Schneider Electric R10202GB0 Instruction Manual

Conventional IS Manual Call Point MCP3A-
R000SG-K013-01IS
Instruction Sheet R10202GB0
Schneider Electric Fire & Security Oy
Sokerilinnantie 11 C FI-02600 Espoo, Finland Tel: +358 10 446 511 Website: www.se.com Document number: R10202GB0 Published: 06.03.2020
© 2020 – Schneider Electric. All Rights Reserved. This information is only to be used as guidance. Subject to changes and errors.
Contents
Contents
1 Intrinsically Conventional Manual Call Point MCP3A-R000SG-K013-
01IS ......................................................................................................... 4
1.1 Product Benefits ........................................................................................................................... 5
1.2 Connection Details ....................................................................................................................... 5
1.3 Dimensions .................................................................................................................................. 5
1 Intrinsically Conventional Manual Call Point MCP3A-R000SG-K013-01IS
1 Intrinsically Conventional Manual Call Point
MCP3A-R000SG-K013-01IS
An Intrinsically Safe version of our MCP3A indoor call point is available for installation in hazardous areas. These call points are manufactured to protect against other hazards. They are intended for use within Intrinsically Safe (I.S.) systems using suitable I.S. barriers.
Suitable IS Barriers:
Pepperl & Fuchs - KFDO-Cs-Ex 1.51P (BAS98ATEX7343), KFDO-Cs-Ex 2.51P (BAS98ATEX7343)
MTL - MTL4061 (BAS01ATEX7176), MTL5061 (BAS01ATEX7160)
A certified shunt zener barrier may be used having the following output parameters; Uz - 28V, Imax - 93.3mA, Wmax - 0.67W
For a list of suitable barriers see reverse. Installation efficiency, flexibility and full compliance with the latest standards are at the heart of the Indoor Call Point range. Installation time and ultimately cost, are of paramount importance to any fire or security
installer. The MCP range directly reflects this need by providing a unique ‘plug and play’
concept designed specifically to reduce installation time. All new MCP products utilize a special terminal block, where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple, but effective with no re­termination required and no time wasted.
Through new standards and legislation, both break glass and resettable operating elements can now be used within a manual call point. To provide you with the greatest ‘flex-ability’, the new MCP range can be configured as either a break glass or resettable unit by simply changing from one element to another. No other additional parts or alternative products need to be ordered.
All MCP Indoor Call Point products also help preserve the integrity of the overall system as illegal removal of the product lid will result in the call point operating and the system going in to alarm. The MCP3A product version is supplied with one normally open and
one normally closed contact. Selecting either the “Normally Open” or “Normally Closed”
contact is easily achieved by simply connecting the terminal block to the required connection in the back of the MCP3 Product. Single pole changeover switching can be achieved with the use of two terminal blocks
Model
Part code
Electrical configuration
Mounting
Operating Element
Markings
MCP3A­R000SG­K013-01IS
FFS06425151
N\O & N\C contacts 30VDC
Surface
Glass
EN54-11
N/O= Normally Open Contact N/C= Normally Closed Contact
1 Intrinsically Conventional Manual Call Point MCP3A-R000SG-K013-01IS
1.1 Product Benefits
Unique Plug & Play installation concept
Total Flex-Ability in the choice of operating element
Anti-Tamper Facility
Enhanced aesthetics
Fully approved to the latest standards
Backward compatibility
CPR and Ex approved
LPCB certificated
1.2 Connection Details
1.3 Dimensions
Loading...