MAMMOMAT 1000/3000
Wiring Diagrams
|
|
|
|
|
|
|
|
|
|
|
|
© Siemens AB 1999 |
||
|
|
The reproduction, transmission or |
||
|
|
use of this document or its contents |
||
|
|
is not permitted without express |
||
|
|
written authority. Offenders will be |
||
|
|
liable for damages. |
All rights, |
|
|
|
including rights created by patent |
||
|
|
grant or registration of a utility |
||
|
|
model _or_ design,_are_ reserved. |
||
|
Register 6 |
English |
|
|
|
Print No.: SPB7-230.051.05.02.02 |
Doc. Gen. Date: |
10.99 |
|
|
Replaces: SPB7-230.051.05.01.02 |
65 27 258 |
|
|
0 - 2 |
|
|
Revision |
|
|
|
|
Chapter |
Page |
Revision |
|
|
|
|
|
1 |
2 |
02 |
|
|
|
|
|
2 |
2, 4-9, 11-12 |
02 |
|
|
|
|
|
3 |
1-2, 11 |
02 |
|
|
|
|
|
5 |
2 |
02 |
|
|
|
|
|
MAMMOMAT 1000/3000 |
Register 6 |
Drucknr_kurz_V |
Page 2 of 4 |
Siemens-Elema AB |
Manual_V |
|
Rev. _V 10.99 |
SPS-UD |
Solna, Sweden |
Contents |
0 - 3 |
|
Page |
This document is valid from serial No. 6500 |
|
1 _______System Overview ______________________________________________ 1 - 1
System Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 1 MAMMOMAT 1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 1 MAMMOMAT 1000 WITH REMOTE CONTROL . . . . . . . . . . . . . . . . . 1 - 2 MAMMOMAT 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 3
2 _______Stand Overview _______________________________________________ |
2 - 1 |
||
Placement of PC-boards and Components, Stand |
. . . . . . . . . . . . . . . . . . 2 - 1 |
||
MAMMOMAT 1000 . . . . . . . . . . . . . . |
. . . . . . . . . . . . . . . . . . 2 - 1 |
||
MAMMOMAT 3000 . . . . . . . . . . . . . . . |
. . . . . . . . . . . . . . . . . . 2 - 2 |
||
List of Boards and Fuses, Stand . . . . . . . . . |
. . . . . . . . . . . . . . . . . . 2 - 4 |
||
PCB Overview . . . . . . . . . . . . . . . . . |
. . . . . . . . . . . . . . . . . . 2 - 4 |
||
Fuses Overview . . . . . . . . . . . . . . . . |
. . . . . . . . . . . . . . . . . . 2 - 4 |
||
List of Switches and Components, Stand . . . . . |
. . . . . . . . . . . . . . . . . . 2 - 5 |
||
Switches . . . . . . . . . . . . . . . . . . . . |
. . . . . . . . . . . . . . . . . |
2 - 5 |
|
Potentiometers . . . . . . . . . . . . . . . . . |
. . . . . . . . . . . . . . . . . . 2 |
- 6 |
|
Motors . . . . . . . . . . . . . . . . . . . . . |
. . . . . . . . . . . . . . . . . . 2 |
- 6 |
|
Miscellaneous . . . . . . . . . . . . . . . . . |
. . . . . . . . . . . . . . . . . . 2 |
- 6 |
|
List of Signals and Test Points, Stand . . . . . . . |
. . . . . . . . . . . . . . . . . . 2 |
- 8 |
|
List of Voltages and Test Points, Stand . . . . . . |
. . . . . . . . . . . . . . . . . 2 - 12 |
3 _______Stand Functional Diagrams ______________________________________ 3 - 1
Block Diagram Cable Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 1 Grounding Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 2 Mains Connection, Power Supply CPU . . . . . . . . . . . . . . . . . . . . . . . 3 - 3 Grounding Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 3 Power Supply Motor Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 4 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 5
CPU Board Internal, Generator Interface . . . . . . . . . . . . . . . . . . . . . . |
. 3 |
- 6 |
|
Tube, Temperature Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . |
. 3 |
- 7 |
|
Lift and Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
|
3 |
- 8 |
Lift and Rotation Motor Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
. 3 |
- 9 |
|
Lift and Rotation Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 10 |
|||
Lift and Rotation Switches, M1000 with Remote Control . . . . . . . . . . . . . . |
3 |
- 11 |
|
Compression Measurement Signals . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 12 |
|||
Compression Motor Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
3 - 13 |
||
Tube Angle Measurement, Pot. Return,Tilt Signal . . . . . . . . . . . . . . . . . |
3 - 14 |
||
Collimator 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
3 |
- 15 |
|
Collimator 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
3 |
- 16 |
Siemens-Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 3 of 4 |
Mammomat 1000/3000 |
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
0 - 4 |
|
|
|
Contents |
||||
|
|
|
|
|
|
|
|
Page |
Object Table 1 + 2 . . . . . . . . . . . . . . . . . . |
. . . . . |
. . . . |
. |
. |
. . |
. |
. |
.3 - 17 |
Automatic Exposure Control (AEC) . . . . . . . . . . |
. . . . . |
. . . . |
. |
. |
. . |
. |
. |
.3 - 18 |
4 ______ Generator Overview ____________________________________________ 4 - 1
Mains Voltage Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4 |
- 1 |
List of PC-boards and Components, Generator . . . . . . . . . . . . . . . . . . . |
4 - 2 |
|
Subassembly and PC board overview/Baugruppen und Platinenübersicht . . . . |
4 - 2 |
|
Control Panel Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4 |
- 3 |
Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4 |
- 3 |
List of Switches and Components, Generator . . . . . . . . . . . . . . . . . . . . |
4 - 4 |
|
Control Panel Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 5 |
||
List of Switches and Components, Generator . . . . . . . . . . . . . . . . . . . . |
4 - 6 |
|
Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 6 |
||
Potentiometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4 |
- 6 |
Component Overview (Generator)/Bauteileübersicht (Generator) . . . . . . . . |
4 - 7 |
|
List of Signals and Test Points, Generator . . . . . . . . . . . . . . . . . . . . . . |
4 |
- 8 |
Signal Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 - 14
5 ______ General Functional Diagrams_____________________________________ 5 - 1
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 1
Ground, 0V and Protection Ground Distribution. . . . . . . . . . . . . . . . . . 5 - 2
Line Input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 3 Back Plane D700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 4 Principle Diagram, Master . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 5
Principle Diagram, Tube Filament . . . . . . . . . . . . . . . . . . . . . . . . 5 - 6 Principle Diagram, Focus Selection Board . . . . . . . . . . . . . . . . . . . . 5 - 7 Principle Diagram, Inverter Control and kV Regulation . . . . . . . . . . . . . . 5 - 8
Principle Diagram, Inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 9
Principle Diagram, Control Panel . . . . . . . . . . . . . . . . . . . . . . . .5 - 10
Principle Diagram, Iontomat . . . . . . . . . . . . . . . . . . . . . . . . . . .5 - 11
6 ______ Generator PC Board Overview ____________________________________ 6 - 1
Contact Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 1
Mammomat 1000/3000 |
Register 6 |
SP B7-230.051.05 |
Page 4 of 4 |
Siemens-Elema AB |
Wiring Diagrams |
|
Rev. 02 10.99 |
SPS-UD |
Solna, Sweden |
X041E |
1-1 |
SYSTEM OVERVIEW
MAMMOMAT 1000
MAMMOMAT 1000
MAMMOMAT
Fig. 1 Mammomat 1000 with generator with integrated control panel and radiation shield.
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 1 of 4 |
Mammomat 1000/3000 |
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
1-2 |
X041E |
SYSTEM OVERVIEW
MAMMOMAT 1000 WITH REMOTE CONTROL
MAMMOMAT 1000
MAMMOMAT 1000
MAMMOMAT
MAM00638
MAM00638
Fig. 2 Mammomat 1000 generator with integrated control panel and radiation shield.
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 2 of 4 |
Mammomat 1000/3000 |
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
X041E |
1-3 |
SYSTEM OVERVIEW
MAMMOMAT 3000
MAM00421
Fig. 3
MAMMOMAT 3000 installation with pivoted object-table arm and generator with integrated control panel and radiation shield.
Alternatively, the control panel and the radiation shield can be separated from the generator, see overleaf.
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 3 of 4 |
Mammomat 1000/3000 |
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
1-4 |
X041E |
SYSTEM OVERVIEW
MAMMOMAT 1000/3000
SIEMENS |
MAMMOMAT 3000 |
MAM00423 |
MAM00424 |
|
|
Fig. 4 Free-standing radiation shield with separate |
Fig. 5 Separate generator |
controle console |
|
SIEMENS
·
MAMMOMAT 3000
Counterweight
Fixed object-table arm
MAM00427
Fig. 6 Stand with fixed object-table arm
Pivoted object-table arm (“flying wing”) replaced by fixed object-table arm and counterweight.
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 4 of 4 |
Mammomat 1000/3000 |
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
X041E 2-1
PLACEMENT OF PC-BOARDS AND COMPONENTS, STAND
MAMMOMAT 1000
X877 M6
D813**** X878**
Tube
K7-K9
S867*
m5*
|
D807 |
Right side |
|
D807 |
Left side |
S865* |
|
D813**** |
|
|
|
S866* |
Lamp, X894 |
|
m4* |
||
m7* |
|
S897 |
S868* |
R861 |
|
m8* |
X874 |
|
|
|
|
|
R863 |
D811**** |
MAMMOMAT 1000
M2 (Compression)
Strain gauge
D804 |
|
|
|
|
Object table |
|
|
D813**** |
|
S861 |
|
X858*** |
||
S1 |
S892 |
|||
S862 |
||||
X870 |
||||
S2 |
X892 |
|||
|
||||
|
|
M
S883
S884
D803
X801
*not fitted with one filter collimator
**not used with one filter collimator
Z801
*** not used
D812**** D805
M1 (Lift), X887, R807
R871
S882
D801
D809
S880
S881
S869
M3 (Rotation)
X888
D802
D808 Right side
D808 Left side
R803 |
|
|
X898, R806 |
|
|
R805 |
|
|
X881 |
|
|
X885 |
|
|
X880, X803 |
|
|
T802 |
|
|
T801 |
|
|
X899 |
MAM00637 |
|
F801-805 |
||
|
Incoming mains
**** option, remote control
Fig. 7
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 1 of 16 Mammomat 1000/3000 |
|
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
2-2 |
X041E |
PLACEMENT OF PC-BOARDS AND COMPONENTS, STAND
MAMMOMAT 3000
|
|
|
M6 |
|
|
X877 |
D810 |
Tube |
D805 |
X878 |
|
|
|
|
K7-K9
S867, M5
D807 Right side
D807 Left side
S865
S866 Lamp, X894
M4
M7 S897
S868 R861
m8
X874
R863
M2 (Compression)
Strain gauge
D804 |
|
|
|
|
Object table |
S890 |
|
|
|
S1 |
S896 |
|
||
S861 |
X858 |
|||
S2 |
||||
S862 |
S895 |
X870 |
||
M |
||||
|
S891 |
|
||
|
|
|
||
|
S883 |
X891 |
|
|
|
|
|
||
|
S884 |
|
|
|
|
|
D803 |
|
|
|
|
X801 |
|
M1 (Lift), X887, R807
R871
S882
D801
D809
S880
S896
S881
S892
X892
S869
M3 (Rotation)
X888
D802
S894
D808 Right side
D808 Left side
R803
S860
X898, R806
R805
X880, X803
X881
X885
T802
T801
X899 |
MAM00426 |
|
F801-805 |
||
|
Z801
Incoming mains
Fig. 8 Stand with pivoted object-table arm
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 2 of 16 Mammomat 1000/3000 |
|
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
X041E |
2-3 |
|
PLACEMENT OF PC-BOARDS AND COMPONENTS, STAND |
|
|
|
|
SIEMENS
·
Counterweight
Fixed object-table arm
MAM00427
Fig. 9 Stand with fixed object-table arm
Pivoted object-table aram (“flying wing”) replaced by fixed object-table arm and counterweight
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 3 of 16 Mammomat 1000/3000 |
|
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
2-4 |
|
|
|
|
|
X041E |
LIST OF BOARDS AND FUSES, STAND |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PCB Overview |
|
|
|
|
|
|
D801 |
CPU BOARD |
|
|
||
|
D802 |
MOTOR CONTROL BOARD |
||||
|
D803 |
DISPLAY BOARD |
||||
|
D804 |
FORCE AMPLIFIER BOARD |
||||
|
D805 |
WING BOARD |
|
|
||
|
D807 |
BOARD FOR LIFT, ROTATION AND LAMP SWITCHES (NOT FIT- |
||||
|
|
TED IN M1000) |
|
|
||
|
D808 |
BOARD FOR LIFT AND ROTATION SWITCHES |
||||
|
D809 |
THICKNESS ADAPTER BOARD |
||||
|
D810 |
TILT SWITCH BOARD (Not fitted in M1000) |
||||
|
Option, remote control (MAMMOMAT 1000 only) |
|||||
|
D811 |
REMOTE CONTROL TRANSMITTER (2 INCLUDED) |
||||
|
D812 |
REMOTE CONTROL RECEIVER (1 INCLUDED) |
||||
|
D833 |
REMOTE CONTROL DETECTOR (4 INCLUDED) |
||||
|
Fuses Overview |
|
|
|
|
|
|
PCB |
FUSE |
FUSED VOLTAGE |
|||
|
|
|
|
|
|
|
|
D801 |
F1 |
2 |
AT |
+5V, +5V_REF, +5V_DSP, +7V |
|
|
D801 |
F2 |
1 AT |
+5V_MPS |
||
|
D802 |
F1 |
5 |
AT |
+5V, +5V_M, +14V, D805/+5V |
|
|
D802 |
F2 |
3.15 AT |
+24VF, +15V |
||
|
D802 |
F3 |
6.3 AT |
+24V |
||
|
D802 |
F5 |
5AT |
17VAC (LAMP) |
||
|
D802 |
F4 |
1 |
AT |
24VACF (FAN) |
|
|
Chassis-mounted |
|
|
|
|
|
|
fuses |
|
|
|
|
|
|
|
F801 |
2 AT |
11 VAC |
||
|
|
F802 |
1 AT |
11 V_MPS |
||
|
|
F803 |
5 AT |
14 VAC |
||
|
|
F804 |
5 AT |
17 VAC |
||
|
|
F805 |
6.3 AT |
24 VAC |
NOTE! See spare parts list for replacement fuses.
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 4 of 16 Mammomat 1000/3000 |
|
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
X041E |
|
2-5 |
|
|
|
LIST OF SWITCHES AND COMPONENTS, STAND |
|
|
|
|
|
|
|
|
|
|
Switches |
|
|
|
|
|
|
|
Switch |
Page |
Description |
|
|
|
|
|
|
|
|
|
S1/D801 |
3-6/1D |
Reset switch for stand CPU. |
|
|
|
|
|
S1/Object table |
3-16/2A |
Grid out switch located in the object table. |
|
|
|
|
|
S1-1-4/D802 |
3-9/3D |
Current limit switches: 1=+3%, 2=+6%, 3=+12%, 4=+24%. |
|
|
|
|
|
S1-5/D802 |
3-9/3D |
Tacho On/Off switch for rotation motor drive. |
|
|
|
|
|
S1-S6/D807* |
3-10/2A |
Control switches for lamp, liftand rotation movement. Left and right side. |
|
|
|
|
|
S1-S6/D811**** |
|
Control swithces and transmitter for lamp, liftand rotation movement. |
|
|
|
Left and right side. 2 provided. |
|
|
|
|
|
S1-S4/D808 |
3-10/4B |
Control switches for liftand rotation movement. Left and right side. |
|
|
|
|
|
S2/Object table |
3-16/2A |
Cassette inserted switch. |
|
|
|
|
|
S860* |
3-16/3C |
Stereo lever switch*. |
|
|
|
|
|
S861 |
3-12/2G |
Compression limit switch, compression unit. |
|
|
|
|
|
S862 |
3-12/2G |
Decompression limit switch, compression unit. |
|
|
|
|
|
S865** |
3-15/2E |
18 x 24 Collimator optoswitch**. |
|
|
|
|
|
S866** |
3-15/3E |
24 x 30 Collimator optoswitch**. |
|
|
|
|
|
S867** |
3-15/4E |
Filter position, optoswitch**. |
|
|
|
|
|
S868** |
3-15/5E |
Focus position optoswitch**. |
|
|
|
|
|
S869 |
3-8/3G |
Tacho optoswitch |
|
|
|
|
|
S880 |
3-4/2B |
Emergency stop, switches off 24VAC and 14VAC, machine blocked. |
|
|
|
|
|
S881 |
3-9/2G |
Lift up limit switch, rotating unit. |
|
|
|
|
|
S882 |
3-4/2A |
Limit switch, distance tube head - floor <50 mm, switches off 24VAC, |
|
|
|
machine blocked. |
|
|
|
|
|
S883 |
3-8/4B |
Collision protection switch, risk of collision when tubehead is less than |
|
|
|
120 mm from the floor. |
|
|
|
|
|
S884 |
3-9/2G |
Lift down limit switch, rotating unit. |
|
|
|
|
|
S890* |
3-16/3C |
AEC in position switch (Wing 1)*. |
|
|
|
|
|
S891* |
3-16/3C |
Object table locked in position (Wing1)*. |
|
|
|
|
|
S892 |
3-16/2C |
Object table locked in position (Wing 2)***. |
|
|
|
|
|
S894* |
3-16/3C |
Select wing 1 switch*, ***. |
|
|
|
|
|
S895* |
3-16/3C |
Select wing 2 switch*, ***. |
|
|
|
|
|
S896* |
3-13/5B |
Tilt opto-switch. 0° or ±10 0 used with stereo option*. |
|
S897 |
3-15/2G |
Diaphragm switch. |
|
|
|
|
|
S3 |
3-12/5F |
Decompression button (only with separate control console). |
|
|
|
|
*
**
***
****
Not fitted in M1000
Not fitted in M1000 with one filter Not fitted in M3000 one wing M1000 option, remote control
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 5 of 16 Mammomat 1000/3000 |
|
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
2-6 |
|
|
X041E |
|
LIST OF SWITCHES AND COMPONENTS, STAND |
||||
|
|
|
|
|
|
|
|
|
|
|
Potentiometers |
|
|
|
|
|
|
|
|
|
Potentiometer |
Page |
Description |
|
|
|
|
|
|
|
|
|
|
|
|
R803 |
3-13/2A |
Tube angle, 2k. |
|
|
|
|
|
|
|
R861 |
3-11/3E |
Preset force, 10k. |
|
|
|
|
|
|
|
R863 |
3-11/3E |
Thickness, 2k. |
|
|
|
|
|
|
|
R871 |
3-13/2A |
Preset angle, 10k. |
|
|
|
|
|
|
Motors
Motor |
Page |
Description |
|
|
|
M |
3-16/2A |
Grid motor, placed in object table with grid. |
|
|
|
M1 |
3-9/2G |
Lift motor. |
|
|
|
M2 |
3-12/2G |
Compression motor. |
|
|
|
M3 |
3-9/3G |
Rotation motor. |
|
|
|
M4* |
3-15/3D |
Collimator stepping motor*. |
|
|
|
M5* |
3-15/4D |
Filter stepping motor*. |
|
|
|
M6 |
3-7/4E |
Fan, tube cooling. |
|
|
|
M7* |
3-14/4G |
Mirror magnet*. |
|
|
|
M8* |
3-15/5D |
Focus stepping motor*. |
|
|
|
M9 |
3-9/5G |
Rotation brake. |
|
|
|
M10 |
3-9/5G |
Rotation brake. |
|
|
|
* Not fitted in M1000 with one filter |
|
|
Miscellaneous |
|
|
|
|
|
Misc. |
Page |
Description |
|
|
|
|
|
|
COMP. UNIT |
3-11, 3-12 |
Compression unit. |
|
|
|
CABLE DUCT |
3-2/3A |
Generator to stand cable protection. |
|
|
|
GROUND RAIL |
3-2/1E |
System grounding terminal. |
|
|
|
K7 |
3-7/4E |
Fan thermostat. |
|
|
|
K8 |
3-7/4E |
Tube overtemperature thermostat. |
|
|
|
K9 |
3-7/4E |
Tube housing overpressure switch. |
|
|
|
L804 - L809 |
3-9/SG |
VHF choke (EMC) |
|
3-12/2G |
|
|
|
|
LAMP |
3-14/5G |
Field light lamp. |
|
|
|
R805 |
3-9/5G |
Brake resistor, 6.2Ω. |
|
|
|
R806 |
3-9/5G |
Brake varistor |
|
|
|
R807 |
3-9/2G |
Lift motor varistor. |
|
|
|
R860 |
3-11/2A |
Strain gauge (R=300-400 Ω) |
|
|
|
T801 |
3-3/2C |
Mains transformer. |
|
|
|
T802 |
3-3/3C |
Insolation transformer |
|
|
|
Z801 |
3-3/4C |
Stereo mains filter, stand |
|
|
|
C801 - C803 |
3-12/5G |
EMC capacitors |
|
|
|
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 6 of 16 Mammomat 1000/3000 |
|
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
X041E 2-7
LIST OF SIGNALS AND TEST POINTS, STAND
This page intentionally left blank.
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 7 of 16 Mammomat 1000/3000 |
|
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
2-8 |
X041E |
LIST OF SIGNALS AND TEST POINTS,STAND
Page |
Signal Name |
Origin |
Via |
Destination |
Testpoint |
LED |
|
|
|
|
|
|
|
3-9/1C |
ACT_SPEED |
TACHO |
|
D802 |
ACT_SPEED |
|
|
|
|
|
|
|
|
3-16/3C |
AEC_POS |
S890 |
D801 |
D801 |
|
|
|
|
|
|
|
|
|
3-10/2A |
ANGLE_MEM |
A.M. -pot |
D807 |
D801 |
|
|
|
|
|
|
|
|
|
3-6/2B |
AR |
VH |
D801 |
GENERATOR |
D801 AR |
|
|
|
|
|
|
|
|
3-11/3B |
BR_OPEN |
D804 |
|
|
D804.X843 pin 8 |
V2 |
|
|
|
|
|
|
|
3-11/3B |
BR_RET |
D804 |
|
|
D804.X843 Pin 7 |
|
|
|
|
|
|
|
|
3-9/4B |
*BRAKE |
D801 |
|
D802 |
|
|
3-9/4E |
*BRAKE_RET |
D802 |
|
M9, M10 |
D802 |
|
3-9/4E |
*BRAKE_RELAY |
D802 |
|
not used |
|
|
3-15/3C |
C_LA |
D805 |
|
M4 |
|
|
|
|
|
|
|
|
|
3-15/3C |
C_LB |
D805 |
|
M4 |
|
|
|
|
|
|
|
|
|
3-9/4E |
C_LIM |
D802 |
|
|
|
V11 |
|
|
|
|
|
|
|
3-15/3C |
*C_PA1 |
D805 |
|
M4 |
|
|
3-15/3C |
*C_PA2 |
D805 |
|
M4 |
|
|
3-15/3C |
*C_PB1 |
D805 |
|
M4 |
|
|
3-15/3C |
*C_PB2 |
D805 |
|
M4 |
|
|
3-12/2D |
C_PWM |
D802 |
|
M2 |
D802 |
|
|
|
|
|
|
|
|
3-16/1A |
CASS_LOADED |
OBJ. TABLE |
D805 |
D801 |
|
|
|
|
|
|
|
|
|
3-16/2C |
*COLL_DIR |
D801 |
|
D805 |
D805 COLL_D |
|
3-16/2C |
*COLL_STEP |
D801 |
|
D805 |
D801, D805 COLL_ST |
|
3-16/3E |
COLL_POS_18X24 |
18x24 switch |
D805 |
D801 |
COLL_P1 |
|
|
|
|
|
|
|
|
3-16/4E |
COLL_POS_24X30 |
24x30 switch |
D805 |
D801 |
COLL_P2 |
|
|
|
|
|
|
|
|
3-12/1E |
COMP_LIMIT |
D802 |
D805 |
COMP. UNIT |
|
|
|
|
|
|
|
|
|
3-12/1B |
*COMP_DIR |
D801 |
|
D802 |
D802 COMP_D |
|
3-11/2F |
COMP_FORCE |
D804 |
|
D801 |
D804.X843 pin 5 |
|
|
|
|
|
|
|
|
3-12/3E |
COMP_OK |
D802 |
|
D801 |
|
D802 V2 |
|
|
|
|
|
|
COMP_ERR |
|
|
|
|
|
|
|
3-12/1E |
COMP_PROT |
D802 |
|
D801 |
D802 |
|
|
|
|
|
|
|
|
3-12/1B |
*COMP_SPEED |
D801 |
|
D802 |
D801, D802 |
|
|
|
|
|
|
COMP_SP |
|
3-12/4F |
COMPRESS |
PEDAL |
D805 |
D801, D802 |
|
|
|
|
|
|
|
|
|
3-9/2D |
D_PWM |
D802 |
|
|
D802 |
|
|
|
|
|
|
|
|
3-12/1E |
DECOMP_ LIMIT |
D802 |
D805 |
COMP. UNIT |
|
|
|
|
|
|
|
|
|
3-12/4F |
DECOMPRESS |
PEDAL / ** |
|
D801 |
|
|
|
|
|
|
|
|
|
3-9/3B |
*DIR |
D801 |
|
D802 |
D802 |
|
3-9/4F |
DRIVE_OK |
D802 |
|
D801 |
|
D802 |
|
|
|
|
|
|
V24DRIVE_ERR |
|
|
|
|
|
|
|
3-9/1E |
DRIVE_PROT |
D802 |
|
D801 |
D802 |
|
|
|
|
|
|
|
|
3-15/3D |
FI_LA |
D805 |
|
M5 |
|
|
|
|
|
|
|
|
|
3-15/3D |
FI_LB |
D805 |
|
M5 |
|
|
|
|
|
|
|
|
|
3-15/3D |
*FI_PA1 |
D805 |
|
M5 |
|
|
“*SIGNAL” = “SIGNAL” active low
**plus decompression button on separate control console.
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 8 of 16 Mammomat 1000/3000 |
|
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
X041E |
2-9 |
|
LIST OF SIGNALS AND TEST POINTS, STAND |
|
|
|
|
Signal Name |
Description |
|
|
|
|
ACT_SPEED |
Test point for frequency to voltage converted tacho signal. |
|
|
AEC_POS |
AEC-detector in position near breast. |
|
|
ANGLE_MEM |
Operator control signal for preset stop angle. |
|
|
AR |
Signal given to generator as exposure request. If grid used, grid has started. |
|
|
BR_OPEN |
Bridge open, compression force strain gauge not working correctly. |
|
|
BR_RET |
Compression force strain guage return line (appr. 0V) |
|
|
*BRAKE |
Control signal to brake reversing relay. |
|
|
*BRAKE_RET |
Output to the brakes for max or min braking when active. |
|
|
*BRAKE RELAY |
Output to brake reversing relay, max brake if *BRAKE_RET active. |
C_LA |
Output line A. Collimator stepping motor M4 |
|
|
C_LB |
Output line B. Collimator stepping motor M4 |
|
|
C_LIM |
Rotation and fast-acting current limit |
|
|
*C_PA1 |
Output Phase A1. Collimator stepping motor M4 |
*C_PA2 |
Output Phase A2. Collimator stepping motor M4 |
*C_PB1 |
Output Phase B1. Collimator stepping motor M4 |
*C_PB2 |
Output Phase B2. Collimator stepping motor M4 |
C_PWM |
Pulse Width Modulated power output to compression motor. |
|
|
CASS_LOADED |
Cassette inserted in object table. |
|
|
*COLL_DIR |
Direction Control signal . For the filter stepping motor. |
*COLL_STEP |
Step control signal for the collimator stepping motor. |
COLL_POS_18X24 |
Signal from the 18 x 24 collimator optoswitch |
|
|
COLL_POS_24X30 |
Signal from the 24 x 30 collimator optoswitch |
|
|
COMP |
Power output via compression limit switch to compression motor. |
|
|
*COMP_DIR |
Controls compression motor to compress (moving down) |
COMP_FORCE |
Analog signal indicating compression force. |
|
|
COMP_OK |
Compression motor working correctly, no over current. |
|
|
COMP_PROT |
Compression relay K4 is working correctly, checked 1s after pedal release. |
|
|
*COMP_SPEED |
Pulse Width Modulated signal to control speed of compression motor (20kHz). |
COMPRESS |
Operator control signal to move compression plate down. |
|
|
D_PWM |
Pulse Width Modulated power output to rotation or lift motor. |
|
|
DECOMP |
Power output via decompression limit switch to compression motor. |
|
|
DECOMPRESS |
Operator control signal to move compression plate up. |
|
|
*DIR |
Selecting direction of rotation or lift motor. |
DRIVE_OK |
Rotation and lift motor are working correctly, no over current, approx. 1.5 s delay. |
|
|
DRIVE_PROT |
DMG relay K6 is working correctly, checked 3s after rot/lift button is released. |
|
|
FI_LA |
Output line A. Filter stepping motor M5 |
|
|
FI_LB |
Output line B. Filter stepping motor M5 |
|
|
*FI_PA1 |
Output phase A1. Filter stepping motor M5 |
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 9 of 16 Mammomat 1000/3000 |
|
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
2-10 |
X041E |
LIST OF SIGNALS AND TEST POINTS, STAND
Page |
Signal Name |
Origin |
Via |
Destination |
Testpoint |
LED |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3-15/4C |
*FI_PA2 |
D805 |
|
M5 |
|
|
3-15/4C |
*FI_PB1 |
D805 |
|
M5 |
|
|
3-15/4C |
*FI_PB2 |
D805 |
|
M5 |
|
|
3-15/2C |
*FILTER_DIR |
D801 |
|
D805 |
D805 FILT_D |
|
3-15/2B |
FILTER_POS |
Filter switch |
D805 |
D801 |
FILT_P |
|
|
|
|
|
|
|
|
3-15/2C |
*FILTER_STEP |
D801 |
|
D805 |
D805 FILT_ST |
|
3-15/5C |
FO_LA |
D805 |
|
M8 |
|
|
|
|
|
|
|
|
|
3-15/5C |
FO_LB |
D805 |
|
M8 |
|
|
|
|
|
|
|
|
|
3-15/5C |
*FO_PA1 |
D805 |
|
M8 |
|
|
3-15/5C |
*FO_PA2 |
D805 |
|
M8 |
|
|
3-15/5C |
*FO_PB1 |
D805 |
|
M8 |
|
|
3-15/5C |
*FO_PB2 |
D805 |
|
M8 |
|
|
3-15/1C |
*FOCUS_DIR |
D801 |
|
D805 |
D805 FOCUS_D |
|
3-15/1B |
FOCUS_POS |
Focus switch |
D805 |
D801 |
FOCUS_P |
|
|
|
|
|
|
|
|
3-15/1C |
*FOCUS_STEP |
D801 |
|
D805 |
D805 FOCUS_DT |
|
3-16/3B |
GRID_MOTOR_N |
D802 |
D805 |
OBJ. TABLE |
D802 GRID_M |
|
|
|
|
|
|
|
|
3-16/2A |
GRID_OUT |
OBJ. TABLE |
D805 |
D801 |
D801 GRID_O |
|
|
|
|
|
|
|
|
3-16/2G |
*GRID_SPEED |
D801 |
|
D802 |
D801 GRID_SP |
|
3-11/3D |
I1_OUT |
D804 |
|
|
D804.X843 pin 6 |
|
|
|
|
|
|
|
|
3-6/2B |
*KVA |
D801,D701 |
|
D700 (GENERATOR) |
D801 (D705, X715) |
|
|
|
D702, D705 |
|
|
|
|
|
|
|
|
|
|
|
3-14/5G |
LAMP |
D807, D812** |
D805 |
D801 |
|
|
|
|
|
|
|
|
|
3-14/4C |
*LAMP_CTRL |
D801 |
|
D802 |
|
|
3-14/5F |
LAMP_V |
D802 |
|
LAMP |
D802 LAMP |
|
|
|
|
|
|
|
|
3-8/3D |
LED |
D802 |
|
TACHO switch |
|
|
|
|
|
|
|
|
|
3-15/2E |
LED_1 |
D805 |
|
18 x 24 switch |
|
|
|
|
|
|
|
|
|
3-15/3E |
LED_2 |
D805 |
|
24 x 30 switch |
|
|
|
|
|
|
|
|
|
3-15/4E |
LED_3 |
D805 |
|
Filter switch |
|
|
|
|
|
|
|
|
|
3-15/5E |
LED_4 |
D805 |
|
Focus switch |
|
|
|
|
|
|
|
|
|
3-10/2A |
LIFT_DOWN |
D807, D808, D812** |
D805 |
D801, D802 |
|
|
|
|
|
|
|
|
|
3-10/2A |
LIFT_UP |
D807, D808, D812** |
D805 |
D801, D802 |
|
|
|
|
|
|
|
|
|
3-14/4F |
*MIRROR_MAGNET |
D802 |
|
M7 |
D802 MIRROR |
|
3-6/3B |
MPS |
D801 |
|
GENERATOR |
D801 |
|
|
|
|
|
|
|
|
3-7/4C |
OKT1_ |
TUBE/K8 |
|
GENERATOR |
|
|
|
|
|
|
|
|
|
3-7/4C |
OKT2_ |
TUBE/K9 |
|
GENERATOR |
|
|
|
|
|
|
|
|
|
3-9/2C |
PGM_SPEED |
D802 |
|
|
PGM_SPEED |
|
|
|
|
|
|
|
|
3-13/2D |
POT_RETURN |
POT |
|
D801 |
|
|
|
|
|
|
|
|
|
3-11/2E |
PRES_FORCE |
R861 |
|
D801 |
|
|
|
|
|
|
|
|
|
3-13/1A |
PRESET_ANGLE |
R871 |
D805 |
D801 |
|
|
|
|
|
|
|
|
|
“*SIGNAL” = “SIGNAL” active low |
** M1000 option, remote control, D807 not fitted |
|
||
|
|
|
|
|
|
|
|
|
|
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 10 of 16 Mammomat 1000/3000 |
|
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
X041E |
2-11 |
|
LIST OF SIGNALS AND TEST POINTS, STAND |
|
|
|
|
Signal Name |
Description |
|
|
|
|
*FI_PA2 |
Output phase A2. Filter stepping motor M5 |
*FI_PB1 |
Output phase B1. Filter stepping motor M5 |
*FI_PB2 |
Output phase B2. Filter stepping motor M5 |
*FILTER_DIR |
Control signal . For the filter stepping motor. |
FILTER_POS |
Signal from the filter pos collimator optoswitch |
|
|
*FILTER_STEP |
Step control. For the filter stepping motor. |
FO_LA |
Output line A. Focus stepping motor M8 |
|
|
FO_LB |
Output line B. Focus stepping motor M8 |
|
|
*FO_PA1 |
Output Phase A1. Focus stepping motor M8 |
*FO_PA2 |
Output Phase A2. Focus stepping motor M8 |
*FO_PB1 |
Output Phase B1. Focus stepping motor M8 |
*FO_PB2 |
Output Phase B2. Focus stepping motor M8 |
*FOCUS_DIR |
Control signal for the focus stepping motor. |
FOCUS_POS |
Signal from the focus pos collimator optoswitch. |
|
|
*FOCUS_STEP |
Step control signal for the focus stepping motor. |
GRID_MOTOR_N |
Grid motor return line. |
|
|
GRID_OUT |
Active when the grid is not in end position. |
|
|
*GRID_SPEED |
Pulse Width Modulated signal control speed of grid motor. |
I1_OUT |
Output signal from compression force preamplifier. |
|
|
*KVA |
Signal to terminate exposure. WIRED-OR line, see generator. |
LAMP |
Operator control signal for the field light lamp. |
|
|
*LAMP_CTRL |
Signal to switch on the field light lamp. |
LAMP_V |
Output to the field light lamp. |
|
|
LED |
Output to the LED in the tacho opto switch in the rotation motor. |
|
|
LED_1 |
Output to the LED in the 18 x 24 collimator opto switch. |
|
|
LED_2 |
Output to the LED in the 24 x 30 collimator opto switch. |
|
|
LED_3 |
Output to the LED in the filter collimator opto switch. |
|
|
LED_4 |
Output to the LED in the focus collimator opto switch. |
|
|
LIFT_DOWN |
Operator control signal to move compression plate down. |
|
|
LIFT_UP |
Operator control signal to move compression plate up. |
|
|
*MIRROR_MAGNET |
Output to mirror magnet. Enabled via *LAMP_CTRL. |
MPS |
Multi processor serial communication for information exchange Master - Slaves. |
|
|
OKT1_ |
Signal from temperature switch K8 on the tube. |
|
|
OKT2_ |
Signal from the over pressure switch K9 on the tube. |
|
|
PGM_SPEED |
Test point for duty cycle to voltage converted programmed speed signal. |
|
|
POT_RETURN |
Return line for potentiometers connected to 0VA via a 20Ω resistor. |
|
|
PRES_FORCE |
Analog signal as preset value for maximum compression force. |
|
|
PRESET_ANGLE |
Analog signal as preset value for requested rotation angle. |
|
|
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 11 of 16 Mammomat 1000/3000 |
|
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
2-12 |
X041E |
LIST OF VOLTAGES AND TEST POINTS, STAND
Page |
Signal Name |
Origin |
Via |
Destination |
Testpoint |
LED |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3-12/2D |
PU |
D802 |
|
|
PU |
|
|
|
|
|
|
|
|
3-9/4B |
*RELEASE |
D801 |
|
D802 |
D802 |
|
3-6/1E |
*RESET |
D801 |
|
|
|
|
3-6/1E |
*RESET_HW |
D801 |
|
|
|
|
|
|
|
|
|
|
|
3-6/1E |
RESET_SW |
D801 |
|
|
|
|
|
|
|
|
|
|
|
3-10/3A |
ROT_CW |
D807, D808, |
D805 |
D801, D802 |
|
|
|
|
D812*** |
|
|
|
|
|
|
|
|
|
|
|
3-10/3A |
ROT_CCW |
D807, D808, |
D805 |
D801, D802 |
|
|
|
|
D812*** |
|
|
|
|
|
|
|
|
|
|
|
3-13/4A |
ROT_POS** |
D806** |
|
D801 |
|
|
|
|
|
|
|
|
|
3-6/3D |
RXD |
GEN. |
|
D801 |
D801 |
|
|
|
|
|
|
|
|
3-9/3B |
*SEL_ROT |
D801 |
|
D802 |
D802 SEL_ROT |
|
3-16/3C |
SELECT_WING1 |
S891 |
|
D801 |
|
|
|
|
|
|
|
|
|
3-16/4C |
SELECT_WING2 |
S892 |
|
D801 |
|
|
|
|
|
|
|
|
|
3-9/2B |
*SPEED |
D801 |
|
D802 |
D801, D802 SPEED |
|
3-15/2C |
*STEP_ENABLE |
D801 |
|
D805 |
D805 STEP_EN |
|
3-15/1B |
STEREO_COLL |
S897 |
|
D801 |
|
|
|
|
|
|
|
|
|
3-16 |
STEREO_LEVER |
S860 |
D805 |
D801 |
|
|
|
|
|
|
|
|
|
3-14/1B |
TABLE_CONFIG |
OBJ.TABLE |
D805 |
D801 |
|
|
|
|
|
|
|
|
|
3-8/3G |
TACHO |
Tacho switch |
|
D802 |
D802 TACHO |
|
|
|
|
|
|
|
|
3-11/3E |
THICKNESS |
R863 |
|
D801 |
|
|
|
|
|
|
|
|
|
3-11/5E |
THICKNESS_B |
THICKNESS |
D809 |
|
|
|
|
|
|
|
|
|
|
3-11/5F |
THICKNESS_STE- |
D809 |
|
X885 |
|
|
|
REO |
|
|
|
|
|
|
|
|
|
|
|
|
3-13/5B |
TILT |
S896/D810 |
D805 |
D801 |
|
D810 V8 |
|
|
|
|
|
|
|
3-13/2A |
TUBE_ANGLE |
R803 |
|
D801 |
|
|
|
|
|
|
|
|
|
3-6/4D |
TXD |
D801 |
|
GENERATOR |
D801 TXD |
|
|
|
|
|
|
|
|
3-6/3B |
VH |
GEN. |
|
D801 |
|
|
|
|
|
|
|
|
|
3-11/3C |
ZERO |
D804 |
|
|
D804.X843 pin 4 |
|
|
|
|
|
|
|
|
“*SIGNAL” = “SIGNAL” active low.
**Not used with software v2.1 or higher.
***M1000 option, remote control, D807 not fitted
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 12 of 16 Mammomat 1000/3000 |
|
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |
X041E |
2-13 |
|
LIST OF VOLTAGES AND TEST POINTS, STAND |
|
|
|
|
Signal Name |
Description |
|
|
|
|
PU |
Pull up signal for error comparators = +15V, +5V, +24V voltages OK. |
|
|
*RELEASE |
Control signal to release the brakes from min or max to permanent magnet braking. |
RESET |
Reset signal to the CPU. |
|
|
RESET_HW |
Reset signal from the CPU to the reset cicuit, caused by slave restart and CPU watchdog |
|
reset. |
|
|
RESET_SW |
Signal from the reset switch to the CPU via the reset circuit. |
|
|
ROT_CW |
Operator control signal to rotate the x-ray system clockwise. |
|
|
ROT_CCW |
Operator control signal to rotate the x-ray system counter clockwise. |
|
|
ROT_POS |
Low level signal pulse indicating +10 or -10 degrees of rotation. |
|
|
RXD |
Input for receiving data via MPS. |
|
|
*SEL_ROT |
Low level signal selects the rotation drive to be controlled. |
SELECT_WING1 |
Signal from select wing 1 switch. Wing 1 selected. |
|
|
SELECT_WING2 |
Signal from select wing 2 switch. Wing 2 selected. |
|
|
*SPEED |
Pulse Width Modulated signal to control speed of rotation or lift motor (20 kHz). |
*STEP_ENABLE |
Control signal to enable all stepping motors. |
STEREO_COLL |
External diaphragm switch, diaphragm in place. For stereo or spot diaphragm, 18 x 24 |
|
collimator in M1000 with one filter. |
|
|
STEREO_LEVER |
Signal from stereo lever switch, indicating lever not in stereo position. |
|
|
TABLE_CONFIG |
4 inputs from object table, see table configuration . |
|
|
TACHO |
Signal from rotation motor tachometer. |
|
|
THICKNESS |
Analog signal indicating the compression thickness. |
|
|
THICKNESS_B |
Buffered output to the thickness adapter board D809 (Stereo option) |
|
|
THICKNESS_STE-REO |
Isolated analog signal indicating compression thickness for stereo evaluation unit. |
|
|
TILT |
Indicates that the stereo angle is 0° or ±10°. Visible through vent opening behind tube. |
|
|
TUBE ANGLE |
Analog signal indicating the rotation angle. |
|
|
TXD |
Output for sending data via MPS. |
|
|
VH |
The stand is informed that the generator has completed its preparation. |
|
|
ZERO |
Used for adjusting offset of the compression force amplifiers. |
|
|
Siemens Elema AB |
Register 6 |
SP B7-230.051.05 |
Page 13 of 16 Mammomat 1000/3000 |
|
Solna, Sweden |
|
Rev. 02 10.99 |
SPS-UD |
Wiring Diagrams |