NO. 528 Fushing 3rd, Hwa-Ya tech. Park
Kueishan, Tao Yuan 333, Taiwan
FACTORY NAME
SENAO NETWORKS
FACTORY ADDRESS
NO. 528 Fushing 3rd, Hwa-Ya tech. Park
Kueishan, Tao Yuan 333, Taiwan
VERSION
2.0
Sify Technologies LTD Page 2
User Operating Manual
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
Operations in the 5.15-5.25GHz band are restricted to indoor usage only.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
Sify Technologies LTD Page 3
Professional installation instruction
1. Installation personal
This product is designed for specific application and needs to be installed by a
qualified personal who has RF and related rule knowledge. The general user shall
not attempt to install or change the setting.
2. Installation location
The product shall be installed at a location where the radiating antenna can be
kept 20cm from nearby person in normal operation condition to meet regulatory RF
exposure requirement.
User Operating Manual
3. External antenna
Use only the antennas which have been approved by the applicant.The nonapproved antenna(s) may produce unwanted spurious or excessive RF transmitting
power which may lead to the violation of FCC limit and is prohibited.
4. Installation procedure
Please refer to user’s manual for the detail.
5. Warning
Please carefully select the installation position and make sure that the final output
power does not exceed the limit set force in relevant rules. The violation of the
rule could lead to serious federal penalty.
1.4 Status .......................................................................................................................................... 13
1.4.2 Main ..................................................................................................................................... 14
1.4.3 Wireless Client List ............................................................................................................... 14
1.4.4 System Log ........................................................................................................................... 15
1.4.5 Connection Status ................................................................................................................ 15
1.5 System ......................................................................................................................................... 16
1.9 LED Indication ............................................................................................................................. 32
Sify Technologies LTD Page 6
User Operating Manual
Safety precautions:
Prior to connecting cables to the ODU, the protective earth terminal (screw) of the ODU must
be connected to an external protective ground conductor or to a grounded mast.
Only a qualified person using the proper safety equipment should climb the antenna mast.
Only trained professional installers should be used when installing or dismantling ODUs and
masts.
Do not use product near water (i.e. wet basement, bathtub, sink or near a swimming pool,
etc.), to avoid risk of electrocution
Avoid using and/or connecting the equipment during an electrical storm, to avoid risk of
electrocution.
Sify Technologies LTD Page 7
1.1 ODU
Description
User Operating Manual
Figure 1: Radio (SMAC5700)
Thank you for using SMAC5700. It is a powerful, enhanced, enterprise scale product with
functions Outdoor Base and Outdoor Subscriber.
SMAC5700 uses the latest wireless technology 802.11n standard. It has faster
transmit/receive wireless speed. SMAC5700 gives you a great advantage to save your time
and cost to expend your network. It is also compatible with 802.11a.
Sify Technologies LTD Page 8
User Operating Manual
PRODUCT MODELS
SMAC5700
SKU : APX-57200D
SMAC 5700 Base station unit, 200 Mbps, 5.8 GHz, 2 x N-Type
connectors
INTERFACES
WIRED
ETHERNET
Single auto MDI-X RJ45 10/100/1000 Mbps with POE & Data
WIRELESS
INTERFACE
802.11 a/n
RADIO SPECS
RANGE
Upto 20 Km / 12 miles
MIMO
2x2 MIMO
MODULATION
OFDM
FREQUENCY
BAND
5.725 GHz- 5.850 GHz
CHANNEL
BANDWIDTH
Configurable : 20 MHz, 40 MHz
DUPLEX
TECHNOLOGY
TDD
DATA RATE
MCS 0 to 15 for max throughput (6.5 – 300 Mbps) with DDRS
BPSK, QPSK, 16-QAM and 64-QAM for (6 Mbps – 54 Mbps) –
legacy mode
ADAPTIVE
MODULATION &
CODING
Supported
TX POWER
Up to 24dBm
TX POWER
CONTROL
Transmit power control and distance control (ACK timeout)
RX SENSITIVITY
(BER=10-6)
(in dBm)
Channel Size
20 MHz
MCS0 / MCS8
-90 MCS1 / MCS9
-87 MCS2 / MCS10
-85 MCS3 / MCS11
-80
MCS4 / MCS12
-77 MCS5 / MCS13
-73
SMAC5700 is easily to install almost anywhere with Power over Ethernet for quick indoor
installation and regular Power by Adapter. SMAC5700 can manage power level control,
Narrow bandwidth selection, Traffic shaping and Real-time RSSI indicator. SMAC5700 is
fully support of security encryption including Wi-Fi Protected Access (WPA2-PSK), 128 bit
- AES Encryption and IEEE 802.1x with RADIUS.
Technical Specification
Sify Technologies LTD Page 9
User Operating Manual
MCS6 / MCS14
-71
MCS7 / MCS15
-70
LED INDICATION
Ethernet status and wireless signal strength indication
LATENCY
< 10 m.sec (typical)
ANTENNA
APX-57200-D
TYPE
External
CONNECTOR
2 x N-Type connector with built in Surge
Protection
MANAGEMENT
LOCAL
Serial interface RS-232 available in PCBA
REMOTE
Telnet and SSH, Web/GUI, TFTP, SNMP V2
SNMP
SNMP V1,V2c, V3, Traps, Private MIB
OTHER
Syslog
BACKUP
User can backup all settings to a file via WEB & CLI
PING &
TRACEROUTE
Built in functionality from Web GUI
FIRMWARE
UPGRADE
Upgrading firmware via web browser & CLI, settings are reserved
after upgrade
SECURITY
ENCRYPTION
AES-128 bit
AUTHENTICATION
802.1X, MAC address, Radius based Authentication
NETWORK
BRIDGING
Transparent Bridging (802.1d)
ROUTING
Static and Dynamic Routing, RIP v1/v2
IP
Ipv4 Static and Dynamic address,IPV6
GATEWAY
FEATURES
DHCP Server, DHCP Client, Filter
VLAN
802.1Q – Access VLAN, Trunk and Q-in-Q
FEATURES
FILTERING
IP source / destination address , TCP/UDP Port Numbers, MAC
address Source or Destination, Multicast traffic, Broadcast
BANDWIDTH
CONTROL
Flexible uplink and downlink bandwidth control
POWER
POE (Power Over
Ethernet )
Power adapter Input – 100-240V/ 0.6A ,50 to 60Hz
Power adapter Output – 48VDC /0.5A
Sify Technologies LTD Page 10
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.