Shelley F5PC48N Installation Manual

F5 and F15 Series
Refrigerated Display Cases
Original Instructions Installation, Operation and Maintenance Manual
This manual is updated as new information and models are released. Visit our website for the latest manual.
Part Number: 9291460 6/15
F5 & F15 Series Service and Installation Manual
Important Warning And Safety Information
WARNING Failure To Follow Instructions In This Manual Can Cause Property Damage, Injury Or Death.
WARNING Do Not Store Or Use Gasoline Or Other Flammable Vapors Or Liquids In The Vicinity Of This Or Any Other
Appliance.
WARNING Unless All Cover And Access Panels Are In Place And Properly Secured, Do Not Operate This Equipment.
WARNING This Appliance Is Not Intended For Use By Persons Who Lack Experience Or Knowledge, Unless They Have
Been Given Supervision Or Instruction Concerning Use Of The Appliance By A Person Responsible For Their Safety.
WARNING This Appliance Is Not To Be Played With.
WARNING Do Not Clean With Water Jet.
WARNING Do Not Use Electrical Appliances Inside The Food Storage Compartment Of This Appliance.
CAUTION Observe the following:
Minimum clearances must be maintained from all walls and combustible materials.
Keep the equipment area free and clear of combustible material.
Allow adequate clearance for air openings.
Operate equipment only on the type of electricity indicated on the specification plate.
Unplug the unit before making any repairs.
Retain this manual for future reference.
2
Contents
Receiving & Inspecting Equipment ...................................................3
Serial Number Location ....................................................................4
Warranty Information.........................................................................4
Regulatory Certifications ...................................................................4
Specifications................................................................................ 5-6
Installation .................................................................................... 7-8
Shelf Installation ...............................................................................9
Display Lock Operation .....................................................................9
Operation ..........................................................................................9
Temperature Control Settings ..........................................................10
Pressure Control Settings ...............................................................10
Maintenance.............................................................................. 11-12
Condenser Air Flow ........................................................................13
Sliding Door ...................................................................................14
F5 & F15 Series Service and Installation Manual
Notes...............................................................................................15
Receiving And Inspecting The Equipment
Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not damaged while being moved into the building.
1. Visually inspect the exterior of the package and skid or container. Any damage should be noted and reported to the delivering carrier immediately.
2. If damaged, open and inspect the contents with the carrier.
3. In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment notify the carrier. Notification should be made verbally as well as in written form.
4. Request an inspection by the shipping company of the damaged equipment. This should be done within 10 days from receipt of the equipment.
5. Check the lower portion of the unit to be sure legs or
6. Also open the compressor compartment housing and
7. Freight carriers can supply the necessary damage forms
8. Retain all crating material until an inspection has been
Uncrating the Equipment
First cut and remove the banding from around the crate. Remove the front of the crate material, use of some tools will be required. If the unit is on legs remove the top of the crate as well and lift the unit off the skid. If the unit is on casters it can be "rolled" off the skid.
casters are not bent.
visually inspect the refrigeration package. Be sure lines are secure and base is still intact.
upon request.
made or waived.
3
F5 & F15 Series Service and Installation Manual
Serial Number Location
The serial number on all self-contained F5 Series units is located near the condensing unit. On all remote F5 Series units the serial number is located on the drop-in frame.
The serial number on all self-contained F15 Series units is located behind the compressor housing. On all remote F15 Series units the serial number is located behind the six inch panel in the base.
Always have the serial number of your unit available when calling for parts or service. A complete list of authorized Delfield parts depots is available at www.delfield.com.
©2015 The Delfield Company. All rights reserved. Reproduction without written permission is prohibited.
SERIAL #
MODEL #
INSTALLATION DATE:
Warranty Information
Visit http://www.delfield.com/minisite/service/warranty_info to:
• Register your product for warranty.
• Verify warranty information.
• View and download a copy of your warranty.
Regulatory Certifications
All models are certified by:
National Sanitation Foundation (NSF)
Underwriters Laboratories (UL)
4
F5 & F15 Series Service and Installation Manual
F5 Series Specifications
24” (61cm) Deep Remote Drop-In Refrigerated Display Cases
MODEL L D H
F5MR48N 48" (121.9cm) 24" (61.0cm) 42" (106.7cm) 115/60/1 4.0 1215 150 20° 15°
F5SR48N 48" (121.9cm) 24" (61.0cm) 42" (106.7cm) 115/60/1 4.0 1867 150 20° 15°
F5PR48N 48" (121.9cm) 24" (61.0cm) 42" (106.7cm) 115/60/1 4.0 1945 150 20° 15°
F5MR72N 72" (182.9cm) 24" (61.0cm) 42" (106.7cm) 115/60/1 4.0 1783 450 13° 22°
F5SR72N 72" (182.9cm) 24" (61.0cm) 42" (106.7cm) 115/60/1 4.0 2791 450 13° 22°
F5PR72N 72" (182.9cm) 24" (61.0cm) 42" (106.7cm) 115/60/1 4.0 2884 450 13° 22°
24” (61cm) Deep Self-Contained Drop-In Refrigerated Display Cases
MODEL L D H
F5MC48N 48" (121.9cm) 24" (61.0cm) 57.5" (146.1cm) 115/60/1 12.0 1215 2970 1/2 32 5-15P
F5SC48N 48" (121.9cm) 24" (61.0cm) 57.5" (146.1cm) 115/60/1 12.0 1867 2970 1/2 32 5-15P
F5PC48N 48" (121.9cm) 24" (61.0cm) 57.5" (146.1cm) 115/60/1 12.0 1945 2970 1/2 32 5-15P
F5MC72N 72" (182.9cm) 24" (61.0cm) 57.5" (146.1cm) 115/60/1 16.0 1783 5821 3/4 48 5-20P
F5SC72N 72" (182.9cm) 24" (61.0cm) 57.5" (146.1cm) 115/60/1 16.0 2791 5821 3/4 48 5-20P
F5PC72N 72" (182.9cm) 24" (61.0cm) 57.5" (146.1cm) 115/60/1 16.0 2884 5821 3/4 48 5-20P
VOLTS/ HERTZ/ PHASE AMPS
VOLTS/ HERTZ/ PHASE AMPS
CABINET LOAD BTU/ HOUR
CABINET LOAD BTU/ HOUR
EVAPORATOR DISPLAY CAPACITY
BTU °TD TEMP
SYSTEM CAPACITY BTU/HOUR H.P.
R404A CHARGE, OZ.
NEMA PLUG
30” (76.2cm) Deep Remote Drop-In Refrigerated Display Cases
VOLTS/
MODEL L D H
F5MR48D 48" (121.9cm) 30" (76.2cm) 42" (106.7cm) 115/60/1 4.0 1282 150 20° 15°
F5SR48D 48" (121.9cm) 30" (76.2cm) 42" (106.7cm) 115/60/1 4.0 1934 150 20° 15°
F5PR48D 48" (121.9cm) 30" (76.2cm) 42" (106.7cm) 115/60/1 4.0 2012 150 20° 15°
F5MR72D 72" (182.9cm) 30" (76.2cm) 42" (106.7cm) 115/60/1 4.0 1870 450 13° 22°
F5SR72D 72" (182.9cm) 30" (76.2cm) 42" (106.7cm) 115/60/1 4.0 2878 450 13° 22°
F5PR72D 72" (182.9cm) 30" (76.2cm) 42" (106.7cm) 115/60/1 4.0 2971 450 13° 22°
30” (76.2cm) Deep Self-Contained Drop-In Refrigerated Display Cases
MODEL L D H
F5MC48D 48" (121.9cm) 30" (76.2cm) 57.5" (146.1cm) 115/60/1 12.0 1282 2970 1/2 32 5-15P
F5SC48D 48" (121.9cm) 30" (76.2cm) 57.5" (146.1cm) 115/60/1 12.0 1934 2970 1/2 32 5-15P
F5PC48D 48" (121.9cm) 30" (76.2cm) 57.5" (146.1cm) 115/60/1 12.0 2012 2970 1/2 32 5-15P
F5MC72D 72" (182.9cm) 30" (76.2cm) 57.5" (146.1cm) 115/60/1 16.0 1870 5821 3/4 48 5-20P
F5SC72D 72" (182.9cm) 30" (76.2cm) 57.5" (146.1cm) 115/60/1 16.0 2878 5821 3/4 48 5-20P
F5PC72D 72" (182.9cm) 30" (76.2cm) 57.5" (146.1cm) 115/60/1 16.0 2971 5821 3/4 48 5-20P
HERTZ/ PHASE AMPS
VOLTS/ HERTZ/ PHASE AMPS
CABINET LOAD BTU/ HOUR
CABINET LOAD BTU/ HOUR
EVAPORATOR DISPLAY CAPACITY
BTU °TD TEMP
SYSTEM CAPACITY BTU/HOUR H.P.
R404A CHARGE, OZ.
NEMA PLUG
M = Mirror Back • P = Pass Thru • S = See Thru • R = Remote • C = Self-Contained • N = Narrow • D = Deep 30”
5