, or integrated with any products returned to SMC pursuant to any warranty. Products returned to SMC should have anycustomer-installedaccessory oradd-oncomponents, such as expansion modules, removed prior to returning the product for replacement. SMC is not responsible for these items if they are returned with the product.

Customers must contact SMC for a Return Material Authorization number prior to returning any product to SMC. Proof of purchase may be required. Any product returned to SMC without a valid Return Material Authorization (RMA) number clearly marked on the outside of the package will be returned to customer at customer’s expense. For warranty claims within North America, please call our toll-freecustomer support number at (800)762-4968.Customers are responsible for all shipping charges from their facility to SMC. SMC is responsible for return shipping charges from SMC to customer.

i

WARRANTIES EXCLUSIVE: IF AN SMC PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY SHALL BE REPAIR OR REPLACEMENT OF THE PRODUCT IN QUESTION, AT SMC’S OPTION. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. SMC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS. SMC SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER’S OR ANY THIRD PERSON’S MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING, OR OTHER HAZARD.

LIMITATION OF LIABILITY: IN NO EVENT, WHETHER BASED IN CONTRACT OR TORT (INCLUDING NEGLIGENCE), SHALL SMC BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE, LOSS OF BUSINESS, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE, PERFORMANCE, FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF SMC OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR THE LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS, SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, WHICH MAY VARY FROM STATE TO STATE. NOTHING IN THIS WARRANTY SHALL BE TAKEN TO AFFECT YOUR STATUTORY RIGHTS.

* SMC will provide warranty service for one year following discontinuance from the active SMC price list. Under the limited lifetime warranty, internal and external power supplies, fans, and cables are covered by a standard one-yearwarranty from date of purchase.

SMC Networks, Inc.

38 Tesla

Irvine, CA 92618

ii

COMPLIANCES

FCC - Class A

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.

You may use unshielded twisted-pair(UTP) forRJ-45connections - Category 3 or better for 10 Mbps connections, Category 5 or better for 100 Mbps connections, Category 5, 5e, or 6 for 1000 Mbps connections. For fiber optic connections, you may use 50/125 or 62.5/125 micron multimode fiber or 9/125 micronsingle-modefiber.

Industry Canada - Class A

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference-causingequipment standard entitled “Digital Apparatus,”ICES-003of the Department of Communications.

Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: “Appareils Numériques,” NMB-003édictée par le ministère des Communications.

Japan VCCI Class A

iii

COMPLIANCES

CE Mark Declaration of Conformance for EMI and Safety (EEC)

SMC contact for these products in Europe is:

SMC Networks Europe, Edificio Conata II,

Calle Fructuós Gelabert 6-8,2o, 4a,

08970 - Sant Joan Despí, Barcelona, Spain.

This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the compliance with these Directives, the following standards were applied:

RFI Emission:

• Limit class A according to EN 55022:1998

 

• Limit class A for harmonic current emission according to

 

EN 61000-3-2/1995

 

• Limitation of voltage fluctuation and flicker in low-voltagesupply

 

system according to EN 61000-3-3/1995

Immunity:

• Product family standard according to EN 55024:1998

 

• Electrostatic Discharge according to EN 61000-4-2:1995

 

(Contact Discharge: ±4 kV, Air Discharge: ±8 kV)

 

Radio-frequencyelectromagnetic field according to EN61000-4-3:1996

 

(80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)

 

• Electrical fast transient/burst according to EN 61000-4-4:1995(AC/

 

DC power supply: ±1 kV, Data/Signal lines: ±0.5 kV)

 

• Surge immunity test according to EN 61000-4-5:1995

 

(AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV)

 

• Immunity to conducted disturbances, Induced by radio-frequency

 

fields: EN 61000-4-6:1996(0.15 - 80 MHz with

 

1 kHz AM 80% Modulation: 3 V/m)

 

• Power frequency magnetic field immunity test according to

 

EN 61000-4-8:1993(1 A/m at frequency 50 Hz)

 

• Voltage dips, short interruptions and voltage variations immunity test

 

according to EN 61000-4-11:1994(>95% Reduction @10 ms, 30%

 

Reduction @500 ms, >95% Reduction @5000 ms)

LVD:

• EN 60950-1:2001

Warning: Do not plug a phone jack connector in theRJ-45port. This may damage this device.Attention: Les raccordeurs ne sont pas utilisés pour le système téléphonique!

iv

COMPLIANCES

Australia AS/NZS 3548 (1995) - Class A

N11846

SMC contact for products in Australia is:

SMC Communications Pty. Ltd.

Suite 18, 12 Tryon Road,

Lindfield NSW2070,

Phone: 61-2-94160437

Fax: 61-2-94160474

Safety Compliance

Warning: Fiber Optic Port Safety

CLASS I

When using a fiber optic port, never look at the transmit laser while

it is powered on. Also, never look directly at the fiber TX port and

LASER DEVICE

fiber cable ends when they are powered on.

 

Avertissment: Ports pour fibres optiques - sécurité sur le plan optique

Ne regardez jamais le laser tant qu’il est sous tension. Ne regardez

DISPOSITIF LASER jamais directement le port TX (Transmission) à fibres optiques et les

DE CLASSE I

embouts de câbles à fibres optiques tant qu’ils sont sous tension.

Warnhinweis: Faseroptikanschlüsse - Optische Sicherheit

Niemals ein Übertragungslaser betrachten, während dieses

LASERGERÄT eingeschaltet ist. Niemals direkt auf denFaser-TX-Anschlußund auf

DER KLASSE I

die Faserkabelenden schauen, während diese eingeschaltet sind.

Power Cord Safety

Please read the following safety information carefully before installing the switch:

Warning: Installation and removal of the unit must be carried out by qualified personnel only.

The unit must be connected to an earthed (grounded) outlet to comply with international safety standards.

Do not connect the unit to an A.C. outlet (power supply) without an earth (ground) connection.

The appliance coupler (the connector to the unit and not the wall plug) must have a configuration for mating with an EN 60320/IEC 320 appliance inlet.

The socket outlet must be near to the unit and easily accessible. You can only remove power from the unit by disconnecting the power cord from the outlet.

v

COMPLIANCES

This unit operates under SELV (Safety Extra Low Voltage) conditions according to

IEC 60950. The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions.

France and Peru only

This unit cannot be powered from ITsupplies. If your supplies are of IT type, this unit must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point labelled Neutral, connected directly to earth (ground).

Impédance à la terre

Important! Before making connections, make sure you have the correct cord set. Check it (read the label on the cable) against the following:

Power Cord Set

U.S.A. and Canada

The cord set must be UL-approvedand CSA certified.

 

 

 

The minimum specifications for the flexible cord are:

 

- No. 18 AWG - not longer than 2 meters, or 16 AWG.

 

- Type SV or SJ

 

- 3-conductor

 

 

 

The cord set must have a rated current capacity of at least 10 A

 

 

 

The attachment plug must be an earth-groundingtype with NEMA

 

5-15P(15 A, 125 V) or NEMA6-15P(15 A, 250 V) configuration.

 

 

Denmark

The supply plug must comply with Section 107-2-D1,Standard

 

DK2-1aorDK2-5a.

 

 

Switzerland

The supply plug must comply with SEV/ASE 1011.

 

 

U.K.

The supply plug must comply with BS1363 (3-pin13 A) and be

 

fitted with a 5 A fuse which complies with BS1362.

 

 

 

The mains cord must be <HAR> or <BASEC> marked and be of

 

type HO3VVF3GO.75 (minimum).

 

 

Europe

The supply plug must comply with CEE7/7 (“SCHUKO”).

 

 

 

The mains cord must be <HAR> or <BASEC> marked and be of

 

type HO3VVF3GO.75 (minimum).

 

 

 

IEC-320receptacle.

 

 

vi