Siemens 3RA62, RA2 User Manual

0 (0)

© Siemens AG 2011

SIRIUS Motor Starters

6

 

Combination Starters &

 

Starters for Group Installation

 

SIRIUS 3RA2 Motor Starters

6/2

General data

 

3RA21 Direct-On-Line Starters

6/13

AC 50/60 Hz 110/120 V

6/15

24 V DC

 

3RA22 Reversing Starters

6/17

AC 50/60 Hz 110/120 V

6/19

24 V DC

6/21

Accessories

6/31

3RV29 Infeed System for

 

Motor Starters

 

For Operation in the Control Cabinet

 

SIRIUS 3RA6 Compact Starters

6/32

General data

 

3RA61, 3RA62 Compact Starters

6/40

3RA61 direct-on-line starters

6/41

3RA62 reversing starters

 

3RA64, 3RA65 Compact Starters for

 

IO-Link

6/42

3RA64 direct-on-line starters

6/43

3RA65 reversing starters

6/44

Accessories

6/50

Add-On Modules for AS-Interface

6/52

Infeed Systems for 3RA6

Technical Information

can be found at www.siemens.com/industrial-controls/ support

under Product List:

- Technical specifications

under Entry List:

-Updates

-Download

-FAQ

-Manuals

-Characteristics

-Certificates

SIRIUS Innovations Supplement 2011

© Siemens AG 2011

Combination Starters & Starters for Group Installation

SIRIUS 3RA2 Motor Starters

General data

Overview

3RA2 motor starters

The 3RA2 fuseless motor starters consist of the 3RV2 motor starter protector and the 3RT2 electromechanical contactor. The devices are electrically and mechanically connected using preassembled assembly kits (link modules, wiring kits and standard mounting rail or busbar adapters).

Around 500 preassembled 3RA2 combinations of these innovative 3RT2 controls and 3RV2 protection equipment can be ordered for direct-on-line and reversing starting of standard induction motors up to 32 A (approx. 20 HP/460 V).

In the 3RA2 motor starter, the 3RV2 motor starter protector is responsible for overload and short-circuit protection. Back-up protective devices, such as melting fuses or limiters, are superfluous here, as the motor starter protector is capable of withstanding short-circuits up to 65 kA at 480 V and 30 kA at 600 V. See the the actual SCCR ratings by device listed on the selection pages of this chapter.

The 3RT2 contactor is particularly suitable for extremely complex switching tasks requiring the greatest endurance.

The 3RA2 motor starters are available with setting ranges from 0.14 to 32 A in sizes S00 and S0:

Size

Width

Max. rated current

For induction motors

 

 

In max

up to

 

mm

A

HP

 

 

 

 

S00

45

16

10

 

 

 

 

S0

45

32

20

 

 

 

 

The size of the 3RA2 motor starters is based on the size of the contactor:

 

 

 

 

 

 

Size of 3RA2

S00

S0

 

 

 

 

 

6

Size of 3RV2 motor starter protector

S00

S001), S0

 

Size of 3RT2 contactor

S00

S0

 

 

 

 

 

 

1)The combination of an S00 motor starter protector with an S0 contactor is possible only for screw connection versions.

Operating conditions

3RA2 motor starters are climate-proof. They are intended for use in enclosed rooms in which no severe operating conditions (such as dust, caustic vapors, hazardous gases) prevail. Suitable covers must be provided for installation in dusty and damp locations.

Tripping times

All 3RA2 motor starters described here are designed for normal starting, in other words for overload tripping times of less than 10 s (CLASS 10). At rated-load operating temperature the tripping times are shorter, depending on the particular equipment and the setting range. The exact values can be derived from the tripping characteristics of the motor starter protectors.

Connection methods

For all 3RA2 starters up to 32 A, spring-type connection is available as well as screw connection. To connect two devices with spring-type connection there are plug-in connection modules for sizes S00 and S0 which enable very quick mounting of the starters and a vibration-resistant assembly.

To connect a motor starter protector with screw connection to a contactor with spring-type connection there are special hybrid connection modules for S00 and S0.

Screw terminals

Spring-type terminals

These terminals are indicated in the corresponding tables by the symbols shown on orange backgrounds.

While starters can be assembled with either spring-type or screw connection, the pre-assembled versions offered in this chapter are with screw terminals only. For spring-type versions, simply order the components listed on the spring-type terminal pages and assemble these starters quickly and efficiently without the use of any tools.

6/2

SIRIUS Innovations Supplement 2011

 

 

© Siemens AG 2011

Combination Starters & Starters for Group Installation

SIRIUS 3RA2 Motor Starters

3RA2 complete units

The 3RA2 fuseless motor starters can be ordered as preassembled complete units for direct-on-line starting (3RA21) or for reversing duty (3RA22) with screw connection.

Control supply voltages of AC 50/60 Hz 110/120 V and 24 V DC are available to choose from.

A distinction is also drawn between whether the starter is mounted on a 35 mm standard mounting rail, on a flat surface using screws, or on a 60 mm busbar system.

Accessories

As the 3RA2 fuseless motor starters are constructed from 3RV2 motor starter protectors and 3RT2 contactors, the same accessories - such as auxiliary switches, undervoltage releases or door-coupling rotary operating mechanisms - can be used for the 3RA2 fuseless motor starters as for these motor starter protectors and contactors.

In particular, certain accessories have been optimized for the fuseless motor starters. They include the top-connected, transverse auxiliary switch on the motor starter protector, which is available with 1 CO contact or 1 NO contact + 1 NC contact. Special auxiliary switch blocks that can be snapped on from below are available for the contactor. These two accessories enable the fuseless motor starters to be wired simply without having to route cables through the device.

Incoming energy supply

On the whole four different infeed possibilities are available (see "3RV29 Infeed System for Motor Starters" on page 6/31).

Customer assembly of fuseless motor starters

While the preassembled 3RA2 can be ordered up to 32 A, combinations in customer assembly without link modules are also possible up to 40 A (approx. 25 HP/460 V).

General data

The fuseless motor starters can also be assembled easily by the customer. It is simply necessary to assemble the standard 3RV2 motor starter protector, the 3RT2 contactor and the appropriate assembly kit.

For single devices and assembly kits see "Selection and ordering data" for 3RA21 direct-on-line starters and 3RA22 reversing starters.

For assembly kits for direct-on-line starting or reversing duty for mounting on standard mounting rails or busbars see "Selection and ordering data" for "Accessories".

For reversing starters size S0 it is imperative to use a standard mounting rail adapter in order to ensure the necessary mechanical strength. A standard mounting rail adapter is not necessary if a busbar adapter is used.

The 3RA1 fuseless motor starters can be used for the fuseless motor starters between 32 A and 100 A.

The SENTRON 3VL circuit breakers and the SIRIUS 3RT contactors are available for rated currents >100 A.

Special equipment for customer assembly can be ordered if other rated control supply voltages are required. Assembly kits can be used to facilitate assembly.

Customers can also assemble tested combinations of motor starter protectors with solid-state controls (soft starters, solidstate contactors) and motor starters with additional monitoring and control devices (3RR monitoring relays, SIMOCODE 3UF).

For the electrical and mechanical connection of protection equipment and controls there are preassambled assembly kits (link modules, wiring kits and standard mounting rail or busbar adapters).

The following types of configuration are possible:

Direct-on-line/reversing starting (see preassembled 3RA2 combinations)

Thanks to the SIRIUS modular system, the standard devices can

Wye-delta starting (only customer assembly with link module)

be optimally combined in terms of both technical specifications

Solid-state/soft starting (only customer assembly with link

and dimensions.

 

module)

 

 

6

SIRIUS Innovations Supplement 2011

6/3

 

 

6

© Siemens AG 2011

Combination Starters & Starters for Group Installation

SIRIUS 3RA2 Motor Starters

General data

Communications integration using IO-Link

Motor starters can also be assembled with IO-Link for connection to the higher-level control system. For each starter this requires a communication-capable contactor onto which a 3RA27 11 function module is plugged (various versions for direct-on-line, reversing and wye-delta starts). The design of the SIRIUS motor starters permits a group of up to 4 SIRIUS controls to be conveniently connected through a standardized IO-Link to a control system, reducing wiring time considerably compared to the conventional parallel wiring method. The electrical connection is made using only a single cable with three conductors.

The function modules perform not only the communication (contactor operation and feedback, ready signal) but also the electrical interlocking (for reversing and wye-delta starters) and the timing relay function (wye-delta reversing time).

Communication information and control supply voltages are passed on through ribbon cables so that the complete control current wiring on the starter is no longer needed.

The monitoring and maintenance of a plant is made considerably easier by transmitting diverse diagnostics data from the function modules (e. g. missing main and auxiliary voltage, local disconnection…) through IO-Link to the higher-level control system. Also, starters equipped for IO-Link can be conveniently controlled from the control cabinet door using the optional operator panel.

More information:

For IO-Link see Chapter 2 "Industrial Communication"

For 3RA27 function modules see Chapter 3 "Controls – Contactors and Contactor Assemblies" --> "Function Modules".

Communications integration through AS-Interface

Connection of the motor starters to the higher-level control system is possible not only through IO-Link but also through AS-Interface. The AS-Interface connection is recommended wherever motor starters are used in distributed applications. This solution also requires a communication-capable contactor and a corresponding 3RA27 12 function module (various versions for direct-on-line, reversing and wye-delta starts). The devices are implemented in A/B technology, making it easy to connect up to 62 starters to an AS-i master (regardless of whether they are direct-on-line, reversing or wye-delta starters).

This results in a significant reduction of wiring compared to the conventional parallel wiring method. The electrical connection is made using standard cables.

The function modules perform not only the communication (contactor operation and feedback, ready signal) but also the electrical interlocking (for reversing and wye-delta starters) and the timing relay function (wye-delta reversing time).

Communication information and control supply voltages are passed on through ribbon cables so that the complete control current wiring on the starter is no longer needed.

More information:

For AS-Interface see Chapter 2 "Industrial Communication"

For 3RA27 function modules see Chapter 3 "Controls – Contactors and Contactor Assemblies" --> "Function Modules".

Contactors with communication interface

For assembling motor starters with communications integration (AS-i/IO-Link) you need contactors with a communications interface. These contactors are not included as standard in the preassembled 3RA2 motor starters. A motor starter with communications interface must be assembled by the customer from individual devices.

Complete integration in the automation landscape

As the result of the communication connection through IO-Link or AS-i, the SIRIUS motor starters are fully integrated in the automation landscape and can draw on all the advantages of TIA (e. g. integration in the TIA Maintenance Station).

Mounting

3RA2 fuseless motor starters are available:

For mounting onto standard mounting rails TH 35 according to EN 60715 (depth 15 mm)

For mounting onto busbar adapters (busbar center-to-center clearance 60 mm, bar thickness 5 to 10 mm)

The fuseless motor starters are also suitable for screw fixing using two 3RV29 28-0B push-in lugs.

The 3RA2 fuseless motor starters can also be configured with the 3RV29 infeed system (see Chapter 5 "Protection Equipment" --> "SIRIUS 3RV2 Motor Starter Protectors up to 40 A"

Benefits

The 3RA2 fuseless motor starters offer a number of advantages:

Minimum planning and assembly work and far less wiring with the preassembled complete units (only one order number 3RA2)

Plug-in connectors from the motor starter protector to all types of SIRIUS controls, for quicker and error-free assembly of starters with screw and spring-type connection

High planning reliability through consistent combination tests for fuseless (400 V according to IEC) and fused configuration (400 V, 500 V and 690 V according to IEC)

Comprehensive approvals for use world-wide (please ask for details of availability)

Uniform accessories for the two sizes S00 and S0

Spring-type connection possible throughout: Enhanced operational reliability (vibration-resistant wiring) and less wiring work thanks to plug-in connections

Power loss 5 to 10 % smaller than for legacy 3RA1 devices, hence lower power consumption

Connection of starters to the control system through standardized system connection (IO-Link and AS-i), for fast integration in TIA and less wiring work. Requires communication contactor versions which are not offered in pre-assembled 3RA2 starters.

6/4

SIRIUS Innovations Supplement 2011

 

 

Siemens 3RA62, RA2 User Manual

© Siemens AG 2011

Combination Starters & Starters for Group Installation

 

 

SIRIUS 3RA2 Motor Starters

 

 

General data

Direct-on-line starting • For standard rail mounting or screw fixing • Sizes S00 and S0

2 push-in lugs

2 push-in lugs

2 push-in lugs

3RV29 28-0B

3RV29 28-0B

3RV29 28-0B

(only for screw

(only for screw

(only for screw

mounting)

mounting)

mounting)

Motor starter protector

Motor starter protector

Motor starter protector

Size S00/S0

Size S00/S0

Size S00/S0

Screw terminals

Spring-type terminals

Screw terminals

Link module

Link module

Link module

3RA19 21-1DA00

3RA29 11-2AA00 for S00

3RA29 11-2FA00 for S00

(for S00)

3RA29 21-2AA00 for S0

3RA29 21-2FA00 for S0

3RA29 21-1AA00

 

 

(for S0, AC contactor)

 

 

3RA29 21-1BA00

 

 

(for S0, DC contactor)

 

 

Contactor

Contactor

Contactor

Size S00/S0

Size S00/S0

Size S00/S0

Screw terminals

Spring-type terminals

Spring-type terminals

 

 

NSB0_02089

Left: 3RA21 motor starter with screw connection

Center: 3RA21 motor starter with spring-type connection

Right: Motor starter protector combination with screw connection, with contactor with spring-type connection

2 push-in lugs

2 push-in lugs

3RV29 28-0B

3RV29 28-0B

(only for screw mounting)

(only for screw mounting)

Motor starter protector

Size S00/S0

Screw terminals

Link module

3RA29 21-1BA00

Motor starter protector

Size S00/S0 Screw terminals/

spring-type terminals

Link module

3RA29 21-1BA00 for S00/S0 and screw terminals 3RA29 11-2GA00 for S00 and spring-type terminals 3RA29 21-2GA00 for S0 and spring-type terminals

Solid-state

Soft starter

switching device

Size S00/S0

 

Screw terminals/

 

spring-type terminals

 

NSB0_02090

Left: Motor starter protector combination with solid-state switching device with screw connection Right: Motor starter protector combination with soft starter with spring-type connection

6

SIRIUS Innovations Supplement 2011

6/5

 

 

6

© Siemens AG 2011

Combination Starters & Starters for Group Installation

SIRIUS 3RA2 Motor Starters

General data

Direct-on-line starting • For 60 mm busbar systems • Sizes S00 and S0

60 mm busbar adapter

60 mm busbar adapter

for screw terminals

for spring-type terminals

8US12 51-5DS10 for S00

8US12 51-5DT11 for S00

8US12 51-5NT10 for S0

8US12 51-5NT11 for S0

Motor starter protector

 

Size S00/S0

 

Screw terminals

 

 

Motor starter protector

 

Size S00/S0

 

Spring-type terminals

Link module

 

3RA19 21-1DA00 for S00

 

3RA29 21-1AA00 for S0, AC contactor

 

3RA29 21-1BA00 for S0, DC contactor

 

 

Link module

 

3RA29 11-2AA00 for S00

 

3RA29 21-2AA00 for S01)

Contactor

 

Size S00/S0

 

Screw terminals

 

 

Contactor

 

Size S00/S0

 

Spring-type terminals

NSB0_02091a

1) Additional 3RA29 11-1CA00 spacer

for height compensation on AC contactors size S0 with spring-type terminals.

Left: 3RA21 motor starter for direct-on-line starting with busbar adapters with screw connection

Right: 3RA21 motor starter for direct-on-line starting with busbar adapters with spring-type connection

6/6

SIRIUS Innovations Supplement 2011

 

 

© Siemens AG 2011

Combination Starters & Starters for Group Installation

SIRIUS 3RA2 Motor Starters

General data

Reversing duty • For standard rail mounting or screw fixing • Size S00

2 push-in lugs

3RV29 28-0B

(only for screw mounting)

Motor starter protector

Size S00

Screw terminals

Link module

3RA19 21-1DA00 for S00

1

3

2 contactors

Size S00 Screw terminals

4

2

Wiring kit

3RA29 13-2AA1

1Upper wiring module

2Lower wiring module

32 connecting clips

4Mechanical interlock

(can be removed if necessary)

2 push-in lugs

3RV29 28-0B

(only for screw mounting)

Motor starter protector

Size S00 Spring-type terminals

Link module

3RA29 11-2AA00 for S00

1

3

02092a_NSB0 4

2

Wiring kit

3RA29 13-2AA2

1Upper wiring module

2Lower wiring module

32 connecting clips

4Mechanical interlock

(can be removed if necessary)

6

2 contactors

Size S00 Spring-type terminals

Left: 3RA22 motor starter with screw connection, push-in lugs, 2 contactors for reversing duty and 3RA29 13-2AA1 wiring kit for connecting the contactors (incl. mechanical interlocking and connecting clips)

Right: 3RA22 motor starter with spring-type connection, push-in lugs, 2 contactors for reversing duty and 3RA29 13-2AA2 wiring kit (incl. mechanical interlocking and connecting clips)

SIRIUS Innovations Supplement 2011

6/7

 

 

© Siemens AG 2011

Combination Starters & Starters for Group Installation

SIRIUS 3RA2 Motor Starters

General data

Reversing duty • For standard rail mounting • Size S0

RH assembly kit for reversing duty and standard rail mounting in size S0

For screw terminals: 3RA29 23-1BB1

For spring-type terminals: 3RA29 23-1BB21) Comprising:

1 wiring kit

2 standard mounting rail adapters

2 connecting wedges

1)Also includes 3RA29 11-1CA00 spacer for height compensation on AC contactors size S0 with spring-type terminals.

Motor starter protector

Size S0

Screw terminals/ spring-type terminals

Link module

For screw terminals: 3RA29 21-1AA00 (AC) 3RA29 21-1BA00 (DC)

For spring-type terminals: 3RA29 21-2AA002)

1

2 standard mounting rail adapters

3RA29 22-1AA00

with 2 connecting wedges 8US19 98-1AA00

6

3

NSB0_02093b

4

2 contactors

Size S0

Screw terminals/ spring-type terminals

2

2)Additional 3RA29 11-1CA00 spacer

for height compensation on AC contactors size S0 with spring-type terminals

Wiring kit

For screw terminals: 3RA29 23-2AA1

For spring-type terminals: 3RA29 23-2AA2

1Upper wiring module

2Lower wiring module

32 connecting clips

4Mechanical interlock

(can be removed if necessary)

3RA22 motor starter for reversing duty and standard rail mounting in size S0 (the version with screw connection is shown in the picture)

6/8

SIRIUS Innovations Supplement 2011

 

 

© Siemens AG 2011

Combination Starters & Starters for Group Installation

SIRIUS 3RA2 Motor Starters

General data

Reversing duty • For 60 mm busbar systems • Sizes S00 and S0

RS assembly kit for reversing duty and busbar mounting

Screw connection: 3RA29 13-1DB1 for S00 3RA29 23-1DB1 for S0

For spring-type connection: 3RA29 13-1DB2 for S00 3RA29 23-1DB2 for S01)

Comprising: 1 wiring kit

1 busbar adapter

1 device holder

2 connecting wedges

1)Also includes 3RA29 11-1CA00 spacer for height compensation on AC contactors size S0 with spring-type terminals.

Motor starter protector

Size S00/S0 Screw terminals/

spring-type terminals

Link module

For screw terminals: 3RA19 21-1DA00 for S00 3RA29 21-1AA00 for S0, AC contactor 3RA29 21-1BA00 for S0, DC contactor For spring-type terminals:

3RA29 11-2AA00 for S00 3RA29 21-2AA00 for S02)

1

60 mm busbar adapter

For screw terminals: 8US12 51-5DS10 for S00 8US12 51-5NT10 for S0 For spring-type terminals: 8US12 51-5DT11 for S00 8US12 51-5NT11 for S0

2 connecting wedges

8US19 98-1AA00

60 mm device holder

8US12 51-5AS10

6

2)Additional 3RA29 11-1CA00 spacer

for height compensation on AC contactors size S0 with spring-type terminals.

3

 

 

2 contactors

02094b

Size S00/S0

spring-type terminals

 

Screw terminals/

NSB0

 

4

 

Wiring kit

2

Screw connection:

3RA29 13-2AA1 for S00

 

 

3RA29 23-2AA1 for S0

 

Spring-type connection:

 

3RA29 13-2AA2 for S00

 

3RA29 23-2AA2 for S0

 

1

Upper wiring module

 

2

Lower wiring module

 

3

2 connecting clips

 

4

Mechanical interlock

 

 

(can be removed if necessary)

3RA22 motor starter for reversing duty and 60 mm standard mounting rail in size S00/S0 (the version with screw connection is shown in the picture)

SIRIUS Innovations Supplement 2011

6/9

 

 

6

© Siemens AG 2011

Combination Starters & Starters for Group Installation

SIRIUS 3RA2 Motor Starters

General data

Order No. scheme

Digit of the Order No.

1st -

4th

5th

6th

7th

 

8th

9th

10th

11th

12th

 

13th

14th

15th

16th

 

 

3rd

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

@@@

@

@

@

0

@

@

@

@

@

@

@

@

@

 

SIRIUS starters

3 R A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIRIUS 2nd generation

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of starter (direct-on-line starter = 1,

 

 

@

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reversing starter = 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Size (S00 = 1, S0 = 2)

 

 

 

@

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting range for overload release

 

 

 

 

 

 

@

@

 

 

 

 

 

 

 

 

 

Design type and connection method

 

 

 

 

 

 

 

 

@

 

 

 

 

 

 

 

 

Rated power at 460 V AC

 

 

 

 

 

 

 

 

 

@

@

 

 

 

 

 

 

Integrated auxiliary switches of the contactor

 

 

 

 

 

 

 

 

 

 

 

 

@

 

 

 

 

Operating range / solenoid coil circuit (contactor)

 

 

 

 

 

 

 

 

 

 

 

 

 

@

 

 

 

Rated control supply voltage (contactor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

@

@

 

Example

3 R A

2

1

1

0

0

B

A

1

5

1

A

K

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:

The Order No. scheme is presented here merely for information purposes and for better understanding of the logic behind the order numbers.

For your orders, please use the order numbers quote in the catalog in the Selection and ordering data.

Technical specifications

Direct-on-line starters/

Size

Connection methods

Mounting

 

 

 

Control voltage

 

 

Width W

Height H

Depth D

reversing starters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm

mm

mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Direct-on-line starters

S00

Screw terminals

 

Standard mounting rails

 

AC/DC

 

 

45

167

97

 

3RA21.

 

 

 

3RA21 1.

 

 

Busbar adapters

 

 

 

AC/DC

 

 

45

200

155

 

 

 

 

 

 

 

 

 

 

 

 

Spring-type terminals

Standard mounting rails

 

AC/DC

 

 

45

198

97

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Busbar adapters

 

 

 

AC/DC

 

 

45

260

155

 

 

 

 

 

 

 

 

 

 

 

S0

Screw terminals

 

Standard mounting rails

 

AC

 

 

45

193

97

 

H

 

 

 

 

 

 

 

 

3RA21 2.

 

 

 

 

 

 

 

 

 

 

DC

 

 

45

193

107

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

Busbar adapters

 

 

 

AC

 

 

45

260

155

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC

 

 

45

260

165

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Spring-type terminals

Standard mounting rails

 

AC/DC

 

 

45

243

107

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Busbar adapters

 

 

 

AC/DC

 

 

45

260

165

 

Reversing starters

S00

Screw terminals

 

Standard mounting rails

 

AC/DC

 

 

90

170

97

 

3RA22.

 

 

 

3RA22 1.

 

 

Busbar adapters

 

 

 

AC/DC

 

 

90

200

155

 

 

 

 

 

 

 

 

 

 

 

 

Spring-type terminals

Standard mounting rails

 

AC/DC

 

 

90

204

97

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Busbar adapters

 

 

 

AC/DC

 

 

90

260

155

 

 

 

 

 

 

 

 

 

 

 

S0

Screw terminals

 

Standard mounting rail

 

AC

 

 

90

265

120.3

 

 

 

 

 

 

 

 

 

 

 

3RA22 2.

 

 

adapters

 

 

 

DC

 

 

90

265

130

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Busbar adapters

 

 

 

AC

 

 

90

260

155

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC

 

 

90

260

165

 

 

 

 

 

 

 

 

 

 

 

 

Spring-type terminals

Standard mounting rail

 

AC/DC

 

 

90

270

131

 

 

 

 

 

 

 

 

 

 

 

 

 

 

adapters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Busbar adapters

 

 

 

AC/DC

 

 

90

260

165

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

 

 

 

 

 

3RA2. 1

 

 

 

 

 

 

 

 

3RA2. 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S00

 

 

 

 

 

 

 

 

S0

 

 

 

Number of poles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

Mechanics and environment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Permissible ambient temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• During operation

 

 

°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-20 ... +60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Storage and transport

 

 

°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-55 ... +80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

 

 

 

 

 

kg

 

0.6 ... 1.5

 

 

 

 

 

 

 

 

 

0.8 ... 2.3

 

 

 

Permissible mounting

 

 

 

 

 

 

 

 

 

 

22,5°

22,5°

 

 

 

 

 

 

positions

 

 

 

 

 

 

 

90°

 

 

90°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NSB00369

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Important: Acc. to DIN 43602 start command "I" at the right or top

 

 

Shock resistance

Acc. to IEC 60086 Part 2-27

g

 

Up to 6

 

 

 

 

 

 

 

 

Up to 6

 

 

 

(sine-wave pulse)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Degree of protection

Acc. to IEC 60947-1

 

 

IP20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6/10

SIRIUS Innovations Supplement 2011

 

 

© Siemens AG 2011

Combination Starters & Starters for Group Installation

 

 

 

 

 

 

 

SIRIUS 3RA2 Motor Starters

 

 

 

 

 

 

 

 

 

 

General data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

More information

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

3RA2. 1

 

3RA2. 2

 

 

 

 

 

Size

 

 

S00

 

S0

 

 

 

 

 

Number of poles

 

 

3

 

 

3

 

 

 

 

 

 

General data

 

 

 

 

 

 

 

 

 

 

 

 

Standards

 

 

IEC 60947-1, EN 60947-1

 

 

 

 

 

 

 

 

 

 

 

IEC 60947-2, EN 60947-2

 

 

 

 

 

 

 

 

 

 

 

IEC 60947-4-1, EN 60947-4-1

 

 

 

 

 

 

 

 

Max. rated current In max (= max. rated operational current Ie)

A

16

 

 

32

 

 

 

 

 

 

Permissible ambient temperature

°C

-20 ... +60 for operation

 

 

 

 

 

 

 

 

 

 

°C

 

 

 

 

 

 

 

 

-55 ... +80 during storage/transport

 

 

 

 

 

 

Rated operational voltage Ue

 

V

690

 

 

 

 

 

 

 

 

 

Rated frequency

 

Hz

50/60

 

 

 

 

 

 

 

 

 

Rated insulation voltage Ui (pollution degree 3)

V

690

 

 

 

 

 

 

 

 

 

Rated impulse withstand voltage Uimp

kV

6

 

 

 

 

 

 

 

 

 

Trip class (CLASS)

Acc. to IEC 60947-4-1,

 

10

 

 

 

 

 

 

 

 

 

 

EN 60947-4-1

 

 

 

 

 

 

 

 

 

 

 

Rated short-circuit current Iq at AC 50/60 Hz 400 V

kA

153

 

 

 

 

 

 

 

 

 

acc. to IEC 60947-4-1, EN 60947-4-1

 

 

 

 

 

 

 

 

 

 

 

Power loss Pv max of all main

Up to 1.25 A

W

2

 

 

--

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

current paths

1.6 ... 6.3 A

W

2.3

 

 

--

 

 

 

 

 

 

Dependent on the rated current

8 ... 12 A

W

3.5

 

 

--

 

 

 

 

 

 

In

16 A

W

 

 

 

 

 

 

 

 

 

 

4.3

 

 

--

 

 

 

 

 

 

(upper setting range)

5 ... 6.3 A

W

 

 

 

 

 

 

 

 

 

 

--

 

 

2.3

 

 

 

 

 

 

 

8 ... 12 A

W

--

 

 

3.5

 

 

 

 

 

 

 

16 ... 32 A

W

 

 

 

 

 

 

 

 

 

 

 

--

 

 

4.3

 

 

 

 

 

 

Power consumption of the solenoid coils for contactors

 

 

 

 

 

 

 

 

 

 

 

as a function of the standard output P of the motor

 

 

 

 

 

 

 

 

 

 

 

(when coil is cold and Us50 Hz)

 

 

 

 

 

 

 

 

 

 

 

 

• AC operation

 

 

 

 

 

 

 

 

 

 

 

 

- Closing

Up to 4 kW

VA

 

 

 

 

 

 

 

 

 

27

 

 

--

 

 

 

 

 

 

 

5.5 ... 7.5 kW

VA

37

 

 

--

 

 

 

 

 

 

 

Up to 5.5 kW

VA

 

 

 

 

 

 

 

 

 

 

 

--

 

 

65

 

 

 

 

 

 

 

7.5 ... 15 kW

VA

 

 

 

 

 

 

 

 

 

 

 

--

 

 

77

 

 

 

 

 

 

 

P.f.

 

0.8

 

 

0.82

 

 

 

 

 

 

 

 

 

 

 

 

 

- Closed

Up to 4 kW

VA

 

 

 

 

 

 

 

 

 

 

4.2

 

 

--

 

 

 

 

 

 

 

5.5 ... 7.5 kW

VA

 

 

 

 

 

 

 

 

 

 

 

5.7

 

 

--

 

 

 

 

 

 

 

Up to 5.5 kW

VA

--

 

 

8.5

 

 

 

 

 

 

 

7.5 ... 15 kW

VA

 

 

 

 

 

 

 

 

 

 

 

--

 

 

9.8

 

 

 

6

 

 

 

P.f.

 

0.25

 

 

0.25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• DC operation

Closing =

W

4

 

 

5.9

 

 

 

 

 

 

 

Closed

 

 

 

 

 

 

 

 

 

 

 

Solenoid coil operating range for contactors

 

0.8 ... 1.1 x Us

 

 

 

 

 

 

 

 

 

Lower limit at 55 °C

 

0.8 x Us

 

--

 

 

 

 

 

 

 

 

 

 

 

 

 

At 60 °C

 

0.85 x Us

 

--

 

 

 

 

 

 

Endurance of the motor starter protector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Mechanical endurance

Operating cycles

 

100000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Electrical endurance

Operating cycles

 

100000

 

 

 

 

 

 

 

 

• Max. switching frequency per hour (motor starts)

1/h

15

 

 

 

 

 

 

 

 

 

Endurance of contactor

 

 

 

 

 

 

 

 

 

 

 

 

• Mechanical endurance

Operating cycles

 

30 million

 

10 million

 

 

 

 

 

• Electrical endurance

Operating cycles

 

 

 

 

 

 

 

 

 

See endurance characteristic curves of the contactors -->

 

 

 

 

 

 

 

 

Chapter 3 "Controls – Contactors and Contactor Assemblies"

 

 

 

 

 

Shock resistance (sine-wave

Acc. to IEC 60086 Part 2-27

g

Up to 6

 

Up to 6

 

 

 

 

 

 

pulse)

 

 

 

 

 

 

 

 

 

 

 

 

Degree of protection

Acc. to IEC 60947-1

 

IP20

 

 

 

 

 

 

 

 

Touch protection

Acc. to EN 50274

 

Finger-safe

 

 

 

 

 

 

 

 

Phase failure sensitivity

Acc. to IEC 60947-1,

 

Yes

 

 

 

 

 

 

 

 

of the motor starter protector

EN 60947-1

 

 

 

 

 

 

 

 

 

 

 

Isolating features

Acc. to IEC 60947-2,

 

Yes

 

 

 

 

 

 

 

 

of the motor starter protector

EN 60947-2

 

 

 

 

 

 

 

 

 

 

 

Main control and EMER-

Acc. to IEC 60204-1,

 

Yes

 

 

 

 

 

 

 

 

GENCY-STOP switch charac-

EN 60204-1

 

(with overvoltage releases of category "1" under conditions of proper use)

 

 

 

 

 

teristics of the motor starter

 

 

 

 

 

 

 

 

 

 

 

 

protector and accessories

 

 

 

 

 

 

 

 

 

 

 

 

Protective separation between

Acc. to EN 60947-1,

V

Up to 400

 

 

 

 

 

 

 

 

main and auxiliary circuits

Appendix N

 

 

 

 

 

 

 

 

 

 

 

Mirror contacts for contactors

 

 

Yes

 

Yes, from main contact to auxiliary

 

 

 

 

 

 

 

 

 

 

 

 

NC contact

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIRIUS Innovations Supplement 2011

6/11

 

 

© Siemens AG 2011

Combination Starters & Starters for Group Installation

SIRIUS 3RA2 Motor Starters

General data

Type

SIRIUS 3RA2 Motor Starters

 

 

 

Connection type

 

 

 

Screw terminals

 

 

Spring-type terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conductor cross-sections for main conductors

Size S00

 

 

 

 

Motor starter protectors, contactors

Motor starter protectors, contactors

 

 

Terminal screw

 

M3, Pozidriv size 2

--

 

 

 

Operating devices

mm

! 5 ... 6

 

 

3.0 x 0.5 and 3.5 x 0.5

 

 

 

Prescribed tightening torque

Nm

0.8 ... 1.2

 

 

--

 

 

 

Conductor cross-sections (min./max.),

 

 

 

 

 

 

 

 

1 or 2 conductors can be connected

 

 

 

 

 

 

 

 

• Solid and stranded

mm2

2 x (0.5 … 1.5)1) only for contactors,

 

 

 

 

 

mm2

2 x (0.75 ... 2.5)1),

 

 

 

 

 

2 x (0.5 ... 4)

 

 

 

 

mm2

 

 

 

 

 

 

 

 

max. 2 x 4

 

 

 

 

 

 

 

mm2

 

 

 

 

 

 

 

• Finely stranded without end sleeve

--

 

 

2 x (0.5 ... 2.5)

 

 

 

• Finely stranded with end sleeves (DIN 46 228 T1) mm2

 

 

 

 

 

 

2 x (0.5 ... 1.5)1).

2 x (0.5 ... 2.5)

 

 

 

 

mm2

2 x (0.75 ... 2.5)1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• AWG cables, solid or stranded

AWG

2 x (20 … 16)1) only for contactors,

 

 

 

 

 

AWG

2 x (18 ... 14)1),

 

 

 

 

 

 

 

2 x (20 ... 12)

 

 

 

 

AWG

 

 

 

 

 

 

 

 

2 x 12

 

 

 

 

 

 

Max. external diameter of the conductor insulation

mm

--

 

 

3.6

 

 

 

Conductor cross-sections for main conductors

 

 

 

 

 

 

 

Size S0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor starter protectors, contactors

Motor starter protectors, contactors

 

 

Terminal screw

 

M4, Pozidriv size 2

--

 

 

 

Operating devices

mm

! 5 ... 6

 

 

3.0 x 0.5 and 3.5 x 0.5

 

 

 

Prescribed tightening torque

Nm

2.0 ... 2.5

 

 

--

 

 

 

Conductor cross-sections (min./max.),

 

 

 

 

 

 

 

 

1 or 2 conductors can be connected

 

 

 

 

 

 

 

 

• Solid and stranded

mm2

2 x (1.0 ... 2.5)1),

2 x (1.0 ... 10)

 

 

 

 

mm2

2 x (2.5 ... 10)1)

 

 

 

 

 

 

 

 

 

 

 

• Finely stranded without end sleeve

mm2

--

 

 

2 x (1.0 ... 6.0)

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

2

2 x (1.0 ... 2.5)

1)

,

2 x (1.0 ... 6.0)

 

 

 

• Finely stranded with end sleeves (DIN 46 228 T1) mm

 

 

 

 

 

mm2

2 x (2.5 ... 6)1)

 

 

 

 

 

 

 

mm2

 

 

 

 

 

 

 

 

max. 1 x 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• AWG cables, solid or stranded

AWG

2 x (16 ... 12)1),

 

2 x (18 ... 8)

 

 

 

 

AWG

2 x (14 ... 8)1)

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. external diameter of the conductor insulation

mm

--

 

 

3.6

 

 

 

Conductor cross-sections for auxiliary

 

 

 

 

 

 

 

 

conductors, Size S00/S0

 

 

 

 

 

 

 

 

 

 

Contactors (basic unit),

Contactors S00

Contactors S0,

 

 

 

 

motor starter protectors (accessories),

 

motor starter protec-

 

 

 

 

contactors (mountable accessories),

 

tors (accessories),

 

 

 

 

overload relays

 

contactors

 

 

 

 

 

 

 

 

(accessories),

 

 

 

 

 

 

 

 

overload relays

 

 

Terminal screw

 

M3, Pozidriv size 2

--

 

 

 

Operating devices

mm

! 5 ... 6

 

 

3.0 x 0.5 and 3.5 x 0.5

 

 

 

Prescribed tightening torque

Nm

0.8 ... 1.2

 

 

--

 

 

 

Conductor cross-sections (min./max.),

 

 

 

 

 

 

 

 

1 or 2 conductors can be connected

 

 

 

 

 

 

 

 

• Solid and stranded

mm2

2 x (0.5 ... 1.5)1),

2 x (0.5 ... 4)

2 x (0.5 ... 2.5)

 

 

 

mm2

2 x (0.75 ... 2.5)1),

 

 

 

 

 

 

 

 

 

 

mm2

 

 

 

 

 

 

max. 2 x 4 only for contactors S00

 

 

 

 

• Finely stranded without end sleeve

mm2

--

 

 

2 x (0.5 ... 2.5)

2 x (0.5 ... 1.5)

 

 

 

 

 

 

 

mm2

 

 

 

 

 

 

 

• Finely stranded with end sleeve

2 x (0.5 ... 1.5)1),

2 x (0.5 ... 2.5)

2 x (0.5 ... 1.5)

 

 

 

mm2

2 x (0.75 ... 2.5)1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• AWG cables, solid or stranded

AWG

2 x (20 ... 16)1),

 

2 x (20 ... 12)

2 x (20 ... 14)

 

 

 

AWG

2 x (18 ... 14)1),

 

 

 

 

 

 

 

 

 

 

 

 

AWG

 

 

 

 

 

 

2 x 12 only for contactors S00

 

 

 

 

Max. external diameter of the conductor insulation

mm

--

 

 

3.6

3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

1)If two different conductor cross-sections are connected to one clamping point, both cross-sections must lie in the range specified. If identical crosssections are used, this restriction does not apply.

6/12

SIRIUS Innovations Supplement 2011

 

 

© Siemens AG 2011

Combination Starters & Starters for Group Installation

SIRIUS 3RA2 Motor Starters

3RA21 direct-on-line starters 50/60 Hz 110/120 V AC

Selection and ordering data

Direct-on-line starting

3RA21 10

3RA21 20

3RA21 10

3RA21 20

Rated control supply voltage 50/60 Hz 110/120 V AC With screw connections

The motor starter protector and contactor are mechanically and electrically connected by means of the link module.

Auxiliary switches1) on the motor starter protector and the contactor can be easily fitted due to the modular system.

Integrated auxiliary switches:

-Contactor size S00: 1 NO;

-Contactor size S0: 1 NO + 1 NC

Combination Starter, UL508 Type F

All size S00 and S0 devices can be applied as Combination Starters with the addition of either of these line side connectors: 3RV29 28-1H, 3RV29 25-5EB or 3RV29 28-1K.

Size

UL Data

 

 

 

 

 

 

FLA setting

Consisting of the following single

 

Assembled starter

 

 

 

 

Weight

 

 

 

 

 

 

 

 

 

 

range inverse-

devices

 

 

 

 

 

 

 

 

 

 

 

 

approx.

 

Single-phase

 

Three-phase2)

 

 

SCCR

time delayed

Motor

+ Contactor

+ Link

 

Screw terminals

 

 

 

 

 

 

HP ratings

 

HP ratings

 

 

at

overload

starter

 

module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

release

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

480 V

protector

 

+ Busbar

 

 

 

 

 

 

 

 

 

 

 

 

115 V

230 V

 

200 V

230 V

 

460 V

575 V

 

 

 

 

 

 

 

 

 

 

 

 

adapter3)

 

Order No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kA

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kg

Selection depends on motor full load amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3RV20

3RT20

3RA

 

 

 

 

 

 

 

 

 

 

 

S00

--

--

 

--

--

 

--

--

65

0.14…0.2

11-0BA10 15-1AK61

1921-1DA00

 

3RA21 10-0B@15-1AK6

 

 

 

 

0.575

 

--

--

 

--

--

 

--

--

65

0.18…0.25

11-0CA10

 

+ 8US1251-

 

3RA21 10-0C@15-1AK6

 

 

 

 

0.575

 

--

--

 

--

--

 

--

--

65

0.22…0.32

11-0DA10

 

5DS10

 

 

 

 

 

 

0.575

 

 

 

 

 

3RA21 10-0D@15-1AK6

 

 

 

 

 

--

--

 

--

--

 

--

--

65

0.28…0.4

11-0EA10

 

 

 

3RA21 10-0E@15-1AK6

 

 

 

 

0.575

 

--

--

 

--

--

 

--

--

65

0.35…0.5

11-0FA10

 

 

 

 

 

 

 

 

0.575

 

 

 

 

 

 

3RA21 10-0F@15-1AK6

 

 

 

 

 

--

--

 

--

--

 

--

--

65

0.45…0.63

11-0GA10

 

 

 

3RA21 10-0G@15-1AK6

 

 

 

 

0.575

 

--

--

 

--

--

 

--

--

65

0.55…0.8

11-0HA10

 

 

 

3RA21 10-0H@15-1AK6

 

 

 

 

0.575

 

--

--

 

--

--

 

--

1/2

65

0.7…

1

11-0JA10

 

 

 

 

 

 

 

 

0.575

 

 

 

 

 

 

3RA21 10-0J@15-1AK6

 

 

 

 

 

--

--

 

--

--

 

1/2

1/2

65

0.9…

1.25

11-0KA10

 

 

 

 

 

 

 

 

0.575

 

 

 

 

 

 

3RA21 10-0K@15-1AK6

 

 

 

 

 

--

1/10

 

--

--

 

3/4

3/4

65

1.1…

1.6

11-1AA10

 

 

 

3RA21 10-1A@15-1AK6

 

 

 

 

0.575

 

--

1/8

 

--

--

 

3/4

1

65

1.4…

2

11-1BA10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3RA21 10-1B@15-1AK6

 

 

 

 

0.575

 

--

1/6

 

1/2

1/2

 

1

1 1/2

65

1.8…

2.5

11-1CA10

 

 

 

 

 

 

 

 

0.575

 

 

 

 

 

 

3RA21 10-1C@15-1AK6

 

 

 

 

 

1/10

1/4

 

1/2

3/4

 

1 1/2

2

65

2.2… 3.2

11-1DA10

 

 

 

3RA21 10-1D@15-1AK6

 

 

 

 

0.575

 

1/8

1/3

 

3/4

3/4

 

2

3

65

2.8… 4

11-1EA10

 

 

 

 

 

 

 

 

0.575

 

 

 

 

 

 

3RA21 10-1E@15-1AK6

 

 

 

 

 

1/6

1/2

 

1

1

 

3

3

65

3.5… 5

11-1FA10

 

 

 

3RA21 10-1F@15-1AK6

 

 

 

 

0.575

 

1/4

1/2

 

1

1 1/2

 

3

5

65

4.5… 6.3

11-1GA10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3RA21 10-1G@15-1AK6

 

 

 

 

0.575

 

1/3

1

 

2

2

 

5

5

65

5.5… 8

11-1HA10 16-1AK61

 

 

 

 

 

 

 

0.575

 

 

 

 

 

3RA21 10-1H@16-1AK6

 

 

 

 

 

1/2

1 1/2

 

2

3

 

5

7 1/2

65

7… 10

11-1JA10

 

 

 

3RA21 10-1J@16-1AK6

 

 

 

 

0.575

 

1/2

2

 

3

3

 

7 1/2

10

65

9… 12

11-1KA10 17-1AK61

 

 

 

 

 

 

 

0.575

 

 

 

 

 

3RA21 10-1K@17-1AK6

 

 

 

 

 

1

2

 

3

5

 

10

--

65

11… 16

11-4AA10 18-1AK61

 

 

 

 

 

 

 

0.575

 

 

 

 

 

3RA21 10-4A@18-1AK6

 

 

 

 

S0

1/6

1/2

 

1

1

 

3

3

65

3.5… 5

11-1FA10 24-1AK60

2921-1AA00

 

3RA21 20-1F@24-0AK6

 

 

 

 

0.761

 

1/4

1/2

 

1

1 1/2

 

3

5

65

4.5… 6.3

11-1GA10

 

+ 8US1251-

 

3RA21 20-1G@24-0AK6

 

 

 

 

0.761

 

1/3

1

 

2

2

 

5

5

65

5.5… 8

11-1HA10

 

5NT10

 

 

 

 

 

 

0.761

 

 

 

 

 

3RA21 20-1H@24-0AK6

 

 

 

 

 

1/2

1 1/2

 

2

3

 

5

7 1/2

65

7…

10

11-1JA10

 

 

 

 

 

 

 

 

0.761

 

 

 

 

 

 

3RA21 20-1J@24-0AK6

 

 

 

 

 

1/2

2

 

3

3

 

7 1/2

10

65

9…

12.5

11-1KA10

 

 

 

3RA21 20-1K@24-0AK6

 

 

 

 

0.761

 

1

2

 

3

5

 

10

--

65

11… 16

21-4AA10 26-1AK60

 

 

3RA21 20-4A@26-0AK6

 

 

 

 

0.761

 

1 1/2

3

 

5

5

 

10

--

65

14… 20

21-4BA10

 

 

 

 

 

 

 

 

0.761

 

 

 

 

 

 

3RA21 20-4B@26-0AK6

 

 

 

 

 

1 1/2

3

 

5

7 1/2

 

15

--

50

17… 22

21-4CA10 27-1AK60

 

 

3RA21 20-4C@27-0AK6

 

 

 

 

0.761

 

2

3

 

5

7 1/2

 

15

--

50

20… 25

21-4DA10

 

 

 

 

 

 

 

 

0.761

 

 

 

 

 

 

3RA21 20-4D@27-0AK6

 

 

 

 

 

2

5

 

7 1/2

10

 

20

--

50

27… 32

21-4EA10

 

 

 

 

 

 

 

 

0.761

 

 

 

 

 

 

3RA21 20-4E@27-0AK6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Add. weight

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Order No. supplement for mounting onto standard mounting rail or screw fixing

 

 

 

 

 

 

A

 

 

 

 

 

 

Screw fixing with 1 push-in lug each per motor starter is possible

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(see "Accessories for Direct-On-Line and Reversing Starters").

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Order No. supplement for mounting onto 60 mm busbar

 

 

 

 

for size S00

 

 

1

 

D

 

0.263

With busbar adapter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for size S0

 

 

2

 

D

 

0.295

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)For auxiliary switches see Accessories page 6/21.

2)Selection depends on the motor full load amps. HP ratings for reference only.

3)Used only for mounting starter on 8US Fast Bus busbar systems.

6

Illustrations are approximate

SIRIUS Innovations Supplement 2011

6/13

 

 

 

6

© Siemens AG 2011

Combination Starters & Starters for Group Installation

SIRIUS 3RA2 Motor Starters

3RA21 direct-on-line starters 50/60 Hz 110/120 V AC

Direct-on-line starting

3RA21 10

3RA21 20

3RA21 10

3RA21 20

Rated control supply voltage 50/60 Hz 110/120 V AC With spring-type connection

These starters can be assembled in the field without tools by simply snapping the components together. Follow the simple component selection system to form a starter.

Auxiliary switches1) on the motor starter protector and the contactor can be easily fitted due to the modular system.

Integrated auxiliary switches:

-Contactor size S00: 1 NO;

-Contactor size S0: 1 NO + 1 NC

Combination Starter, UL508 Type F

All size S00 and S0 devices can be applied as Combination Starters with the addition of either of these line side connectors: 3RV29 28-1H, 3RV29 25-5EB or 3RV29 28-1K.

Size

UL Data

 

 

 

 

 

 

FLA setting

Consisting of the following single devices

 

Not available

Weight

 

 

 

 

 

 

 

 

 

range inverse-

 

 

 

 

 

pre-assembled

approx.

 

Single-phase

Three-phase2)

 

 

SCCR

time delayed

Motor

+ Contactor

+ Link module

+ Busbar

 

Spring-type

 

 

 

 

HP ratings

HP ratings

 

 

at

overload

starter

 

 

adapter3)

 

terminals

 

 

 

 

 

 

 

 

 

 

 

480 V

release

protector

 

 

 

 

 

 

 

 

 

115 V

230 V

200 V

230 V

 

460 V

575 V

 

 

 

 

 

 

 

 

 

 

 

 

 

Order No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kA

A

 

 

 

 

 

 

 

 

 

 

kg

Selection depends on motor full load amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3RV20

3RT20

3RA

8US12

 

 

 

 

 

S00

--

--

--

--

 

--

--

65

0.14…0.2

11-0BA20

15-2AK61

2911-2AA00

51-5DT11

 

 

 

 

0.641

 

--

--

--

--

 

--

--

65

0.18…0.25

11-0CA20

 

 

 

 

 

 

 

0.641

 

--

--

--

--

 

--

--

65

0.22…0.32

11-0DA20

 

 

 

 

 

 

 

0.641

 

--

--

--

--

 

--

--

65

0.28…0.4

11-0EA20

 

 

 

 

 

 

 

0.641

 

--

--

--

--

 

--

--

65

0.35…0.5

11-0FA20

 

 

 

 

 

 

 

0.641

 

--

--

--

--

 

--

--

65

0.45…0.63

11-0GA20

 

 

 

 

 

 

 

0.641

 

--

--

--

--

 

--

--

65

0.55…0.8

11-0HA20

 

 

 

 

 

 

 

0.641

 

--

--

--

--

 

--

1/2

65

0.7…

1

11-0JA20

 

 

 

 

 

 

 

0.641

 

--

--

--

--

 

1/2

1/2

65

0.9…

1.25

11-0KA20

 

 

 

 

 

 

 

0.641

 

--

1/10

--

--

 

3/4

3/4

65

1.1…

1.6

11-1AA20

 

 

 

 

 

 

 

0.641

 

--

1/8

--

--

 

3/4

1

65

1.4…

2

11-1BA20

 

 

 

 

 

 

 

0.641

 

--

1/6

1/2

1/2

 

1

1 1/2

65

1.8… 2.5

11-1CA20

 

 

 

 

 

 

 

0.641

 

1/10

1/4

1/2

3/4

 

1 1/2

2

65

2.2… 3.2

11-1DA20

 

 

 

 

 

 

 

0.641

 

1/8

1/3

3/4

3/4

 

2

3

65

2.8… 4

11-1EA20

 

 

 

 

 

 

 

0.641

 

1/6

1/2

1

1

 

3

3

65

3.5… 5

11-1FA20

 

 

 

 

 

 

 

0.641

 

1/4

1/2

1

1 1/2

 

3

5

65

4.5… 6.3

11-1GA20

 

 

 

 

 

 

 

0.641

 

1/3

1

2

2

 

5

5

65

5.5… 8

11-1HA20

16-2AK61

 

 

 

 

 

 

0.641

 

1/2

1 1/2

2

3

 

5

7 1/2

65

7… 10

11-1JA20

 

 

 

 

 

 

 

0.641

 

1/2

2

3

3

 

7 1/2

10

65

9… 12

11-1KA20

17-1AK61

 

 

 

 

 

 

0.641

 

1

2

3

5

 

10

--

65

11…

16

11-4AA20

18-2AK61

 

 

 

 

 

 

0.641

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S0

1/6

1/2

1

1

 

3

3

65

3.5… 5

11-1FA20

24-2AK60 2921-2AA004)

51-5NT11

 

 

 

 

0.925

 

1/4

1/2

1

1 1/2

 

3

5

65

4.5… 6.3

11-1GA20

 

+2911-1CA005)

 

 

 

 

 

0.925

 

1/3

1

2

2

 

5

5

65

5.5… 8

11-1HA20

 

 

 

 

 

 

 

0.925

 

1/2

1 1/2

2

3

 

5

7 1/2

65

7…

10

11-1JA20

 

 

 

 

 

 

 

0.925

 

1/2

2

3

3

 

7 1/2

10

65

9…

12.5

11-1KA20

 

 

 

 

 

 

 

0.925

 

1

2

3

5

 

10

--

65

11…

16

21-4AA20

26-2AK60

 

 

 

 

 

 

0.925

 

1 1/2

3

5

5

 

10

--

65

14…

20

21-4BA20

 

 

 

 

 

 

 

0.925

 

1 1/2

3

5

7 1/2

 

15

--

50

17…

22

21-4CA20

27-2AK60

 

 

 

 

 

 

0.925

 

2

3

5

7 1/2

 

15

--

50

20…

25

21-4DA20

 

 

 

 

 

 

 

0.925

 

2

5

7 1/2

10

 

20

--

50

27…

32

21-4EA20

 

 

 

 

 

 

 

0.925

Screw fixing with 1 push-in lug each per motor starter is possible (see "Accessories for Direct-On-Line and Reversing Starters").

1)For auxiliary switches see Accessories page 6/21.

2)Selection depends on motor full load amps. HP ratings for reference only.

3)Use only for mounting starter on 8US Fast Bus busbar systems.

4)Mounting on standard mounting rails with adapter (3RA29 22-1AA00) is possible for feeder-orientated assembly, in which case the contactor must be screwed onto the adapter.

5)For the AC version size S0 with spring loaded terminals, a 3RA29 111CA00 spacer is required for height compensation of the contactor.

6/14

SIRIUS Innovations Supplement 2011

Illustrations are approximate

 

 

 

© Siemens AG 2011

Combination Starters & Starters for Group Installation

SIRIUS 3RA2 Motor Starters

3RA21 direct-on-line starters 24 V DC

Direct-on-line starting

3RA21 10

3RA21 20

3RA21 10

3RA21 20

Rated control supply voltage 24 V DC

With screw connections

The motor starter protector and contactor are mechanically and electrically connected by means of the link module.

Auxiliary switches1) on the motor starter protector and the contactor can be easily fitted due to the modular system.

Integrated auxiliary switches:

-Contactor size S00: 1 NO;

-Contactor size S0: 1 NO + 1 NC

Combination Starter, UL508 Type F

All size S00 and S0 devices can be applied as Combination Starters with the addition of either of these line side connectors: 3RV29 28-1H, 3RV29 25-5EB or 3RV29 28-1K.

Size

UL Data

 

 

 

 

 

 

FLA setting

Consisting of the following

 

Assembled starter

 

 

 

 

Weight

 

 

 

 

 

 

 

 

 

 

range inverse-

single devices

 

 

 

 

 

 

 

 

 

 

 

approx.

 

Single-phase

 

Three-phase2)

 

 

SCCR

time delayed

Motor

+ Contactor

+ Link

 

Screw terminals

 

 

 

 

 

 

HP ratings

 

HP ratings

 

 

at

overload

starter

 

module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

release

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

480 V

protector

 

+ Busbar

 

 

 

 

 

 

 

 

 

 

 

 

115 V

230 V

 

200 V

230 V

 

460 V

575 V

 

 

 

 

 

 

 

 

 

 

 

 

adapter3)

 

Order No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kA

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kg

Selection depends on motor full load amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3RV20

3RT20

3RA

 

 

 

 

 

 

 

 

 

 

 

S00

--

--

 

--

--

 

--

--

65

0.14…0.2

11-0BA10 15-1BB41

1921-1DA00

 

3RA21 10-0B@15-1BB4

 

 

 

 

0.630

 

--

--

 

--

--

 

--

--

65

0.18…0.25

11-0CA10

 

+ 8US1251-

 

 

 

 

 

 

0.630

 

 

 

 

 

3RA21 10-0C@15-1BB4

 

 

 

 

 

--

--

 

--

--

 

--

--

65

0.22…0.32

11-0DA10

 

5DS10

 

3RA21 10-0D@15-1BB4

 

 

 

 

0.630

 

--

--

 

--

--

 

--

--

65

0.28…0.4

11-0EA10

 

 

 

3RA21 10-0E@15-1BB4

 

 

 

 

0.630

 

--

--

 

--

--

 

--

--

65

0.35…0.5

11-0FA10

 

 

 

 

 

 

 

 

0.630

 

 

 

 

 

 

3RA21 10-0F@15-1BB4

 

 

 

 

 

--

--

 

--

--

 

--

--

65

0.45…0.63

11-0GA10

 

 

 

3RA21 10-0G@15-1BB4

 

 

 

 

0.630

 

--

--

 

--

--

 

--

--

65

0.55…0.8

11-0HA10

 

 

 

3RA21 10-0H@15-1BB4

 

 

 

 

0.630

 

--

--

 

--

--

 

--

1/2

65

0.7…

1

11-0JA10

 

 

 

 

 

 

 

 

0.630

 

 

 

 

 

 

3RA21 10-0J@15-1BB4

 

 

 

 

 

--

--

 

--

--

 

1/2

1/2

65

0.9…

1.25

11-0KA10

 

 

 

 

 

 

 

 

0.630

 

 

 

 

 

 

3RA21 10-0K@15-1BB4

 

 

 

 

 

--

1/10

 

--

--

 

3/4

3/4

65

1.1…

1.6

11-1AA10

 

 

 

3RA21 10-1A@15-1BB4

 

 

 

 

0.630

 

--

1/8

 

--

--

 

3/4

1

65

1.4… 2

11-1BA10

 

 

 

3RA21 10-1B@15-1BB4

 

 

 

 

0.630

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

--

1/6

 

1/2

1/2

 

1

1 1/2

65

1.8…

2.5

11-1CA10

 

 

 

 

 

 

 

 

0.630

 

 

 

 

 

 

3RA21 10-1C@15-1BB4

 

 

 

 

 

1/10

1/4

 

1/2

3/4

 

1 1/2

2

65

2.2… 3.2

11-1DA10

 

 

 

3RA21 10-1D@15-1BB4

 

 

 

 

0.630

 

1/8

1/3

 

3/4

3/4

 

2

3

65

2.8… 4

11-1EA10

 

 

 

 

 

 

 

 

0.630

 

 

 

 

 

 

3RA21 10-1E@15-1BB4

 

 

 

 

 

1/6

1/2

 

1

1

 

3

3

65

3.5… 5

11-1FA10

 

 

 

3RA21 10-1F@15-1BB4

 

 

 

 

0.630

 

1/4

1/2

 

1

1 1/2

 

3

5

65

4.5… 6.3

11-1GA10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3RA21 10-1G@15-1BB4

 

 

 

 

0.630

 

1/3

1

 

2

2

 

5

5

65

5.5… 8

11-1HA10 16-1BB41

 

 

 

 

 

 

 

0.630

 

 

 

 

 

3RA21 10-1H@16-1BB4

 

 

 

 

 

1/2

1 1/2

 

2

3

 

5

7 1/2

65

7… 10

11-1JA10

 

 

 

3RA21 10-1J@16-1BB4

 

 

 

 

0.630

 

1/2

2

 

3

3

 

7 1/2

10

65

9… 12

11-1KA10 17-1BB41

 

 

 

 

 

 

 

0.630

 

 

 

 

 

3RA21 10-1K@17-1BB4

 

 

 

 

 

1

2

 

3

5

 

10

--

65

11… 16

11-4AA10 18-1BB41

 

 

 

 

 

 

 

0.630

 

 

 

 

 

3RA21 10-4A@18-1BB4

 

 

 

 

S0

1/6

1/2

 

1

1

 

3

3

65

3.5… 5

11-1FA10 24-1BB40

2921-1BA00

 

3RA21 20-1F@24-0BB4

 

 

 

 

0.948

 

1/4

1/2

 

1

1 1/2

 

3

5

65

4.5… 6.3

11-1GA10

 

+ 8US1251-

 

 

 

 

 

 

0.948

 

 

 

 

 

3RA21 20-1G@24-0BB4

 

 

 

 

 

1/3

1

 

2

2

 

5

5

65

5.5… 8

11-1HA10

 

5NT10

 

 

 

 

 

 

0.948

 

 

 

 

 

3RA21 20-1H@24-0BB4

 

 

 

 

 

1/2

1 1/2

 

2

3

 

5

7 1/2

65

7…

10

11-1JA10

 

 

 

3RA21 20-1J@24-0BB4

 

 

 

 

0.948

 

1/2

2

 

3

3

 

7 1/2

10

65

9…

12.5

11-1KA10

 

 

 

 

 

 

 

 

0.948

 

 

 

 

 

 

3RA21 20-1K@24-0BB4

 

 

 

 

 

1

2

 

3

5

 

10

--

65

11… 16

21-4AA10 26-1BB40

 

 

3RA21 20-4A@26-0BB4

 

 

 

 

0.948

 

1 1/2

3

 

5

5

 

10

--

65

14… 20

21-4BA10

 

 

 

 

 

 

 

 

0.948

 

 

 

 

 

 

3RA21 20-4B@26-0BB4

 

 

 

 

 

1 1/2

3

 

5

7 1/2

 

15

--

50

17… 22

21-4CA10 27-1BB40

 

 

3RA21 20-4C@27-0BB4

 

 

 

 

0.948

 

2

3

 

5

7 1/2

 

15

--

50

20… 25

21-4DA10

 

 

 

3RA21 20-4D@27-0BB4

 

 

 

 

0.948

 

2

5

 

7 1/2

10

 

20

--

50

27… 32

21-4EA10

 

 

 

 

 

 

 

 

0.948

 

 

 

 

 

 

3RA21 20-4E@27-0BB4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Add. weight

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Order No. supplement for mounting onto standard mounting rail or screw fixing

 

 

 

 

 

 

A

 

 

 

 

 

 

Screw fixing with 1 push-in lug each per motor starter is possible

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(see "Accessories for Direct-On-Line and Reversing Starters").

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Order No. supplement for mounting onto 60 mm busbar

 

 

 

 

for size S00

 

 

1

 

D

 

0.263

With busbar adapter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for size S0

 

 

2

 

D

 

0.301

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)For auxiliary switches see Accessories page 6/21.

2)Selection depends on the concrete motor full load amps. HP ratings for reference only.

3)Use only for mounting starter on 8US Fast Bus busbar systems.

6

Illustrations are approximate

SIRIUS Innovations Supplement 2011

6/15

 

 

 

6

© Siemens AG 2011

Combination Starters & Starters for Group Installation

SIRIUS 3RA2 Motor Starters

3RA21 direct-on-line starters 24 V DC

Direct-on-line starting

3RA21 10

3RA21 20

3RA21 10

3RA21 20

Rated control supply voltage 24 V DC

With spring-type connection

These starters can be assembled in the field without tools by simply snapping the components together. Follow the simple component selection system to form a starter.

Auxiliary switches1) on the motor starter protector and the contactor can be easily fitted due to the modular system.

Integrated auxiliary switches:

-Contactor size S00: 1 NO;

-Contactor size S0: 1 NO + 1 NC

Combination Starter, UL508 Type F

All size S00 and S0 devices can be applied as Combination Starters with the addition of either of these line side connectors: 3RV29 28-1H, 3RV29 25-5EB or 3RV29 28-1K.

Size

UL Data

 

 

 

 

 

 

FLA setting

Consisting of the following single devices

 

Not available

Weight

 

 

 

 

 

 

 

 

 

range inverse-

 

 

 

 

 

pre-assembled

approx.

 

Single-phase

Three-phase2)

 

 

SCCR

time delayed

Motor

+ Contactor

+ Link module

+ Busbar

 

Spring-type

 

 

 

 

HP ratings

HP ratings

 

 

at

overload

starter

 

 

adapter3)

 

terminals

 

 

 

 

 

 

 

 

 

 

 

480 V

release

protector

 

 

 

 

 

 

 

 

 

115 V

230 V

200 V

230 V

 

460 V

575 V

 

 

 

 

 

 

 

 

 

 

 

 

 

Order No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kA

A

 

 

 

 

 

 

 

 

 

 

kg

Selection depends on motor full load amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3RV20

3RT20

3RA

8US12

 

 

 

 

 

S00

--

--

--

--

 

--

--

65

0.14…0.2

11-0BA20

15-2BB41

2911-2AA00

51-5DT11

 

 

 

 

0.641

 

--

--

--

--

 

--

--

65

0.18…0.25

11-0CA20

 

 

 

 

 

 

 

0.641

 

--

--

--

--

 

--

--

65

0.22…0.32

11-0DA20

 

 

 

 

 

 

 

0.641

 

--

--

--

--

 

--

--

65

0.28…0.4

11-0EA20

 

 

 

 

 

 

 

0.641

 

--

--

--

--

 

--

--

65

0.35…0.5

11-0FA20

 

 

 

 

 

 

 

0.641

 

--

--

--

--

 

--

--

65

0.45…0.63

11-0GA20

 

 

 

 

 

 

 

0.641

 

--

--

--

--

 

--

--

65

0.55…0.8

11-0HA20

 

 

 

 

 

 

 

0.641

 

--

--

--

--

 

--

1/2

65

0.7…

1

11-0JA20

 

 

 

 

 

 

 

0.641

 

--

--

--

--

 

1/2

1/2

65

0.9…

1.25

11-0KA20

 

 

 

 

 

 

 

0.641

 

--

1/10

--

--

 

3/4

3/4

65

1.1…

1.6

11-1AA20

 

 

 

 

 

 

 

0.641

 

--

1/8

--

--

 

3/4

1

65

1.4…

2

11-1BA20

 

 

 

 

 

 

 

0.641

 

--

1/6

1/2

1/2

 

1

1 1/2

65

1.8… 2.5

11-1CA20

 

 

 

 

 

 

 

0.641

 

1/10

1/4

1/2

3/4

 

1 1/2

2

65

2.2… 3.2

11-1DA20

 

 

 

 

 

 

 

0.641

 

1/8

1/3

3/4

3/4

 

2

3

65

2.8… 4

11-1EA20

 

 

 

 

 

 

 

0.641

 

1/6

1/2

1

1

 

3

3

65

3.5… 5

11-1FA20

 

 

 

 

 

 

 

0.641

 

1/4

1/2

1

1 1/2

 

3

5

65

4.5… 6.3

11-1GA20

 

 

 

 

 

 

 

0.641

 

1/3

1

2

2

 

5

5

65

5.5… 8

11-1HA20

16-2BB41

 

 

 

 

 

 

0.641

 

1/2

1 1/2

2

3

 

5

7 1/2

65

7… 10

11-1JA20

 

 

 

 

 

 

 

0.641

 

1/2

2

3

3

 

7 1/2

10

65

9… 12

11-1KA20

17-2BB41

 

 

 

 

 

 

0.641

 

1

2

3

5

 

10

--

65

11…

16

11-4AA20

18-2BB41

 

 

 

 

 

 

0.641

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S0

1/6

1/2

1

1

 

3

3

65

3.5… 5

11-1FA20

24-2BB40

2921-2AA00

51-5NT11

 

 

 

 

0.925

 

1/4

1/2

1

1 1/2

 

3

5

65

4.5… 6.3

11-1GA20

 

 

 

 

 

 

 

0.925

 

1/3

1

2

2

 

5

5

65

5.5… 8

11-1HA20

 

 

 

 

 

 

 

0.925

 

1/2

1 1/2

2

3

 

5

7 1/2

65

7…

10

11-1JA20

 

 

 

 

 

 

 

0.925

 

1/2

2

3

3

 

7 1/2

10

65

9…

12.5

11-1KA20

 

 

 

 

 

 

 

0.925

 

1

2

3

5

 

10

--

65

11…

16

21-4AA20

26-2BB40

 

 

 

 

 

 

0.925

 

1 1/2

3

5

5

 

10

--

65

14…

20

21-4BA20

 

 

 

 

 

 

 

0.925

 

1 1/2

3

5

7 1/2

 

15

--

50

17…

22

21-4CA20

27-2BB40

 

 

 

 

 

 

0.925

 

2

3

5

7 1/2

 

15

--

50

20…

25

21-4DA20

 

 

 

 

 

 

 

0.925

 

2

5

7 1/2

10

 

20

--

50

27…

32

21-4EA20

 

 

 

 

 

 

 

0.925

Screw fixing with 1 push-in lug each per motor starter is possible.

1)For auxiliary switches see Accessories page 6/21.

2)Selection depends on the motor full load amps. HP ratings for reference only.

3)Used only for mounting starter on 8US Fast Bus busbar systems.

4)Mounting on standard mounting rails or with screws (3RA29 22-1AA00) is possible for feeder-orientated assembly, in which case the contactor must be screwed onto the adapter.

6/16

SIRIUS Innovations Supplement 2011

Illustrations are approximate

 

 

 

© Siemens AG 2011

Combination Starters & Starters for Group Installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIRIUS 3RA2 Motor Starters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3RA22 reversing starters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50/60 Hz 110/120 V AC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selection and ordering data

 

 

 

 

Reversing duty

Rated control supply voltage 50/60 Hz 110/120 V AC

 

 

With screw connections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• The motor starter protector and contactor are mechan-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ically and electrically connected by means of the link

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

module.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Auxiliary switches1) on the motor starter protector and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the contactor can be easily fitted due to the modular

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

system.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• With the contactor S0, an integrated NO contact is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

available for free use.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combination Starter, UL508 Type F

 

 

 

 

 

3RA22 10

3RA22 20

3RA22 10

3RA22 20

 

 

 

All size S00 and S0 devices can be applied as Combina-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tion Starters with the addition of either of these line side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connectors: 3RV29 28-1H, 3RV29 25-5EB or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3RV29 28-1K.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Size

UL Data

 

 

 

 

 

 

FLA setting

Consisting of the following single devices

 

Assembled starter

Weight

 

 

 

 

 

 

 

 

 

range inverse-

 

 

 

 

 

 

 

 

 

 

 

approx.

 

 

 

 

2)

 

 

 

time delayed

 

 

 

 

 

 

 

 

 

 

 

 

 

Single-phase

Three-phase

 

 

SCCR

overload

Motor starter

+ 2 contac-

+ Link module

 

Screw terminals

 

 

 

 

HP ratings

HP ratings

 

 

at

protector

tors

+ Assembly kit

 

 

 

 

 

 

 

 

 

 

 

 

release

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

480 V

 

 

RH/RS3)

 

 

 

 

 

 

 

 

 

 

115 V

230 V

200 V

230 V

 

460 V

575 V

 

 

 

 

 

 

 

 

 

 

 

 

Order No.

 

 

 

 

 

 

 

 

 

 

 

 

 

kA

A

 

 

 

 

 

 

 

 

 

 

 

 

 

kg

Selection depends on motor full load amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3RV20

3RT20

3RA

 

 

 

 

 

 

 

 

 

S00

--

--

--

--

 

--

--

65

0.14…0.2

11-0BA10

15-1AK62

1921-1DA00

 

3RA22 10-0B@15-2AK6

0.824

 

--

--

--

--

 

--

--

65

0.18…0.25

11-0CA10

 

+ 2913-2AA14)

 

3RA22 10-0C@15-2AK6

0.824

 

--

--

--

--

 

--

--

65

0.22…0.32

11-0DA10

 

+ 2913-1DB1 (RS)

 

 

 

 

0.824

 

 

 

 

3RA22 10-0D@15-2AK6

 

--

--

--

--

 

--

--

65

0.28…0.4

11-0EA10

 

 

 

 

 

 

0.824

 

 

 

 

 

3RA22 10-0E@15-2AK6

 

--

--

--

--

 

--

--

65

0.35…0.5

11-0FA10

 

 

 

3RA22 10-0F@15-2AK6

0.824

 

--

--

--

--

 

--

--

65

0.45…0.63

11-0GA10

 

 

 

 

 

 

0.824

 

 

 

 

 

3RA22 10-0G@15-2AK6

 

--

--

--

--

 

--

--

65

0.55…0.8

11-0HA10

 

 

 

 

 

 

0.824

 

 

 

 

 

3RA22 10-0H@15-2AK6

 

--

--

--

--

 

--

1/2

65

0.7…

1

11-0JA10

 

 

 

3RA22 10-0J@15-2AK6

0.824

 

--

--

--

--

 

1/2

1/2

65

0.9…

1.25

11-0KA10

 

 

 

3RA22 10-0K@15-2AK6

0.824

 

--

1/10

--

--

 

3/4

3/4

65

1.1…

1.6

11-1AA10

 

 

 

 

 

 

0.824

 

 

 

 

 

3RA22 10-1A@15-2AK6

 

--

1/8

--

--

 

3/4

1

65

1.4…

2

11-1BA10

 

 

 

3RA22 10-1B@15-2AK6

0.824

 

--

1/6

1/2

1/2

 

1

1 1/2

65

1.8… 2.5

11-1CA10

 

 

 

3RA22 10-1C@15-2AK6

0.824

 

1/10

1/4

1/2

3/4

 

1 1/2

2

65

2.2… 3.2

11-1DA10

 

 

 

 

 

 

0.824

 

 

 

 

 

3RA22 10-1D@15-2AK6

 

1/8

1/3

3/4

3/4

 

2

3

65

2.8… 4

11-1EA10

 

 

 

 

 

 

0.824

 

 

 

 

 

3RA22 10-1E@15-2AK6

 

1/6

1/2

1

1

 

3

3

65

3.5… 5

11-1FA10

 

 

 

 

 

 

0.824

 

 

 

 

 

3RA22 10-1F@15-2AK6

 

1/4

1/2

1

1 1/2

 

3

5

65

4.5… 6.3

11-1GA10

 

 

 

3RA22 10-1G@15-2AK6

0.824

 

1/3

1

2

2

 

5

5

65

5.5… 8

11-1HA10

16-1AK62

 

 

 

 

 

0.824

 

 

 

 

3RA22 10-1H@16-2AK6

 

1/2

1 1/2

2

3

 

5

7 1/2

65

7… 10

11-1JA10

 

 

 

 

 

 

0.824

 

 

 

 

 

3RA22 10-1J@16-2AK6

 

1/2

2

3

3

 

7 1/2

10

65

9… 12

11-1KA10

17-1AK62

 

 

3RA22 10-1K@17-2AK6

0.824

 

1

2

3

5

 

10

--

65

11… 16

11-4AA10

18-1AK62

 

 

3RA22 10-4A@18-2AK6

0.824

S0

1/6

1/2

1

1

 

3

3

65

3.5… 5

11-1FA10

24-1AK60

2921-1AA00

 

3RA22 20-1F@24-0AK6

1.434

 

1/4

1/2

1

1 1/2

 

3

5

65

4.5… 6.3

11-1GA10

 

+ 2923-1BB1 (RH)

 

3RA22 20-1G@24-0AK6

1.434

 

1/3

1

2

2

 

5

5

65

5.5… 8

11-1HA10

 

+ 2923-1DB1 (RS)

 

3RA22 20-1H@24-0AK6

1.434

 

1/2

1 1/2

2

3

 

5

7 1/2

65

7…

10

11-1JA10

 

 

 

 

 

 

1.434

 

 

 

 

 

3RA22 20-1J@24-0AK6

 

1/2

2

3

3

 

7 1/2

10

65

9…

12.5

11-1KA10

 

 

 

 

 

 

1.434

 

 

 

 

 

3RA22 20-1K@24-0AK6

 

1

2

3

5

 

10

--

65

11… 16

21-4AA10

26-1AK60

 

 

3RA22 20-4A@26-0AK6

1.434

 

1 1/2

3

5

5

 

10

--

65

14… 20

21-4BA10

 

 

 

 

 

 

1.434

 

 

 

 

 

3RA22 20-4B@26-0AK6

 

1 1/2

3

5

7 1/2

 

15

--

50

17… 22

21-4CA10

27-1AK60

 

 

 

 

 

1.434

 

 

 

 

3RA22 20-4C@27-0AK6

 

2

3

5

7 1/2

 

15

--

50

20… 25

21-4DA10

 

 

 

3RA22 20-4D@27-0AK6

1.434

 

2

5

7 1/2

10

 

20

--

50

27… 32

21-4EA10

 

 

 

3RA22 20-4E@27-0AK6

1.434

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Add. weight

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Order No. supplement for mounting onto standard mounting rail or screw fixing

 

 

 

 

 

 

 

 

 

 

 

• Without standard mounting rail adapter for size S004)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

A

 

 

 

 

• With 2 standard mounting rail adapters for size S0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

B

 

 

 

 

Screw fixing with 2 push-in lugs each per motor starter is possible

 

 

 

 

 

 

 

 

 

 

 

 

Order No. supplement for mounting onto 60 mm busbar

 

 

 

 

for size S00

 

 

1

 

D

 

 

 

0.486

With 8US Fast Bus busbar adapter

 

 

 

 

 

 

 

 

 

 

 

 

 

for size S0

 

 

2

 

D

 

 

 

0.293

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)For push-in lugs and auxiliary switches see Accessories.

2)Selection depends on the motor full load amps. HP ratings for reference only.

3)According to ordering option:

RH = assembly kit for reversing duty with standard rail mounting adapter in size S0.

RS = assembly kit for reversing duty with 8US Fast Bus busbar mounting.

4)With standard rail mounting or screw fixing, the 3RA29 13-2AA1 wiring kit is required for size S00.

6

Illustrations are approximate

SIRIUS Innovations Supplement 2011

6/17

 

 

 

6

© Siemens AG 2011

Combination Starters & Starters for Group Installation

SIRIUS 3RA2 Motor Starters

3RA22 reversing starters 50/60 Hz 110/120 V AC

 

 

 

 

Reversing duty

Rated control supply voltage 50/60 Hz 110/120 V AC

 

 

 

 

With spring-type connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• These starters can be assembled in the field without

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tools by simply snapping the components together.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Follow the simple component selection system to form

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a starter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Auxiliary switches1) on the motor starter protector and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the contactor can be easily fitted due to the modular

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

system.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• With the contactor S0, an integrated NO contact is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

available for free use.

3RA22 10

3RA22 20

3RA22 10

3RA22 20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combination Starter, UL508 Type F

All size S00 and S0 devices can be applied as Combination Starters with the addition of either of these line side connectors: 3RV29 28-1H, 3RV29 25-5EB or

3RV29 28-1K.

Size

UL Data

 

 

 

 

 

FLA set-

 

 

 

 

 

 

 

 

ting range

 

Single-phase

2)

 

SCCR

inverse-

 

 

 

Three-phase

 

time

 

HP ratings

HP ratings

 

at

delayed

 

 

 

 

 

 

 

480 V

 

 

 

 

 

 

 

 

overload

 

 

 

 

 

 

 

 

release

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115 V

230 V

200 V

230 V

460 V

575 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kA

A

Consisting of the following single devices

Not available

Weight

 

 

 

 

 

pre-assembled

approx.

Motor

+ 2 contac-

Standard rail

8US Busbar

 

Spring-type

 

 

 

starter

tors

or screw

mounting

 

terminals

 

 

 

protector

 

mounting

system

 

 

 

 

 

 

 

+ Link module

+ Link module

 

 

 

 

 

 

 

+ Assembly kit

+ Assembly kit

 

 

 

 

 

 

 

(RH)3)

(RS)3)

 

 

 

 

 

 

 

 

 

 

Order No.

 

 

 

 

 

 

 

 

 

kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selection depends on motor full load amps

 

 

 

 

 

 

 

 

 

 

3RV20

3RT20

3RA

3RA

 

S00

--

--

--

--

--

--

65

0.14…0.2

11-0BA20

15-2AK62

2911-2AA00

2911-2AA00

0.641

 

--

--

--

--

--

--

65

0.18…0.25

11-0CA20

 

+ 2913-2AA24)

+ 2913-1DB25)

0.641

 

--

--

--

--

--

--

65

0.22…0.32

11-0DA20

 

 

 

0.641

 

--

--

--

--

--

--

65

0.28…0.4

11-0EA20

 

 

 

0.641

 

--

--

--

--

--

--

65

0.35…0.5

11-0FA20

 

 

 

0.641

 

--

--

--

--

--

--

65

0.45…0.63

11-0GA20

 

 

 

0.641

 

--

--

--

--

--

--

65

0.55…0.8

11-0HA20

 

 

 

0.641

 

--

--

--

--

--

1/2

65

0.7…

1

11-0JA20

 

 

 

0.641

 

--

--

--

--

1/2

1/2

65

0.9…

1.25

11-0KA20

 

 

 

0.641

 

--

1/10

--

--

3/4

3/4

65

1.1…

1.6

11-1AA20

 

 

 

0.641

 

--

1/8

--

--

3/4

1

65

1.4…

2

11-1BA20

 

 

 

0.641

 

--

1/6

1/2

1/2

1

1 1/2

65

1.8… 2.5

11-1CA20

 

 

 

0.641

 

1/10

1/4

1/2

3/4

1 1/2

2

65

2.2… 3.2

11-1DA20

 

 

 

0.641

 

1/8

1/3

3/4

3/4

2

3

65

2.8… 4

11-1EA20

 

 

 

0.641

 

1/6

1/2

1

1

3

3

65

3.5… 5

11-1FA20

 

 

 

0.641

 

1/4

1/2

1

1 1/2

3

5

65

4.5… 6.3

11-1GA20

 

 

 

0.641

 

1/3

1

2

2

5

5

65

5.5… 8

11-1HA20

16-2AK62

 

 

0.641

 

1/2

1 1/2

2

3

5

7 1/2

65

7… 10

11-1JA20

 

 

 

0.641

 

1/2

2

3

3

7 1/2

10

65

9… 12

11-1KA20

17-1AK62

 

 

0.641

 

1

2

3

5

10

--

65

11…

16

11-4AA20

18-2AK62

 

 

0.641

S0

1/6

1/2

1

1

3

3

65

3.5… 5

11-1FA20

24-2AK60

2921-2AA00

2921-2AA00

0.925

 

1/4

1/2

1

1 1/2

3

5

65

4.5… 6.3

11-1GA20

 

+ 2923-1BB25)

+ 2923-1DB25)

0.925

 

1/3

1

2

2

5

5

65

5.5… 8

11-1HA20

 

 

 

0.925

 

1/2

1 1/2

2

3

5

7 1/2

65

7…

10

11-1JA20

 

 

 

0.925

 

1/2

2

3

3

7 1/2

10

65

9…

12.5

11-1KA20

 

 

 

0.925

 

1

2

3

5

10

--

65

11…

16

21-4AA20

26-2AK60

 

 

0.925

 

1 1/2

3

5

5

10

--

65

14…

20

21-4BA20

 

 

 

0.925

 

1 1/2

3

5

7 1/2

15

--

50

17…

22

21-4CA20

27-2AK60

 

 

0.925

 

2

3

5

7 1/2

15

--

50

20…

25

21-4DA20

 

 

 

0.925

 

2

5

7 1/2

10

20

--

50

27…

32

21-4EA20

 

 

 

0.925

Screw fixing with 2 push-in lugs each per motor starter is possible with RH configured starters. (see "Accessories for Direct-On-Line and Reversing Starters").

1)For push-in lugs and auxiliary switches see Accessories.

2)Selection depends on the motor full load amps. HP ratings for reference only.

3)Code for abbreviations:

RH = assembly kit for reversing duty and standard rail mounting adapter in size S0.

RS = assembly kit for reversing duty and busbar mounting.

4)With standard rail mounting or screw fixing, the 3RA29 13-2AA2 wiring kit and link module are required for size S00.

5)The RH/RS assembly kits also include 3RA29 11-1CA00 spacer for height compensation on AC contactors size S0 with spring-type terminals.

6/18

SIRIUS Innovations Supplement 2011

Illustrations are approximate

 

 

 

Loading...