SIMATIC PC
Panel PC 670
Computing Unit
Equipment Manual
This manual is only valid for computing units
with Order No. 6AV77xx-...
Preface, Contents
Product Overview |
1 |
|
|
|
|
Starting Up the |
2 |
|
Computing Unit |
||
|
|
|
Connecting and Switching on the |
3 |
|
Computing Unit |
||
|
|
|
Maintaining and Extending the |
4 |
|
Computing Unit |
||
|
|
|
Configuring the Computing Unit |
5 |
|
in BIOS Setup |
||
|
|
|
Fault Diagnosis |
6 |
|
|
|
|
Hardware Information |
7 |
|
|
|
|
Distributed Configuration |
8 |
A
Appendices
C
Glossary, Index
Release 04/02
Safety Guidelines
This manual contains notices which you should observe to ensure your own personal safety, as well as to protect the product and connected equipment. These notices are marked as follows according to the level of danger:
Danger
!indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Warning
!indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Caution
!used with the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
Caution
used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.
Notice
indicates that unwanted events or status can occur if the relevant information is not observed.
Note
draws your attention to particularly important information on the product, handling the product, or to a particular part of the documentation.
Qualified Personnel
Equipment may be commissioned and operated only by qualified personnel. Qualified personnel within the meaning of the safety notices in this manual are persons who are authorized to commission, ground and identify equipment, systems and circuits in accordance with safety engeneering standards.
Correct Usage
Please note the following:
Warning
!The device may only be used for the application cases specified in the catalog and the technical description and may only be used in combination with third-party equipment and components recommended or approved by Siemens.
Appropriate transport, and appropriate storage, installation and assembly, as well as careful operation and maintenance, are required to ensure that the product operates perfectly and safely.
Trademarks
The registered trademarks of the Siemens AG can be found in the preface.
Impressum
Editor and Publisher: A&D PT1
Copyright Siemens AG 2002 Allrights reserved
The transmission and reproduction of this documentation and the exploitation and communication of its contents are not permitted without express authority. Offenders will be liable for compensation for damage. All rights reserved, especially in the case of the granting of a patent or registration of a utility model or design
Siemens AG
Bereich Automation & Drives
Geschäftsgebiet SIMATIC HMI
Postfach 4848, D-90327 Nürnberg
Exclusion of Liability
We have checked the content of this publication for compliance with the described hardware and software. However, discrepancies cannot be excluded, with the result that we cannot guarantee total compliance. The information in this publication is, however, checked regularly, and any necessary corrections are included in the following editions. We welcome any suggestions for improvement.
E Siemens AG 2002
Technical data subject to change.
Siemens Aktiengesellschaft |
Release 04/02 |
For your notes
Purpose
The SIMATIC Panel PC 670 Computing Unit equipment manual is part of the SIMATIC HMI documentation.
It provides information for operators, mechanics, project engineers and maintenance personnel about the computing unit’s installation, functionality, operation and technical structure.
Documentation
SSIMATIC Panel PC 670, Computing Unit Equipment Manual (this document) SIMATIC Panel PC 870, Computing Unit Equipment Manual
The equipment manual contains information on extension options for the computing unit, on the configuration, error diagnostics and the hardware.
SSIMATIC Panel PC 670/870 Operating Unit Equipment Manual
The equipment manual contains information on operating the operating unit, error diagnostics and the hardware.
SSIMATIC Panel PC 670/870, Installation Guide
This Installation Guide contains the information on the mechanical and electrical installation of the Panel PC 670/870 and starting it up.
All the equipment manuals mentioned are supplied with the Panel PC 670/870 electronically in PDF format on the Documentation & Drivers CD and are available in German, English, French, Italian and Spanish.
Target groups include installation engineers as well as service and maintenance technicians.
Panel PC 670 Computing Unit, Equipment Manual |
v |
Preface |
Release 04/02 |
|
|
|
|
Notation
The following conventions are used in this manual:
Motor on |
Text that is displayed on the operating unit is printed in |
|
Courier type face. |
Variable |
Symbolic names that stand for variable quantities that |
|
appear on the screen are printed in Courier italic type face. |
Screens |
Selectable functions are printed in italic type face. |
ESC |
Names of keys and buttons are shown in a different type |
|
face. |
History
Release |
Comments |
|
|
03/00 Initial release of the SIMATIC Panel PC 670 – Computing Unit equipment manual.
12/01 Extension to include ”Remote mount form factor” option of the SIMATIC Panel PC 670 – Computing Unit equipment manual.
04/02 Technical update to the SIMATIC Panel PC 670 Computing Unit equipment manual
Trademarks
The following designations are registered trademarks of Siemens AG:
SSIMATICR
SSIMATIC HMIR
SSIMATIC Multi PanelR
SSIMATIC Multifunctional PlatformR
SSIMATIC Panel PCR
SHMIR
SProToolR
SProTool/LiteR
SProTool/ProR
SMP 270R
SProAgentR
vi |
Panel PC 670 Computing Unit, Equipment Manual |
Release 04/02 |
Preface |
Automation and Drives, Service & Support
Available round the clock, worldwide:
Nuremberg
Johnson City
Singapore
|
|
|
SIMATIC Hotline |
|
|
Worldwide (Nuremberg) |
Worldwide (Nuremberg) |
|
|
||
Technical Support |
Technical Support |
|
|
||
(FreeContact) |
(fee-based, only with SIMATIC |
|
|
||
|
|
Card) |
|
|
|
Local time: Mon.-Fri. 8:00 to 17:00 |
Local time: Mon.-Fri. 0:00 to 24:00 |
|
|
||
Telephone: +49 (180) 5050-222 |
Telephone: +49 (911) 895-7777 |
|
|
||
Fax: |
+49 (180) 5050-223 |
Fax: |
+49 (911) 895-7001 |
|
|
E-Mail: |
techsupport@ |
GMT: |
+01:00 |
|
|
|
ad.siemens.de |
|
|
|
|
GMT: |
+1:00 |
|
|
|
|
Europe / Africa (Nuremberg) |
America (Johnson City) |
Asia / Australia (Singapore) |
|||
Authorization |
Technical Support and |
Technical Support and |
|||
|
|
Authorization |
Authorization |
||
Local time: Mon.-Fri. 8:00 to 17:00 |
Local time: Mon.-Fri. 8:00 to 19:00 |
Local time: Mon.-Fri. 8:30 to 17:30 |
|||
Telephone: +49 (911) 895-7200 |
Telephone: +1 423 461-2522 |
Telephone: +65 740-7000 |
|||
Fax: |
+49 (911) 895-7201 |
Fax: |
+1 423 461-2289 |
Fax: |
+65 740-7001 |
E-Mail: |
authorization@ |
E-Mail: |
simatic.hotline@ |
E-Mail: |
simatic.hotline@ |
|
nbgm.siemens.de |
|
sea.siemens.com |
|
sae.siemens.com.sg |
GMT: |
+1:00 |
GMT: |
–5:00 |
GMT: |
+8:00 |
The languages spoken by the SIMATIC Hotlines are generally German and English, the Authorization Hotline is also provided in French, Italian and Spanish.
Panel PC 670 Computing Unit, Equipment Manual |
vii |
Preface |
Release 04/02 |
|
|
|
|
SIMATIC Customer Support Online Services
The SIMATIC Customer Support team offers you substantial additional information about SIMATIC products via its online services:
SGeneral current information can be obtained
–in the Internet unter http://www.siemens.com/simatic
SCurrent Product Information leaflets, FAQs (Frequently Asked Questions), Downloads, Tips and Tricks can be obtained
–in the Internet under http://www.siemens.com/automation/service&support
Training Center
Siemens offers a number of training courses to familiarize you with the SIMATIC S7 automation system. Please contact your regional training center or our central training center in D 90327 Nuremberg, Germany for details.
Telephone: |
+49 (911) 895–3200 |
Internet: http://www.sitrain.com
E-Mail: info@sitrain.com
Other Sources of Assistance
In case of technical queries, please contact the Siemens representatives in the subsidiaries and branches responsible for your area.
The addresses can be found:
Sin the Siemens Catalogue ST 80
Sin the Internet under http://www.siemens.com/automation/partner
Sin the Interactive Catalogue CA01 http://www.siemens.com/automation/ca01
viii |
Panel PC 670 Computing Unit, Equipment Manual |
1 |
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
1-1 |
|
|
1.1 |
Advantages of the Computing Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
1-2 |
|
1.2 |
Safety Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
1-4 |
|
1.3 |
Certificates, Guidelines and Declarations . . . . . . . . . . . . . . . . . . . . . . . . . . . |
1-8 |
|
1.4 |
Certification for USA, Canada and Australia . . . . . . . . . . . . . . . . . . . . . . . . . |
1-10 |
2 |
Starting Up the Computing Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-1 |
|
|
2.1 |
Unpacking and Checking the Computing Unit . . . . . . . . . . . . . . . . . . . . . . . |
2-2 |
|
2.2 |
Installing the Computing Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-3 |
|
2.3 |
Ensuring Readiness for Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-7 |
|
2.4 |
Transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2-9 |
3 |
Connecting and Switching on the Computing Unit . . . . . . . . . . . . . . . . . . . . . . . . |
3-1 |
|
|
3.1 |
View of Interface Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
3-2 |
|
3.2 |
View of Drive Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
3-5 |
|
3.3 |
Connecting Periphery Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
3-6 |
|
3.4 |
Working with PC Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
3-10 |
3.5 Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 3.5.1 Floppy disk drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 3.5.2 LS240 drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 3.5.3 Hard disk drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
3.5.4CD-ROM drive or CD RW/DVD drive (depending on unit equipment) . . . 3-16
|
3.6 |
Backup Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
3-17 |
|
3.7 |
Using the Computing Unit in a SIMATIC S5 Network . . . . . . . . . . . . . . . . . |
3-18 |
|
3.8 |
Using the Computing Unit in a SIMATIC S7 Network (MPI/DP) . . . . . . . . |
3-22 |
|
3.9 |
Networking the Computing Unit and Other Nodes via PROFIBUS . . . . . . |
3-24 |
|
3.10 |
Networking Computing Unit and Other Computers via Industrial Ethernet |
3-25 |
|
3.11 |
Connection Using Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
3-25 |
4 |
Maintaining and Extending the Computing Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-1 |
|
|
4.1 |
Opening the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-2 |
|
4.1.1 |
Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-2 |
|
4.1.2 |
Opening the computing unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-4 |
|
4.1.3 |
Functional Units Visible After Opening the Device . . . . . . . . . . . . . . . . . . . . |
4-5 |
|
4.1.4 |
Motherboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-6 |
Panel PC 670 Computing Unit, Equipment Manual |
ix |
Contents |
Release 04/02 |
|
|
|
|
|
4.2 |
Installation of a Memory Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-8 |
|
4.3 |
Replacing the Backup Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-10 |
|
4.4 |
Installation of Extension Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-12 |
|
4.4.1 |
Removing and installing the module retainer plates . . . . . . . . . . . . . . . . . . |
4-14 |
|
4.4.2 |
Removing and installing an ISA/PCI module . . . . . . . . . . . . . . . . . . . . . . . . |
4-16 |
|
4.5 |
Removing and Installing Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-17 |
|
4.5.1 |
Removing and installing the hard disk drive . . . . . . . . . . . . . . . . . . . . . . . . . |
4-17 |
|
4.5.2 |
Removing and installing a CD-ROM drive . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-19 |
|
4.5.3 |
Removing and installing the disk drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-20 |
|
4.5.4 |
Removing and installing the LS 240 drive . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-21 |
|
4.6 |
Removing and Installing the Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-22 |
|
4.7 |
Removing and Installing the Bus Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-23 |
|
4.8 |
Removing and Installing the Motherboard . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-24 |
|
4.9 |
Removing and Installing the Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-25 |
|
4.10 |
Processor Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-26 |
|
4.11 |
Reset button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4-27 |
5 |
Configuring the Computing Unit in BIOS Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . |
5-1 |
|
|
5.1 |
Modifying the Device Configuration with SETUP . . . . . . . . . . . . . . . . . . . . . |
5-2 |
|
5.1.1 |
Menu Main . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
5-5 |
|
5.1.2 |
Menü Advanced . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
5-15 |
|
5.1.3 |
Menü Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
5-22 |
|
5.1.4 |
Menu Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
5-24 |
|
5.1.5 |
Menu Boot-Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
5-25 |
|
5.1.6 |
Menu Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
5-27 |
|
5.1.7 |
Menu Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
5-28 |
|
5.1.8 |
Setup default settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
5-29 |
|
5.2 |
Configure PC-Card interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
5-32 |
6 |
Fault Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
6-1 |
|
|
6.1 |
Problems Using External Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
6-2 |
|
6.2 |
External Screen Remains Dark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
6-3 |
|
6.3 |
Display on the External Screen Does Not Appear or Scrolls . . . . . . . . . . . |
6-4 |
|
6.4 |
No Mouse Pointer Appears on the Screen/Display . . . . . . . . . . . . . . . . . . . |
6-4 |
|
6.5 |
Computing Unit Time and/or Date are Not Correct . . . . . . . . . . . . . . . . . . . |
6-5 |
|
6.6 |
USB Device Does Not Work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
6-5 |
|
6.7 |
Error Message Appears on the Screen/Display . . . . . . . . . . . . . . . . . . . . . . |
6-6 |
|
6.8 |
Computing Unit Self-Test Prior to Booting . . . . . . . . . . . . . . . . . . . . . . . . . . . |
6-8 |
7 |
Hardware Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-1 |
|
|
7.1 |
Power Consumption of the Components (Maximum Values) . . . . . . . . . . . |
7-2 |
|
7.2 |
Overview of the Components and Interfaces . . . . . . . . . . . . . . . . . . . . . . . . |
7-3 |
|
7.3 |
System Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-5 |
x |
Panel PC 670 Computing Unit, Equipment Manual |
Release 04/02 |
Contents |
|
7.4 |
Monitoring Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-6 |
|
7.4.1 |
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-6 |
|
7.4.2 |
Signals on the front interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-6 |
|
7.4.3 |
Temperature monitoring/display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-7 |
|
7.4.4 |
Watchdog (WD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-8 |
|
7.4.5 |
Fan monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-9 |
|
7.5 |
Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-10 |
|
7.5.1 |
External interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-10 |
|
7.5.2 |
Interface allocation for connecting a front on the main board . . . . . . . . . . |
7-19 |
|
7.5.3 |
Assignment of internal interfaces on the mainboard . . . . . . . . . . . . . . . . . . |
7-24 |
|
7.6 |
Wiring Backplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-32 |
|
7.6.1 |
Design and Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-32 |
|
7.6.2 |
Pin assignmentI SA slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-32 |
|
7.6.3 |
Pin assignment PCI slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-34 |
|
7.7 |
Power supply (AC and DC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-37 |
|
7.8 |
Connecting cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7-38 |
8 |
Distributed configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
8-1 |
|
|
8.1 |
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
8-2 |
|
8.1.1 |
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
8-2 |
|
8.1.2 |
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
8-3 |
|
8.1.3 |
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
8-3 |
|
8.2 |
Cable connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
8-4 |
|
8.3 |
Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
8-4 |
|
8.4 |
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
8-4 |
A |
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
A-1 |
|
|
A.1 |
Technical Data of the Panel PC 670 Computing Unit . . . . . . . . . . . . . . . . . |
A-2 |
B |
ESD Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
B-1 |
|
|
B.1 |
What does ESD mean? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
B-2 |
|
B.2 |
Electrostatic Charge of People . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
B-3 |
|
B.3 |
Basic Safety Measures against Discharge of Static Electricity . . . . . . . . . |
B-4 |
C SIMATIC HMI Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glossary-1
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Index-1
Panel PC 670 Computing Unit, Equipment Manual |
xi |
Contents |
Release 04/02 |
xii |
Panel PC 670 Computing Unit, Equipment Manual |
Product Overview |
1 |
Chapter Overview
In Section |
You Will Find |
on Page |
|
|
|
1.1 |
Advantages of the computing unit |
1-2 |
|
|
|
1.2 |
Safety notes |
1-4 |
|
|
|
1.3 |
Certificates, guidelines and declarations |
1-8 |
|
|
|
1.4 |
Certification for USA, Canada and Australia |
1-10 |
|
|
|
Panel PC 670 Computing Unit, Equipment Manual |
1-1 |
Product Overview |
Release 04/02 |
|
|
|
|
Computing unit
The computing unit serves as a basic component for the PC-based HMI devices (Panel PC) and, within the scope of special configurations, as a basis for customized devices.
The computing unit is intended for use in industry as well as in the residential, business and commercial areas and can also be used in building system automation or in public facilities, in addition to industrial applications.
Quality
The computing unit is characterized by its high quality, which is attributable, for example, by:
Sextensive climate, vibration and shock tests to ensure industrial compatibility;
Shotline, service, spare parts;
Scompact dimensions;
Ssuitability for use in a wide ambient temperature range;
Sa design that is easy to service and maintain.
Installation
The computing unit can be installed in virtually all the usual locations (refer to Chapter 2.2).
There are anchorage points on both of the longs sides for securing the computing unit. Mounting brackets are screwed onto these anchorage points.
Constructional designs
The SIMATIC Panel PC 670/870 is available in two different designs:
1.Panel PC in a centralized design (computing unit and operating unit are integrated),
2.or as a Panel PC in decentralized design (computing unit and operating unit spatially separated, refer to Chapter 8).
1-2 |
Panel PC 670 Computing Unit, Equipment Manual |
Release 04/02 |
Product Overview |
Software equipment
The computing unit is equipped with software which allows it to be used universally. It contains the operating system Windows NT 4.0, Windows 98 or Windows 2000.
The computing unit additionally allows the use of:
SSIMATIC supplementary software
Ssoftware from the entire world of automation
Ssoftware from the PC world
Advantages of the computing unit
SThe computing unit is rugged in design and its functions make it particularly suitable for use on site under harsh industrial conditions. It meets the specific requirements of an industrial environment, such as noise immunity, compliance with standards, ruggedness and continuous operation.
SOwing to the variable operating location and the many options for installation, the computing unit can be used virtually anywhere.
SIntegrated on the computing unit are all the ports required for SIMATIC automation. Specifically, these are:
–parallel port (LPT1)
–serial ports (1x V.24, 1x V.24/TTY)
–PS/2 keyboard interface
–PS/2 mouse port
–USB interface (2x computing unit, 1x operating unit)
–MPI/L2-DP (max. 12 Mbit/s)
–Cardbus interface, 1 slot (type I/II/III)
–VGA interface for external monitor
–LVDS interface for flat-screen display
Panel PC 670 Computing Unit, Equipment Manual |
1-3 |
Product Overview |
Release 04/02 |
|
|
|
|
Caution
!Please observe the safety notes on the back of the cover of this manual. Expansions to the Panel PC should only be carried out after having read Chapter 4 and the relevant safety notes.
This device complies with the safety requirements in accordance with IEC, VDE, EN, UL and CSA. If you have doubts about the approval of the installation in the intended location, please contact the service representative responsible for your area.
Notes on installation
If the device is brought to its operating location from a cold environment, condensation may occur. Before starting up, the device must be dry and, therefore, an acclimatization period of at least 12 hours is necessary.
Before installing and operating the device, please note the information on ambient conditions in the Appendix Technical Data and and on installing the device in Chapter 2.2. The device must be installed in such a way that it presents no danger of any kind (for example, by tipping over).
Ensure that the air vents are not obstructed and sufficient cooling air can be drawn in inside the device.
Warning
!When assembling the systems, it is essential to maintain the permissible installation positions and angles (refer to Chapter 2.2).
If systems are installed at a non-approved installation location, the approvals to UL 1950, UL 508 and EN60950 are no longer valid!
1-4 |
Panel PC 670 Computing Unit, Equipment Manual |
Release 04/02 |
Product Overview |
Mains supply
When connecting the device, observe the relevant information provided in Chapter 2.
Never connect or disconnect power cables or data transmission lines during a thunderstorm.
In an emergency situation (for instance, damage to the housing, controls or power cable, penetration by liquids or foreign bodies), pull the power plug and contact the authorized service department.
When plugging in/out periphery connections (e.g. keyboard, mouse, printer), the SIMATIC Panel PC must have been switched off (not in the case of PC card and USB devices). Failure to do so can result in damage to the computing unit.
Notes for devices with AC power supply
The device is intended for connection to grounded power supply systems (TN networks to VDE 0100, Part 300, or IEC 364-3).
No provision is made for connection to non-grounded or impedance-grounded power supply systems (IT networks).
The power cable should comply with the safety guidelines of the country concerned.
Check to make sure that the rated voltage for the device corresponds to that supplied by the local power supply.
This device is equipped with a safety-tested power supply cable and may be connected only to a socket outlet with grounding contact.
Make sure that the socket outlet on the device or the socket outlet with grounding contact of the building wiring system is freely accessible and located as near to the device as possible.
To completely disconnect the PC from the mains power supply, you must pull the plug. This connection must be easily accessible. If the PC is to be installed in a cabinet, a central disconnector must be provided.
Note for devices with DC power supply
Devices with a DC power supply are considered open operating resources (right side of device); therefore, the assembly design must fulfill the fire protection housing requirements.
Warning
!The device may only be connected to 24 V DC power supply networks which fulfill the requirements of a safe electrical low voltage (SELV).
The cable cross-section must be large enough so that, should a short circuit occur in the computing unit no damage is caused by the cable.
Panel PC 670 Computing Unit, Equipment Manual |
1-5 |
Product Overview |
Release 04/02 |
|
|
|
|
Country-Specific Notes
For the USA and Canada:
For operation in Canada and the United States, use CSA or UL-listed power cables.
The connector must comply with the NEMA 5-15 specification.
120 V power supply
A flexible cable with UL approval and CSA marking and the following features must be used: SJT design with three conductors, at least 18 AWG cross-section, a maximum length of 4.5 meters and parallel grounding-type plug (15 A, at least
125 V).
240 V power supply
A flexible cable with UL approval and CSA marking and the following features must be used: SJT design with three conductors, at least 18 AWG cross-section, a maximum length of 4.5 meters and Tandem grounding-type plug (15 A, at least 250 V).
230 V supply voltage outside the USA and Canada
A flexible cable with the following features must be used: conductor cross section at least 18 to AWG and grounding-type plug 15 A / 250 V. Make sure that the cable set complies with the safety standards of the country where the devices will be installed and that they bear the relevant markings.
Repairs
Repairs to the Panel PC may only be carried out by authorized, adequately trained personnel.
Warning
!Unauthorized opening and repairs to devices can lead to severe property damage or represent a danger to the user.
Always unplug the power plug before opening the unit.
Only install system extensions which are intended for the computer. The installation of other expansions can damage the system or violate safety and radio interference regulations. Information concerning which extensions are suitable for the system can be obtained from technical service representatives or the sales outlet.
The terms of the warranty are deemed void in the case of defects caused to the Panel PC by the installation or replacement of system extensions.
The power supply may only be removed or replaced by authorized, adequately trained personnel.
1-6 |
Panel PC 670 Computing Unit, Equipment Manual |
Release 04/02 |
Product Overview |
Batteries
This unit contains batteries on the motherboard. The batteries may only be replaced by authorized, adequately trained personnel.
When disposing of the batteries, observe the locally applicable laws on disposal of pollutants.
Caution
!Improper replacement of the battery poses danger of explosion. Only replace with batteries of the same type or those of a similar type recommended by the manufacturer. When disposing of the batteries, observe the locally applicable laws on disposal of pollutants.
ESD guidelines
Components containing ESD (Electrostatically Sensitive Devices) may be identified by the following label:
When handling components containing ESD, it is essential to observe the following guidelines:
SBefore working with components containing ESD, you must discharge any static electricity from your body (e.g. by touching a grounded object).
SAny devices and tools used must also be free of static electricity.
SPull the power plug before connecting or disconnecting components containing ESD.
SOnly touch the components containing ESD at the edges.
SDo not touch any contact pins or strip conductors on components containing ESD.
Panel PC 670 Computing Unit, Equipment Manual |
1-7 |
Product Overview |
Release 04/02 |
|
|
|
|
CE identification
The SIMATIC product described in this manual fulfills the requirements to be awarded the CE identification.
EMC guidelines
Units with Power Supply 105W Power fulfill the requirements of EU Guideline “89/336/EEC Electromagnetic Compatibility” and are designed for use in the following sectors according to the CE identification:
Area of use |
Requirements on |
|
|
|
|
|
Emitted interference |
Noise immunity |
|
|
|
Industrial sector |
EN 50081-2: 1993 |
EN 50082-2: 1995 |
|
|
|
Units with an AC power supply comply with the standards EN 61000-3-2:1995 (harmonic currents) and EN 61000-3-3:1995 (voltage fluctuations and flicker).
Caution
This is Class A equipment. The equipment may cause radio interference in residential areas; in such cases, the operator can be requested to take reasonable countermeasures.
Low voltage guidelines
The devices with AC power supply meet the requirements of
EU Guideline 73/23/EEC ”Low voltage guideline”. Maintenance of this standard was tested according to EN60950.
Declaration of Conformity
The EU Declaration of Conformity and associated documentation complying with the above guideline are kept available for the authorities responsible by :
Siemens AG
Bereich Automation & Drives
A&D AS RD 4
Postfach 1963
D-92209 Amberg
Tel.: +49 (9621) 80-3283
Fax: +49 (9621) 80-3278
1-8 |
Panel PC 670 Computing Unit, Equipment Manual |
Release 04/02 |
Product Overview |
Observe installation guidelines
The installation guidelines and safety notes specified in this manual must be observed when starting up and operating the system.
Connection of periphery devices
The requirements concerning interference immunity are met when periphery equipment suitable for industrial demands, is connected in accordance with EN50082-2:1995. Periphery devices should only be connected using shielded cables.
DIN ISO 9001 certificate
The quality assurance system of our entire product production process (development, production and sales) meets the requirements of DIN ISO 9001 (corresponds to EN29001: 1987).
This was confirmed by the DQS – Deutsche Gesellschaft zur Zertifizierung von Qualitätsmanagementsystemen mbH) – (German quality management system approval authority).
EQ Net Certificate No.: 1323-01
Panel PC 670 Computing Unit, Equipment Manual |
1-9 |
Product Overview |
Release 04/02 |
|
|
|
|
Safety
|
|
If the device bears one of the following marks, the corresponding approval has |
|
|
|
been awarded: |
|
|
|
Underwriters Laboratories (UL) complying with Standard UL 1950 (I.T.E) |
|
|
|
||
|
|
or complying with UL508 (IND.CONT.EQ) |
|
C |
|
Underwriters Laboratories (UL) complying with Canadian Standard C22.2 |
|
|
No. 950 (I.T.E) or complying with C22.2 No. 142 (IND.CONT.EQ) |
||
|
|
Underwriters Laboratories (UL) complying with Standard UL 1950, Report E11 |
|
C |
US |
5352 and Canadian Standard C22.2 No. 950 (I.T.E) |
|
or complying with UL508 and C22.2 No. 142 (IND.CONT.EQ) |
|||
|
|
||
|
|
UL Recognition Mark |
|
|
|
Canadian Standard Association (CSA) complying with Standard C22.2. No. 950 |
|
|
|
(LR 81690) or complying with C22.2 No. 142 (LR 63533) |
|
|
|
Canadian Standard Association (CSA) complying with American Standard UL |
|
|
NRTL |
1950 (LR 81690) or complying with UL 508 (LR 63533) |
|
|
|
||
|
|
|
1-10 |
Panel PC 670 Computing Unit, Equipment Manual |
Release 04/02 |
Product Overview |
EMC
USA
Federal Communications Commission
Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Shielded Cables
Shielded cables must be used with this equipment to maintain compliance with FCC regulations.
Modifications
Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
Conditions of Operations
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Canada
(for devices with power supply 105W)
Canadian Notice
This Class A digital apparatus complies with Canadian ICES-003.
Avis Canadien
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
(for devices with power supply 85W)
Canadian Notice
This Class B digital apparatus complies with Canadian ICES-003.
Avis Canadien
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Panel PC 670 Computing Unit, Equipment Manual |
1-11 |
Product Overview |
Release 04/02 |
|
|
|
|
Australia
This product meets the requirements of the AS/NZS 3548 Norm.
1-12 |
Panel PC 670 Computing Unit, Equipment Manual |
Starting Up the Computing Unit |
2 |
Chapter Overview
In Section |
You Will Find |
on Page |
|
|
|
2.1 |
Unpacking and checking the computing unit |
2-2 |
|
|
|
2.2 |
Installing the computing unit |
2-3 |
|
|
|
2.3 |
Ensuring Readiness for Service |
2-7 |
|
|
|
2.4 |
Transport |
2-9 |
|
|
|
Panel PC 670 Computing Unit, Equipment Manual |
2-1 |
Starting Up the Computing Unit |
Release 04/02 |
|
|
|
|
Unpacking the computing unit
Unpack the item delivered to you as follows:
1.Remove the packaging.
2.Do not throw the original packaging away. Keep it in case you have to transport your PC at some time in the future.
3.Please keep the enclosed documentation in a safe place. You will require it when you first start up the item delivered to you and it is part of the device.
4.Check the packaging and the package contents for any visible damage.
Entering the production number (SVP number)
5.Record the serial number (SDVP number) of your computing unit in the table; you will find it on the rating plate above the floppy disk drive on the side of the device.
The SVP number and MLFB number provide unique identification of the device or repairs or in the case of theft.
Entering the Microsoft Windows “Product Key” of the “Certificate of
Authenticity”
6.Enter the Microsoft Windows ”Product Key” of the ”Certificate of Authenticity” (COA) in the table. The Product Key can be found on the unit on the power supply cover. The Windows Product Key is necessary should the operating system need to be reinstalled.
SVP No.
MLFB No.
Microsoft Windows Product Key
2-2 |
Panel PC 670 Computing Unit, Equipment Manual |
Release 04/02 |
Starting Up the Computing Unit |
The unit delivered is particularly suited for installation in consoles, cabinets and panels.
The computing units with AC power supply meet the requirements of the fire protection housing complying with EN60950. It can therefore be installed without an additional fire enclosure;
The computing units with a DC power supply are considered open operating resources (right side of device); therefore, the assembly design must fulfill the fire protection housing requirements.
Please observe the following points when installing your device:
SAvoid extreme ambient conditions as far as possible. Protect the device from dust, moisture and heat.
SDo not expose your device to direct sunlight.
SThe device must be installed in such a way that it presents no danger of any kind (for example, by tipping over).
SThe clearance around the device must be at least 100 mm to make sure it is sufficiently ventilated.
SNever cover the ventilation slots.
SObserve the installation locations allowed when you install your device.
Warning
!If systems are installed at a non-approved installation location, the approvals to UL 1950 and EN60950 are no longer valid!
Panel PC 670 Computing Unit, Equipment Manual |
2-3 |
Starting Up the Computing Unit |
Release 04/02 |
|
|
|
|
297 |
80 |
267 |
11 |
Figure 2-1 Dimension drawings for installation of the computing unit (device without CD-ROM drive)
The computing unit contains a CD-ROM or CD-RW/DVD drive, depending on the unit version. The installation depth of the computing unit is increased by 21 mm as a result of its installation.
2-4 |
Panel PC 670 Computing Unit, Equipment Manual |
Release 04/02 |
Starting Up the Computing Unit |
Permissible installation positions for the computing unit complying with UL1950/EN60950/CSA22. 2 No. 950
An angle of inclination of ± 20_ is allowed installation position.
|
Position 1 (preferred position) |
Position 2 *) |
|
|
Position 3 (desktop) |
Position 4 (cover) |
**) |
*) |
Not permitted where an LS240 drive is installed. |
|
|
**) Not permitted where a disk/CD-ROM/LS240 drive is installed.
Panel PC 670 Computing Unit, Equipment Manual |
2-5 |
Starting Up the Computing Unit |
Release 04/02 |
|
|
|
|
Additional permissible installation position for the computing unit complying with UL508/CSA 22.2 No. 142
An installation angle of ±15_ is permitted in this position.
Position 5 (interfaces at bottom)
Note
The possible installation locations for the computing unit do not agree with the permissible installation location of Panel PC 670 (refer to the commissioning instructions).
2-6 |
Panel PC 670 Computing Unit, Equipment Manual |