Siemens CP 343-1 User Manual

5 (1)

SIMATIC NET

Produktinformation

C79000–Z8964–C038–05

Product Information

 

Information produit

 

Informazioni sul prodotto

Información sobre producto

 

Stand/ Dated/ Edition/ Versione/ Versiòn 06/99

CP 343–1

6GK7 343-1BA00-0XE0

 

ab Ausgabestand 7 (FW–Stand V5.00)

 

version 7 or higher (firmware V5.00)

 

à partir de la version 7 (microprogramme V5.00)

 

a partire dalla versione 7 (versione FW V4.00)

 

a partir de la versión 7 (FW-V5.00)

SIMATIC S7–300

Deutsch / English / Français / Italiano / Español

ESIEMENS AG 1998 Änderungen vorbehalten Subject to alteration

Sous réserve de modifications Con riserva di modifiche Sujeto a cambios

Hinweis / Note / Avertissement / Avvertenza / Indicación

Achtung

Vorder Inbetriebnahme Hinweise in der entsprechenden aktuellen Dokumentation beachten. Die Bestelldaten hierfür entnehmen Sie bitte den Katalogen oder wenden Sie sich an Ihre örtliche SIEMENS#Niederlassung.

Die Inbetriebnahme ist solange untersagt, bis festgestellt wurde, daß die Maschine, in die diese Komponente eingebaut werden soll, den Bestimmungen der Richtlinie 89/392/EWG entspricht.

Attention

Priorto startup you must observe the notes in the relevant documentation. For ordering data of the documenta# tion please refer to catologs or contact your local SIEMENS representative.

Startupmust not take place until it is established that the machine, which is to accommodate this component, is in conformity the guideline 89/392/EEC.

Attention

Avant la mise en service, respecter les instructions de la documentation actuelle correspondante. Pour les références de commande de la documentation, veuillez#vous reporter aux catalogues ou consulter votre agence locale SIEMENS.

La mise en service est interdite tant que la machine dans laquelle est incorporé ce composant n'est pas con# forme aux prescriptions de la directive 89/392/CEE.

Attenzione

Prima della messa in funzione, osservare attentamente le avvertenze riportate nella documentazione corrente. Per i dati di ordinazione consultare i cataloghi oppure rivolgersi alla locale fidale SIEMENS.

La messa in funzione è vietata fino a quando non è stato acctertato che macchina, in cui il componente deve essere installato, non rispetta le disposizioni della direttiva 89/392/CCE.

Atención

Antes de la puesta en marcha observar las indicaciones contenidas en la documentatción actual correspon# diente.La referencia de la misma puede consultarse en los catáloges o solicitarse a su agencia SIEMENSlocal.

Está prohibida la puesta en marcha hasta comprobar que la máquina en donde va a incorporarse este compo# nente cumple lo especificado en la directiva 89/392/CCE.

 

 

english

Contents

 

Notes for the Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

1

The CP 343-1 Communications Processor . . . . . . . . . . . . . . .

3

1.1

Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

1.2

Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

1.2.1

Characteristics of S7 Communication . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

1.2.2

Characteristics of ISO Transport Connections . . . . . . . . . . . . . . . . . . .

7

1.3

Displays and Mode Selector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

1.4

Further Information on Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

2

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

2.1

Module Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

2.2

Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

2.3

Attaching the CP 343-1 to Industrial Ethernet . . . . . . . . . . . . . . . . . . . .

13

3

Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

3.1

General Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

3.2

Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16

3.3

Notes on the CE Approval of SIMATIC NET Products . . . . . . . . . . . . .

17

4

References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18

Compatibility with the Previous Version

The version of the CP 343-1 described here is functionally compatible with and can be used to replace the CP 343-1 with order number 6GK7 343–1BA00–0XE0 version 6.

The CP 343-1 decribed here has more functions. Refer to the information in Section 1.1.

Reply Form (at the end of this product information):

We would like to know the purpose for which you are using this module and would also like to know your opinion of the module and the documentation. You can help us to provide you with better support and to further improve the product. We would be grateful if you would complete the reply form and return it to us by post or fax.

Product information CP 343–1

1

C79000–Z8964–C038–05

 

english

Notes for the Reader

Safety Guidelines

This manual contains notices which you should observe to ensure your own personal safety, as well as to protect the product and connected equipment. These notices are highlighted in the manual by a warning triangle and are marked as follows according to the level of danger:

Note

draws your attention to particularly important information on the product, handling the product, or to a particular part of the documentation.

Caution

!indicates that minor personal injury or property damage can result if proper precautions are not taken.

Warning

!indicates that death, severe personal injury or substantial property damage can result if proper precautions are not taken.

Danger

!indicates that death, severe personal injury or substantial property damage will result if proper precautions are not taken.

Copyright E Siemens AG 1998..1999 All rights reserved

Disclaimer of Liability

The reproduction, transmission or use of this document or its contents is not permitted without express written authority.

Offenders will be liable for damages. All rights, including rights createdby patent grant or registration of a utility model or design, are reserved.

Siemens AG

A&D

Industrial Automation Systems

Postfach 4848, D-90327Nürnberg

2

We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvementare welcomed.

Technical data subject to change.

Product information CP 343–1

C79000–Z8964–C038–05

english

1 The CP 343-1 Communications Processor

Application

The CP 343-1 communications processor is designed for operation in an S7-300 programmable logic controller. It allows the S7-300 to be attached to Industrial Ethernet.

LED displays

Mode selector

AUI/ITP interface 15-pin sub D

with sliding locking mechanism

Figure 1 CP 343-1

Design

The module has been designed to match the components of the S7-300 programmable logic controller and has the following features:

SDouble-width module for simple installation in the S7-300 rack.

SThe operator controls and displays are all located on the front panel.

SNo fan necessary.

SDirect backplane bus connection of the modules via accompanying backplane module connectors.

S15-pin sub D female connector with sliding locking mechanism for attaching the CP 343-1 to Industrial Ethernet (automatic switchover between the AUI interface and Twisted Pair interface).

Product information CP 343–1

3

C79000–Z8964–C038–05

 

english

Configuration

You can configure the CP 343–1 via MPI or LAN/Industrial Ethernet. You require STEP 7 with the following version of NCM S7 for Industrial Ethernet (abbreviated to ”NCM IE” below):

Table 1

Version STEP7/NCM IE

V2.x to V5.x

V5.x + SP2 or higher

Functionality of the CP 343–1

The same functionality is available as with the previous versions of the CP.

SConfiguration data created with these STEP 7 or NCM versions can be downloaded to the CP 343–1.

The full functionality including the extended functions as listed in Section 1.1 can be used.

Information about the required service pack (SP2) is available on the Internet at: http://www.ad.siemens.de/csi/net

1.1Characteristics

Services

The CP 343-1 supports the following communication services:

SS5-compatible communication with

SEND/RECEIVE interface via ISO transport connections

FETCH/WRITE services (passive; according to the S5 protocol) via ISO transport connections and ISO-on-TCP connections

SS7 communication with

PG functions

Operator control and monitoring functions

Data exchange using communication function blocks

PG functions:

Using the PG functions, modules such as the FM 354 or FM 355 can be accessed via the CP (“extended” PG functions).

4 Product information CP 343–1

C79000–Z8964–C038–05

Siemens CP 343-1 User Manual

english

Note

If there is a diagnostic connection to the CP via the CPU, configuration data cannot be downloaded automatically to the CP by the CPU at the same time!

Extended Functions Compared with Version 5

SReading and writing data in the FETCH/WRITE mode

The services FETCH and WRITE are supported for direct access to system memory areas on the SIMATIC S7 PLC via ISO transport and and ISO-on-TCP connections. The SIMATIC S7-300 with the CP 343-1 is always the server (passive connection establishment), while the fetch or write access (client functionality with active connection establishment) originates from a SIMATIC S5 PLC or other device

Requirements – General Operation

The following table shows the S7–300 CPUs with which the CP 343–1 can be operated with this range of functions:

Table 2

CPU

CPU 312 IFM

CPU 312 (T)

CPU 313

CPU 314

CPU 314 (T)

CPU 314 IFM

CPU 314 IFM (T)

CPU 315

CPU 315–2 DP

CPU 315–2 DP (T)

CPU 316–2 DP

CPU 318–2

MLFB–Number

6ES7 312–5AC02–0AB0

6ES7 312–5AC82–0AB0

6ES7 313–1AD03–0AB0

6ES7 314–1AE04–0AB0

6ES7 314–1AE84–0AB0

6ES7 314–5AE03–0AB0

6ES7 314–5AE83–0AB0

6ES7 315–1AF03–0AB0

6ES7 315–2AF03–0AB0

6ES7 315–2AF83–0AB0

6ES7 316–2AG00–0AB0

6ES7 318–2AJ00–0AB0

Product information CP 343–1

5

C79000–Z8964–C038–05

 

Loading...
+ 15 hidden pages