1.Using the User Codes:

A. User codes operate the door (4-8 digits long).

Press

B. The # key must be pressed also if the keypad is in manual-entry mode.

Press u u u u

#

 

 

2. Using the Master Code:

Note: u u u u indicates the user code.

Note: X X X X indicates the master code.

The Master Code can be used to operate the door or program the keypad (4-8 digits long, see pt. 5 below).

Press

X

X

X

X

#

1

(Relay output #1)

Press

X

X

X

X

#

2

(Relay output #2)

 

 

 

 

 

 

 

 

3.Using the Inhibit/Lockout Code:

Please contact your installer for an explanation of inhibit mode and its operation.

4.Using Duress Codes:

For a full explanation of duress codes and their uses, see pg. 12.

5.Delete/Add/Change User and Master Code:

WARNING -- Press the correct option key. If the option key is not used and a "0" is pressed after entering the Master Code, it could accidentally reprogram the Master Code.

A. Enter the Master Code first, followed by the * key

(If you forgot the master code, see page 15 for more information.

 

 

Press

X X X X

*

 

 

 

 

 

 

 

 

B. Changing/Adding Users:

 

 

 

 

 

 

 

 

Press

1

00-99 (user ID)

u

u

u

u

(user code, 4-8 digits)

#

(for relay output #1)

Press

2

0-9 (user ID)

 

u

u

u

u

(user code, 4-8 digits)

#

(for relay output #2)

C. Deleting Individual Users:

 

 

 

 

 

 

 

 

Press

1

00-99 (user ID)

# (for relay output #1)

 

 

Press

2

0-9 (user ID)

 

# (for relay output #2)

 

 

D. Changing the Master Code:

 

 

 

 

 

 

 

Press

0

X X X X

#

 

 

 

 

 

 

 

E. To exit programming mode, press the *

key.

 

 

WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship.

The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.

NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.

Copyright © 2009 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.

SECO-LARM® U.S.A., Inc.

 

 

 

 

16842 Millikan Avenue, Irvine, CA

92606

Website: www.seco-larm.com

® PIHAK1

Tel: 800-662-0800 / 949-261-2999

Fax: 949-261-7326

E-mail: sales@seco-larm.com

MiSK-1123-SQ_0905.pmd

 

 

 

 

 

®

ENFORCERACCESS

MANUAL

SK-1123-SQ

Outdoor Digital Access

Keypad with 2 Outputs

SECO-LARM®

Page 16

SECO-LARM U.S.A., Inc.

 

SECO-LARM USA SK-1123-SQ User Manual
X X X X 8 9 0 1
8 9 0 1

TABLE OF CONTENTS

 

Introduction ................................................................................................................

2

Dimensions ................................................................................................................

2

Unique features .........................................................................................................

3

Wiring - Basic diagram ..............................................................................................

4

Specifications ............................................................................................................

5

Wiring -- Example, with inhibit control authorized ...................................................

6

Wiring -- Example, with connection to lock device and alarm arm/disarm .............

7

List of user codes worksheet ....................................................................................

8,9

Wiring -- Mantrap using two keypads ......................................................................

10

Wiring -- Auxiliary accessories ................................................................................

11

Programming notes ...................................................................................................

12

LED and buzzer indicators ........................................................................................

12

Preparing to Program, Getting Started, and User programming ..............................

13

Installer programming ...............................................................................................

14

Reprogram the keypad (certain data) .......................................................................

15

Reprogram the keypad (complete data refresh) .......................................................

15

Delete user ................................................................................................................

15

Master code bypass (DAP jumper) ...........................................................................

15

User operation ...........................................................................................................

16

INTRODUCTION

The SK-1123-SQ is the ideal keypad for office, commercial, and home security installations. This self-contained security keypad has a built-in 5-Amp relay output and a 1-Amp relay output for maximum flexibility when connecting to electronic door strikes, door alarms, door chimes, alarm control panels, or other security and access control applications. The outputs can be programmed for timed (1-999 seconds) or ON/OFF operation.

The SK-1123-SQ can be programmed for up to 100 4-digit to 8-digit user codes for the primary output, and up to 10 4-digit to 8-digit user codes for the second output. All programming and code information is stored in nonvolatile EEPROM memory to protect the data in case of power loss.

DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2"

 

 

 

 

 

 

(78mm)

 

 

 

 

 

 

 

 

 

 

(51mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

415/16"

 

 

31/4"

45/8"

(125mm)

8

9

(82.5mm)

(118mm)

7

 

 

PARTS LIST

Keypad x 1

Back box x 1

Diode x 1

Installation screws x 3 Mounting screws x 2 Security wrench x 1

113/16"

(45mm)

REPROGRAM THE KEYPAD (CERTAIN DATA)

To change certain data in the keypad (such as to delete or change user codes), do the following:

1. Enter program mode by keying in the master code and the * key:

X X X X * The keypad is now in the programming mode.

2.Use the programming instructions on page 13 and 14 to make any changes to the keypad's data.

3. Exit the programming mode by pressing the * key.

REPROGRAM THE KEYPAD (COMPLETE DATA REFRESH)

Sometimes it may be necessary to completely erase all current data (except the master code) and input new data. An example of when this may be necessary is the sale of a protected building to a new owner. In such a situation, do the following:

1. Enter the programming mode by keying in the master code and the * key, then enter the refresh code, and the # key:

* The keypad is now in the programming mode.

# All old data is cleared and the keypad is ready for new data.

NOTE: The master code does NOT change.

2.Use the programming instructions on pages 13 and 14 to enter the keypad's data.

3. Exit the programming mode by pressing the * key.

DELETE USER

To delete a user who has left the company or who no longer has authority to enter the protected area:

1.

Enter program mode by keying in the master code and the * key:

 

X X X X * The keypad is now in the programming mode.

2.

Enter the output #, user ID number, and the

#

key:

 

 

To delete user ID 05 from output #1, press

1

0 5

# .

 

To delete user ID 1 from output #2, press

2

1

# .

3.Exit the programming mode by pressing the * key.

MASTER CODE BYPASS (DAP jumper)

If the master code is forgotten or does not work, use the DAP (direct access to program) jumper to override the forgotten code and permit direct entry into the programming mode as follows:

1. Disconnect the power supply.

 

 

 

 

 

 

 

 

2. Move the DAP jumper from OFF to ON.

 

 

 

 

 

 

 

3. Reconnect the power supply.

 

 

SECO-LARM®

 

 

 

 

 

SK-1123-SQ

 

 

Tamper

The keypad will start beeping.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Move the DAP jumper back to the OFF position.

 

 

 

 

OFF

 

The keypad will stop beeping as soon as the

 

 

 

 

 

 

 

 

 

 

 

 

DAP

jumper is removed.

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

5. The keypad is now in the programming mode,

 

 

 

 

Tamper

N.C.

ready to receive new programming data.

 

 

 

 

 

 

 

 

 

 

Interlock

6. Re-program the keypad as shown starting

 

 

 

 

 

 

 

 

 

 

O/P 1

Inhibit

on page 13.

 

 

 

 

 

 

 

 

 

 

 

 

Door

Sensor

NOTE -- A new master code may be programmed to

 

 

 

 

 

 

 

 

 

Ground

replace the one that was lost or forgotten. Note that the

 

 

 

 

(--)

 

Relay

 

Relay

Duress

Output

sequence for replacing the old master code is as follows:

 

 

 

1

 

2

 

 

Keypad

Active

 

 

 

 

 

 

 

 

Option*

Key in new code

Confirm

Exit

 

 

 

 

 

Attachment

 

 

#

 

 

 

 

 

 

0

X X X X

*

 

 

 

 

 

Screw

 

 

 

(+)

(--)

Output #1

Output #2

Egress

*Zero "0" is for new master code only; see page 13 for other options.

12-24V

AC/DC N.C.

COM

N.O. N.C. COM

N.O. In

 

 

 

 

 

 

 

Page 2

Page 15

Digital Access Keypad Manual

INSTALLER PROGRAMMING

These functions should only be used by professional installers, as incorrect entries can disable the entire keypad function.

Enter Programming Mode

 

(DEFAULT: 0 0 0 0 )

Enter Master code

Confirm

Function

X X X X *

 

*

 

Enter into programming mode

*Key in the Master Code.

 

 

Note: For first-time use, Master code is

0 0 0 0

 

 

 

 

Data Refresh

 

 

 

Option

 

Confirm

Function

 

 

8

9 0

1

#

Clears all previously stored data.

 

 

 

Configure Relay Outputs

 

(DEFAULT: Momentary, 1-sec. output for both outputs)

Option

Output time

Confirm

Function

4

0

1 to 999

 

#

Relay #1, momentary mode, from 1 to 999 seconds

4

1

 

 

 

#

Relay #1, shunt mode (ON/OFF)

5

0

1 to 999

 

#

Relay #2, momentary mode, from 1 to 999 seconds

5

1

 

 

 

#

Relay #2, shunt mode (ON/OFF)

 

 

 

 

Wrong Code Lockout

 

 

(DEFAULT: 10 tries / 30 seconds)

Option

# of tries

Confirm

Function

7

0

 

 

#

After 10 successive wrong codes, 30-second lockout

7

1

 

 

#

After 10 successive wrong codes, Duress activated

7

2

5 to 10

#

After 5 to 10 wrong codes, 15-min. lockout - Can reset with Master Code

7

6 0

0

 

#

None of the above

 

 

 

Door Forced-Open Alarm

 

(DEFAULT: Disabled)

Option

Code entry

Confirm

Function

8

0

{

1

#

Door forced-open alarm is enabled

0

#

Door forced-open alarm is disabled

 

 

 

 

 

Output Activation Announcer

 

(DEFAULT: On)

Option

Code entry

Confirm

Function

 

 

{

1

#

1-sec. beep notifies the user to open the door when the output relay is activated with the

8

1

 

 

user code or egress button. Use with a locking device which gives no sound when it

 

 

activates, such as a magnetic lock.

 

 

 

 

 

 

0

#

The beep is disabled, replaced by 2 short beeps for valid user codes.

 

 

 

 

User Code Entry Mode

 

 

(DEFAULT: Manual)

Option

Code entry

Confirm

Function

 

 

{

1

#

Auto Entry Mode is selected. The # key that follows the user code is NOT required in

8

2

 

 

code entry. The User Codes MUST be set to the same digit length as the Master Code,

 

 

from 4-8 digits.

 

 

 

 

 

 

0

#

Manual Entry Mode is selected. The # key that follows the user code is required in

 

 

 

 

 

code entry. The User Codes can be 4-8 digits, but not necessarily all of the same length.

 

 

 

 

Keypress Beeps

 

 

(DEFAULT: On)

Option

Code entry

Confirm

Function

8

3

{

1

#

Keypad beeps when a key is pressed.

0

 

Silent operation -- keypad does not beep when a key is pressed.

 

 

#

 

 

 

Door Propped Open Alarm Timer

 

(DEFAULT: Off)

Option

Code entry

Confirm

Function

9

 

 

0

#

No door propped open alarm

 

{1 to 999

#

Allowable time from 1 to 999 seconds that the door can be left open before the door

 

 

propped open alarm starts

Exit Programming Mode

Confirm Function

*Exits programming mode, returns keypad to normal operations

Digital Access Keypad Manual

UNIQUE FEATURES

12-24V AC/DC universal power -- No programming or jumpers needed.

Mantrap -- Each keypad can be used as a stand-alone keypad. However, the mantrap feature uses two keypads to protect an area with two doors by ensuring that only one door is open at a time. With the mantrap interlock functions, when a user keys in the code to open one door, a signal is sent to disable the second keypad, thereby preventing access through the second door until the first door is closed.

Relay output #1 inhibit control -- Relay output #1 is typically used for a door strike. If the keypad is set to the "inhibited" mode, relay output #1 will not operate. This increases the security of the protected premises during the time it is not expected to be occupied, such as during evening or weekend hours. An authorized user can enable or disable the inhibit control by using the code for relay output #2 at any time, depending on how installed.

Door forced open warning -- When used with an optional magnetic contact, the keypad beeps continuously if the door to the protected premises is forced open without using a valid user code. The warning can be stopped only by closing the protected door.

Door propped open warning -- When used with an optional magnetic contact, the keypad beeps continuously if the door is propped open after the allowed open time. The allowable open time is programmable. The warning stops when the door is reclosed.

Auto or manual code entry checking:

Auto code entry checking mode -- When all the user codes have the same number of digits, the keypad will activate automatically when the code is entered. There is no need to press the "#" key. This is convenient for the users.

Manual code entry checking mode -- The user codes can vary in number of digits, and the user must press the "#" key when finished entering the code. This increases security.

Keypad active output -- This NPN transistor open collector ground (-) output activates for 10 seconds when any key on the keypad is pressed. This can be used to trigger a video recorder or turn on a light, or to signal a guard that someone is entering the protected premises.

Door auto relock -- The keypad will relock an open door either when the relock time expires or immediately after the door is closed, depending on which occurs first. This prevents unwanted "tailgate" entries, which can happen if an unauthorized person tries to follow an authorized person through the door.

Duress output -- This NPN transistor open collector ground (-) output can be used to trigger a silent alarm if an authorized user is forced under duress to use the keypad. The duress output is activated by adding 2 to the first digit of user code 1. In this case, the protected door opens as it would normally, but a signal is quietly sent to a remote device to call for help without alerting the unauthorized person.

Backlit keypad -- The keypad is backlit to increase nighttime visibility. For convenience, the lighting intensity will increase for 10 seconds after any key is pressed.

Page 14

SECO-LARM U.S.A., Inc.

Page 3

Loading...
+ 5 hidden pages