Sharp AH-AP18CE, AH-AP24CE, AY-AP18CE, AY-AP24CE Operating Manual

0 (0)
Sharp AH-AP18CE, AH-AP24CE, AY-AP18CE, AY-AP24CE Operating Manual

R

INDOOR UNIT

OUTDOOR UNIT

ZIMMERGERÄT

AUSSENGERÄT

UNIT INTERIEURE

UNIT EXTERIEURE

UNIDAD INTERIOR

UNIDAD EXTERIOR

UNITA' INTERNA

UNITA' ESTERNA

UNIDADE INTERIOR

UNIDADE EXTERIOR

ΕΣΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ

Ε ΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ

BINNEN-UNIT

BUITEN-UNIT

∑Ç ÜN∑TE

DIΩ ÜN∑TE

DZENHTZZBQ ;KJR

ZFHEÖZBQ ;KJR

AY-AP18CE AE -A18CE AY-AP24CE AE -A24CE AH-AP18CE AU-A18CE AH-AP24CE AU-A24CE

MODELS

AY -AP18C E AY -AP24C E AH -AP18C E AH -AP24C E

SPLIT TYPE

ROOM AIR CONDITIONER

ZWEITEILIGES

KLIMAGERÄT

CLIMATISEUR INDIVIDUEL EN DEUX PARTIES

ACONDICIONADOR DE AIRE DE DOBLE SERVICIO

CONDIZIONATORE D'ARIA DA CAMERA TIPO SPLIT

AR CONDICIONADO

DE DUAS UNIDADES

ΑΙΡΚ ΝΤΙΣΙ Ν ∆ΩΜΑΤΙ Υ ΤΥΠ Υ SPLIT

SPLIT-AIRCONDITIONER

SPL∑T KL∑MA

КОМНАТНЫЙ КОНДИЦИОНЕР ДВУБЛОЧНОГО ТИПА

OPERATION MANUAL BEDIENUNGSANLEITUNG NOTICE D'UTILISATION MANUAL DE INSTRUCCIONES MANUALE DI ISTRUZIONE MANUAL DE INSTRUÇÕES

ΕΓ ΕΙΡΙ∆Ι ΛΕΙΤ ΥΡΓΙΑΣ

GEBRUIKSAANWIJZING

KULLANMA KILAVUZU

РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

ENGLISH DEUTSCH FRANÇAIS ESPAÑOL ITALIANO

PORTUGUÊS ΕΛΛΗΝΙΚΑ NEDERLANDS

TÜRKÇE HECCRBQ

ENGLISH

Thank you for purchasing a SHARP air conditioner. Please read this manual carefully before operating the product.

CONTENTS

...........................................• PRECAUTIONS

E-1

......• PLASMACLUSTER OPERATION

E-11

• ADDITIONAL NOTES ON OPERATION .....

E-3

• ONE-HOUR OFF TIMER ....................

E-11

• TIPS ON SAVING ENERGY ........................

E-3

• TIMER OPERATION ...........................

E-12

• PART NAMES ..............................................

E-4

• AUXILIARY MODE .............................

E-14

• USING THE REMOTE CONTROL ..............

E-6

• MAINTENANCE ..................................

E-14

• TIPS ABOUT PLASMACLUSTER OPERATION . E-7

• OPTION KIT ........................................

E-15

• BASIC OPERATION ....................................

E-8

• BEFORE CALLING FOR SERVICE ...

E-16

• ADJUSTING THE AIR FLOW DIRECTION . E-10

 

 

PRECAUTIONS

WARNINGS FOR USE

1

Do not pull or deform the power supply cord. Pulling and misuse of the power supply cord

can result in damage to the unit and cause electrical shock.

2

Be careful not to expose your body directly to the outlet air for a long time. It may affect

your physical conditions.

3

When using the air conditioner for infants, children, elderly, bedridden, or disabled people

make sure the room temperature is suitable for those in the room.

4

Never insert objects into the unit. Inserting objects can result in injury due to the high

speed rotation of internal fans.

5

Ground the air conditioner without fail. Do not connect the grounding wire to gas pipe,

water pipe, lightning rod or telephone grounding wire. Incomplete grounding may cause

 

electric shock.

6

If anything is abnormal with the air conditioner (ex. a burning smell), stop the operation

immediately and turn the circuit breaker OFF.

7

Follow local rules and regulations for power supply cord cabling. Improper cable

connection can cause the power supply cord, plug and the electrical outlet to overheat

 

and cause fire.

8

Use only the manufacture-specified power cord for replacement. Replacement should be

performed by a qualified technician or a service person.

WARNINGS FOR INSTALLATION / REMOVAL / REPAIR

Do not attempt to install/remove/repair the unit by yourself. Incorrect work will cause electric shock, water leak, fire etc. Consult your dealer or other qualified service personnel for the installation/removal/repair of the unit.

This equipment complies with the requirements of Directives 89/336/EEC and 73/23/ EEC as amended by 93/68/EEC.

ENGLISH

E-1

Open a window or door periodically to ventilate the room, especially when using gas appliances. Insufficient ventilation may cause oxygen shortage.

PRECAUTIONS

CAUTIONS FOR USE

1

2

Do not operate the buttons with wet hand. It may cause electric shock.

3

For safety, turn the circuit breaker off when not using the unit for an extended period of

time.

4

Check the outdoor unit mounting rack periodically for wear and to make sure it is firmly

in place.

5

Do not put anything on the outdoor unit nor step on it. The object or the person may fall

down or drop, causing injury.

6

This unit is designed for residential use. Do not use for other applications such as in a

kennel or greenhouse to raise animals or grow plants.

7

Do not place a vessel with water on the unit. If water penetrates into the unit, electrical

insulations may deteriorate and cause electric shock.

8

Do not block the air inlets nor outlets of the unit. It may cause insufficient performance

or troubles.

9

Be sure to stop the operation and turn the circuit breaker off before performing any

maintenance or cleaning. A fan is rotating inside the unit and you may get injured.

10 Do not splash or pour water directly on the unit. Water can cause electrical shock or equipment damage.

11 This appliance is not intended for use by young children or infirm persons without supervision.

Young children should be supervised to ensure that they do not play with the appliance.

CAUTIONS FOR LOCATION / INSTALLATION

Make sure to connect the air conditioner to power supply of the rated voltage and frequency.

Use of a power supply with improper voltage and frequency can result in equipment damage and possible fire.

Do not install the unit in a place where inflammable gas may leak. It may cause fire. Install the unit in a place with minimal dust, fumes and moisture in the air.

Arrange the drain hose to ensure smooth drainage. Insufficient drainage may cause wetting of the room, furniture etc.

Make sure a leak breaker or a circuit breaker is installed, depending on the installation location, to avoid electrical shock.

E-2

ADDITIONAL NOTES ON OPERATION

OPERATING TEMPERATURE RANGE

 

 

INDOOR TEMP.

OUTDOOR TEMP.

 

 

upper limit

32˚C

D.B.

43˚C

D.B.

COOLING

23˚C

W.B.

 

-

 

 

 

 

lower limit

21˚C

D.B.

21˚C

D.B.

 

 

15˚C

W.B.

 

-

 

 

 

 

 

 

upper limit

27˚C

D.B.

24˚C

D.B.

 

HEATING

 

-

18˚C

W.B.

 

 

(AY-AP18CE/AY-

lower limit

20˚C

D.B.

-8.5˚C

D.B.

 

AP24CE only)

 

-

-9.5˚C

W.B.

 

 

 

D.B. = Dry-bulb

W.B. = Wet-bulb

 

 

 

 

The built-in protective device may prevent the unit from operating when used out of this range.

Condensation may form on the air outlet if the unit operates continuously in the COOL or DRY mode when humidity is over 80 percent.

WHEN POWER FAILURE OCCURS

This air conditioner has a memory function to store settings when a power failure occurs.

After power recovery, the unit will automatically re-start in the same settings which were active before the power failure, except for timer settings.

If the timers were set before a power failure, they will need to be re-set after power recovery.

NOTES FOR MODELS AY-AP18CE/AY-AP24CE

PREHEATING FUNCTION

In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on to prevent cold air from blowing out of the unit.

DE-ICING FUNCTION

When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an automatic de-icer provides heat for about 5 to 10 minutes to remove the ice. During de-icing, the inside and outside fans stop operating.

After de-icing is completed, the unit automatically resumes operation in the HEAT mode.

HEATING EFFICIENCY

The unit employs a heat pump that draws heat from the outside air and releases it into the room. The outside air temperature therefore greatly affects the heating efficiency.

If the heating efficiency is reduced due to low outside temperatures, use an additional heater.

It takes time to warm up and heat the entire room because of the forced air circulation system.

TIPS ON SAVING ENERGY

Below are some simple ways to save energy when you use your air conditioner.

SET THE CORRECT TEMPERATURE

Setting the thermostat 1°C higher than the desired temperature in the COOL mode (and 2°C lower in the HEAT mode with models AY-AP18CE/AY-AP24CE) will save approximately 10 percent in power consumption.

Setting the temperature lower than necessary during cooling operation will result in increased power consumption.

BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS

Blocking direct sunlight during cooling operation will reduce power consumption.

Close the windows and doors during cooling opeation (and heating operation with models AY-AP18CE/AY- AP24CE).

SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR CIRCULATION

KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION MAKE MOST OF THE TIMER OFF FUNCTION

DISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN EXTENDED PERIOD OF TIME

• The indoor unit still consumes a small amount of power when it is not operating.

ENGLISH

E-3

PART NAMES

INDOOR UNIT

1

1 Inlet (Air)

 

2

2 Open Panel

 

3

3 AUX. Button

 

4

4 Air Filters

 

5

5 Receiver Window

 

6

6 Louvre Unit

 

 

Open to clean the inside of the air

7

conditioner.

 

 

 

8

7 Power Supply Cord

 

9

(AY-AP18CE/AH-AP18CEonly)

 

8 Indicator Panel

 

0

 

q

9 Vertical Adjustment Louvres

w

0 Horizontal Adjustment Louvres

 

q Outlet (Air)

 

 

w Remote Control

 

e

e AUTO FAN SPEED Lamp (green )

r FAN SPEED Lamp (green

)

r

t

t PLASMACLUSTER Lamp

 

 

(blue, green)

 

y

y TIMER Lamp (orange )

 

u

 

 

 

u OPERATION Lamp (red

)

OUTDOOR UNIT

i

i Inlet(Air)

o

o Refrigerant Tube and

Interconnecting Cord

p

p Drainage Hose

 

a Outlet(Air)

a

 

NOTE: Actual units might vary slightly from those shown above.

E-4

Loading...
+ 14 hidden pages