/ BELL TIMER
OPERATING INSTRUCTIONS
ご使用前にこの取扱説明書をよくお読みのうえ、正しくお使いください。 なお、お読みになった後はいつでもご覧いただけますよう、大切に保管してください。
Many thanks for purchasing SEIKO Bell Timer.
Before putting your SEIKO Bell Timer system to use, please be sure to carefully read through this manual as it has been designed to provide you with information for correct handling, use and maintenance necessary for safe, long-lasting and trouble-free operation. Keep this manual at hand for ready reference.
/ CAUTIONS
(4) つきましては、責任を負いかねますのでご了承ください。
(1)This manual is the property of SEIKO and may not without the express written consent of SEIKO be copied or reproduced in any form, in whole or in part, or used for any purpose other than that for which it is supplied.
(2)This manual may be subject to change without notice.
(3)This manual has been prepared to give complete information necessary for the operation, use, handling and maintenance of MODEL QBT-30. For the purpose of our constant technical manual improvement program, your questions, advice, suggestions and comments on the descriptions, illustrations, procedures or any matter concerning this manual are highly appreciated.
(4)SEIKO shall have no liability to the user in respect of any loss or damages, whether consequential or incidental, sustained by the user if such loss or damages are:
1)due to abuse, misuse, failure to observe instructions given in the manual furnished by SEIKO and neglect of other reasonable care and servicing due to be done by the user irrespective of such instructions, and failure due to deliberate actions or gross negligence or accident;
2)caused by changes, modifications, or alterations made without prior written consent of SEIKO or by any person other than authorized by SEIKO; or,
3)due to negligence on the part of the user of what should be done or should not be done as a
good caretaker of Bell Timer Model QBT-30.
/SYMBOLS AND THEIR MEANINGS
The symbols and terms used in this manual are explained below.
DANGER
DANGER is used to indicate the presence of an imminent hazard which is LIKELY to cause SEVERE personal injury, death, or substantial property damage if the instructions under this heading are ignored.
WARNING
WARNING is used to indicate such operational procedures, practices, or situations that may result in personal injury or loss of life if relevant instructions are not followed correctly.
I-5974-3
The following pictorial symbols indicate what must not be done.
|
|
|
|
General |
Prohibition |
Prohibition |
Prohibition |
Prohibition |
against |
against |
against touch |
|
disassembly/t |
exposure to |
|
|
ampering |
water |
|
The following pictorial symbols indicate what must be done.
|
|
|
General |
Connection of |
Extraction of |
instructions |
grounding |
the power |
|
conductor |
plug |
I-5974-3
|
|
/Table of Contents |
|
|
|
||
/ Safety Precautions |
|
||
/ Overview |
|
|
|
/ Features of QBT-30 |
|
||
/ Accessories and Spares |
|
||
/ System Configuration |
|
||
/ Nomenclature and Functions |
|
||
/ Installation |
|
||
7.1 |
/ Precautions |
|
|
/ Installation and Wiring |
|
||
8.1 |
/ Mounting position |
|
|
8.2 |
/ Mounting hole sizes |
|
|
8.3 |
/ Mounting on the wall |
|
|
8.4 |
/ Wiring |
|
|
/ Operation |
|
|
|
9.1 |
/ An outline of the control panel |
|
|
9.2 |
/ Powering-up |
|
|
9.2.1 / Powering-up |
|
||
9.2.2 / SYSTEM RESET |
|
||
9.2.3 / Motion of analog clock hands |
|
||
9.3 |
/ How to set the present time |
|
|
9.4 |
/ How to set the program |
|
|
9.4.1 / Weekly program |
|
||
9.4.2 / Playing of melodies |
|
||
9.4.3 / Dry contact output signal control |
|
||
9.4.4 / Control of melody playing and dry |
|||
|
|
contact output signal |
|
9.4.5 / How to copy a program |
|
||
9.4.6 / How to clear a program |
|
||
9.4.7 / How to clear all the selected programs |
|
||
9.5 |
/ Changeover of dry contact signal output mode |
|
|
9.6 |
/ Melody test |
|
|
9.7 |
/ How to set the summer time |
|
|
9.8 |
(Japan Only) |
|
|
9.8.1 |
|
||
9.8.2 |
|
|
|
9.8.3 |
|
|
|
9.8.4 |
|
|
|
|
|
|
|
(Japan Only) |
|
|
|
10.1 |
|
|
|
10.2 |
|
||
10.3 |
|
||
10.4 |
|
|
|
|
|
||
/ Backup against Commercial Power Failure |
|
||
/ Troubles You Can Solve Yourself |
|
||
/ Daily Servicing by the User |
|
||
/ Warranty |
|
|
|
/ Specifications |
|
|
|
/ Programming Table |
|
I-5974-3
/ Safety Precautions
The following precautions must be strictly observed for the safety of yourself and your fellow workers and for the protection of property from loss and damages.
● / Safety instructions to the customer
/ DANGER
|
|
|
|
||
|
||
Prohibition |
||
|
||
against |
||
Never attempt any of installation work, electrical engineering, and any of |
||
unauthorized |
||
the jobs instructed to the engineering outfit ("Installation Instructions"). All |
||
installation and |
||
of these jobs must always be commissioned to your engineering outfit |
||
electrical |
||
because they involve electric shock hazards, fire hazards and falling |
||
engineering |
||
hazards. |
||
work |
||
|
|
/ WARNING |
|
|
|
|
||
|
|
|
|
|
The Bell Timer QBT-30 is designed for indoor use, |
and must not be |
|
installed outdoors. Otherwise, rainwater may infiltrate into the product to |
|||
|
|||
cause electric shock or fire accident. |
|
||
Selection of |
|
||
location |
|||
|
|
||
|
|
||
|
It must not be installed in the bathroom or washing area or other damp |
||
|
places, either. This may cause fire or electric shock hazard. |
||
|
|
||
|
|
||
|
|
||
|
|
||
Actions to take |
|
||
in case of |
In case of abnormalities (QBT-30 is giving forth smoke, burnt smell, or is |
||
troubles |
hot to the touch, or showing other abnormal symptoms), shut down QBT-30 |
||
|
immediately, unplug the power cord, and call your nearby SEIKO dealer or |
||
|
agent for repair service. If QBT-30 is left to take care of itself, it may result in |
||
|
a risk of electric shock or fire. |
|
|
|
|
||
|
|||
|
|
||
Prohibition |
|
||
against |
|
|
|
unauthorized |
Call your nearby SEIKO dealer or agent for repair service. Unauthorized |
||
disassembly, |
disassembly, repair or modification may cause electric shock accidents or |
||
repair or |
fire accidents. |
|
|
modification |
|
|
|
|
|
||
|
|
||
|
|
||
To operate QBT-30, its door needs to be opened |
to expose internal |
||
Operating |
|||
components. Do not meddle with any parts other than designated controls. |
|||
precautions |
|||
Otherwise, fatal electric shock or fire accident may result. |
|||
|
|||
|
1 |
I-5974-3 |
|
|
|
|
|
|||
|
|
|||
|
||||
Prohibition |
||||
|
||||
against wetting |
||||
with liquids |
Never immerse QBT-30 into water or any other liquid, or never splash water |
|||
(water, |
or any other liquid against QBT-30. Should any liquid enter QBT-30, unplug |
|||
chemicals) |
the power cord, and call your SEIKO dealer or agent for inspection and |
|||
|
servicing. If QBT-30 is left to take care of itself, it may result in a risk of |
|||
|
electric shock or fire. |
|||
|
|
|||
Prohibition |
||||
|
||||
against |
||||
Never operate QBT-30 or POWER switch with wet hands. Otherwise, you |
||||
handling with |
||||
may be killed by electric shock. |
||||
wet hands |
||||
|
|
|
||
|
|
|||
|
|
|||
|
Always hold the plug firm when plugging and unplugging the power cord. If |
|||
|
you strain the power cord, it may be damaged to cause fire or electric shock |
|||
|
hazard. |
|||
|
|
|||
|
|
|||
Handling of |
Handle the power cord with care not to damage it. Never load the power |
|||
power cord |
cord with a heavy object. Never bend over the power cord unduly. All these |
|||
|
could lead to fatal electric shock or fire accident. |
|||
|
|
|||
|
|
|||
|
Never use the damaged power cord or shoddily-repaired power cord as by |
|||
|
taping. This may cause fire or electric shock hazard. |
|
|
|
/WARNING |
|
|
|
|
|
|
|
Use a power supply of a specified rating only. Otherwise, electric shock or |
|
fire accident may result. |
|
|
Power supply |
|
|
Before plugging the power cord into the wall outlet, make sure that the |
|
power supplied to the primary terminals of the circuit breaker has a |
|
specified voltage rating. If the rating is other than specified for QBT-30, |
|
electric shock or fire accident may result. |
|
|
|
|
|
|
|
|
|
|
Confirmation of |
Check to see if a grounding conductor is terminated to QBT-30. If QBT is |
grounding |
not grounded, electric shock accident may result when the product gets |
|
faulty or leaky. The grounding work is required to be of Class D or higher |
|
rating, and shall be undertaken by a licensed electrician. |
|
|
|
|
|
|
Prohibition |
|
against |
Call your SEIKO dealer or agent for fuse replacement service. Do not |
unauthorized |
attempt the fuse replacement yourself unless you are qualified for the job. |
fuse |
This is important to prevent fatal electric shock accident. |
replacement |
|
2 |
I-5974-3 |
|
|
|
|
|
|
|
Precautions on |
Before cleaning the surface of the casing, be sure to unplug the power |
|
the servicing of |
cord. Fatal electric shock accident may happen if you attempt to wipe the |
|
QBT-30 casing |
casing with a damp cloth. |
|
|
|
|
|
||
|
||
Prohibition |
||
against |
|
|
unauthorized |
Call your SEIKO dealer or agent for the servicing of internal components. |
|
servicing of the |
Do not attempt yourself unless you are qualified for the job. This is |
|
internal |
important to prevent fatal electric shock accident. |
|
components |
|
● / Instructions to the engineering outfit
/ For the engineering outfit
/WARNING
/ Precautions on installation work
|
|
|
|
|
|
|
The Bell Timer QBT-30 is designed for indoor use, and must not be |
|
|
installed outdoors. Otherwise, rainwater may infiltrate into the product to |
|
Selection of |
cause electric shock or fire accident. |
|
location for |
|
|
installation |
|
|
|
It must not be installed in the bathroom or washing area or other electric |
|
|
shockor fire accident-prone damp places, either. |
|
|
|
|
|
|
|
|
||
|
||
Make sure that the wall or other structure onto which the product is to be |
||
Load-bearing |
mounted has a sufficient strength to bear up against the load of the |
|
capacity |
product. The maximum weight of the product is about 2 kg. If the wall |
|
|
strength is not sufficient, it may yield to the product weight or external |
|
|
shocks, letting fall the product to cause fatal accidents. |
|
|
|
|
|
||
|
||
|
||
|
||
Fasten the product onto the wall using anchor plugs (PY plug or the like) |
||
Mounting onto |
||
and wood screws. Never use the wood screws alone to fasten the |
||
the concrete |
||
product. Wood screws may yield under wind pressure and vibrations, and |
||
wall |
||
let fall the product to cause fatal accidents. |
||
|
||
|
|
|
|
|
|
Be sure to tighten each wood screw into the anchor plug fully. If the |
||
|
||
screws are not fastened securely, the product may come off from the wall |
||
Fastening |
||
as the screws may loosen off under the influence of wind pressure or |
||
|
||
|
vibrations, causing fatal accidents. |
3 |
I-5974-3 |
|
● / Instructions to the engineering outfit
/ For the engineering outfit
|
|
|||
|
|
|||
Prior to the wiring of the terminal blocks for power input and contact signal |
||||
Electrical |
||||
output circuits, make sure that the power cord is unplugged. You are |
||||
engineering |
||||
warned against working on live circuits as they involve fatal electric shock |
||||
|
||||
|
hazards. |
|||
|
|
|||
|
|
|||
|
|
|||
Ground the Bell Timer Model QBT-30 by connecting a grounding |
||||
Grounding work |
||||
conductor to its grounding terminal. This is important for the prevention of |
||||
|
||||
|
electric shock hazards in case of troubles such as earth leakage fault. |
|||
|
The grounding work must be Class D or higher in rating. |
|||
|
|
|||
|
||||
|
||||
|
||||
After wiring the terminal blocks for power supply and contact signal output |
||||
Installation of |
||||
circuits, be sure to replace the terminal board cover for the protection of |
||||
terminal board |
||||
operators against electric shock. |
||||
cover |
||||
|
|
|
||
|
|
|
|
|
|
|
|||
|
|
|||
|
Use a power supply of a specified rating only. Otherwise, electric |
|||
|
shock or fire accident may result. |
|||
|
|
|
|
|
|
|
|
||
Power supply |
|
|||
|
||||
|
|
|||
|
Before plugging the power cord into the wall outlet, make sure that the |
|||
|
power supplied to the primary terminals of the circuit breaker has a |
|||
|
specified voltage rating. |
|||
|
|
|
|
/ Overview
ィの自動演奏や外部への接点出力を行うことが出来ます。これらのプログラムは、各曜日単位に設定 可能な週間プログラム方式となっており、操作が容易になっています。
SEIKO bell timer Model QBT-30 serves as an analog clock. In addition, QBT-30 is capable of being programmed to play melodies automatically at preset times and/or deliver contact signal output to external circuits. A weekly programming system is used to specify the sequence of these operations on a day-of-the-week basis.
If SEIKO TimeLink(R) transmitter-receiver or LF radio receiver available as optional feature is used, it is possible to receive the standard radio wave automatically at regular intervals to keep accurate time for QBT-30 at all times. (Japan Only)
4 |
I-5974-3 |
|
/ Features of QBT-30
■±
・ニカド電池の不採用 ・消費電力の低減
■Equipped with a high-precision quartz oscillator, the internal clock operates at a monthly average rate of ± 3 seconds.
■An automatic hand-correction movement is employed, eliminating the need for analog clock hand setting at the time of time setting.
■Up to 60 programs can be set to cover a wide range of applications.
■Two independent channels are available for dry contact signal outputs for control of various devices.
■10 melodies are available for programming.
■(Japan Only) Optional TimeLink(R) function eliminates the need for time setting. QBT-30 automatically responds to the implementation of summer time system. (For the implementation of the daylight-saving system, these options are required: ZA303N or SLR-201, and SW-302)
■Featured by the following, QBT-30 is an environmentally friendly product.
Conforming to RoHS DirectiveElimination of need for Ni-Cd batteriesReduction of power consumption
/ Accessories and Spares
|
|
|
|
Accessories and Spares |
Quantity |
Remarks |
|
|
|
|
|
|
/6 pcs. |
|
|
Crimp terminal (M3) |
For power input and contact signal output |
||
|
|||
|
|
|
|
|
/1 pc. |
|
|
Crimp terminal (M4) |
For grounding |
||
|
|||
|
|
|
|
|
/3 pcs. |
|
|
Round-headed wood screw(M4.1) |
For securing QBT-30 |
||
|
|||
|
|
|
|
|
/1 sheet |
|
|
Mounting hole drilling template |
For drilling QBT-30 mounting holes |
||
|
|||
|
|
|
|
|
/1 pc. |
|
|
AC power cord |
For AC100V (Japan only) |
||
|
|||
|
|
|
|
|
/1 copy |
|
|
Operating instruction manual |
This manual |
||
|
|||
|
|
|
|
|
/1 card |
|
|
Warranty registration card |
(Japan only) |
||
|
|||
|
|
|
5 |
I-5974-3 |
|
/ System Configuration
/ Illustrated Examples of Uses
Power input
AC90V 120V
AC200V 240V
Lights, etc.
QBT-30
LINE OUT
Built-in speaker
Japan Only
/ Contact signal output
|
|
||
|
|
||
|
|
* Available for control of |
|
|
|
power supply to the |
|
|
luminaires, external |
||
|
amplifiers, etc.
External |
|
|
External speaker |
||
amplifier |
||
|
6 |
I-5974-3 |
|
/ Nomenclature and Functions
/
Terminal blocks for power input and contact signal output
|
/ GND terminal |
/ Analog clock
/ Speaker |
/ |
/ LCD screen |
/ Speaker |
|
Control panel |
||||
|
||||
● |
|
|
|
|
|
|
|
|
|
● |
|
|
||
|
|
|
●Analog clock
●Control panel
●LCD screen
●Speaker
●LINE OUT
●Terminal blocks for power input and contact signal output
●GND terminal
アースに接続します。
Two-hand type
Interlocked with the built-in digital clock Used for time setting and timer programming.
The control panel can be manipulated while visually checking the settings on the LCD screen.
Usually, indicates the present time digitally.
During setting up, displays the data being set up for you confirmation.
Plays a melody.
Melody output terminal, to be connected to an external amplifier.
For AC power supply, and contact signal output (2 channels)
To be connected to the grounding conductor.
7 |
I-5974-3 |
|
/Installation
/ WARNING
Prohibition against unauthorized installation and electrical engineering work
Never attempt any of installation work, electrical engineering, and any of the jobs instructed to the engineering outfit ("Installation Instructions") because electric shock, fire and toppling hazards are involved.
● / Instructions to the engineering outfit
/ For the engineering outfit
/ Precautions
/ Selection of location for installation
WARNING
The Bell Timer QBT-30 is designed for indoor use, and must not be installed outdoors. Otherwise, rainwater may infiltrate into the product to cause electric shock or fire accident.
WARNING
It must not be installed in the bathroom or washing area or other electric shockor fire accident-prone damp places.
Select an installation place least susceptible to the influence of temperature, humidity and vibration. The ambient temperature of the selected place should be held within the range of -10 to +50 .
/ Load-bearing capacity
WARNING
り付けた場合、振動などで製品が落下し、人身事故にいたることがあり ます。
Make sure that the wall or other structure onto which QBT-30 is to be mounted has a sufficient strength to bear up against the weight of QBT-30. The maximum weight of QBT-30 is about 2 kg. If the structural strength is not sufficient, it may yield to the weight of QBT-30 or external shocks, letting fall QBT-30 to cause fatal accidents.
8 |
I-5974-3 |
|
● / Instructions to the engineering outfit
/ For the engineering outfit
/ Power supply
WARNING
Use a power supply of a specified rating only. Otherwise, electric shock or fire accident may result.
90 120 200 240 50Hz 60Hz
Use an exclusive power supply as the clock system runs 24 hours a day, 365 days a year. The power supply should provide AC90V - AC120V or AC200V - AC240V, and its frequency should be 50Hz or 60Hz.
/ Electrical engineering work
WARNING
Before plugging the power cord into the wall outlet, make sure that the power supplied to the primary terminals of the circuit breaker has a specified voltage rating. If the rating is other than specified for QBT-30, electric shock or fire accident may result.
9 |
I-5974-3 |
|
● / Instructions to the engineering outfit
/ For the engineering outfit
/ Installation and Wiring
/ Mounting position
壁、天井から離してください。
Provide a clearance of at least 10cm at the top and left of QBT-30 to facilitate the open-close operation of the front door.
/ Ceiling
( /Headroom) 10 cm
Wall
10 cm
( /
Clearance at left)
/ Mounting hole sizes
210mm
302mm
*Mark off and make the mounting holes by making use of the mounting hole drilling template furnished. Or you may fix the mounting wood screws temporarily by making use of the mounting hole drilling template.
10 |
I-5974-3 |
|
● / Instructions to the engineering outfit
/ For the engineering outfit
/ Mounting on the wall
● / Mounting on a concrete wall
*Prepare PY plugs for M4.1 wood screws. These anchor plugs are available on the market.
木ネジだけの取り付けは、絶対に行わないでください。
If the wall is made of concrete, use PY plugs and wood screws for
WARNING mounting QBT-30. Never use the wood screws alone for mounting as they may come off under the influence of wind pressure or vibrations to
cause fatal accidents.
/ |
|
PY plug |
Drill mounting |
|
holes. |
: PY |
Drill hole: Specified PY plug |
/ Wood |
screw |
|
|
|
|||
|
|
|
|||
Drive PY plugs |
Cut off the |
Mount QBT-30, |
|||
into the drilled |
excess |
and secure with |
|||
mounting holes. |
projections. |
the wood screws |
|||
|
|
|
|
furnished. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Cable entry |
Mounting hole |
|||||
|
|
|
|
|
|
|
|
|
|
|
( ) |
||
|
|
|
|
Mounting screw (wood screw) |
||
|
|
|
|
|
|
|
|
|
|
|
( ) |
||
|
|
|
|
PY plug (in case QBT-30 is to be |
||
|
|
|
|
installed on a concrete wall) |
11 |