Sharp S102T01, S102T02, S202T01, S202T02 Datasheet

0 (0)
S102T01/S102T02 S202T01/S202T02
S102T01/S102T02/S202T01/S202T02
Low Height Type Solid State Relays
Outline Dimensions
Features
1. Low height type (height : 16 mm) 30% less compared with S101S05V
2.
Effective ON-state current IT : MAX. 2Ams (Ta= <=40˚C)
3. Model Line-ups
No zero cross circuit
AC100V S102T01 S102T02 AC200V S202T01 S202T02
4. Recognized by UL, file No. E94758
Approved by CSA, No. LR63705
Applications
Built-in zero cross circuit
)
25.8
(
1. Programmable controllers
2. Air conditioners
3. Copiers
4. Automatic vending machines
Internal Connection Diagram S102T01/S202T01 S102T02/S202T02
Absolute Maximum ratings
Symbol UnitParameter
Input
Output
Forward current I Reverse voltage V
*1
Effective ON-state current
*2
Peak one cycle surge current Repetitive peak OFF-state voltage V Non-repetitive peak OFF-state voltage V Critical rate of rise of ON-state current Operating frequency f 45to 65 Hz Operating temperature Storage temperature
*3
Isolation voltage Soldering temperature T
*1 Refer to Fig. 1. *2 60Hz sine wave, start at Tj=25˚C *3 Isolation voltage test method
1) Use a dielectric withstand voltage tester with zero cross circuit.
2) The applied voltage waveform shall be sine wave.
3) Apply voltage between input and output. (Input and output terminals shall be shorted respectively.)
F
R
I
T
I
surge
DRM DSM
dIT/dt 40 A/µs
T
opr
T
stg
V
iso sol
(Unit : mm)
*
1
23
φ 3.7
A
B
*
4-0.8
23
(
)(
5.08
A (Model No.)
S102T01 S102T02 S202T01 S202T02
+-
MAX3.8
)(
10.16
B
2A125VAC
2A265VAC
1 Output (Triac T1) 2 Output (Triac T2) 3 Input (+) 4 Input (-)
*
11.5
9.6
4
)
2.54 *Terminal : Do not allow
Zero cross circuit
4
3
16
0.4
1.8
external connection.
(Ta=25˚C)
Rating
/S102T01 S102T02 /S202T01 S202T02
50 mA
6V 2A
rms
20 A 400 600 V 400 600 V
- 25 to +100 ˚C
- 30 to +125 ˚C 3 000
V
rms
260 (For 10 seconds) ˚C
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.
Loading...