Conventional IS Manual
Call Point MCP3A-
R000SG-K013-01IS
Instruction Sheet
R10202GB0

Schneider Electric Fire & Security Oy
Sokerilinnantie 11 C
FI-02600 Espoo, Finland
Tel: +358 10 446 511
Website: www.se.com
Document number: R10202GB0
Published: 06.03.2020
© 2020 – Schneider Electric. All Rights Reserved. This information is only to be used as guidance. Subject to changes and errors.

Contents
1 Intrinsically Conventional Manual Call Point MCP3A-R000SG-K013-
01IS ......................................................................................................... 4
1.1 Product Benefits ........................................................................................................................... 5
1.2 Connection Details ....................................................................................................................... 5
1.3 Dimensions .................................................................................................................................. 5

1 Intrinsically Conventional Manual Call Point MCP3A-R000SG-K013-01IS
1 Intrinsically Conventional Manual Call Point
MCP3A-R000SG-K013-01IS
An Intrinsically Safe version of our MCP3A indoor call point is available for installation in
hazardous areas. These call points are manufactured to protect against other hazards.
They are intended for use within Intrinsically Safe (I.S.) systems using suitable I.S.
barriers.
Suitable IS Barriers:
• Pepperl & Fuchs - KFDO-Cs-Ex 1.51P (BAS98ATEX7343), KFDO-Cs-Ex 2.51P
(BAS98ATEX7343)
• MTL - MTL4061 (BAS01ATEX7176), MTL5061 (BAS01ATEX7160)
A certified shunt zener barrier may be used having the following output parameters;
Uz - 28V, Imax - 93.3mA, Wmax - 0.67W
For a list of suitable barriers see reverse. Installation efficiency, flexibility and full
compliance with the latest standards are at the heart of the Indoor Call Point range.
Installation time and ultimately cost, are of paramount importance to any fire or security
installer. The MCP range directly reflects this need by providing a unique ‘plug and play’
concept designed specifically to reduce installation time. All new MCP products utilize a
special terminal block, where all initial installation cabling is terminated. This terminal
block is then simply connected to the back of the MCP. Simple, but effective with no retermination required and no time wasted.
Through new standards and legislation, both break glass and resettable operating
elements can now be used within a manual call point. To provide you with the greatest
‘flex-ability’, the new MCP range can be configured as either a break glass or resettable
unit by simply changing from one element to another. No other additional parts or
alternative products need to be ordered.
All MCP Indoor Call Point products also help preserve the integrity of the overall system
as illegal removal of the product lid will result in the call point operating and the system
going in to alarm. The MCP3A product version is supplied with one normally open and
one normally closed contact. Selecting either the “Normally Open” or “Normally Closed”
contact is easily achieved by simply connecting the terminal block to the required
connection in the back of the MCP3 Product. Single pole changeover switching can be
achieved with the use of two terminal blocks
N/O= Normally Open Contact
N/C= Normally Closed Contact

1 Intrinsically Conventional Manual Call Point MCP3A-R000SG-K013-01IS
1.1 Product Benefits
• Unique “Plug & Play” installation concept
• Total “Flex-Ability” in the choice of operating element
• Anti-Tamper Facility
• Enhanced aesthetics
• Fully approved to the latest standards
• Backward compatibility
• CPR and Ex approved
• LPCB certificated
1.2 Connection Details
1.3 Dimensions