Sharp AH-A12FEF, AH-A9FEF Operating Manual

5 (1)
AH-A9FEF
AH-A12FEF
AH-A9FEF
AH-A12FEF
INDOOR UNIT
SPLIT TYPE
ROOM AIR CONDITIONER
OPERATION MANUAL
AU-A12FF
AH-A9FEF
AH-A12FEF
OUTDOOR UNIT
SPECIFICATIONS ....................................2
IMPORTANT SAFETY INSTRUCTIONS
...3
ADDITIONAL NOTES ON OPERATION ..5
TIPS ON SAVING ENERGY.....................5
PART NAMES...........................................6
USING THE REMOTE CONTROL ...........9
BASIC OPERATION .................................10
ADJUSTING THE AIR FLOW DIRECTION ..
11
TIMER OPERATION.................................12
TURBO COOLING OPERATION..............14
ONE-HOUR OFF TIMER ..........................14
AUXILIARY MODE ...................................15
MAINTENANCE........................................16
BEFORE CALLING FOR SERVICE .........17
CONTENTS
Thank you for purchasing a SHARP air
conditioner. Please read this manual care-
fully before operating the product.
R22
2

SPECIFICATIONS

Model AH-A9FEF AH-A12FEF
Cooling capacity (kJ/h) 9495 12660
Rated freqency (Hz) 60 60
Rated voltage (V) 230 230
Rated current (A) 3.6 4.8
Rated input (W) 825 1100
External dimensions (mm) Indoor unit 810x270x184 790x280x200
(WxHxD) Outdoor unit 730x540x250
Weight (kg)
Indoor unit 8 10
Outdoor unit 28 31
We reserve the right to change the materials and apecifications without notice.
3

IMPORTANT SAFETY INSTRUCTIONS

WARNINGS FOR USE
1
Do not pull or deform the power supply cord. Pulling and misuse of the power supply cord
can result in damage to the unit and cause electrical shock.
2
Be careful not to expose your body directly to the outlet air for a long time. It may affect
your physical conditions.
3
When using the air conditioner for infants, children, elderly, bedridden, or disabled people
make sure the room temperature is suitable for those in the room.
4
Never insert objects into the unit. Inserting objects can result in injury due to the high
speed rotation of internal fans.
5
Ground the air conditioner without fail. Do not connect the grounding wire to gas pipe,
water pipe, lightning rod or telephone grounding wire. Incomplete grounding may cause
electric shock.
6
If anything is abnormal with the air conditioner (ex. a burning smell), stop the operation
immediately and turn the circuit breaker OFF.
7
The appliance shall be installed in accordance with national wiring regulations. Improper
cable connection can cause the power supply cord, plug and the electrical outlet to
overheat and cause fire.
8
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or a similarly qualified person in order to avoid a hazard. Use only the manufacture-
specified power cord for replacement.
WARNINGS FOR INSTALLATION / REMOVAL / REPAIR
Do not attempt to install/remove/repair the unit by yourself. Incorrect work will cause electric
shock, water leak, fire etc. Consult your dealer or other qualified service personnel for the
installation/removal/repair of the unit.
IMPORTANT SAFETY INSTRUCTIONS
CAUTIONS FOR USE
1
Open a window or door periodically to ventilate the room, especially when using gas
appliances. Insufficient ventilation may cause oxygen shortage.
2
Do not operate the buttons with wet hand. It may cause electric shock.
3
For safety, turn the circuit breaker off when not using the unit for an extended period of
time.
4
Check the outdoor unit mounting rack periodically for wear and to make sure it is firmly
in place.
5
Do not put anything on the outdoor unit nor step on it. The object or the person may fall
down or drop, causing injury.
6
This unit is designed for residential use. Do not use for other applications such as in a
kennel or greenhouse to raise animals or grow plants.
7
Do not place a vessel with water on the unit. If water penetrates into the unit, electrical
insulations may deteriorate and cause electric shock.
8
Do not block the air inlets nor outlets of the unit. It may cause insufficient performance
or troubles.
9
Be sure to stop the operation and turn the circuit breaker off before performing any
maintenance or cleaning. A fan is rotating inside the unit and you may get injured.
10
Do not splash or pour water directly on the unit. Water can cause electrical shock or
equipment damage.
11
This appliance is not intended for use by young children or infirm persons without
supervision.
Young children should be supervised to ensure that they do not play with the appliance.
CAUTIONS FOR LOCATION / INSTALLATION
Make sure to connect the air conditioner to power supply of the rated voltage and
frequency.
Use of a power supply with improper voltage and frequency can result in equipment
damage and possible fire.
Do not install the unit in a place where inflammable gas may leak. It may cause fire.
Install the unit in a place with minimal dust, fumes and moisture in the air.
Arrange the drain hose to ensure smooth drainage. Insufficient drainage may cause wetting
of the room, furniture etc.
Make sure a leak breaker or a circuit breaker is installed, depending on the installation
location, to avoid electrical shock.
4
INDOOR TEMP. OUTDOOR TEMP.
COOLING
upper limit
32˚C D.B. 43˚C D.B.
23˚C W.B. -
lower limit
21˚C D.B. 21˚C D.B.
15˚C W.B. -

ADDITIONAL NOTES ON OPERATION

OPERATING TEMPERATURE RANGE
The built-in protective device may prevent the unit from operating when used out of this
range.
Condensation may form on the air outlet if the unit operates continuously in the COOL or
DRY mode when humidity is over 80 percent.
D.B. = Dry-bulb W.B. = Wet-bulb

TIPS ON SAVING ENERGY

Below are some simple ways to save energy when you use your air conditioner.
WHEN POWER FAILURE OCCURS
The air conditioner will stay off even when power is restored.
After power is restored, press the ON/OFF button once more.
If the timers were set before a power failure, they will need to be re-set after power is
restored.
5
SET THE CORRECT TEMPERATURE
Setting the thermostat 1°C higher than the desired temperature in the COOL mode will
save approximately 10 percent in power consumption.
Setting the temperature lower than necessary during cooling operation will result in
increased power consumption.
BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS
Blocking direct sunlight during cooling operation will reduce power consumption.
Close the windows and doors during cooling operation.
SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR
CIRCULATION
KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION
MAKE MOST OF THE TIMER OFF FUNCTION
DISCONNECT THE POWER CORD OR TURN OFF THE CIRCUIT BREAKER
WHEN THE UNIT IS NOT USED FOR AN EXTENDED PERIOD OF TIME
The indoor unit still consumes a small amount of power when it is not operating.

PART NAMES

1 Inlet (Air)
2 Open Panel
3 Air Filters
4 AUX. Button
5 Indicator Panel
6 Receiver Window
7 Power Supply Cord
8 Vertical Adjustment Louvres
9 Horizontal Adjustment Louvres
0 Outlet (Air)
q Remote Control
w TURBO COOLING Lamp (green
)
e TIMER Lamp (orange )
r OPERATION Lamp (red )
OUTDOOR UNIT
NOTE: Actual units might vary slightly from those shown above.
INDOOR UNIT (AH-A9FEF)
1
2
3
4
5
6
7
8
9
0
q
t Inlet(Air)
y Refrigerant Tube and
Interconnecting Cord
u Drainage Hose
i Outlet(Air)
6
w
e
r
t
y
u
i
Loading...
+ 14 hidden pages